Tender For Upgradation Of Deteriorated Shops Into A Double Storey Shopping Complex / Mini Super Bazar At Sudhmahadev, Udhampur. (Under Capex Budget 2026-27)
Tender Value
38.71 Lakhs
Estimated cost
Bid Submission
27 Nov 2026
7 days left
EMD
77420
Bank guarantee accepted
Document Fee
600
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Udhampur → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Upgradation Of Deteriorated Shops Into A Double Storey Shopping Complex / Mini Super Bazar At Sudhmahadev, Udhampur. (Under Capex Budget 2026-27)
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: 25 meter beyond 1 m from cutting edge All kinds of soil : |
| 2 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: 25 meter beyond 1 m from cutting edge: ordinary rock. |
| 3 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: 25 meter beyond 1 m from cutting edge: Hard Rock (Blasting Prohibited). |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 6 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 7 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size. |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto/above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases of columns for mass concrete. |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platforms. |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for: Columns, pillars, piers, abutments, posts and struts. |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for: Stairs (excluding landings) except spiral staircases. |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for: Edges of slabs and breaks in floors and walls Under 20 cm wide. |
| 16 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 17 | Brick work with common burnt clay F.P.S (Non-modular) brick of class designation 7.5 in foundation and plinth in 1:6 (1 cement : 6 coarse sand). |
| 18 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level. |
| 19 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 20 | Extra for half Brick masonry in superstructure above plinth level upto floor V level. |
| 21 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 22 | 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 ( 1 cement 6fine sand ) |
| 23 | 12mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 coarse sand) |
| 24 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick. |
| 25 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm). |
| 26 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer. |
| 27 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size). |
| 28 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 29 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, laid on 20 mm thick cement mortar 1:4 (1Cement : 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown. |
| 30 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of size 300x450mm as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 31 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm. |
| 32 | Providing and fixing factory made uPVC white colour sliding glazed windowabove 1.50 m in height dimension comprising of uPVC multichambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads, uPVC extruded interlocks and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle on one side of extreme panel along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) touch lock with hook (if required for wire mesh panel), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rodof required size and of approved quality, all complete as per approved drawing & direction of Engineer-in Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 2.50 sqm upto 4.00 sqm.) |
| 33 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): SAL WOOD. |
| 34 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 35 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work |
| 36 | Providing and fixing factory made flush door shutters 30 mm thick made of pre-laminated flat pressed three layer particle board conforming to IS: 12823 exterior grade (Grade I Type II) having one side decorative lamination of approved shade and other side balancing lamination including second class teak wood lipping of 25mm widex12mm thick with necessary screws and black enameled M.S. butt hinges complete as per directions of Engineer- in-charge. |
| 37 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300x16 mm. |
| 38 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 150x10 mm. |
| 39 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 125MM. |
| 40 | Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 9.103.1 Single rubber stopper. |
| 41 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. @2kg /sft. |
| 42 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube @1kg /sft. |
| 43 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutters. 80x0.90 mm M.S. laths with 0.90 mm thick top cover. |
| 44 | Carriage of Sand by mechanical transport including loading , unloading & stacking complete lead upto 85 km & manual means lead upto 50 mtr. |
| 45 | Carriage of stone aggregate below 40 mm nominal size by mechanical transport including loading, unloading & stacking complete lead upto 40 km & manual means lead upto 50 mtr. |
| 46 | Carriage of bricks by mechanical transport including loading, unloading & stacking complete lead upto 120 km & MANUAL BY 50M |
| 47 | Carriage of EARTH by MANUAL transport including loading, unloading & stacking complete lead upto 50M |
| 48 | Dismantling: Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge. |
| 49 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar . |
| 50 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: |
| 51 | Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 meters lead : Thickness above 25 mm upto 40 mm. |
| 52 | Engaging of labour for dismantling truss and other components as per diection of Enigneer-In-Charge |
| 53 | Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.:All kinds of soil |
| 54 | Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material : |
| 55 | Centering shuttering including strutting, propping etc. and removal of form work for: Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 56 | Providing and fixing white vitreous china pedestal type water closet (European type W.C . .pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern including flush pipe with manually controlled device (handle lever) conforming to IS:7231, with all fittings and fixtures, complete including cutting and making good the walls and floors wherever requied W.C. pan with lSI marked white solid plastic seat and lid. |
| 57 | Providing and fixing wash basin with C. I./M.S. brackets,15mm C.P. centre hole basin mixture, 32 mm C.P. brass waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required White Vitreous China round wash basin size 405x355 mm with a pair of 15 mm C.P. brass pillar taps. |
| 58 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 59 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour:Waste coupling 38mm of 83 mm length and 77 mm breadth weighing not less than 60gms. |
| 60 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610 x 510 mm bowl depth 200mm. |
| 61 | Providing and fixing P.V.C waste pipe for sink or wash basin including P.V.C waste fitting complete. Flexible pipe 40 mm dia. |
| 62 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour:Waste coupling 38mm of 83 mm length and 77 mm breadth weighing not less than 60gms. |
| 63 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 75 mm diametre |
| 64 | Providing and fixing unplasticised - Rigid PVC PIPES conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap of thermal expansion;with necessary stays / clamps with fasteners having working pressure of 4kg/cm2 all complete including testing of joints and pipes for leakage etc.:- 110 mm dia. |
| 65 | Providing and fixing unplasticised - PVC moulded fittings / accessories for unplasticised - Rigid PVC pipes conforming to IS : 13592 Type A including jointing with seal ring & insertion rubber washer 3 mm thick conforming to IS : 5382 leaving 10mm gap for thermal expansion; with necessary stays / clamps with fasteners bolts and nuts complete; having working pressure of 4kg/cm2:- all complete including testing of joints and pipes for leakage etc.:- PVC PLAIN BEND (of required degree):-75 mm dia. |
| 66 | Providing and fixing unplasticised - PVC moulded fittings / accessories for unplasticised - Rigid PVC pipes conforming to IS : 13592 Type A including jointing with seal ring & insertion rubber washer 3 mm thick conforming to IS : 5382 leaving 10mm gap for thermal expansion; with necessary stays / clamps with fasteners bolts and nuts complete; having working pressure of 4kg/cm2:- all complete including testing of joints and pipes for leakage etc.:- PVC PLAIN BEND (of required degree):-110 mm dia. |
| 67 | Providing and fixing unplasticised - PVC moulded fittings / accessories for unplasticised - Rigid PVC pipes conforming to IS : 13592 Type A including jointing with seal ring & insertion rubber washer 3 mm thick conforming to IS : 5382 leaving 10mm gap for thermal expansion; with necessary stays / clamps with fasteners bolts and nuts complete; having working pressure of 4kg/cm2:- all complete including testing of joints and pipes for leakage etc.:- PVC DOOR BEND( of required degree):-75 mm dia. |
| 68 | Providing and fixing unplasticised - PVC moulded fittings / accessories for unplasticised - Rigid PVC pipes conforming to IS : 13592 Type A including jointing with seal ring & insertion rubber washer 3 mm thick conforming to IS : 5382 leaving 10mm gap for thermal expansion; with necessary stays / clamps with fasteners bolts and nuts complete; having working pressure of 4kg/cm2:- all complete including testing of joints and pipes for leakage etc.:- PVC DOOR BEND( of required degree):-110 mm dia. |
| 69 | Providing and fixing unplasticised - PVC moulded fittings / accessories for unplasticised - Rigid PVC pipes conforming to IS : 13592 Type A including jointing with seal ring & insertion rubber washer 3 mm thick conforming to IS : 5382 leaving 10mm gap for thermal expansion; with necessary stays / clamps with fasteners bolts and nuts complete; having working pressure of 4kg/cm2:- all complete including testing of joints and pipes for leakage etc.:- PVC PLAIN TEE 75 mm dia. |
| 70 | Providing and fixing unplasticised - PVC moulded fittings / accessories for unplasticised - Rigid PVC pipes conforming to IS : 13592 Type A including jointing with seal ring & insertion rubber washer 3 mm thick conforming to IS : 5382 leaving 10mm gap for thermal expansion; with necessary stays / clamps with fasteners bolts and nuts complete; having working pressure of 4kg/cm2:- all complete including testing of joints and pipes for leakage etc.:- PVC PLAIN TEE 110 mm dia. |
| 71 | Providing and fixing unplasticised - PVC moulded fittings / accessories for unplasticised - Rigid PVC pipes conforming to IS : 13592 Type A including jointing with seal ring & insertion rubber washer 3 mm thick conforming to IS : 5382 leaving 10mm gap for thermal expansion; with necessary stays / clamps with fasteners bolts and nuts complete; having working pressure of 4kg/cm2:- all complete including testing of joints and pipes for leakage etc.:- PVC REDUCER PLAIN TEE:- 110 mm x 75 mm. |
| 72 | Providing and fixing unplasticised - PVC moulded fittings / accessories for unplasticised - Rigid PVC pipes conforming to IS : 13592 Type A including jointing with seal ring & insertion rubber washer 3 mm thick conforming to IS : 5382 leaving 10mm gap for thermal expansion; with necessary stays / clamps with fasteners bolts and nuts complete; having working pressure of 4kg/cm2:- all complete including testing of joints and pipes for leakage etc.:- PVC OFFSET 75 mm dia. |
| 73 | Providing and fixing unplasticised - PVC moulded fittings / accessories for unplasticised - Rigid PVC pipes conforming to IS : 13592 Type A including jointing with seal ring & insertion rubber washer 3 mm thick conforming to IS : 5382 leaving 10mm gap for thermal expansion; with necessary stays / clamps with fasteners bolts and nuts complete; having working pressure of 4kg/cm2:- all complete including testing of joints and pipes for leakage etc.:- PVC OFFSET 110 mm dia. |
| 74 | Providing and fixing unplasticised - PVC moulded fittings / accessories for unplasticised - Rigid PVC pipes conforming to IS : 13592 Type A including jointing with seal ring & insertion rubber washer 3 mm thick conforming to IS : 5382 leaving 10mm gap for thermal expansion; with necessary stays / clamps with fasteners bolts and nuts complete; having working pressure of 4kg/cm2:- all complete including testing of joints and pipes for leakage etc.:- PVC COUPLER /COLLAR 75 mm dia. |
| 75 | Providing and fixing unplasticised - PVC moulded fittings / accessories for unplasticised - Rigid PVC pipes conforming to IS : 13592 Type A including jointing with seal ring & insertion rubber washer 3 mm thick conforming to IS : 5382 leaving 10mm gap for thermal expansion; with necessary stays / clamps with fasteners bolts and nuts complete; having working pressure of 4kg/cm2:- all complete including testing of joints and pipes for leakage etc.:- PVC COUPLER /COLLAR 110 mm dia. |
| 76 | Providing and fixing unplasticised - PVC moulded fittings / accessories for unplasticised - Rigid PVC pipes conforming to IS : 13592 Type A including jointing with seal ring & insertion rubber washer 3 mm thick conforming to IS : 5382 leaving 10mm gap for thermal expansion; with necessary stays / clamps with fasteners bolts and nuts complete; having working pressure of 4kg/cm2:- all complete including testing of joints and pipes for leakage etc.:- PVC VENT COWL:-110mm dia . |
| 77 | Providing and fixing unplasticised - PVC moulded fittings / accessories for unplasticised - Rigid PVC pipes conforming to IS : 13592 Type A including jointing with seal ring & insertion rubber washer 3 mm thick conforming to IS : 5382 leaving 10mm gap for thermal expansion; with necessary stays / clamps with fasteners bolts and nuts complete; having working pressure of 4kg/cm2:- all complete including testing of joints and pipes for leakage etc.:- PVC FLOOR /NAHANI TRAP:-110 mm x 75 mm |
| 78 | Providing and fixing unplasticised - PVC moulded fittings / accessories for unplasticised - Rigid PVC pipes conforming to IS : 13592 Type A including jointing with seal ring & insertion rubber washer 3 mm thick conforming to IS : 5382 leaving 10mm gap for thermal expansion; with necessary stays / clamps with fasteners bolts and nuts complete; having working pressure of 4kg/cm2:- all complete including testing of joints and pipes for leakage etc.:- PVC FLOOR /NAHANI TRAP:-110 mm x 100 mm |
| 79 | Providing and fixing (C.P. Brass ) towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms. |
| 80 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete ISI marked as approved by Engineer incharge at site |
| 81 | Providing and fixing 100 mm CP grating (hole or without hole) for gully, floor or Nahani trap.ISI marked all complete . |
| 82 | Providing and fixing Soap dish (C.P. brass) with brackets ,nuts & screws complete etc. |
| 83 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia. |
| 84 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms a) 15 mm nominal bore. |
| 85 | Providing and fixing C.P. brass stop cock ( concealed) of standard design and of approved make concorming to IS : 8931 a) 15 mm nominal bore. |
| 86 | Providing and fixing C.P. brass angle valve for basin/ wall mixer and geysers points of approved make conforming to IS : 8931 15 mm nominal bore as approved by site incharge. |
| 87 | Providing and fixing G.l. pipes complete with G.l. fittings and h0oks, including cutting and making good the walls etc.(internal work) as approved by site incharge -Exposed on wall) all complete including testing of pipes and fittings and joints for leakage with pressure pump etc.15 mm dia. nominal bore (medium). |
| 88 | Providing and fixing G.l. pipes complete with G.l. fittings and h0oks, including cutting and making good the walls etc.(internal work) as approved by site incharge -Exposed on wall) all complete including testing of pipes and fittings and joints for leakage with pressure pump etc.25 mm dia. nominal bore (medium). |
| 89 | Making connection of G.l. distribution branch with G.l. main of following sizes by providing and fixing Tee, including cutting and threading the pipe etc. complete all complete including testing of pipes and fittings and joints for leakage with pressure pump etc. as approved by site incharge 25 to 40 mm nominal bore. |
| 90 | Providing and fixing G.l. Union in G.l. pipe including cutting and threading the pipe and making long screws etc. complete (new work) all complete including testing of pipes and fittings and joints for leakage with pressure pump etc.as approved by site incharge 25 mm nominal bore. |
| 91 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank lSI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 92 | Providing and fixing G.I.TANK NIPPLE of suitable dia. as approved by engineer incharge at site all complete including testing of fittings and joints for leakage etc.:- 32 mm dia. nominal bore. |
| 93 | Providing & fixing BRASS BALL VALVE of approved quality conforming to IS : 8931 as approved by site incharge 25 mm nominal bore. |
| 94 | Providing & fixing BRASS BALL VALVE of approved quality conforming to IS : 8931 as approved by site incharge 40 mm nominal bore. |
| 95 | Providing & Installation of 1.5 H.P. three phase water pump of make Crompton with all fittings, connecting inlet & outlet, fixtures, electrical connection and starter all complete:- |
| 96 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) R.C.C. top slab with 1 :2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finsihed with a floating coat of neat cement complete as per standard design Inside size 90x80 cm and 45 cm deep including C.l. cover with frame (light duty) 455x610 mm. internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg):- With F.P.S. bricks with class designation 75 & with Crushed stone aggregate. |
| 97 | Making soak pit 2.5 m diameter 3.0 metre deep with 45x45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design by way of earth excavation by mechanical means; laying of 100 mm thick P.C.C. bed in 1:4:8 mix ratio & R.C.C. Slab on top in 1:1.5:3 mix ratio; providing and fixing of Manhole with MS frame and cover having passing of 50 mm dia. Vent air pipe through it for foul gases; brick masonry in 1:6 cement mortar mix with providing of pores; and filling of brick bat aggregates around the dry brick honey comb shaft; P/F of pvc bend/tee at the S.W. Drain pipe; all complete etc:- With F.P.S. bricks and Crushed. |
| 98 | Supply & fixing CI cover with frame for manhole in sump / septic Tank 455 x 610 mm rectangular CI cover ( light duty ) the weight of the cover to be not less than 23 kg. |
| 99 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A. |
| 100 | Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required. 2 X 2.5 SQ.MM + 1 X 2.5 SQ.MM Earth Wire. |
| 101 | Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required. 2 X 4.0 SQ.MM + 1 X 4.0 SQ.MM Earth Wire. |
| 102 | Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required. 4 X 6.0 SQ.MM + 2 X 6.0 SQ.MM Earth Wire. |
| 103 | Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required. 4 X 16.0 SQ.MM + 2 X 6.0 SQ.MM Earth Wire. |
| 104 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1 x 1.5 sq. mm |
| 105 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair. |
| 106 | Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non- Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required. 1 run of cable. |
| 107 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm. |
| 108 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch. |
| 109 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet. |
| 110 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch. |
| 111 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 socket outlet. |
| 112 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet. |
| 113 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Computer Socket (RJ45). |
| 114 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Bell Push. |
| 115 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 116 | Supplying and fixing modular blanking plate on the existing modular plate and Switch box excluding modular plate as required. |
| 117 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) |
| 118 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm) |
| 119 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 4 Module (125mmX75mm) |
| 120 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm) |
| 121 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mmX125mm) |
| 122 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.12 Module (200mmX150mm) |
| 123 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 124 | Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required. |
| 125 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 126 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings. |
| 127 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 128 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door. |
| 129 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door. |
| 130 | Supplying and fixing following rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole 6 to 32 Amp. |
| 131 | Supplying and fixing following rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral 6 to 32 Amp. |
| 132 | Supplying and fixing following rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral 6 to 32 Amp. |
| 133 | Supplying and fixing following rating, Four pole, 415 V, 10 Ka M.C.B in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A TPN MCB 10 Ka \\"C\\" Curve |
| 134 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 135 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 136 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 137 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 138 | LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 40 watt. |
| 139 | Supply installation testing and commissioning of Ceiling Fan 3 Star Rated with Voltage Range 90 V to 300 V,Min. Air Delivery 212 CMM,Service Value 5.3 Cu.m/min/watt, Aluminium Blades ,including wiring the down rods of standard length(Upto 45 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required. 1200 MM |
| 140 | LED Down lighter (SMD Type) (System lumen efficacy ≥120<135lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . 18 watt |
| 141 | Supplying and fixing of following sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire. 300mm/12\\" sweep exhust fan. |
| 142 | Supply installation testing and commissioning of IP:20 Aluminium Batten 10W-12 W +- 1 W LED Surface Mounted 2 ft. with system lumen efficacy of 100 lm/W and P.F >0.9 THD <20% CCT 6500K,CRI 80 .The LED should have life of 50000 Burning Hours at L70.The input voltage shall be 150 V to 270 V.The fixture should have inbuit surge protection of 2KV.Certification-LM 79 and LM 80.The test report should be from Govt. Approved Lab/inhouse NABL Lab. |
| 143 | SITC of Building Distribution Panel Indoor (IP:42) free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge. |
| 144 | INCOMER 100 Amp, 36 KA, FP MCCB ICU = 100% ICS |
| 145 | INCOMER Aluminium Bus Bar 200 Amp set of 4 strips 18\\". |
| 146 | INCOMER Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc. |
| 147 | OUTGOINGS ON Load Change Over Switch FP 100 amp. (Front operated). |
| 148 | OUTGOINGS 63 A TPN MCB 10 Ka \\"C\\" Curve. |
| 149 | OUTGOINGS 32 A TPN MCB 10 Ka \\"C\\" Curve. |
| 150 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal). |
| 151 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand cushioning, protective covering and refilling the trench etc as required. 3.5 C X 70 Sq.mm A2XFY. |
| 152 | Supply and Making end Termination with Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required (Comet) 3½ X 70 sq. mm (50mm). |
| 153 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 m m dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 154 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run). |
| 155 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run). |
| 156 | Supply, installation, testing and commissioning of Junction Boxes/DB-10 Pairs with Original Krone module and Back Mount Frame and have Lock -n- key, complete in all respect as per specification and desired by EIC. |
| 157 | Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. 9 U Rack. |
| 158 | Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. Copper Patch Cords of length 1m (3ft). Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysNov 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender