Tender For Supply, Installation, Testing And Commissioning For Underground Cabling Of Ht/Lt Network At Old Bazar Kargil Under Conservation And Preservation Of Old Bazar As Silk Route Market On Full Turnkey Basis F-Y 2026-27
Tender Overview
Project Description
Tender for Supply, Installation, Testing And Commissioning For Underground Cabling Of Ht/Lt Network At Old Bazar Kargil Under Conservation And Preservation Of Old Bazar As Silk Route Market On Full Turnkey Basis F-Y 2026-27
BOQ
| Sl. No. | Item Description |
| 1 | SUPPLY TESITING AND COMMISSIONING OF CONVERSION OF OVERHEAD 11KV CIRCUIT TO UNDERGROUND LINE FOR WIDENING OF ROAD |
| 2 | 11Mtr. Long ST Pole |
| 3 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 4 | 33kV Polymeric composite Pin Insulator 36KV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm |
| 5 | 33kV Polymeric composite Disc Insulator 36KN, min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm |
| 6 | GI Bed Channel/Angle/Flat of sizes including clamps |
| 7 | Galvinized Nuts and Bolts. |
| 8 | Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip. |
| 9 | GI Barbed Wire for Anti Climbing |
| 10 | Cement bottoming 1:2:4 mix as per REC standards.5cum/pole |
| 11 | Painting of Poles Red Oxide |
| 12 | Painting of Poles Aluminium Paint |
| 13 | 11KV, Single-core 240sqmm Aluminium Conductor round wire Al armoured XLPE cable FRLS in single run Supply of 11000V grade, Al conductor, XLPE insulated and armoured FRLSH cables suitable for operation at outdoor site conditions (min. temp -22ndegree celsius, design temp. +40 degree celsius, storage temp. of -22 degree celsius, altitude of > 3515m above m.s.I.) of Ladakh |
| 14 | Single Core 240Sqmm, Cable Termination Kit (Outdoor), 33KV Insulation HT heat shrinkable |
| 15 | HDPE Pipe of required sizes for safe passage of 240sqmm HT Cable including Joints of required sizes as per site requirement |
| 16 | Cable phase Identification plate |
| 17 | Route Marker |
| 18 | SITC for conversion of existing overhead LT Power distribution network into Under ground Cable at Old bazar Kargil |
| 19 | Cable XLPE insulated, screened, PVC bedded, FRLS Type, gulvanised steel strip or wire armoured, electric power cables(heavy duty) 1100 Volts grade with stranded aluminium conductor 185 Sqmm, 3.5 Core |
| 20 | Cable XLPE insulated, screened, PVC bedded, FRLS Type, gulvanised steel strip or wire armoured, electric power cables(heavy duty) 1100 Volts grade with stranded aluminium conductor 240sqmm, 3.5 Core |
| 21 | LT panel of suitable size as per IE rule and latest IS , factory made dust and vermin proof outdoor type made out of 3.15mm thick CRCA sheet including separate compartement for each MCCB & for cables and busbar, mounted on frame of MS angle iron 40mmx40mmx6mm with front and back operable door with lock and key including necessary grouting and double coat powder coated of grey colour painting complete with following accessories. The degree of protection of panel shall be IP-45 including foundation all as specified and directed (Main Panel)Incominga. TPN MCCB 400Amps., 415Volt With rupturing capacity 36kA = 1 Nos.b. Al. Bas Bar 3-Phase, 4 strips suitable for 630Amps. Current carrying capacity complete with post insulators and heat shrinkable sleevesOutgoingTPN MCCB 200Amps, 415Volts AC with rupturing capacity 36kA = 4 Nos.Meteringa. RYB indication lamps = 3 Nos.b. Voltmeter digital type with range 0-500 Volts = 1 No.c. Ammeter digital type with range 0-630 Amps = 1No.d. CT of CTR 400/1 = 1 Set |
| 22 | LT panel of suitable size as per IE rule and latest IS (seperate compartment for provision of fixing of 8 nos. Smart meter) , factory made dust and vermin proof outdoor type made out of 3.15mm thick CRCA sheet including separate compartement for each MCCB & for cables and busbar, mounted on frame of MS angle iron 40mmx40mmx6mm with front and back operable door with lock and key including necessary grouting and double coat powder coated of grey colour painting complete with following accessories. The degree of protection of panel shall be IP-45 including foundation all as specified and directed (Sub Feeder Panel-1)IncomingAl. Bas Bar 3-Phase, 4 strips suitable for 630Amps. Current carrying capacity complete with post insulators and heat shrinkable sleeves, Thibmle of sizesTPN MCCB 100Amps, 415Volts AC with rupturing capacity 36kA = 1 Nos.Outgoinga. TPN MCCB 63Amps, 415 Volts AC with rupturing capacity 36kA = 2 Nos.b. Single -pole MCB 32Amps, 230 Volts AC with rupturing capacity 36kA = 12 Nos.Meteringa. RYB indication lamps = 3 Nos.b. Voltmeter digital type with range 0-500 Volts = 1 No.c. Ammeter digital type with range 0-630 Amps = 1 No.d. CT of CTR 100/1=1 Set |
| 23 | Chemical earthing complete with all clamps, GI strips of required sizes, nuts and bolts, washers etc to be used to achieve the recommanded earth resistance value for higher resistivity locations. |
| 24 | HDPE pipe of required sizes along with clamps for Cable termination |
| 25 | Termination for 3.5c*240sqmm with DC GLANDS and Thimbles and additional accessories |
| 26 | Termination for 3.5c*185sqmm with DC GLANDS and Thimbles and additional accessories |
| 27 | route marker |
| 28 | Cable tag |
| 29 | Straight Through Jointing Kit for 185sqmm cable |
| 30 | Dismantling of existing HT/LT Overhead Line and 9/8 mtr ST pole and right back of material to Divisional store at Megawatt kurbathang. |
| 31 | Dismantalling of old 9mtrs and 11Mtr. poles with accessories like conductor, AB Cables, Insulartors, Cross Arms and return back to PDD store |
| 32 | Dismantling, shifting and re-fixing of existing smart meter |
| 33 | Dismantling and stacking of existing LT Overhead Line Complete Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents