Housing Urban and Rular Development Government Departments Closing in 14 days TDR #58617890

Tender For Construction Of Office Building (G+2 Storied) Of Dws Division Kalyanpur With Foundation Provision For (G+3)Storey At Kalyanpur Dws Office Premises Under Kalyanpur Block Area, Khowai District, Tripura./Sh:- Building Portion Including Intern

Issued by Government Departments · Khowai, Tripura
Tender Value
7.43 Crore
Estimated cost
Bid Submission
04 Dec 2026
14 days left
EMD
14.87 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Khowai → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Office Building (G+2 Storied) Of Dws Division Kalyanpur With Foundation Provision For (G+3)Storey At Kalyanpur Dws Office Premises Under Kalyanpur Block Area, Khowai District, Tripura./Sh:- Building Portion Including Internal Water Supply, Sanitary Installation, Sewage , Drainage Works Including Boundary Wall.

BOQ

Name of Work:- Construction of Office building (G+2 storied) of DWS Division Kalyanpur with foundation provision for (G+3)Storey at Kalyanpur DWS office premises under Kalyanpur block area, Khowai district, Tripura./SH:- Building portion including Internal water supply, Sanitary Installation, Sewage , Drainage works including boundary wall.
Sl. No. Item Description
1SUB-HEAD : EARTH WORK
2Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.
3All kinds of soil
4Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
5All kinds of soil
6Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
7All kinds of soil
8Extra for additional lift of 1.5m or part thereof.
9All kinds of soil
10Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
11Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete.
12Supplying chemical emulsion in sealed containers including delivery as specified.
13Chlorpyriphos/Lindane emulsifiable concentrate of 20%
14Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment as per IS: 6313 (Part III)- Latest revision (excluding the cost of chemical emulsion):
15(i) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. - With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.
16(ii) Treatment of soil under plinth filling using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with sand filling: - With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.Note: For ANTI TERMITE TREATMENTThe work will be carried out as per IS: 6313 [Latest Revision].Under the Insecticides Rule 1971: 10(3A) any person who desires to undertake pest control operations will be a Licence holder.The agency must complying with all safety health and welfare regulations, appertaining to staff and work people employed on the site.Keeping the site free from debris arising from the works during the work and leave the site free from debris on completion of work to the satisfaction of the Owner.The agency shall give a 3-year service guarntee in writing supplemented by a seperate and unilateral guarantee from the specialised agency for the job to keep the building free of termites for the specified period at no extra cost of the Owner.
17SUB-HEAD : CEMENT CONCRETE WORK
18Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level:
191:4:8 ( 1 Cement: 4 fine sand : 8 graded stone aggregate 40 mm nominal size)
201:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate 20 mm nominal size)
211:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size)
22Centering shuttering including struttings, propping etc. and removal of form work for:
23Foundations, footings, bases for columns.
24Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification
25Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
26SUB-HEAD : RCC WORK
27Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level:
281:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
29Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement-
301:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
31Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies,shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-
321:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
33Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with
341:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
35Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
36Thermo-Mechanically Treated bars of grade Fe-500D or more
37Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
38Thermo-Mechanically Treated bars of grade Fe-500D or more
39Providing precast cement concrete Jali 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3(1cement : 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits
4050 mm thick
41Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in vertical & horizontal fins, individually or forming box louvers, setting in cement mortar 1:2 (1 cement : 2 coarse sand), including the cost of required centering, shuttering but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size).
42Centering shuttering including struttings, propping etc. and removal of form work for:
43Foundations, footings, bases for columns etc. for mass concrete with timber plank
44Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. using shuttering ply
45Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply
46Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply
47Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply
48Stairs (excluding landings) except spiral-staircases with wooden plank
49Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards.
50Edges of slabs and breaks in floors and walls under 20 cm. wide
51Weather shade, Chajjas, corbels etc., including edges.
52Smooth finishing of the exposed surface of R.C.C. work with 6mm thick cement mortar 1:3 (1 Cement: 3 fine sand)
53Providing and fixing Galvanized chicken mesh (24 guage, 12 mm size) properly stretched and nailed ensuring equal thickness of plaster at junction of masonry work and concrete members.
54Providing and fixing sheet covering over expansion joints with iron screws as per design to match the colour /shade of wall treatment.Non-asbestos fibre cement board 6 mm thick as per IS: 14862 [150mm wide]
55Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size).
56SUB-HEAD : BRICK WORK
57First class brick work in foundation and plinth including cost of all materials as required complete.
58In cement mortar 1:4 ( 1 cement : 4 fine sand ).
59In cement mortar 1:6 ( 1 cement : 6 fine sand ).
60First class brick work in superstructure above plinth level & upto floor-five level including cost of all materials as required complete.
61In cement mortar 1:6 ( 1 cement : 6 fine sand ).
62Half brick masonry with first class bricks in superstructure upto floor five level including cost of all materials as required complete:-
63In cement mortar 1:4 ( 1 cement : 4 fine sand ).
64Extra for providing & placing in position 2 nos 6mm dia MS bars at every 6th course of full brick masonry work including anchorage in joints of 75mm in each side in superstructure for all level including cost of all materials as required complete:-
65In cement mortar 1:6 ( 1 cement : 6 fine sand ).
66Extra for providing & placing in position 2 nos 6mm dia MS bars at every 4th course of half brick masonry work including anchorage in joints of 75mm in each side in superstructure for all level including cost of all materials as required complete:-
67In cement mortar 1:4 ( 1 cement : 4 fine sand ).
68SUB-HEAD : WOOD & PVC WORK
69Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/ Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
70Frame Size 65 X 150 mm
71Frame Size 45 X 85 mm
72Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for paneled or paneled and glazed shutters 25 to 40 mm thick.
73Local Teak Wood 16mm. Thick
74Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veeners on both faces of shutters.
7535 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
76Providing and fixing 18 mm thick, 150 mm wide pelmet of flat pressed 3 layer or graded wood particle board medium density grade I, IS : 3087 marked including top cover of 6 mm commercial ply wood conforming to IS: 303 BWR grade, nickel plated M.S. pipe 20 mm dia (heavy type) curtain rod with nickel plated brackets including fixing with 25 × 3 mm M.S. flat 10 cm long and rawl plugs 50 mm long (designation 10 no.) etc. all complete
77Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.
78Fixed to openings /wooden frames with rawl plugs screws etc.
79Providing 40 × 5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30 × 10 × 15 cm 1:3:6 mix (1 cement : 3 fine sand : 6 graded stone aggregate 20mm nominal size)
80Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
81300 x 16 mm
82250 x 16 mm
83Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :
84300 x 10 mm
85250 x 10 mm
86Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
87125 mm
88100 mm
89Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.
90Single rubber stopper
91Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality) as per direction of Engineer-in-charge.
92Providing and fixing factory made door frame (single rebate) made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 60mm width & 30mm thickness and shall be fixed to wall as per instructions of Engineer-In-Charge using 100x8 sheet metal CSK screws.
93Providing and fixing 28 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71mm width & 28mm thick as vertical & horizontal styles. Joints are made using solvent adhesive and GI ‘C sections (39mm x 19mm x 0.6mm thick) or M S pipe (40mm x 20mm ) stiffener frame insert & telescopic polymeric ‘L’ corners .The panel shall be filled with 3mm thick high - pressure compact laminate as per manufacturer’s specifications and directions of the Engineer-in-charge, cover moulding shall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter).
94Providing 50 × 50 × 50 mm Gamair wood plugs including cutting brick work and fixing in cement mortar 1:3 (1 cement: 3 fine sand) and making good the walls etc. i) 25 mm long
95SUB-HEAD : STEEL WORK
96Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm at 100 mm centre to centre and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia. steel pulleys & with riveted bolts, nuts, locking arrangement, stoppers, handles, hold fast /anchor bolt including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required.
97Providing and fixing fan clamp type-I of 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs during laying including painting the exposed portion of loop, all as per standard design complete.
98Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
99Hot finished welded type tubes
100Providing and fixing M.S. round holding down bolts with nuts and wahser plates complete as per standard design.
101Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
102Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 275mm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters & with handles, hold fast including embedding in cement concrete of required grade required for fixing in position, all necessary fittings, including applying of approved steel primer etc. complete as required:-
10380x 1.25mm M.S. laths with 1.25 mm thick top cover.
104Providing and fixing in position 1mm thick M.S. sheet sliding-shutters with frame and diagonal braces of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junction and corners 25mm dia pulley, 40x40x6mm angle and T-iron guide sufficiently long at the top and bottom respectively, channels & with bolts, nuts, rivets, locking arrangement, stoppers, handles, hold fast including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required.
105Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. complete as required:-
106In grating, frames, guard bar, railing, brackets, gates and similar works, all complete.
107Providing structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as required.
108SUB-HEAD : ALUMINIUM WORK & STRUCTURAL GLAZING
109Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof.
110The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.
111Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawing and the direction of Engineer­in­charge. (Glazing and paneling and dash fasteners to be paid for separately) :-
112For fixed portion of approved quality:-Powder coated aluminium ( minimum thickness of powder coating of 50 micron )
113For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing fittings wherever required including the cost of EPDM rubber / neoprene gasket required ( Fittings shall be paid for separately ):-
114Powder coated aluminium ( minimum thickness of powder coating of 50 micron ).
115Providing and fixing glazing of approved quality in aluminium doors, windows, ventilator, shutters and partition etc. with EPDM rubber / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paid in basic item) :-
116With float glass panes of 4.0 mm thickness ( weight not less than 10.00 kg / sqm )
117Providing and fixing stainless steel ( SS 304 grade ) adjustable friction window stay of approved quality with necessary stainless steel screws etc. to the side hung windows etc. complete as per direction of Engineer-in-charge:-
118205 x 19 mm
119Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. of approved quality complete as per direction of Engineer-in-charge:-
120Anodised aluminium of grade AC 15.
121SUB-HEAD : FLOORING AND SKIRTING WORK
122Providing and fixing gang saw cut of approved thickness mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base of cement mortar 1:4 ( 1 cement : 4 fine sand ) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing , curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels:-:-
12314 mm thick Granite of any colour and shade duly approved:-Area of slab over 0.50 sqm.
124Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete
125Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 fine sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
12614 mm thick stone slab.
127Stone work in skirting, risers of steps and dado up to 2 m height over 12 mm thick bed of cement mortar 1:3 (1cement :3 fine sand) and jointed with grey cement slurry @ 3.3 kg/sqm, including pointing in white cement mixed with pigment of matching shade complete.
128Granite of any colour and shade duly approved of 8 mm thick
129Extra for prefinished nosing to treads of steps of Granite stone.
130Extra for granite stone flooring complete in treads of steps and risers using single length upto 2.00 metre.
131Providing and fixing stone slab with table rubbed, edges rounded and polished of size 75x50 cm deep and approved thickness fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth including rubbing, curing etc. complete at all levels as required (measurement should be of exposed finished work):-
132Granite of any colour and shade duly approved of 14 mm thick (75 x 50 cm)
133Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 - 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge..
134Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid)Size of tile 600 mm x 600 mm
135Extra for providing and laying Vitrified tiles (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622 - 2017, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. all complete as per direction of the Engineer-in-charge
136Providing and fixing Kota stone in floors over 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with ordinary cement slurry including pointing with ordinary cement mixed with pigment of matching shade, including rubbing and polishing complete.
137Kota stone slab 25mm thick
138Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1 : 3 ( 1 cement : 3 fine sand ) and joined with ordinary cement slurry mixed with pigment to match the shade of slabs, including rubbing and polishing complete.
139Providing and laying 1st class quality ceramic floor tiles in different sizes (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 - 2017 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid over 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc. all complete as per direction of the Engineer in-charge.
140Mat Finish Tiles/ Anti-skid Tiles/ Glossy Tiles600 mm x 600 mm in all shades and designs 1st class quality ceramic floor Porcelain tiles
141Providing and fixing 1st quality ceramic glazed wall tiles (minimum 200 x 300) conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) of approved make in all colours, shades of any size as approved by Engineer-in-charge in skirting, risers of steps and dados, laid over 12 mm thick bed of cement mortar 1 : 3 (1 cement : 3 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade complete.
142Providing and fixing Precast chequered cement concrete tiles 18 mm thick, laid in footpath & courtyard, on 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with neat cement slurry including rubbing and cleaning etc. all complete as per direction of Engineer-in-charge. In dark shade using ordinary cement
143Providing and fixing chequered terrazo tiles 22 mm thick with graded marble chips of size upto 6 mm, laid on floors, footpath & courtyard on 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and polishing etc. all complete as per direction of Engineer-in-charge. Light shade pigment using white cement
144Providing and laying cement concrete 1:2:4 (1 cement: 2 fine sand : 4 graded well burnt brick aggregate) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips and cost of glass strips etc. complete.
14540 mm thick
14660 mm thick factory made c.c. interlocking paver block of M-35 Grade
147Providing and laying factory made chamfered edge Cement Concrete paver blocks of required strength, thickness & size/ shape, made by table vibratory method to attain superior smooth finish using PU or equivalent moulds, laid in required grey colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks, lawns, drive ways or light traffic parking etc. all complete as per specifications & approval/ direction of the Engineer -in-Charge:(a) 60 mm thick c.c. paver block of M-35 grade with approved colour, design and pattern.
148SUB-HEAD : ROOFING AND CEILING WORK
149Supply & installation of pre-painted Galvalume sheets for roofing/cladding (size, shape and pitch of corrugation as approved by Engineer-in-charge) in 550mpa steel grade, made out of Cold Rolled Steel coated with Zinc-Aluminium alloy coating of 43.5% Zn, 55% Al and 1.5% Silicon confirming to ASTM A792/A792M and AS1397, Alloy coating AZ150/AZ70, colour coated with high quality Polyester coating, top coated of modified polyester of 20 micron, back side coat of 5 micron, having epoxy primer coat of 5 micron on both side. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required and as per direction of Engineer-in-charge.
1500.50 mm thickness
151Supply & installation of pre-painted Galvalume sheets roofing accessories in 550mpa steel steel grade, made out of Cold rolled steel coated with Zinc-Aluminium alloy coating of 43.5% Zn, 55% Al and 1.5% Silicon confirming to AASTM A792/A792M and AS1397, Alloy coating AZ150/AZ70, colour coated with high quality polyester coating, top coated of modified polyester of 20 micron, back side coat of 5 micron, having epoxy primer coat of 5 micron on both side etc. complete as per direction of Engineer-in-charge. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation. The sheet shall be fixed using self drilling /self tapping screws with EPDM washers complete for Ridges/Valley/Gutter/Flashing of width 610mm:
1520.50 mm thickness
153Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with
154recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern etc. complete as per direction of Engineer-in-charge. and as per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60.
155Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kg/cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge
156Single socketed pipe - 110 mm OD
157Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:
158(i) Coupler - 110mm
159(ii) Single equal tee with door - 110 x 110 x 110 mm
160(iii) Single equal tee without door - 110 x 110 x 110 mm
161(iv) Bend 87.5o - 110mm
162(v) Plain shoe - 110 mm
163Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing with cement mortar 1 : 4 (1cement : 4 fine sand) making good the wall etc. complete.
164110mm
165Providing and fixing to the inlet mouth of rain water pipe PTMT grating with thickness of 8mm and weighing not less than 100gm. complete.
166100mm
167SUB-HEAD : FINISHING WORK
16812 mm cement plaster of mix
169In cement mortar 1 : 4 ( 1 cement : 4 fine sand )
170In cement mortar 1 : 6 ( 1 cement : 6 fine sand )
17115 mm cement plaster on the rough side of single or half brick wall of mix:
172In cement mortar 1 : 6 ( 1 cement : 6 fine sand )
1736 mm cement plaster of mix:
174In cement mortar 1 : 3 ( 1 cement : 3 fine sand )
175Neat cement punning.
176Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour [Payment shall be made after submission of Test Certificate issued by the Manufacturer].
177Two coats
178Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :(i) New work ( two or more coats) over and including water thinnable priming coat with cement primer.
179Finishing walls with premium acrylic smooth exterior paint with Silicon additives of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :(i) New work ( two or more coats applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
180Applying priming coat: [Payment shall be made after submission of Test Certificate issued by the Manufacturer]
181With ready mixed pink primer of approved brand and manufacture on wood work ( hard & soft wood ).
182Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]: (i) Two or more coats on new work
183Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
184SUB-HEAD:WATER PROOFING WORK
185Grading roof for water proofing treatment complete as required as per direction of the Engineer-in-charge with :
186Cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size)
187Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound, as directed by Engineer-in-Charge and consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
188SUB-HEAD:MISCELLANEOUS
189Providing and fixing Corner Guard for columns at parking area size W 100 x H 800 x 8 mm colour black with yellow or white reflective stickers having body materials modified Themoplastics (Polymer Rubberized) fixed on wall & corner of column with six 2\\" screws
190Providing and Fixing Channeled Hi Density Fiber Board Wall Panel (woodworks) (WC01C28LUMW) perforated panels of width 128mm, thickness of 15mm and length 2440mm with minimum 830 kg/M³ density substrate with a laminated facing as per the approved shade/species & finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the visible surface has a “Helmholtz” fluted perforation of 4mm width and 28 mm visible panel each. The panels shall provide a fire reaction of Class of 1 as per Part 7 of BS 476. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece having NRC of 0.55. The panels shall be mounted on special aluminium splines using clips. Install wooden battens of section 50 mm x 50 mm or approved by the Architect on the solid wall horizontally using screws and plugs at spacing of 600 mm centre-Screw the aluminium-extruded keel for channeled wood works (GTPT001) over the lowest and second wooden batten at an on-centre distance of 600 mm. Install the first set of wooden panels by inserting the clips for border channeled woodworks (GTPT002) and insert the grove of the panel into the projecting flange of the aluminium clip. Continue installing rows of panels by inserting the tongue into the groove of the earlier inserted panel and progressively installing clips for inside channeled woodworks (GTPT003) into the next keel till the actual height is achieved. Use clips for borer channeled woodworks (GTPT002) to finish off the installation. Finish off the edges using wooden moulding of matching colour approved by the Architect, suitably fixed all complete as per drawings and specification and direction of the Engineer-in-Charge.
191SUB-HEAD : SANITARY WORKS
192Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :
193White Vitreous china Orrisa pattern W.C. pan of size 580x440 mm with integral type foot rests.
194Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :
195W.C. pan with ISI marked white solid plastic seat and lid
196Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively.
197Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe.
198Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings:
199Flat back wash basin of size 550x400mm.
200Providing and fixing kitchen sink including making all connections excluding cost of fittings.
201White glazed fire clay sink of size 600x450x250mm.
202Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
203(i) Semi rigid pipe - 32 mm dia
204(ii) Flexible pipe - 32 mm dia
205Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
206Providing and fixing 600x120x5mm glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
207Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour.
208450mm long towel rail with total length of 495mm, 78mm wide and effective height of 88mm, weighing not less than 170gms
209Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colours weighing not less than 105 gms
210Providing and fixing PTMT towel ring trapezoidal shape 215mm long, 200mm wide with a minimum distances of 37mm from wall face with concealed fittings arrangement of approved quality and colours weighing not less than 80 gms.
211Providing and fixing on wall face unplasticised Rigid PVC rain water, soil, waste & vent pipes (working pressure 6 kg / cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:
212Single socketed pipe - 110 mm OD
213Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:
214(i) Coupler - 110mm
215(ii) Single pushfit Coupler - 110mm
216(iii) Single equal tee with door - 110 x 110 x 110 mm
217(iv) Single equal tee without door - 110 x 110 x 110 mm
218(v) Double equal junction of required degree without door - 110 x 110 x 110 mm
219(vi) Double equal junction of required degree with door - 110 x 110 x 110 mm
220(vii) Bend 87.5o - 110mm
221(viii) Plain shoe - 110 mm
222Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC soil, waste & vent pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing with cement mortar 1 : 4 (1cement : 4 fine sand) making good the wall etc. complete.(i) 110 mm
223Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size ) including necessary plaster and pointing in cement mortar 1:4(1cement: 4 coarse sand):100 mm dia.
224SUB-HEAD : WATER SUPPLY
225Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. - Internal work - Exposed on wall
22615 mm nominal outer dia .Pipes.
22720 mm nominal outer dia .Pipes.
22825 mm nominal outer dia .Pipes.
22940 mm nominal outer dia .Pipes.
23050 mm nominal outer dia .Pipes.
231Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. - Concealed work including cutting chases and making good the walls etc.
23215 mm nominal outer dia .Pipes.
23320 mm nominal outer dia .Pipes.
234Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. - External work
23515 mm nominal outer dia .Pipes.
23620 mm nominal outer dia .Pipes.
23725 mm nominal outer dia .Pipes.
23840 mm nominal outer dia .Pipes.
23950 mm nominal outer dia .Pipes.
240Providing and fixing brass bib cock of approved quality :
24115 mm nominal bore
242Providing and fixing brass stop cock of approved quality :
24315 mm nominal bore
244Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end):
24525 mm nominal bore
24640 mm nominal bore
247Providing and fixing gun metal non-return valve of approved quality (screwed end):
248(i) 25 mm nominal bore - Vertical
249(ii) 40 mm nominal bore - Vertical
250Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
251Constructing masonry Chamber 30x30x50 cm, inside , in brick work in cement mortar 1:4 (1 cement :4 fine sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design :
252With Second Class bricks
253Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :
25415 mm nominal bore.
25520 mm nominal bore.
25625 mm nominal bore.
25740 mm nominal bore.
258Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:
259100 mm diameter
260Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements weighing not less than 106 gms.
261SUB HEAD : SEWAGE AND DRAINAGE WORKS
262Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the of 1:1 (1 cement: 1 fine sand) including testing of joints etc. complete :
263150 mm diameter
264Providing and laying cement concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) alround S.W. pipes including bed concrete as per standard design:
265150 mm diameter S.W, pipe
266Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with well burnt 2nd class bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
267Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 1st class bricks in cement mortar 1:4 (1 cement : 4 fine sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 fine sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 fine sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :
268Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets :
269Extra for depth beyond 450 mm of brick masonry chamber for underground C.I. inspection chamber with same specification as mentioned in item no 20.330 complete as per standard design :
270For 500x700 mm size Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58617890
AUTHORITY Government Departments
TENDER VALUE 7.43 Crore
LAST DATE 04-12-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of Office Building (G+2 Storied) Of Dws Division Kalyanpur With Foundation Provision For (G+3)Storey At Kalyanpur Dws Office Premises Under Kalyanpur Block Area, Khowai District, Tripura./Sh:- Building Portion Including Internal Water Supply, Sanitary Installation, Sewage , Drainage Works Including Boundary Wall.
Basic Detail
Tender No CE (Buildings)/PWD/ACE/Project Unit/DNIT/55/2026-27
Bidding Type Tender
Location
City Khowai
State Tripura
Key Dates
Publish Date 19 Nov 2026
Submission Date 04 Dec 2026
Open Date 04 Dec 2026
Finance
Tender Value 7.43 Crore
Tender Fee 10000
EMD 14.87 Lakhs
Exemption Not Available
Document List
399f43a0-17cd-4300-b03c-87193de067d4.html
BOQ_80505.xls
DNIET.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Dec 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

399f43a0-17cd-4300-b03c-87193de067d4.html

xls

BOQ_80505.xls

pdf

DNIET.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender