Petroleum and Natural Gas Boards / Undertakings / PSU Closing in 9 days TDR #58617334

Bids Are invited for Customized Amc/Cmc For Pre-Owned Products - 9030C26e51 Comprehensive Maintenance Of Ms Bluestar Make Air Conditioning System At Iocl Dumad Complex; As Per Ssc-T; Comprehensive Maintenance Contract (Cmc); As Per Ssc-T; No - Rfq Li

Issued by Boards / Undertakings / PSU · Vadodara, Gujarat
Tender Value
Ref. Documents
Estimated cost
Bid Submission
30 Nov 2026
9 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Vadodara → Gujarat
EMD Exemption
Not Available
Quantity
1

Project Description

Bids Are invited for Customized Amc/Cmc For Pre-Owned Products - 9030C26e51 Comprehensive Maintenance Of Ms Bluestar Make Air Conditioning System At Iocl Dumad Complex; As Per Ssc-T; Comprehensive Maintenance Contract (Cmc); As Per Ssc-T; No - Rfq Line Item-10:Comprehensive Maint Of Bluestar Ac , Rfq Line Item-10:Comprehensive Maintenance Of M/S Bluestar Make Vrf Type Ac Plants Installed At Different Locations Of Iocl Dumad Complex Inlcuding Supply Of Manpower, Materials I.E. Spares(Subject To Standard Exclusions) & Consumables, Tools & Tackles, Etc. Required For Successful Execution Of The Job Complete In All Aspects. , Sor Item-20: Comprehensive Maintenance Of (3 X 24Hp) Vrf Type Ac Installed For Adminbuilding Ground Floor & First Floor, With Following Configuration: Outdoor Units:Capacity - 24 Hp, Qty - 3 Nos. Indoor Units:A) Ductable Split Ac:Capacity - 2.5 Tr, Qty - 3 Noscapacity - 4.0 Tr, Qty - 4 Noscapacity - 5.0 Tr, Qty - 2 Nosb) 4-Way Cassette Ac:Capacity - 2.8 Tr, Qty - 2 Noscapacity - 2.0 Tr, Qty - 2 Nos , Sor Item-30: Comprehensive Maintenance Of (4 X 18Hp) Vrf Type Ac Installed For Adminbuilding Ground Floor, With Following Configuration: Outdoor Units: Capacity - 18Hp, Qty - 4 Nos. Air Handling Unit (Ahu): Capacity - 10500 Cfm, Qty - 2 Nos. Chemical Media Filter : Qty - 1 Nos. , Sor Item-40: Comprehensive Maintenance Of (4 X 24Hp) Vrf Type Ac Installed For Adminbuilding First Floor, With Following Configuration: Outdoor Units: Capacity - 24Hp, Qty - 4 Nos. Air Handling Unit (Ahu):Capacity - 13750 Cfm, Qty - 2 Nos. Chemical Media Filter : Qty , Sor Item-50: Comprehensive Maintenance Of (3 X 26Hp) Vrf Type Ac Installed For Security Building, With Following Configuration:Outdoor Units:Capacity - 26 Hp, Qty - 3 Nos.Indoor Units:A) Ductable Split Ac:Capacity - 3.0 Tr, Qty - 1 Noscapacity - 8.0 Tr, Qty - 3 Nosb) 4-Way Cassette Ac:Capacity - 1.7 Tr, Qty - 1 Noscapacity - 2.3 Tr, Qty - 1 Noscapacity - 2.8 Tr, Qty - 3 Noscapacity - 3.2 Tr, Qty - 1 Noscapacity - 4.0 Tr, Qty - 1 Nosb) 4-Way Compact Cassette Ac:Capacity - 1.0 Tr, Qty - 4 Noscapacity - 1.3 Tr, Qty - 2 Noscapacity - 1.5 Tr, Qty - 2 Nostreated Fresh Air Units:Capacity - 5.5 Tr, Qty - 2 Nos. , Sor Item-60: Comprehensive Maintenance Of (3 X 14Hp) Vrf Type Ac Installed Forfire & Safety Facility, With Followingconfiguration:Outdoor Units:Capacity - 14 Hp, Qty - 3 Nos.Indoor Units:A) Ductable Split Ac:Capacity - 3.0 Tr, Qty - 2 Nosb) 4-Way Cassette Ac:Capacity - 2.3 Tr, Qty - 1 Noscapacity - 2.8 Tr, Qty - 2 Noscapacity - 3.2 Tr, Qty - 5 Nostreated Fresh Air Units:Capacity - 3.5 Tr, Qty - 1 Nos. , Sor Item-70: Comprehensive Maintenance Of (2 X 14Hp) Vrf Type Ac Installed Forworkshop, With Following Configuration:Outdoor Units:Capacity - 14 Hp, Qty - 2 Nos. Indoor Units (4-Way Cassette Ac):Capacity - 1.7 Tr, Qty - 6 Noscapacity - 2.3 Tr, Qty - 1 Nostreated Fresh Air Units:Capacity - 3.5 Tr, Qty - 1 Nos. , Sor Item-80: Comprehensive Maintenance Of (2 X 22Hp) Vrf Type Ac Installed Forwarehouse, With Following Configuration:Outdoor Units:Capacity - 22 Hp, Qty - 2 Nos.Indoor Units (4-Way Cassette Ac):Capacity - 1.5 Tr, Qty - 1 Noscapacity - 2.8 Tr, Qty - 5 Noscapacity - 3.2 Tr, Qty - 1 Nostreated Fresh Air Units:Capacity - 3.5 Tr, Qty - 1 Nos. , Sor Item-90: Comprehensive Maintenance Of M/S Bluestar Make (3 X 5.5Tr) Pacakge Acinstalled At Mounted Bullet Srr, Including Supply Of Manpower, Material (I.E. Spares & Consumables), Tools & Tackles, Etc. Required For Successful Execution Of The Job Complete In All Aspects. , Sor Item-100: Comprehensive Maintenance Of 3 X 24 Hp Vrf Type Air Conditioners Ahusystem Installed For The Qc Lab, With The Following Configuration With Air Balancing:Outdoor Units: Capacity # 24 Hp, Quantity # 3 Nos. Air Handling Unit (Ahu): Capacity #21400 Cfm, Qty - 1 Nos. , Sor Item-110: Comprehensive Maintenance Of 1 X 10 Hp Vrf Type Air Conditioners Cassette Idu Installed In The Qc Lab Offices, With The Following Configuration:Outdoor Units: Capacity # 10 Hp, Quantity # 1 Nos. Indoor Units: 4-Way Cassette Ac: Capacity # 2 Tr, Quantity # 5 Nos. , Sor Item-120: Supply Of 02 (Two) Authorised Skilled Manpower Of M/S Bluestar Limitedfor Operation And Day-To-Day Upkeep Activities Of The Aforementioned Vrf Type Ac Systems Installed At Iocl Dumad Complex As Per Scct-Of The Contract And Directions Of Eic , Sor Item-130: Supply Of 02 (Two) Authorisedskilled Manpower Of M/S Bluestar Limitedfor Operation And Day-To-Day Upkeep Activities Of The Aforementioned Vrf Type Ac Systems Installed At Iocl Dumad Complex As Per Scct-Of The Contract And Directions Of Eic

BOQ

Sl. No. Item TitleItem Description
1RFQ Line item-10:Comprehensive Maint of Bluestar ACRFQ Line item-10:Comprehensive Maint of Bluestar AC
2RFQ Line item-10:Comprehensive Maintenance of M/s Bluestar make VRF type AC plants installed at different locations of IOCL Dumad Complex inlcuding supply of manpower, materials i.e. spares(subject to standard exclusions) & consumables, tools & tackles, etc. required for successful execution of the job complete in all aspects.RFQ Line item-10:Comprehensive Maintenance of M/s Bluestar make VRF type AC plants installed at different locations of IOCL Dumad Complex inlcuding supply of manpower, materials i.e. spares(subject to standard exclusions) & consumables, tools & tackles, etc. required for successful execution of the job complete in all aspects.
3SOR Item-20: Comprehensive Maintenance of (3 X 24HP) VRF TYPE AC installed for Adminbuilding ground floor & first floor, with following configuration: Outdoor units:Capacity - 24 HP, Qty - 3 Nos. Indoor Units:a) Ductable split AC:Capacity - 2.5 TR, Qty - 3 NosCapacity - 4.0 TR, Qty - 4 NosCapacity - 5.0 TR, Qty - 2 Nosb) 4-way cassette AC:Capacity - 2.8 TR, Qty - 2 NosCapacity - 2.0 TR, Qty - 2 NosSOR Item-20: Comprehensive Maintenance of (3 X 24HP) VRF TYPE AC installed for Adminbuilding ground floor & first floor, with following configuration: Outdoor units:Capacity - 24 HP, Qty - 3 Nos. Indoor Units:a) Ductable split AC:Capacity - 2.5 TR, Qty - 3 NosCapacity - 4.0 TR, Qty - 4 NosCapacity - 5.0 TR, Qty - 2 Nosb) 4-way cassette AC:Capacity - 2.8 TR, Qty - 2 NosCapacity - 2.0 TR, Qty - 2 Nos
4SOR Item-30: Comprehensive Maintenance of (4 X 18HP) VRF TYPE AC installed for Adminbuilding ground floor, with following configuration: Outdoor units: Capacity - 18HP, Qty - 4 Nos. Air Handling Unit (AHU): Capacity - 10500 CFM, Qty - 2 Nos. Chemical Media filter : Qty - 1 Nos.SOR Item-30: Comprehensive Maintenance of (4 X 18HP) VRF TYPE AC installed for Adminbuilding ground floor, with following configuration: Outdoor units: Capacity - 18HP, Qty - 4 Nos. Air Handling Unit (AHU): Capacity - 10500 CFM, Qty - 2 Nos. Chemical Media filter : Qty - 1 Nos.
5SOR Item-40: Comprehensive Maintenance of (4 X 24HP) VRF TYPE AC installed for Adminbuilding first floor, with following configuration: Outdoor units: Capacity - 24HP, Qty - 4 Nos. Air Handling Unit (AHU):Capacity - 13750 CFM, Qty - 2 Nos. Chemical Media filter : QtySOR Item-40: Comprehensive Maintenance of (4 X 24HP) VRF TYPE AC installed for Adminbuilding first floor, with following configuration: Outdoor units: Capacity - 24HP, Qty - 4 Nos. Air Handling Unit (AHU):Capacity - 13750 CFM, Qty - 2 Nos. Chemical Media filter : Qty
6SOR Item-50: Comprehensive Maintenance of (3 X 26HP) VRF TYPE AC installed for Security building, with following configuration:Outdoor units:Capacity - 26 HP, Qty - 3 Nos.Indoor Units:a) Ductable split AC:Capacity - 3.0 TR, Qty - 1 NosCapacity - 8.0 TR, Qty - 3 Nosb) 4-way cassette AC:Capacity - 1.7 TR, Qty - 1 NosCapacity - 2.3 TR, Qty - 1 NosCapacity - 2.8 TR, Qty - 3 NosCapacity - 3.2 TR, Qty - 1 NosCapacity - 4.0 TR, Qty - 1 Nosb) 4-way compact cassette AC:Capacity - 1.0 TR, Qty - 4 NosCapacity - 1.3 TR, Qty - 2 NosCapacity - 1.5 TR, Qty - 2 NosTreated fresh air units:Capacity - 5.5 TR, Qty - 2 Nos.SOR Item-50: Comprehensive Maintenance of (3 X 26HP) VRF TYPE AC installed for Security building, with following configuration:Outdoor units:Capacity - 26 HP, Qty - 3 Nos.Indoor Units:a) Ductable split AC:Capacity - 3.0 TR, Qty - 1 NosCapacity - 8.0 TR, Qty - 3 Nosb) 4-way cassette AC:Capacity - 1.7 TR, Qty - 1 NosCapacity - 2.3 TR, Qty - 1 NosCapacity - 2.8 TR, Qty - 3 NosCapacity - 3.2 TR, Qty - 1 NosCapacity - 4.0 TR, Qty - 1 Nosb) 4-way compact cassette AC:Capacity - 1.0 TR, Qty - 4 NosCapacity - 1.3 TR, Qty - 2 NosCapacity - 1.5 TR, Qty - 2 NosTreated fresh air units:Capacity - 5.5 TR, Qty - 2 Nos.
7SOR Item-60: Comprehensive Maintenance of (3 X 14HP) VRF TYPE AC installed forFire & safety facility, with followingconfiguration:Outdoor units:Capacity - 14 HP, Qty - 3 Nos.Indoor Units:a) Ductable split AC:Capacity - 3.0 TR, Qty - 2 Nosb) 4-way cassette AC:Capacity - 2.3 TR, Qty - 1 NosCapacity - 2.8 TR, Qty - 2 NosCapacity - 3.2 TR, Qty - 5 NosTreated fresh air units:Capacity - 3.5 TR, Qty - 1 Nos.SOR Item-60: Comprehensive Maintenance of (3 X 14HP) VRF TYPE AC installed forFire & safety facility, with followingconfiguration:Outdoor units:Capacity - 14 HP, Qty - 3 Nos.Indoor Units:a) Ductable split AC:Capacity - 3.0 TR, Qty - 2 Nosb) 4-way cassette AC:Capacity - 2.3 TR, Qty - 1 NosCapacity - 2.8 TR, Qty - 2 NosCapacity - 3.2 TR, Qty - 5 NosTreated fresh air units:Capacity - 3.5 TR, Qty - 1 Nos.
8SOR Item-70: Comprehensive Maintenance of (2 X 14HP) VRF TYPE AC installed forWorkshop, with following configuration:Outdoor units:Capacity - 14 HP, Qty - 2 Nos. Indoor Units (4-way cassette AC):Capacity - 1.7 TR, Qty - 6 NosCapacity - 2.3 TR, Qty - 1 NosTreated fresh air units:Capacity - 3.5 TR, Qty - 1 Nos.SOR Item-70: Comprehensive Maintenance of (2 X 14HP) VRF TYPE AC installed forWorkshop, with following configuration:Outdoor units:Capacity - 14 HP, Qty - 2 Nos. Indoor Units (4-way cassette AC):Capacity - 1.7 TR, Qty - 6 NosCapacity - 2.3 TR, Qty - 1 NosTreated fresh air units:Capacity - 3.5 TR, Qty - 1 Nos.
9SOR Item-80: Comprehensive Maintenance of (2 X 22HP) VRF TYPE AC installed forWarehouse, with following configuration:Outdoor units:Capacity - 22 HP, Qty - 2 Nos.Indoor Units (4-way cassette AC):Capacity - 1.5 TR, Qty - 1 NosCapacity - 2.8 TR, Qty - 5 NosCapacity - 3.2 TR, Qty - 1 NosTreated fresh air units:Capacity - 3.5 TR, Qty - 1 Nos.SOR Item-80: Comprehensive Maintenance of (2 X 22HP) VRF TYPE AC installed forWarehouse, with following configuration:Outdoor units:Capacity - 22 HP, Qty - 2 Nos.Indoor Units (4-way cassette AC):Capacity - 1.5 TR, Qty - 1 NosCapacity - 2.8 TR, Qty - 5 NosCapacity - 3.2 TR, Qty - 1 NosTreated fresh air units:Capacity - 3.5 TR, Qty - 1 Nos.
10SOR Item-90: Comprehensive Maintenance of M/s Bluestar make (3 X 5.5TR) Pacakge ACinstalled at mounted bullet SRR, including supply of manpower, material (i.e. spares & consumables), tools & tackles, etc. required for successful execution of the job complete in all aspects.SOR Item-90: Comprehensive Maintenance of M/s Bluestar make (3 X 5.5TR) Pacakge ACinstalled at mounted bullet SRR, including supply of manpower, material (i.e. spares & consumables), tools & tackles, etc. required for successful execution of the job complete in all aspects.
11SOR Item-100: Comprehensive Maintenance of 3 X 24 HP VRF type air conditioners AHUsystem installed for the QC lab, with the following configuration with air balancing:Outdoor Units: Capacity # 24 HP, Quantity # 3 Nos. Air Handling Unit (AHU): Capacity #21400 CFM, Qty - 1 Nos.SOR Item-100: Comprehensive Maintenance of 3 X 24 HP VRF type air conditioners AHUsystem installed for the QC lab, with the following configuration with air balancing:Outdoor Units: Capacity # 24 HP, Quantity # 3 Nos. Air Handling Unit (AHU): Capacity #21400 CFM, Qty - 1 Nos.
12SOR Item-110: Comprehensive Maintenance of 1 X 10 HP VRF type air conditioners cassette IDU installed in the QC lab offices, with the following configuration:Outdoor Units: Capacity # 10 HP, Quantity # 1 Nos. Indoor Units: 4-Way Cassette AC: Capacity # 2 TR, Quantity # 5 Nos.SOR Item-110: Comprehensive Maintenance of 1 X 10 HP VRF type air conditioners cassette IDU installed in the QC lab offices, with the following configuration:Outdoor Units: Capacity # 10 HP, Quantity # 1 Nos. Indoor Units: 4-Way Cassette AC: Capacity # 2 TR, Quantity # 5 Nos.
13SOR Item-120: Supply of 02 (two) authorised skilled manpower of M/s Bluestar limitedfor operation and day-to-day upkeep activities of the aforementioned VRF type AC systems installed at IOCL Dumad complex as per SCCT-of the contract and directions of EICSOR Item-120: Supply of 02 (two) authorised skilled manpower of M/s Bluestar limitedfor operation and day-to-day upkeep activities of the aforementioned VRF type AC systems installed at IOCL Dumad complex as per SCCT-of the contract and directions of EIC
14SOR Item-130: Supply of 02 (two) authorisedskilled manpower of M/s Bluestar limitedfor operation and day-to-day upkeep activities of the aforementioned VRF type AC systems installed at IOCL Dumad complex as per SCCT-of the contract and directions of EICSOR Item-130: Supply of 02 (two) authorisedskilled manpower of M/s Bluestar limitedfor operation and day-to-day upkeep activities of the aforementioned VRF type AC systems installed at IOCL Dumad complex as per SCCT-of the contract and directions of EIC

AI Tender Summary

OUR REF NO 58617334
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 30-11-2026
Authority
Authority Name Indian Oil Corporation Limited
Work Description Bids Are invited for Customized Amc/Cmc For Pre-Owned Products - 9030C26e51 Comprehensive Maintenance Of Ms Bluestar Make Air Conditioning System At Iocl Dumad Complex; As Per Ssc-T; Comprehensive Maintenance Contract (Cmc); As Per Ssc-T; No - Rfq Line Item-10:Comprehensive Maint Of Bluestar Ac , Rfq Line Item-10:Comprehensive Maintenance Of M/S Bluestar Make Vrf Type Ac Plants Installed At Different Locations Of Iocl Dumad Complex Inlcuding Supply Of Manpower, Materials I.E. Spares(Subject To Standard Exclusions) & Consumables, Tools & Tackles, Etc. Required For Successful Execution Of The Job Complete In All Aspects. , Sor Item-20: Comprehensive Maintenance Of (3 X 24Hp) Vrf Type Ac Installed For Adminbuilding Ground Floor & First Floor, With Following Configuration: Outdoor Units:Capacity - 24 Hp, Qty - 3 Nos. Indoor Units:A) Ductable Split Ac:Capacity - 2.5 Tr, Qty - 3 Noscapacity - 4.0 Tr, Qty - 4 Noscapacity - 5.0 Tr, Qty - 2 Nosb) 4-Way Cassette Ac:Capacity - 2.8 Tr, Qty - 2 Noscapacity - 2.0 Tr, Qty - 2 Nos , Sor Item-30: Comprehensive Maintenance Of (4 X 18Hp) Vrf Type Ac Installed For Adminbuilding Ground Floor, With Following Configuration: Outdoor Units: Capacity - 18Hp, Qty - 4 Nos. Air Handling Unit (Ahu): Capacity - 10500 Cfm, Qty - 2 Nos. Chemical Media Filter : Qty - 1 Nos. , Sor Item-40: Comprehensive Maintenance Of (4 X 24Hp) Vrf Type Ac Installed For Adminbuilding First Floor, With Following Configuration: Outdoor Units: Capacity - 24Hp, Qty - 4 Nos. Air Handling Unit (Ahu):Capacity - 13750 Cfm, Qty - 2 Nos. Chemical Media Filter : Qty , Sor Item-50: Comprehensive Maintenance Of (3 X 26Hp) Vrf Type Ac Installed For Security Building, With Following Configuration:Outdoor Units:Capacity - 26 Hp, Qty - 3 Nos.Indoor Units:A) Ductable Split Ac:Capacity - 3.0 Tr, Qty - 1 Noscapacity - 8.0 Tr, Qty - 3 Nosb) 4-Way Cassette Ac:Capacity - 1.7 Tr, Qty - 1 Noscapacity - 2.3 Tr, Qty - 1 Noscapacity - 2.8 Tr, Qty - 3 Noscapacity - 3.2 Tr, Qty - 1 Noscapacity - 4.0 Tr, Qty - 1 Nosb) 4-Way Compact Cassette Ac:Capacity - 1.0 Tr, Qty - 4 Noscapacity - 1.3 Tr, Qty - 2 Noscapacity - 1.5 Tr, Qty - 2 Nostreated Fresh Air Units:Capacity - 5.5 Tr, Qty - 2 Nos. , Sor Item-60: Comprehensive Maintenance Of (3 X 14Hp) Vrf Type Ac Installed Forfire & Safety Facility, With Followingconfiguration:Outdoor Units:Capacity - 14 Hp, Qty - 3 Nos.Indoor Units:A) Ductable Split Ac:Capacity - 3.0 Tr, Qty - 2 Nosb) 4-Way Cassette Ac:Capacity - 2.3 Tr, Qty - 1 Noscapacity - 2.8 Tr, Qty - 2 Noscapacity - 3.2 Tr, Qty - 5 Nostreated Fresh Air Units:Capacity - 3.5 Tr, Qty - 1 Nos. , Sor Item-70: Comprehensive Maintenance Of (2 X 14Hp) Vrf Type Ac Installed Forworkshop, With Following Configuration:Outdoor Units:Capacity - 14 Hp, Qty - 2 Nos. Indoor Units (4-Way Cassette Ac):Capacity - 1.7 Tr, Qty - 6 Noscapacity - 2.3 Tr, Qty - 1 Nostreated Fresh Air Units:Capacity - 3.5 Tr, Qty - 1 Nos. , Sor Item-80: Comprehensive Maintenance Of (2 X 22Hp) Vrf Type Ac Installed Forwarehouse, With Following Configuration:Outdoor Units:Capacity - 22 Hp, Qty - 2 Nos.Indoor Units (4-Way Cassette Ac):Capacity - 1.5 Tr, Qty - 1 Noscapacity - 2.8 Tr, Qty - 5 Noscapacity - 3.2 Tr, Qty - 1 Nostreated Fresh Air Units:Capacity - 3.5 Tr, Qty - 1 Nos. , Sor Item-90: Comprehensive Maintenance Of M/S Bluestar Make (3 X 5.5Tr) Pacakge Acinstalled At Mounted Bullet Srr, Including Supply Of Manpower, Material (I.E. Spares & Consumables), Tools & Tackles, Etc. Required For Successful Execution Of The Job Complete In All Aspects. , Sor Item-100: Comprehensive Maintenance Of 3 X 24 Hp Vrf Type Air Conditioners Ahusystem Installed For The Qc Lab, With The Following Configuration With Air Balancing:Outdoor Units: Capacity # 24 Hp, Quantity # 3 Nos. Air Handling Unit (Ahu): Capacity #21400 Cfm, Qty - 1 Nos. , Sor Item-110: Comprehensive Maintenance Of 1 X 10 Hp Vrf Type Air Conditioners Cassette Idu Installed In The Qc Lab Offices, With The Following Configuration:Outdoor Units: Capacity # 10 Hp, Quantity # 1 Nos. Indoor Units: 4-Way Cassette Ac: Capacity # 2 Tr, Quantity # 5 Nos. , Sor Item-120: Supply Of 02 (Two) Authorised Skilled Manpower Of M/S Bluestar Limitedfor Operation And Day-To-Day Upkeep Activities Of The Aforementioned Vrf Type Ac Systems Installed At Iocl Dumad Complex As Per Scct-Of The Contract And Directions Of Eic , Sor Item-130: Supply Of 02 (Two) Authorisedskilled Manpower Of M/S Bluestar Limitedfor Operation And Day-To-Day Upkeep Activities Of The Aforementioned Vrf Type Ac Systems Installed At Iocl Dumad Complex As Per Scct-Of The Contract And Directions Of Eic
Basic Detail
Tender No GEM/2026/B/8295037
Bidding Type Tender
Location
City Vadodara
State Gujarat
Key Dates
Publish Date 19 Nov 2026
Submission Date 30 Nov 2026
Open Date 01 Dec 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
6a855736-af06-4858-a135-e918c6bfcbad.pdf
1795084851.xlsx
1795084860.pdf
1795084864.pdf
1795084869.pdf
1795084874.pdf
1795084882.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Dec 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
pdf

6a855736-af06-4858-a135-e918c6bfcbad.pdf

xlsx

1795084851.xlsx

pdf

1795084860.pdf

pdf

1795084864.pdf

pdf

1795084869.pdf

pdf

1795084874.pdf

pdf

1795084882.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender