Tender For Augmentations Of Substations (Sasci)
Tender Value
49 Lakhs
Estimated cost
Bid Submission
07 Dec 2026
16 days left
EMD
98000
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Anantnag → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Augmentations Of Substations (Sasci)
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-Nov-2026 | Corrigendum | Other | 07-Dec-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Augmentations of Substations (SASCI) |
| 2 | Supply,loading, unloading at site ,Carriage, Installation, testing & commisioing of 100kva 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-1 (corresponding to previous Energy efficiency level II) as per IS 1180 (part I of 2014), (Al. wound upto 200kVA, Cu wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Al. Gland plate with LV Bimetallic terminal connection suitable for vertical take off of cable.( X-mer without OCTC (Off Ckt Tap Changer)) |
| 3 | Supply,loading, unloading at site ,Carriage, Installation, testing & commisioing of 200kva 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-1 (corresponding to previous Energy efficiency level II) as per IS 1180 (part I of 2014), (Al. wound upto 200kVA, Cu wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Al. Gland plate with LV Bimetallic terminal connection suitable for vertical take off of cable.( X-mer without OCTC (Off Ckt Tap Changer)) |
| 4 | Providing and fixing of SL Clamps off sizes |
| 5 | Loading and Carriage of 63 KVA spare DT out of Augmentation back to Divisional stores at Bijbehara complete job |
| 6 | Loading and Carriage of 100 KVA spare DT out of Augmentation back to Divisional stores at Bijbehara complete job |
| 7 | Supply,loading, unloading at site Erection, testing & commissioning of S.T Pole 9mtr Long SP-33 with base plate & cap for HT. Strictly as per REC standards |
| 8 | Supply,loading, unloading at site Erection, testing & commissioning of S.T Pole 8mtr Long SP-15 with base plate & cap for LT. Strictly as per REC standards |
| 9 | Supply and fixing of 120 mm² Single-Core Cable, 1.1kV Grade, XLPE un armoured FRLS type |
| 10 | Supply and fixing of 240 mm² Single-Core Cable, 1.1kV Grade, XLPE un armoured FRLS type |
| 11 | Supply,fixing, testing & commissioning of 11KV LA Set Gap less as per IS Standards |
| 12 | Supply,fixing, testing & commissioning of 11KV GO Set, AB Switch as per IS Standards |
| 13 | Supply,fixing, testing & commissioning of 11KV DO Fuse Set as per IS Standards |
| 14 | Supply/Fixing & commissioning of GI Channel/Angle/Flat of Sizes including clamps |
| 15 | LT Distribution Box for 100 kVA DTR:- 2mm thick CRCA (1000x325x1010)mm with 1 no.adjustable 160 Amp MCCB 3P 16 kA for incomer & 2 no. fixed 100 Amp MCCB 3P 16 kA for Outgoing Circuits, 04 no.Al. Bus Bar (25x8)mm for phase/neutral,earthing bolt (M10x35) 2 set & 6 no. link disconector 200 Amp |
| 16 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 17 | Providing and Fixing of GI Nuts and Bolts. |
| 18 | Supplying and fixing of Coil Earthing having 115 turns of Dia 50 mm |
| 19 | Painting of poles with one coat of red oxide and two coats of Aluminium paint as per Standards. This also includes numbering of ploes with paint, submission of Pre and Post Execution photographs duly anthenticated by AEE concrened. |
| 20 | Cement bottoming 1:2:4 mix as per REC Standards 0.40cum/pole |
| 21 | Cement bottoming 1:2:4 mix as per REC Standards 0.48cum/pole |
| 22 | Providing & fixing of 11 kV polymeric composite disc insulator 12 kV , min failing load 45 kN, lighting impulse 75 kV positive and 80 kV negative, creepage distance 320mm |
| 23 | Supply,fixing, testing & commissioning of 11KV Pin Polymer Insulators with GI pins complete. |
| 24 | Providing & fixing Wedge Connectors / PG Clamps |
| 25 | Providing and fixing of GI Barbed Wire for Anti Climbing |
| 26 | Providing and fixing of Danger Plates with Clamps |
| 27 | Providing and fixing Earthing complete by GI Pipe 40mm or GI Rod 20mm 2.5mtr long through GI Strip |
| 28 | Providing and Fixing of Aluminum thimbles 300 mmsq Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 19, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Dec 07, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 16 daysDec 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender