Tender For Tender For Proposed Interior Civil And Electrical Infrastructure Work In The Tomotherapy Bunker At Government Arignar Anna Memorial Cancer Research Institute & Hospital, Karapettai, Kanchipuram.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
07 Dec 2026
16 days left
EMD
50000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kanchipuram → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Tender For Proposed Interior Civil And Electrical Infrastructure Work In The Tomotherapy Bunker At Government Arignar Anna Memorial Cancer Research Institute & Hospital, Karapettai, Kanchipuram.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls |
| 2 | Brick / stone masonry in Cement mortar walls under 3m high |
| 3 | Dismantling RCC |
| 4 | Dadooing walls in cement mortar with glazed tiles |
| 5 | Chipping of concrete & roughening the surface |
| 6 | Plastering the surface of walls with Cement Mortar 1:3 (One cement and Three plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc., complete complying with standard specification and as directed by the departmental officers. |
| 7 | Providing Granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two M-sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 8 | Paving the floor with best quality Vertified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three crushed stone sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 9 | Supplying and fixing with new Bison board wall panalling using aluminium box section and aluminium frame at an interval of 0.60m at the aluminium frame of size 63.50mmx38.10mmx1.28mm ,1.41mm @ 0.818kg/m with necessary 'L' Angles, screws, nails and fixed in the wall using drilling machine with neat straight alignments etc., after finishing the frame work and fixed with 10mm thick Bison Board of approved quality and ISI make and top finished with 5mm thick polygranite sheet of necessary screws naisl, favicol and necessary instruction of the departmental officers and also cutting the wall partition for Electrical Switch box and AC Plug Box and telephone Box requirements and finally cleaning the partition for both side with neat position etc., The rate is inclusive of cost of materials, labour charges aluminium frame work and partiton work , transporting charges etc., complete as directed by the departmental officers., (The materials quality and colours are approved by the departmental Engineer before use of works) |
| 10 | Supplying and fixing with new Bison board partition using aluminium box section and aluminium frame at an interval of 0.60m at the aluminium frame of size 63.50mmx38.10mmx1.28mm ,1.41mm @ 0.818kg/m with necessary 'L' Angles, screws, nails and fixed in the wall using drilling machine with neat straight alignments etc., after finishing the frame work and fixed with both side 10mm thick Bison Board of approved quality and ISI make and top finished with 5mm thick polygranite sheet with necessary screws naisl, favicol and necessary instruction of the departmental officers and also cutting the wall partition for Electrical Switch box and AC Plug Box and telephone Box requirements and finally cleaning the partition for both side with neat position etc., The rate is inclusive of cost of materials, labour charges aluminium frame work and partiton work , transporting charges etc., complete as directed by the departmental officers., (The materials quality and colours are approved by the departmental Engineer before use of works) |
| 11 | Supplying and installing a storage cupboard with shutters, made of 16mm commercial plywood and finished with laminate on all sides. The visible edges will be covered with edge beading wherever necessary. The rate includes the cost of materials, transportation, hardware, and labor charges. |
| 12 | Supplying and installing a workstation made of 16 mm thick commercial plywood, laminated on both sides with 1 mm thick mica laminate, complete with edge beading and necessary finishing. The workstation shall be supported by suitable angular brackets fixed securely to the wall at the bottom, fabricated from 32 mm thick commercial plywood laminated on both sides with 1 mm thick mica laminate, including all necessary additional accessories, fittings and fasteners. The bottom portion of the workstation shall be provided with suitable storage units and a sliding keyboard tray, complete with necessary hardware and accessories. The rate shall be inclusive of the cost of all materials, labour charges, transportation, fabrication, installation, fixing, finishing and all incidental expenses required to complete the work in all respects as directed by the Departmental Officers. |
| 13 | Medium back cushion rolling chair with seat & back made of molded cushion, hydraulic type and mateal base. The rate is inclusive of cost of mateirals, transport, hardware, labour charges |
| 14 | Plastic chair with arms, Brand- Nilkamal, Model- Heritage |
| 15 | Supply & fixing of Gypsum board false ceiling using 10 mm thick of approved quality and design suspended from the ceiling up to a ceiling height of 4.50m from floor level using 'U'shaped galvanised iron channel of size 25x25x0.55mm thick at 1.20m centre on both longitudinal and cross direction for vertical support and fixing 'U' shaped G.I channel of size 50x30x0.55mm thick at 0.90m c/c on longitudinal direction respectively for horizontal support by using T.W reepers at corners and at intermediately fixing of plaster of paris on the panel provided as per design / pattern given by the site officer and finishing the ceiling surface with same plaster of paris materials etc. Necessary opening should be covered with acrylic panel complying with std. specification and as directed by the deptl officers etc., complete cost including all materials such as rawl plugs, bolts and nuts, G.I pipes, metal star screws, paper tape, jointing components etc complete. All the materials should be got appd. before use on work by the Executive Engineer. |
| 16 | Supplying and Installing Metal False Ceiling using Fire Retardant Galvanized Steel Sheet Plain lay in tile size 600mm x 600mm, 0.5mm thick, powder coated on external surface and shall have flange on all four sides to rest on the exposed grids. The system to give 600mm x 600mm centre to centre ‘T’. The ‘T’ shall be not be dipped GI Tee Section 3600mm long main Tee. 24mm wide and cross Tee panels are formed by running main runner of ‘T’ section of size 30mm x 24mm powder coated at bottom at intervals with powder coating at bottom. Necessary provision of inter locking of ‘T’ section are made at required intervals not exceeding 1200mm. The main runners are suspended from the ceiling by means of 4mm dia. GI rods fixed to the ceiling using anchor fasteners of 50mm x 8mm size with nylon inset and hooked to the main rubbers using clips. The last hangers at end of each rubber should not be greater than 600mm from the adjacent wall. The last panel shall be placed at the side wall using edge profile ‘L’ Angle of size 20mm x 20mm and fixed to the side wall the false ceiling should be fixed of same level and should present a neat look |
| 17 | Supplying and painting the walls with two coats of wall putty as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications (The wall putty shall be got approved by the Executive Engineer before use of work). |
| 18 | Painting the wall two coats with approved Emulsion paint over one primer coat on cement plastered wall surface ect., complete complying with standard specification and as directed by the departmental officers. |
| 19 | Dadooing walls with following best approved quality, Double charged Vertified Tiles 600 x 600 x 8mm tiles in Cement Mortar 1:2 (One Cement and Two sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. |
| 20 | Brick work in Cement Mortar 1:5 using best quality Burnt Clay Brick of size 9\\" x 4 1/2\\" x 3\\" with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge. |
| 21 | Fabricating Supplying and fixing in position of Aluminium anodised natural colour matt finish 1/3rd fixed glazing 2/3rd prelaminated board of Aluminium partition of size 2.70 mx 2.10 m.The outer frames Outer frame: 63.50x38x3mm@ 1.72 kg/m,Centre mullions: 63.50x38x3mm@ 1.55 kg/m,Alu. Clips: 17.27x17.15x1.50mm @ 0.175kg/mg/m for intermediate vertical mullion 90cm c/c. Horizontal mullion at 1.00m 2.10m covered with 5.5 mm thick plain glass with neccessary aluminium clips of size 17.27x17.15 x1.50mm @ 0.176kg/m and with required rubber beading etc., including necessary dismantling holes in RCC column,masonry wherever in necessary with power drills to the extent required and made good the damaged portion in good condition after fixing etc... complete complying with standard specification and as directed by the deparmental officers. All the aluminium sections should be anodised not less than 15 microns as ISI specification1868/1962 / and should be gotapproved by Executive Engineer before use. |
| 22 | Fabricating Supplying and fixing in position of Aluminium anodised natural colour matt finish of single leaf door with half panelled with 12mm thick both side laminated particle board at bottom and half glazed using 5.50mm thick Plain glass at top.The outer frame shall be with aluminium box section 101.60x44.45x3.18m at 2.319kg/m and Shutter frame made of section Vertical & Top rail: 50x44.45x2.50mm @ 1.292 kg/m ,Bottom rail: 100 x44.45 x 2.50mm@ 1.974 kg/m, Lock rail : 50x44.45x2.5mm @ 1.292 kg/m, Alu Clips: 17.15x17.27x1.50mm @ 0.176 kg/m,Alu. Handle: 100x30mm @ 0.988 Kg/m and necessary accessories such as aluminium clips, rubber beading, PVC felt, handle for a length of shutter (both sides), locking arrangements, furniture fittings such as aluminium tower bolts-250x12mm - Each., aluminium tower bolt 200x12mm - 1No., aluminium Hydraulic door closer - 1No ., lock-1No., Door stopper with rubber bush including cost of materials labour charges and power consumption charges required for fabrication including chipping, dismantling and making hole to the required extent in RCC column, beams, masonry with power drill wherever necessary and redoing the damaged portion to the original condition after fixing etc., complete complying with standard specification and as directed by the deparmental officers. All the Alu. Section are to be anodised with matt finish under electricaly controlled conditions in accordance with IS 1868/1962 for an average anatic film thickness of 15 microns etc., complete.Aluminium sections,and furniture fittings shall be got approved by the Executive Engineer incharge. |
| 23 | Supplying, fabricating and fixing in position of Aluminium anodised natural colour matt finish of double leaves door with half panelled with 12mm thick bothside prelaminated partile board at bottom and half glazed using 5.50mm thick Plain glass at top.The outer frame shall be with aluminium box section 101.60x44.45x3.18m at 2.319kg/m and Shutter frame made of section-Vertical &Top rail: 50x44.45x2.50mm @ 1.292 kg/m and Bottom rail : 100 x 44.45 x 2.50mm @ 1.974 kg /m , Lock rail : 50x44.45x2.5mm @ 1.292 kg/m,Alu. Clips: 17.15x17.27x1.50mm @ 0.176 kg/m Alu. Handle: 100x30mm @ 0.988 kg/m and necessary accessories such as aluminium clips, rubber beading, PVC felt, handle for a length of shutter (both sides), locking arrangements, furniture fittings such as aluminium tower bolts-250x12mm - 2 Nos., aluminium tower bolt 200x12mm - 1No., aluminium Hydraulic door closer - 2Nos ., lock-1No., Door stopper with rubber bush including cost of materials, labour charges and power consumption charges required for fabrication including chipping, dismantling and making hole to the required extent in RCC column, beam masonry with power drill wherever necessary and redoing the damaged portion to the original condition afterfixing etc. complete complying with standard specification and as directed by the deparmental officers.. All the Alu. sections are to be anodised with matt finish under electically contolled condition in accordance with IS 1868/1962 for an average anodic film thickness of 15 microns etc., complete.Aluminium sections,and furniture fittings shall be got approved by the Executive Engineer incharge. |
| 24 | Providing, supplying and fixing a lead-lined wooden sandwich door for radiation-protected room, comprising a solid wooden door frame and shutter constructed with suitable timber members and sandwich-type wooden panels incorporating 1.2 mm thick lead sheet lining, ensuring continuous lead shielding throughout the door leaf with properly overlapped and sealed joints to prevent radiation leakage. The door shall be complete with suitable wooden door frames of size 105 mm × 57 mm, fabricated from 18-gauge sections, and necessary reinforcement to support the weight of the lead-lined shutter. The door shall be provided with SS 304 ball-bearing butt hinges of size 101 mm × 75 mm × 3 mm, mortice sash lock ML 100A, 50 mm backset, 85 mm centre, CL 207, key and knob, 70 mm, 5-pin cylinder with SS-finish handle of Dorma make, heavy-duty door closer and all necessary hardware, accessories and fittings. The door frame shall be securely fixed to the wall using suitable fasteners, ensuring proper alignment, level, plumb and smooth operation. The work shall include fabrication, lead lining, wooden sandwich shutter construction, installation, fixing, finishing, transportation, labour charges and all necessary materials and accessories, complete in all respects as per the approved specifications, radiation-shielding requirements and instructions of the Departmental Officers. The materials, make, quality and finish shall be subject to approval by the Departmental Engineer before commencement of the work. |
| 25 | Design, supply, fabrication and installation of a customised decorative false ceiling with a high-resolution natural scenic theme, incorporating realistic visual effects to create an immersive, aesthetically appealing and nature-inspired ambience. The work shall include the design and preparation of the scenic ceiling layout, provision and installation of a suitable metal supporting framework, fabrication and fixing of ceiling panels with high-quality digitally printed scenic graphics, depicting natural elements effects, as per the approved design. The scope shall also include the provision and integration of suitable LED lighting fixtures to enhance the visual depth, colour vibrancy and overall scenic effect, along with all necessary electrical connections, wiring, accessories, supports, fasteners and related components. The contractor shall ensure proper levelling, alignment, joint treatment, edge detailing and finishing of all ceiling elements to achieve a uniform, seamless and visually continuous appearance. The complete installation shall be carried out in accordance with approved drawings, specifications and site conditions, including all labour, materials, tools, equipment, transportation and incidental works required to deliver a fully finished and operational decorative scenic false ceiling. |
| 26 | Supply and installation of brass letters and brass emblems as per the design specified by the departmental officer. The rate should includes the cost of labor, materials, transportation, drilling, scaffolding, and any other associated charges. (a) English Brass letters |
| 27 | Supply and installation of Open steel racks 2000 mm x 450 mm x 900 mm, Angles – 40 mm x 40 mm x 1.6 thickness ,Panels are made out of 0.9 mm thickness. Rate inclusive of materila, Transportation charges, installation charges etc., |
| 28 | Supply and installation of acrylic name boards for each room according to the design and content specified by the departmental officers. The rate inclusive of materials, labor for manufacturing, transportation, and installation charges etc., |
| 29 | Supply and Installation of 1.5 TR capacity 3 star rated energy efficient Hi wall mounting Split type Air Conditioner unit consisting of out door condensing unit complete with hermetically sealed Air compressor with R 22 refrigerant air cooled condenser, fan etc., and 1No Indoor Hi wall mounted 1.5 TR capacity evaporator unit complete with cooling coil, blower motor and connected accessories, control etc, with 3 metre copper refrigerant piping and chord wire connecting indoor and out door unit with drain pipe suitable for operation on 230V+ 10% 50 HZ single phase AC supply.(Make: Carrier/Equ) |
| 30 | Supply and fixing of 5 KVA Automatic voltage stabilizer with time delay arrangements for operation on 230V 50C/S AC supply (Make V-Guard/Equ) |
| 31 | 'Supply and laying of 5/8\\" and 3/8\\" copper pipe (Extra beyond 3 metres supplied with AC unit) |
| 32 | Supply and fixing of out door base stand for split AC unit |
| 33 | Supply and fixing of water drain pipe line (1 inch PVC Pipe) |
| 34 | Supply and Run of 2 of 4 sq.mm. (56/0.3) PVC insulated SC unsheathed copper conductor of 1100 grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour. |
| 35 | Supply and fixing of 20 Amp DP Plug and socket in sheet enclosure with 32A DP MCB in flush with wall with earth connection (For A.C Plug) SD 140 |
| 36 | Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with Module Plastic surface mounting switch box on wall with 6A one way module switch with module front plate with painting of Suitable colour for Open PVC Light point / fan point (for electronic regulator) ( 5 points / Coil) Lower End (SD 306) |
| 37 | Supply and fixing of 1 no.6A two module socket, 1 no. 6/16A two module socket, 1 no. 6A one module switch, 1 no. 16A one module switch on suitable module surface mounting Box (Plastic) with module cover plate (plastic) on wall with connections. Higher End (SD-422) |
| 38 | Supply and fixing of 7 segment 8 way 63A TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one No 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one No 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 6 ways in Each segment) and seperate provision for MCB / Isolators ( totally 24 Nos) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. with the following in flush with wall with Earth connection only. (SD 638) |
| 39 | Supply and Laying of 3 1/2 x 70 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. (SD 671) |
| 40 | Supply and providing cable end termination of 3-1/2 x 70 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete. (SD 226) |
| 41 | Supply and fixing of brass cable gland for 3-1/2 x 70 sq.mm. PVC armoured LTUG cable with earth connection. (SD 167) |
| 42 | Supply and fixing of 42W 2x2 fitting with LED on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. (Make: Havells/Philips/Equ) |
| 43 | Renewal by supply and fixing of 400mm Oscillating type wall mounting fan (Crompton /Havells /Orient/ Usha make helix high speed /Eq) on wall with connection complete |
| 44 | Supply, installation, testing, and commissioning of 24V DC, 10W–12W per metre Chip on Board (COB) LED Strip Light for false ceiling cove lighting, complete with suitable 24V LED driver/power supply, connectors, wiring, mounting accessories, and all necessary materials, including fixing and electrical connections, complete as per site requirements and to the satisfaction of the Engineer-in-Charge. |
| 45 | Supply, installation, testing, and commissioning of recessed LED Aluminium Profile Light for wall panelling, with an overall profile width not exceeding 20 mm and suitable recessed depth, complete with 24V DC, 10W–12W per metre profile light, opal diffuser cover, suitable LED driver/power supply, connectors, wiring, end caps, mounting accessories, and all necessary materials, including cutting, fixing, and electrical connections, complete as per approved drawings and site requirements, to the satisfaction of the Engineer-in-Charge. |
| 46 | Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry |
| 47 | Design, supply, installation, testing and commissioning of a complete Heating, Ventilation and Air Conditioning (HVAC) system for an area of approximately 950 Sq.ft, including assessment of cooling load and selection of suitable air-conditioning equipment based on the area, occupancy, heat load and functional requirements. The scope shall include supply and installation of suitable air-conditioning units, indoor and outdoor units, refrigerant copper piping with insulation, condensate drain piping, refrigerant charging, necessary electrical wiring and control arrangements, air distribution ductwork (where applicable), supply and return air grilles, diffusers, supports, hangers and all associated accessories. The work shall also include provision of necessary ventilation and fresh air arrangements, proper routing of services, insulation, sealing, coordination with false ceiling and other building services, and all required civil and electrical interface works. The complete system shall be installed with proper alignment, leak testing, insulation checks, air balancing, testing and commissioning to ensure efficient cooling, adequate air circulation, uniform temperature distribution, energy-efficient operation and a comfortable indoor environment. The rate shall include all materials, labour, transportation, tools, equipment, installation accessories and incidental works required to deliver a fully functional HVAC system. |
| 48 | Supply, installation, testing, and commissioning of one 8-channel Network Video Recorder (NVR) with four (4 Nos.) 4MP IP cameras, including 2TB surveillance hard disk, all necessary accessories, cabling, connectors, and other required materials for complete and functional CCTV surveillance system. |
| 49 | Supply, installation, testing and commissioning of Micro Processor based conventional 8 Zone Fire Alarm Control Panel having the rating of 24 volt DC power supply, consisting 230 / 24 volt SMPS unit, 2 Nos. of 12 volt 7 AH standby batteries, suitably mounted on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers. |
| 50 | Supply, installation, testing and commissioning of Conventional Smoke Detector suitably mounted on ceiling with MS juction box / false ceiling using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers. (Make: Apollo / Equivalent) |
| 51 | Supply, installation, testing and commissioning of Manual Call Point (MCP) providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers. (Make: Ravel / Equivalent) |
| 52 | Supply, installation, testing and commissioning of Electronic Hooter / Sounder providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers (Make: Ravel/ Equivalent) |
| 53 | Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers. |
| 54 | Supply, installation, testing, and commissioning of premium-quality Last Man Out (LMO) Safety Switch for Tomotherapy Bunker, comprising industrial-grade illuminated push-button switch with dual contact arrangement, 24V DC or OEM-specified operating voltage, heavy-duty SS/metal enclosure with minimum IP65 protection, LED status indication, suitable mounting arrangements, industrial-grade control cables, conduits, connectors, terminal blocks, cable glands, and all necessary accessories, including interface integration with the RT equipment safety interlock system, functional testing and commissioning, complete as per approved drawings, OEM specifications and radiation safety requirements, to the satisfaction of the Engineer-in-Charge. |
| 55 | Supply, installation, testing, and commissioning of premium-quality LED-based Radiation Warning Indicator Light for Tomotherapy entrance Lead Door, comprising industrial-grade high-visibility Red and Green LED indicators, 24V DC or OEM-specified operating voltage, heavy-duty metal/industrial-grade enclosure, long-life LED modules, suitable mounting arrangements, necessary control cables, wiring, conduits, connectors, power supply, and OEM-compatible interface connections with the Radiotherapy Equipment Safety Interlock System, including complete integration, functional testing, and commissioning, as per approved drawings, OEM specifications, and radiation safety requirements, complete in all respects to the satisfaction of the Engineer-in-Charge. |
| 56 | Supply, installation, testing, and commissioning of a Two-Way Patient Intercom System comprising one (1 No.) hands-free master station, patient station with two (2 Nos.) microphones, one (1 No.) amplifier, and two (2 Nos.) wall-mounted speakers, including all necessary accessories, cabling, connectors, and installation materials required for a complete and functional intercom system. |
| 57 | Supply, installation, testing and commissioning of 1 KVA double-conversion online UPS system with 3 Nos. of 42 AH batteries, providing approximately 30 minutes of backup based on the connected load. The scope includes battery rack, interconnecting cables, input/output wiring, electrical connections, protection devices and necessary accessories. |
| 58 | Supply, laying, routing and installation of CAT 6 UTP data cables for providing network connectivity points at designated locations as per approved layout. The scope includes cable routing through concealed conduits, cable trays or suitable pathways, termination at I/O boxes and network patch panels using appropriate RJ45 connectors and information outlets. The work shall include necessary accessories, labelling, dressing, crimping, testing and certification of each data point to ensure proper connectivity and network performance. |
| 59 | Collecting the scattered debris from the campus and conveying away the same to outside by lorry to a lead of 3KM including loading and unloading charges and dumping in low places and leveling etc., complete. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysDec 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender