Bids Are invited for Preventive Maintenance Of Substation And Generator At Te Bhadra
Tender Overview
Project Description
Bids Are invited for Servicing Of Existing 400Aht Panel - As Per Atc Item 1 , Sf Fresh Mineral Oil - As Per Atc Item 2 , Calibration Of Idmt Relays Of Ht Panel - As Per Atc Item 3 , Replacement Of Faulty Digital Ameter - As Per Atc Item 4 , Replacement Of Faulty Selector Switch - As Per Atc Item 5 , Replacement Of Faullty Ryb Indicating Lamp - As Per Atc Item 6 , Sf Of Control Fuse In Ht Panel - As Per Atc Item 7A , Filteration Of Mineral Oil - As Per Atc Item 8 , Servicing Cleaning Aluminium Bus Bar Trunking - As Per Atc Item 9 , Servicing Of Existing Main Mv Lt Panel With 1000 Acbs - As Per Atc Item 10 , Servicing Of Existing Main Mvlt Panel With 800 Acbs - As Per Atc Item 11 , Servicing Of Mv Lt Panel - As Per Atc Item 12 , Checking And Rectification Of Interlocking - As Per Atc Item 13 , Replacement Of Existing Faulty Digital Ameter Of Lt Sub Panel 1 And 2 Having Size 96 Mm By 96 Mm - As Per Atc Item 14 , Replacement Of Existing Faulty Digital Voltmeter Of Lt Sub Panel 1 And 2 Having Size 96 Mm By 96 Mm - As Per Atc Item 15 , Replacement Of Existing Faulty Ameter Voltmeter Selector Switch Of Lt Sub Panel 1And 2 - As Per Atc Item 16 , Replacement Of Existing Faulty Ryb Onoff Indication Lamp On Lt Panel - As Per Atc Item 17 , Calibration Of Idmt Relays Over Current , Earth Fault Of Lt Panel - As Per Atc Item 18 , Sf Of Control Fuse In Lt Panel - As Per Atc Item 19A , Supplying And Fixing 32 Fuse Link - As Per Atc Item 20A , Supplying And Fixing 63 Fuse Link , Supplying And Fixing 100 -125 Fuse Link , Supplying And Fixing 250 Fuse Link , Carry Out Service Of 01 No 500 Kva Dg Set , Servicing Of Extg. Dg Set Lt Panel Having 1250 4P Acb , Replacement Of Existing Faulty Ryb Onoff Indication Lamp On Dg Set Panel , Replacement Of Existing Faulty Digital Ameter Of Dg Panel , Providing Earthing Testing For Existing Earth Pits , Supplying Fixing Of The Smps Type Electronic Battery Charger , Supply Of Ms C Class Heavy Duty Pipe , Supply And Installation Of 12 V Lead Acid Battery 180Ah
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Servicing of existing 400AHT Panel | as per ATC Item 1 |
| 2 | SF Fresh Mineral Oil | as per ATC Item 2 |
| 3 | Calibration of IDMT Relays of HT Panel | as per ATC Item 3 |
| 4 | Replacement of faulty Digital Ameter | as per ATC Item 4 |
| 5 | Replacement of faulty selector switch | as per ATC Item 5 |
| 6 | Replacement of faullty RYB Indicating Lamp | as per ATC Item 6 |
| 7 | SF of Control Fuse in HT Panel | as per ATC Item 7a |
| 8 | Filteration of Mineral Oil | as per ATC Item 8 |
| 9 | Servicing cleaning Aluminium Bus Bar trunking | as per ATC Item 9 |
| 10 | Servicing of Existing Main MV LT Panel with 1000Amp ACBs | as per ATC Item 10 |
| 11 | Servicing of Existing Main MVLT Panel with 800Amp ACBs | as per ATC Item 11 |
| 12 | Servicing of MV LT Panel | as per ATC Item 12 |
| 13 | Checking and rectification of interlocking | as per ATC Item 13 |
| 14 | Replacement of existing faulty Digital Ameter of LT sub Panel 1 and 2 having size 96 mm by 96 mm | as per ATC Item 14 |
| 15 | Replacement of existing faulty Digital Voltmeter of LT sub Panel 1 and 2 having size 96 mm by 96 mm | as per ATC Item 15 |
| 16 | Replacement of existing faulty Ameter Voltmeter Selector switch of LT sub Panel 1and 2 | as per ATC Item 16 |
| 17 | Replacement of existing faulty RYB ONOFF indication lamp on LT Panel | as per ATC Item 17 |
| 18 | Calibration of IDMT relays over current , Earth fault of LT Panel | as per ATC Item 18 |
| 19 | SF of Control Fuse in LT Panel | as per ATC Item 19a |
| 20 | Supplying and fixing 32Amp Fuse link | as per ATC Item 20a |
| 21 | Supplying and fixing 63Amp Fuse link | as per ATC Item 20b |
| 22 | Supplying and fixing 100 -125Amp Fuse link | as per ATC Item 20c |
| 23 | Supplying and fixing 250Amp Fuse link | as per ATC Item 20d |
| 24 | Carry out service of 01 no 500 KVA DG set | as per ATC Item 21 |
| 25 | Servicing of Extg. DG set LT panel having 1250 Amp 4P ACB | as per ATC Item 22 |
| 26 | Replacement of existing faulty RYB ONOFF indication lamp on DG set Panel | as per ATC Item 23 |
| 27 | Replacement of existing faulty Digital Ameter of DG Panel | as per ATC Item 24 |
| 28 | Providing earthing Testing for existing earth pits | as per ATC Item 25 |
| 29 | Supplying fixing of the SMPS type electronic Battery Charger | as per ATC Item 26 |
| 30 | Supply of MS C class heavy duty pipe | as per ATC Item 27 |
| 31 | Supply and Installation of 12 V Lead acid Battery 180AH | as per ATC Item 28 |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender