Drinking Water Supply and Sanitation Government Departments Closing in 18 days TDR #58615878

Tender For Surveying, Soil Investigation, Engineering, Design, Supply Of All Materials, Labour, T&P Etc. Required For Completion Of Following Works Of Bakshi Ka Talab Nagar Panchayat Water Supply Scheme Distt. Lucknow Under Amrut 2.0 Programme On Tur

Issued by Government Departments · Lucknow, Uttar Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
08 Dec 2026
18 days left
EMD
99.65 Lakhs
Bank guarantee accepted
Document Fee
23600
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Surveying, Soil Investigation, Engineering, Design, Supply Of All Materials, Labour, T&P Etc. Required For Completion Of Following Works Of Bakshi Ka Talab Nagar Panchayat Water Supply Scheme Distt. Lucknow Under Amrut 2.0 Programme On Turn-Key Basis:Rcc Ohts, Rising Main, Distribution System Including House Connections, Scada Room, Chlorination Room, Meter Room, Panel Room, Boundary Wall & Site Development Works Etc. And Other Appurtenant Works Including Scada And Automation As Per Specifications In Tender Document. The Scope Of Work Also Includes Provisions & Specification As Specified In Tender Documents, Testing & Commissioning, Trial & Run For 3 Months, Defect Liability Period Of 12 Months For Civil Works & 24 Months For E/M Works After Completion Of Successful Trial Run. All Completed And Commissioned Work Under Bakshi Ka Talab Nagar Panchayat Water Supply Scheme Distt. Lucknow Under Amrut 2.0 Programme Shall Be Handed Over To Executive Officer, Nagar Panchayat Bakshi Ka Talab, Lucknow After 3 Months Of Successful Trial Run Period.

BOQ

Name of Work:- Surveying, Soil investigation, Engineering, Design, Supply of all materials, labour, T&P etc. required for completion of following works of Bakshi Ka Talab Nagar Panchayat Water Supply Scheme Distt. Lucknow under AMRUT 2.0 Programme on turn-key basis:RCC OHTs, Rising main, Distribution System including house connections, SCADA Room, Chlorination room, Meter Room, Panel Room, Boundary Wall & Site development works etc. and other appurtenant works including SCADA and Automation as per specifications in tender document. The scope of work also includes provisions & Specification as specified in tender documents, Testing & Commissioning, trial & run for 3 months, defect liability period of 12 months for Civil works & 24 months for E/M works after completion of successful trial run. All completed and commissioned work under Bakshi Ka Talab Nagar Panchayat Water Supply Scheme Distt. Lucknow under AMRUT 2.0 Programme shall be handed over to Executive Officer, Nagar Panchayat Bakshi Ka Talab, Lucknow after 3 months of successful trial run period.
Sl. No. Item Description
1A - Civil works :-Structural design and drawing must be vetted by any IIT (Indian Institute of Technology) of India, Supply of all materials, labour, T&P etc required for construction of Intz type RCC over head tank including various works like - Ventilator and Water level indicator, Lightening conductor, D.I. D/F Verticle pipes (Inlet Pipe, Outlet Pipe, Overflow Pipe & Washout Pipe), over flow pipe connect with distribution main with NRV of required dia with all necessary fittings such as sluice valve, NRV and their chamber as per design and specification and place decided by engineer in charge, duck foot bend, puddle collers and bell mouths, Sluice valve on inlet, outlet & washout pipe and sluice salve chamber, bye-pass arrangement of OHT, flooring, apran & drain (100 mm thick PCC of 1:1.5:3 & 100 mm thick RCC of 1:1:2 ), floor two coat apex weather coat (Asian, Berger etc.) painting over one coat primer of approved colour over wall putty two coat (Birla, JK, Asian, Berger etc.) after finishing of RCC surface with grinder, repair of pin holes, unevenness., railings - 20 mm G.I. pipe class - B railing around stair case (both sides), balcony & top dome periphery in three rows with MS angle iron post 50x50x6 in one metre distance, M.S ladder from opening of top dome to bottom dome 65x65x6 with 20 mm steel round bar, Stair case (Seperate two column based RCC staircase upto top dome and 1 m wide balcony with arrangement of M.S Gate and MS square mesh), Food grade epoxy coating of FOSROC / Ciba-Geigy or reputated brand on inside surface area of water container after testing for water tightness, of capacity and staging mentioned as under:For bidding purpose, bearing capacity of soil shall be considered as 8t/sq.m. Working design shall be based on the SBC determind after soil investigation / 8 tonne/sqm including required earthfilling for maintaining FGL as per level of nearest road cost of earth required for filling not to be paid extra.Note :- The bid price of over head tanks is to be submitted considering net safe allowable bearing capacity as 8 t/m2, keeping the minimum foundation depth to be 2.5 m below existing ground level at the site of work, layout as ground level of over head tank consider from 50 cm above than near of road surface to be finalized by the engineer in charge including, campus cleaning, removal of debries, bush cutting and disposal within municipal limt and filling ogf earth if required as per direction of Engineer in charge.The successful bidder will be required to investigate the soil bearing capacity. If net safe allowable bearing capacity is found to be equivalent or more than 8 t/m2, the design of OHT will be based on 8 t/m2 capacity. However, in case the net safe allowable bearing capacity is found to be below 8 t/m2, then the design of OHT will be based on the actual bearing capacity.
2Over Head Tank - 1100 KL / 24 M Staging at Zone I
3Over Head Tank - 1150 KL / 24 M Staging at Zone II
4Over Head Tank - 1300 KL / 22 M Staging at Zone III
5Over Head Tank - 750 KL / 22 M Staging at Zone IV
6Over Head Tank - 650 KL / 22 M Staging at Zone V
7Over Head Tank - 700 KL / 24 M Staging at Zone VI
8Over Head Tank - 850 KL / 24 M Staging at Zone VII
9Over Head Tank - 800 KL / 24 M Staging at Zone VIII
10Over Head Tank - 1100 KL / 24 M Staging at Zone IX
11Over Head Tank - 900 KL / 24 M Staging at Zone X
12Over Head Tank - 800 KL / 24 M Staging at Zone XI
13Dismantling of following type of road surface including sorting out and stacking of serviceable materials and disposal of unserviceable materials upto distance of 8km. and also including temporary reinstatement/motorable of road by old materials.
14B.O.E. road
15Bituminous road
16C.C. road
17Interlocking road
18Earthen road
19Earth work in excavation for pipeline trenches in all type of soil with including lift upto 1.5 m and lead upto 50M, refilling the soil as required, including depositing in layers not exceeding 150mm, watering and compaction to 95% of the Standard Proctor density, level dressing, including supply of all labour, T&P etc. required for proper completion of the work. Including disposal of surplus earth up to 8 Km as instucted by engineer in charge.
20Design of distribution network and supply of following dia of high density polyethelene Pipes (HDPE (PN-6)/PE-100), conforming to IS 4984 / 14151 / 12786 / 13488 in coils/ standard lengths with nesessary jointing material like electro-fusion coupler, flanged joint, including all statutary duties and taxes, third party inspection charges, transit insurance, freight, transportation to store/ site of work, unloading & stacking the same in covered shade duly protecting from sunrays & rains (keeping minimum dia of pipe 110 mm) including crossing of upto 1.00 m vide nala/drain etc. with Carting, lowering, laying and requisite specials to site of work, lowering them into trenches, laying true to alignment and gradient, in proper position, cutting of pipes, making of joints including cost of jointing materials and rubber rings, labour, T&P, including hydraulic testing etc. complete as directed by Engineer in-charge. It includes provision for making of alignment on city roads, making trial pits to investigate location of various under grounds services like telephone cables, gas pipe line, electric cable, existing pipe lines and sewer lines etc. arrangements for diversion of traffic and associated works etc. with supply of all necessary equipment, materials, labour and T&P etc. complete required for completion of work.The trenches shall be properly barricaded and fenced off wherever necessary. Red flags and caution boards during day and red lights during night shall be displayed so as to avoid any accidents. Note: Jointing between HDPE pipes and specials shall be done as per the latest IS: 7634 part II. Only Bar coded electro-fusion machine (automatically readable) that can read the bar code of the fittings automatically shall be used for jointing of HDPE pipe/fittings. Note: 1. Contractor will ensure to supply of 10 No. set of electrofusion jointing machine including cutting & peeling tool and other misc. equipments.2. Contractor will provide 04 No. set of hydro testing machine of 20 kg/cm² capacity including 02 Nos. tractor with water tanker will also be part of this set.3. Contractor will provide minimum 06 tractor trolley for disposal of surplus earth.4. Contractor will provide 04 No. of tractor with water tanker for sprinkling of water on trenches and 5 No. Anti Smoke Gun to protect the dust particals entering in the atmosphere which may be cause of increase of AQI of construction area.
2190 mm dia HDPE Pipe PN-6, PE 100
22110 mm dia HDPE Pipe PN-6, PE 100
23140 mm dia HDPE Pipe PN-6, PE 100
24160 mm dia HDPE Pipe PN-6, PE 100
25200 mm dia HDPE Pipe PN-6, PE 100
26Design of distribution network and supply of following dia of ISI marked S & S centrifugally cast (Spun) ductile iron pipes (Class K-7) as per IS : 8329-2000 suitable for push on jointing by compatible rubber gasket confirming to IS : 9523 : 1980 at store including all statutary duties and taxes, third party inspection charges, transit insurance, freight, transportation to store/ site of work, unloading, stacking, including crossing of upto 1.00 m vide nala/drain etc. Carting, lowering, laying and jointing with SBR ruber gaskets D.I. K-7 pipes of following dia & pressure including all specials, to site of work, lowering them into trenches, laying true to alignment and gradient, in proper position, cutting of pipes, making of joints including cost of jointing materials and rubber rings, labour, T&P, including hydraulic testing etc. complete as directed by Engineer in-charge. It includes provision for making of alignment on city roads, making trial pits to investigate location of various under grounds services like telephone cables, gas pipe line, electric cable, existing pipe lines and sewer lines etc. arrangements for diversion of traffic and associated works etc. with supply of all necessary equipment, materials, labour and T&P etc. complete required for completion of work. The trenches shall be properly barricaded and fenced off wherever necessary. Red flags and caution boards during day and red lights during night shall be displayed so as to avoid any accidents. Note : Only SBR Rubber gaskets to be used as per IS-5382 and IS- 12820.
27250 mm dia
28300 mm dia
29350 mm dia
30Risingmain :-Supply of following dia of ISI marked S & S Centrifugally Cast (Spun) Ductile Iron pipes (Class K-9) as per IS : 8329-2000 suitable for Push on jointing by compatible rubber gasket confirming to IS : 9523 : 1980 at store including all statutary duties and taxes, third party inspection charges, transit insurance, freight, transportation to store/ site of work, unloading, stacking, including crossing of upto 1.00 m vide nala/drain etc. Carting, lowering, laying and jointing with SBR ruber gaskets D.I. K-9 pipes of following dia & pressure including all specials, to site of work, lowering them into trenches, laying true to alignment and gradient, in proper position, cutting of pipes, making of joints including cost of jointing materials and rubber rings, labour, T&P, including hydraulic testing etc. complete as directed by Engineer in-charge. It includes provision for making of alignment on city roads, making trial pits to investigate location of various under grounds services like telephone cables, gas pipe line, electric cable, existing pipe lines and sewer lines etc. arrangements for diversion of traffic and associated works etc. with supply of all necessary equipment, materials, labour and T&P etc. complete required for completion of work. The trenches shall be properly barricaded and fenced off wherever necessary. Red flags and caution boards during day and red lights during night shall be displayed so as to avoid any accidents. Note : Only SBR Rubber gaskets to be used as per IS-5382 and IS- 12820.
31150 mm dia
32Supply of following sizes of DI D/F sluice valve/scour valve with cap. Class-10 (working pressure 10kg/sqcm) confirming to IS:14846:2000 at Site of work, carting, lowering in already prepared trenches and fixing them in position, making flange joints including supply of all materials such as bolts, nuts, rubber insertion, white lead, testing etc. complete including all other necessary fitting and specials as per direction of Engineer in charge.
3380 mm dia
34100 mm dia
35125 mm dia
36150 mm dia
37200 mm dia
38250 mm dia
39300 mm dia
40350 mm dia
41Scoure valve
4280 mm dia
43Supply of following size Kinetic Double Air Valves as per IS : 14845 at site of work, carting, fixing in position including boring and threading in the main etc.complete including cost of boring the water main clamp with socket, G.I. medium duty, nipple and subsequent back filling etc complete.
4450 mm
45Supply of 80 mm dia size flanged type fire hydrant site of works of 80mm dia size flanged fire hydrant to site of work, fixing them in position for flanged joints s instucted by engineer in charge.
46Supply of all materials, labour, T&P etc. and construction of following chambers as per departmental type drawing and design.
47Surface box type
48Masonry type
49For air valve
50For fire Hydrants
51Construction of RCC thrusht block in 1:1.5:3 with cement, coarse sand and 20 mm guage stone gtit at bends of pipe including supply of all materials, labour, T&P etc. required for proper completion of work
52Mild steel TMT.Fe-500D in plain work such as reinforced concrete or reinforced brick work (for construction of RCC thrusht block) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and othorised overlapping shall be measured upto floor two level.
53Provision for crossing of nala, road, culvert including supply of casing with MS / DI pipe and specials, laying, jointing etc., T&P and arrangement of diversion of water, baricatings etc required, with dismantelling of drains and reconstruction of same as per type design of the existing drain, complete as per direction / approval of Engineer in charge. (More than 1.0 M)
54Making Nala crossing falling on alignment of pipe line including cost of D.I. pipe one no. (5.50m length) including supply of all materials, labour, T&P, etc complete required for proper completion of work.
55100 mm dia pipe
56150 mm dia pipe
57200 mm dia pipe
58250 mm dia pipe
59300 mm dia pipe
60350 mm dia pipe
61Permanent re-instatement of following type of road surfaces after laying of pipe line including supply of all materials, labour, T&P etc. required for completion of work. It also includes necessary excavation required for preparation of trench for reinstatement of road, disposal of surplus unserviceable material, watering, ramming, cleaning of surface for proper completion of the work as per directions of engineer-in-charge.
62Brick on edge with bricks (60 % New & 40% Old) laid dry, joints filled with local sand including preparation of base to proper slope and its ramming, spreading a layer of 10 cm depth of local sand over the subgrade and including supply of all materials, labour, T&P etc. required for proper complete of the work.
63Re-instatement of bitumen road as per specification including supply of all materials, labour, T&P etc. required for proper completion of work. To achive the required quality of work, graded material in appropriate quantity shall be supplied by the contractor. This material shall be used in filling of trenches only after succesfully testing of material with relevent IS code. Sample collection of GSB material, BM and SDBC will be done as required by engineer incharge. (Nagar Nigam Road)
64Re-instatement of bitumen road as per specification including supply of all materials, labour, T&P etc. required for proper completion of work. To achive the required quality of work, graded material in appropriate quantity shall be supplied by the contractor. This material shall be used in filling of trenches only after succesfully testing of material with relevent IS code. Sample collection of GSB material, BM and SDBC will be done as required by engineer incharge. (PWD Road)
65Providing and laying design mix cement concrete 100 mm thick of M-20 grade, in roads, using cement content as per design mix, using coarse sand and graded stone aggregate of 20 mm nominal size in appropriate proportions as per approved & specified design criteria, mixing with weigh batcher, laying at site, spreading and mechanically compacting by using needle and surface vibrators, levelling to required slope / camber, finishing with required texture over 100 mm thick base of GSB.
66Providing and laying of 80 mm thick M-30 grade C.C. rubber moulded (60% new and 40% old tiles) interlocking paver tiles over 30 mm thick fine sand bed and also including earth wotk in excavation in proper slope & camber including all materials, labour, T&P required for proper completion of work.
67Trenchless Crossing :- Survey site Investigation Planning design Drawings as per State Road manual and vetting / checked from State Road Divisional Office and taking NOC for trenchless crossing of National highway road and Railway track(crossing length 15m to 25m ) Road for of required dia Rising main pipe with casing pipe as required for proper completion of work required size of MS casing pipe as per drawing and as per (IS:3589 & made from confining to IS:2062) with 750 Micron PU coating internally and 250 micron anti corrosive bituminous paint externally by trenchless technology method at an average depth 3.60 mtr from normal ground level up to top of casing pipe including excavation & filling of Pit Dewatering arrangement Supporting system for soil also including supply and fixing of 2 no Sluice valve ISI Mark construction of sluice valve chamber etc. all complete work including supply & fixing specials in carrier pipe over main pipe as per specification given in the bid documents including supply of all materials labour T&P etc. for proper completion of work as per instruction of Engineer.
68Highway road / Railway crossing (upto 350 mm dia)
69Road Crossing - Excavation in foundation of trench of proper size in soil mixed with moorum, Shingle, Kankar, soft rock, hard rock, including refilling, dressing and ramming earth or sand or bajri, ballast, including providing, supply, carting, lowering, laying and jointing of casing pipe of RCC NP-3 with appropriate size, with rubber ring joint, sand filling in gap inside pipe, insertion of distribution pipe into the encasing pipe including supply of T&P, including concrete of 150 mm thick in with 40mm gauge brick ballast local sand and cement in proportion of 8:4:1, provision for barricading, labour for traffic diversion etc. Complete for proper completion of work as per instruction of Engineer.
70100 mm dia pipe
71150 mm dia pipe
72200 mm dia pipe
73250 mm dia pipe
74300 mm dia pipe
75350 mm dia pipe
76Supply & Installation of following size of HDPE / PE product pipe & spaicials by HDD method with nesessary jointing material like electro-fusion coupler, flanged joint, including preparing and setting up the plant and equipment, making string of new pipe-work material, installing new pipe string and making the system ready for commissioning by HDD operation including pipe pressure mains installation. all related civil and mechanical works like excavation, shoring/strutting, etc. drilling, stringing, reaming, and pulling back the new pipe-work on the designed bore path alignment, proper disposal of drilling fluid and back fill after completion all inclusive as per Ind STT:101-2018: Code of Practice for Horizontal Directional Drilling Technique suiting Indian conditions as directed by Engineer in-charge
7790 mm dia HDPE Pipe PN-6, PE 100
78110 mm dia HDPE Pipe PN-6, PE 100
79140 mm dia HDPE Pipe PN-6, PE 100
80160 mm dia HDPE Pipe PN-6, PE 100
81Construction of drinking water house connection with distribution mains (HDPE, AC, DI, PVC) including dismantling in all type of road, supply and carting of material (20 mm HDPE pipe PE-80/PN-16 from trench to outer wall/boundary wall, 15 mm GI pipe class-B average length 3 m, 15 mm GI elbow including HDPE electrofusion shaddle for HDPE pipe and DI strap saddle for DI pipe shall be used.1 No. brass tap shall be fixed inside the house of consumer as per IS 8931 and 8934, All 20 mm GI union, 20 mm, 1 No. 15 mm brass ferrule and other GI fitting and specials shall be according to IS 12183 & IS2065. , FTA & MTA and other compression fittings of 100% pure virgin (Georgefisher, kimplas) shall be provided. HDPE shaddle shall be fixed with electrofusion method. All fitting of water supply house connections shall be fixed them into trenches, fixing them in proper alignment and jointing and making hols in walls for crossing the GI pipe, fixing of GI pipe with minimum 3 hooks & repairing of hold after connection, necessary excavation for connection with temporary reinstatement of all type of road including supply of all machinery, T&P, labour etc. required for proper completion of the work as per directions of engineer-in-charge. For New pipe Line
82For 90 mm to 110 mm dia
83For 140 mm to 160 mm dia
84For 200 mm to 250 mm dia
85For 300 mm to 350 mm dia
86Permanent re-instatement of following type of road surfaces after laying of pipe line including supply of all materials, labour, T&P etc. required for completion of work. It also includes necessary excavation required for preparation of trench for reinstatement of road, disposal of surplus unserviceable material, watering, ramming, cleaning of surface for proper completion of the work as per directions of engineer-in-charge.
87Brick on edge with bricks (60 % New & 40% Old) laid dry, joints filled with local sand including preparation of base to proper slope and its ramming, spreading a layer of 10 cm depth of local sand over the subgrade and including supply of all materials, labour, T&P etc. required for proper complete of the work.
88Re-instatement of bitumen road as per specification including supply of all materials, labour, T&P etc. required for proper completion of work. To achive the required quality of work, graded material in appropriate quantity shall be supplied by the contractor. This material shall be used in filling of trenches only after succesfully testing of material with relevent IS code. Sample collection of GSB material, BM and SDBC will be done as required by engineer incharge. (Nagar Nigam Road)
89Re-instatement of bitumen road as per specification including supply of all materials, labour, T&P etc. required for proper completion of work. To achive the required quality of work, graded material in appropriate quantity shall be supplied by the contractor. This material shall be used in filling of trenches only after succesfully testing of material with relevent IS code. Sample collection of GSB material, BM and SDBC will be done as required by engineer incharge. (PWD Road)
90Providing and laying design mix cement concrete 100 mm thick of M-20 grade, in roads, using cement content as per design mix, using coarse sand and graded stone aggregate of 20 mm nominal size in appropriate proportions as per approved & specified design criteria, mixing with weigh batcher, laying at site, spreading and mechanically compacting by using needle and surface vibrators, levelling to required slope / camber, finishing with required texture over 100 mm thick base of GSB.
91Providing and laying of 80 mm thick M-30 grade C.C. rubber moulded (60% new and 40% old tiles) interlocking paver tiles over 30 mm thick fine sand bed and also including earth wotk in excavation in proper slope & camber including all materials, labour, T&P required for proper completion of work.
92Permission charges from PWD / Irrigation for crossing of canal, culvert and bund including all necessary arrangement & proper completion of the work as per directions of engineer-in-charge.
93Permission charges from highway & PWD road for crossing of risingmain and feedermain/ Distribution system including all necessary arrangement & proper completion of the work as per directions of engineer-in-charge.
94Soil Investigation, preparing plan & elevation carrying structural design as per relevant seismic zone and Construction of Pump House- Cum-Chloronome with foundation as per requirement of structural design & bypass chamber of size 3.60 x 3.0 M x 3.0 & 1.80 x 2.60 x 3.0 M Supply of all material T&P etc. as per site condition required for construction of Pump House as per typical drawing and design of department. including campus cleaning, removal of debries, bush cutting and disposal within municipal limit and filling of earth including supply of all materials, labour, T&P etc. required for proper completion of work as per direction of Engineer-in-charge.
95Construction of Staff Quarter (Size 7.50 M x 8.50 M) Soil Investigation, preparing plan & elevation carrying structural design as per relevant seismic zone and Supply of all meterials, labour, T&P, complete as per site condition and construction of Single Room Staff quarter with foundation as per requirement of structural design for pump operator, chaukidar, pump attendent as per departmental type design as per direction of Engineer in Charge.
96Supply of all material T&P etc. required for construction of Master Control Station Room (framed structure in M-25) as per drawing submitted by contractor and its approved by department. The structural design of Master Control Station Room shall be submitted by the contractor on the basis of safe bearing capacity of soil. The plinth level of Master Control Station Room shall be 60cm above from finished GL of the campus. The plinth area of the Master Control Station room 80 Sqm (10 x 8 M ), Height of meter Room -5.0m, antitermite treatment, 40 mm thick kota stone flooring over 100mm thick 1:1.5:3 CC; under ground electric fittings, cable trenches as per requirement of UPPCL and 100mm thick 1:1.5:3 CC apron with nominal reinforcement provinding 230mm brick protection wall of 60cm depth with 30cm sand filling shall be taken in consideration for structural design of Master Control Station Room as per direction of engineer in charge.
97Development work :-CONSTRUCTION OF BOUNDARY WALL, GATE WITH PILLER, SITE DEVELOPMENT & APPROACH ROADSupply of all materials, labour, T&P etc. and construction of framed structure in M-25 boundary wall as per departmental type design at water woks & tubewell campus including Ist class brick work in 1:6 cement & coarse sand mortar in foundation and plinth, 12 mm thick plaster in 1:4 with cement and coarse sand mortar for plinth shall be done on both side of brick work upto 15 cm below GL, First Class brick work in 1:4 cement and coarse sand mortar in super structure with necessary cutting and moulding of bricks, C.C. coping on boundry wall & RCC Piller in 1:2:4 cement, coarse sand and stone grit (10-12.5 mm), 12mm thick plaster with cement mortar in proportion of 1:6 consisting of cement and Banda(Ken)/ Hamirpur(Betava) sand over super structure brick work, Making groves 15 mm wide on wall plaster and outer surface of wall finish with two coat of weather coat-All Guard, Apex-Ultima(Premium Acrylic Smooth Exterior Paint with Silicon Additive) with one coat of priming coat of exterior primer over smooth base of white cement based wall putty such as Birla, J.K. wall Putty over the plastered wall surface to prepare the surface even and smooth including supply of all materials, labour, T&P etc. required for proper completion of the work.
98Supply and fixing of M.S. gate with RCC piler as per departmental design & drawing with ncessary hold fast, bush and ball bearing, sliding bolt and locking arrangement, painting etc. including supply of all material, labour, T&P etc. required for proper completion of the work for Water works campus (3.60 M wide main gate and 1.20 M wide wicket gate)
99Filling of earth in water works campus and TW/pump house campus including supply of carted earth including loading, unloding, levelling, dressing and ramming of the earth tc complete in all respect. Earth filling in the campus shall be done Contour survey of campus and prior written necessary permission of Engineer in charge.
100Supply & Laying of 80 mm thick cement concrete paver block of M-30 grade with approved colour, design & pattern inter locking tiles over 30 mm thick fine sand bed over 150mm thick GSB and also including earth wotk in excavation in proper slope & camber, brick work for side alignment including all materials, labour, T&P required for proper completion of work as per direction of Engineer in charge.
101Construction of 300 mm wide and 300 mm deep brick drain inside the water works campus including supply of all materials, labour, T&P etc required for proper completion of the work
102Construction of Artificial Recharging of Ground water hrough roof top rain water of pump house, bypass chamber’s water & overflow of O.H.T. supplying of all material, pipes, grates, etc. complete in all respect
103Providing and fixing of lighting arrangement in campus complete in all respect including supply of all material, labour T&P etc. as per approval and direction of engineer in charge
104Water works campus
105Tubewell compound
106Horticulture, plantation, Land scaping, beautification, internal path way at water works compound including supply of all material, labour T&P etc. as per approval and direction of engineer in charge
107Water works campus
108Tubewell compound
109Supply of following items as per ditrection of engineer in charge
110Office table (Godrej Make) (6x4 fit) with shelf and Glass
111Office table (Godrej Make) (8x4 fit) with shelf and Glass
112Computer table (Godrej Make) (4x3 fit) with Shelf
113Revolving Chair (Godrej Make)
114Office chair (Godrej Make)
115Computer chair Revolving (Godrej Make)
116Almirah (Godrej Make)
117Almirah Glass rak (Godrej Make)
118Split AC (1.5 tonne) Five star (Voltas, Hitachi, Blue star Make) with Stablizer
119Desktop (Hp, Dell Make) with Color Laser Printer (Hp Make) (i5 processor)
120Xerox machine (HP, Canon, Samsung Make)
121E&M works Constuction of 26 nos Tubewell 750, 800, 900 LPMTRANSPORTATION
122RIG MACHINE-Transportation of rig machine including Loading , unloading, Erection, Dismantling & labour etc complete in all respect .
123AIR COMPRESSOR-Transportation of 350 psi compressor including Loading , unloading, Erection, Dismantling & labour etc complete in all respect .
124O.P. UNIT-Transportation of 3 cusec op unit including Loading , unloading, Erection, Dismantling & labour etc complete in all respect .
125TUBE WELL ASSEMBLY-Transportation of TUBE WELL ASSEMBLY including Loading , unloading with labour etc complete in all respect .
126CONSTRUCTION OF TUBE WELL (DRILLING) As per IS 2800 (Part I & II)Drilling of BORE
127Barricading
128Logging of Bore
129Drilling of 600mm dia bore from G.L. to 65m BGL.
130Drilling of 500mm dia bore from 60 m BGL to 100m BGL.
131Drilling of 500mm dia bore from 100m BGL to160 m BGL.
132LOWERING OF TUBE WELL ASSEMBLY AND SHROUDING OF T.W. BY GRAVEL-Lowering of 300mm X 200mm dia tube well assembly in bore hole and shrouding of pea gravel between annular space of bore hole and T.W. assembly from G.L. to 160 m BGL.
133Lowering of 300mm dia MSERW 7.1mm thick plain pipe from GL to 60m BGL.
134Lowering of 200mm dia MSERW plain/slotted pipe 7.1mm thick from 60m BGL to 100m BGL.
135Lowering of 200mm dia MSERW plain/slotted pipe 7.1mm thick from 100m BGL to 145m BGL.
136MATERIALS
137TUBE WELL: ASSEMBLY (As per IS 4270, IS 8110)-300mm dia size MSERW housing plain/slotted pipe not less than 7.1mm thick including with 1 no 300 X200mm dia M.S reducer 16mm thick, 1 no M.S. well cap 12mm thick , M.S. ring 100X12mm thick, M.S. clamp ,T.W. Support (I Section) etc comp in all respect .(60m each tubewell)
138200mm dia MSERW not less than 7.1mm thick plain /slotted pipe including with M.S ring 100X12mm thick , 1 no M.S. bail plug , center guide etc comp in all respect
139PEA-GRAVEL (As per IS 4097)-1.60mm to 4.80mm size pea-gravel of Lalkuwan quarry duly screened, washed and proper stacking at site. (45 m3 each tubewell )
140DEVELOPMENT OF TUBE WELL-Development of tube well by 350 PSI air compressor
141Development of tube well by 350 PSI air compressor (60 hour each tubewell )
142Cutting of T.W. cover by gas cutter, re-welding of T.W. cover by Electric welding after complete development of work.
143Development of tube well by 3 cusec O.P. Unit
144Cutting of housing cover by gas cutter
145Development of tube well by 3 cusec O.P. Unit
146Re-welding of Tube well cover
147Watch & Ward during construction period including barricading
148Test of Chemical and bacteriological test
149PUMPING PLANT,STARTER,PIPING,VALVES, STABILIZER & ACCESSORIES for 750/800 lpm (zone-1,2,4,5,6,8,9)
1501.1- Clear water submersible pump complete with electric motor capable to operate on 380/420 volts 3 phase 50 Hz A.C. for 750/800 LPM. 60 Mtr. Head( both Tentative) and -one set for each tubewell consisting of contol panel having soft starter(item as mentioned below )along with bypass star delta starter,Capacitor Bank ,cable,all protection in all respect with all required material 2.MAIN PIPING AND VALVES: 100 MM dia 5.4 mm thick M.S. column pipe with both end flanged and groove for passing submersible cable in each length in 3.0m long 24 m with 1m long top pipe with cap (Dumdum) and sealing ring. -8 Nos fo each tubewell 2.1 - DI-D/F 90 Degree bend of size 100 mm dia -one no for each tubewell 2.2 -DI-A/F Tee of size 100 mm dia -one nos for each tubewell 2.3 - M.S. distance piece of 100 mm dia 1.00m long 1 Nos. and 1.5m long 2 No. - 3 nos for each tubewell 2.4 -M.S. enlarger/reducer of suitable size.- 1 nos for each Tubewell 2.5 -Reflex Valve 100 mm dia P.N. rating 1.0 Having following specification confirming (as per IS-14846-2000)-1 nos for each Tubewell 3. Tools and Spanners with Pipe Wrench etc. one set for each Tubewell 4. 2 tones capacity 4.5 m lift, spur geared chain pulley block Indef make P Type -one number for each tubewell 5-9 inch size pump protection ring -one no for each tubewell 6. Miscellaneous items - for each tubewell ( Resistant rubber sheet ,cut out, Danger plate,etc) 7. Painting of pumping plant materials -one job for each tubewell 8. Erection of pumping plant and Power wiring & earthing and other civil works. -one job for each tubewell
151PUMPING PLANT,STARTER,PIPING,VALVES, STABILIZER & ACCESSORIES for 900 lpm (zone-3,7,10,11)
1521.1- Clear water submersible pump complete with electric motor capable to operate on 380/420 volts 3 phase 50 Hz A.C. for 900 LPM. 60 Mtr. Head (both Tentative) and -one set for each tubewell consisting of contol panel having soft starter (item as mentioned below )along with bypass star delta starter,Capacitor Bank ,cable,all protections in all respect with all required material 2.MAIN PIPING AND VALVES: 100 MM dia 5.4 mm thick M.S. column pipe with both end flanged and groove for passing submersible cable in each length in 3.0m long 24 m with 1m long top pipe with cap (Dumdum) and sealing ring. -8 Nos fo each tubewell 2.1 - DI-D/F 90 Degree bend of size 100 mm dia -one no for each tubewell 2.2 -DI-A/F Tee of size 100 mm dia -one nos for each tubewell 2.3 - M.S. distance piece of 100 mm dia 1.00m long 1 Nos. and 1.5m long 2 No. - 3 nos for each tubewell 2.4 -M.S. enlarger/reducer of suitable size.- 1 nos for each Tubewell 2.5 -Reflex Valve 100 mm dia P.N. rating 1.0 Having following specification confirming (as per IS-14846-2000)-1 nos for each Tubewell 3. Tools and Spanners with Pipe Wrench etc. one set for each Tubewell 4. 2 tones capacity 4.5 m lift, spur geared chain pulley block Indef make P Type -one number for each tubewell 5-9 inch size pump protection ring -one no for each tubewell 6. Miscellaneous items - for each tubewell ( Resistant rubber sheet ,cut out, Danger plate,etc) 7. Painting of pumping plant materials -one job for each tubewell 8. Erection of pumping plant and Power wiring & earthing and other civil works. -one job for each tubewell
153Spare column pipe heavy duty
154Internal electrification of pump house and chlorinating room with wiring point for light with 1.0mm sq. P.V.C. insulated multi strand copper conductor cable in heavy gauge rigid P.V.C. conduit pipe on surface complete 14 S.W.G. copper earth continuously wire piano type switch and ceiling rose/angle batton holder on 3 mm. thichphenolic laminated back ligh sheet etc. complete in all respect as per I.E. rule including luminaries with 15 amp. Switch fuse unit.
155SITC of servo Stabilizer 30 KVA or suitable capacity (150-480v)
156SITC of servo Stabilizer 40 KVA or suitable capacity (150-480v)
157DI Sluice valves with motor operated actuator with positioning card valves of size 100 mm
158CE/UL Certified electromagnetic flowmeter of size 100mm
159SCADA compitable chlorinating system
160Soft starter 15 KW or suitable capacity
161Soft starter 22 KW or suitable capacity
1623.5 core 25 sq mm Aluminium Armoured cable from UPPCL transformer to t/w pump house
163CE/UL Certified hydrostatic type sub soil watel level transmitter for T/W
164Complete cabling of tubewell including all power & control cable of all equipment at pumphouse and OHT
165CE/UL Certified Pressure transmitter with display
166Automation of Units of T/W
167CE & UL Certified RTU/PLC in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & power supply with analog & digital parameters & features as specified for T/W to store and transmit data on GSM Backbone.RTU/PLC designed with logic to transfer data at multiple stations as specified in tender documents
168GSM/GPRS based wireless communication 4G modem for RTUs/PLC capable to transfer data from remote site to CS with all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender documents.
169CE/UL Certified Intelligent energy meters
170Auto phase reversal Unit 100 Amp or suitable capacity
171CE/UL Certified Surge Protector for control panel
172CE/UL Certified 7\\" HMl touch screen suitable to communicate with PLC/RTU for Local display and control of Process Parameters
173Control panel with IP 54 protection, industrial grade for all equipments( Separate for control 24 V and power equipments alongwith 1 kva ups with battery
174Installation,Testing and commissioning
175Trial run 3 months
176S.I.T.C of followings E/M items at OHT,
177CE & UL certified Radar type level tranmitter for OHT
178Motor Operated Actuator with positioning card with DI Sluice valve 350 mm or suitable dia.
179Motor Operated Actuator with positioning card with DI Sluice Valve 300 mm or suitable dia.
180CE / UL certified Electromagnetic flowmeter of size:350mm dia .or suitable capacity
181CE / UL certified Electromagnetic flowmeter of size:300mm dia .or suitable capacity
182Dismantelling joint 350 mm or suitable dia
183Dismantelling joint 300 mm or suitable dia
184Residual Chlorine Analyser
185Control Station (SCADA system shall remain operational 24 hours a day, 7 days a week(24x7 live monitoring) to facilitate continous, real time monitoring of site parameters)
186CE/UL & BIS certified industrial grade LED monitor with latest configuration as per technical specification of size- 65 \\"
187Desktop/PC with i5/i7 configuration as per technical specification
188CE/UL Certified 3 KVA UPS or suitable capacity With battery as per tech specification
189Full development version/Run Time version of required TAGS SCADA software with customization of software for LCS as per specfication given in tender dpcuments alongwith the following:- 1. It must be ensured that the software development file (app extension) is transferred along with the corresponding run-time file, so that modifications in the software can be made in the future as required.2. The software license must be registered in the name of Jal Nigam, in the format decided by the manufacturing company as the End User, and the license must also be verified by the manufacturer.3. All support and updates must be provided by the vendor. After the warranty period, all Perpetual Rights must belong to Jal Nigam so that the software can be used indefinitely.4. A Static IP must be used for the SCADA system (in case static IP not available contractor shall arrange cloud based system including cloud hosting, data storage, communication integration & associated services for minimum period of 10 years)
190GSM Based wireless/broadband/ Equivalent communication system for PLC Capable to transfer/received data & gather data from remote site to control station, All accessories included signal enhancer with antenna and all running expenses till DLP
191CE/UL certified Firewall for network protection
192Surge protector for ethernet communication protection
193CE/UL Certified industrail grade ethernet switch
194CANON/HP/Equivalent LASER printer 1018 or equivalent
195Complete cabling of tubewell including all power & control cable for T/W
196Security Survelliance IP Camera with recorder
197Installation,Testing and commissioning with required furniture and A/C etc.
198Trial run for 3 months
199Trail and Run
200Sodium Hypochloride for three month for 26 nos tubewell
201Provision for operation of 3 month for 26 nos tubewell Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58615878
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 08-12-2026
Authority
Authority Name Uttar Pradesh Jal Nigam
Work Description Tender for Surveying, Soil Investigation, Engineering, Design, Supply Of All Materials, Labour, T&P Etc. Required For Completion Of Following Works Of Bakshi Ka Talab Nagar Panchayat Water Supply Scheme Distt. Lucknow Under Amrut 2.0 Programme On Turn-Key Basis:Rcc Ohts, Rising Main, Distribution System Including House Connections, Scada Room, Chlorination Room, Meter Room, Panel Room, Boundary Wall & Site Development Works Etc. And Other Appurtenant Works Including Scada And Automation As Per Specifications In Tender Document. The Scope Of Work Also Includes Provisions & Specification As Specified In Tender Documents, Testing & Commissioning, Trial & Run For 3 Months, Defect Liability Period Of 12 Months For Civil Works & 24 Months For E/M Works After Completion Of Successful Trial Run. All Completed And Commissioned Work Under Bakshi Ka Talab Nagar Panchayat Water Supply Scheme Distt. Lucknow Under Amrut 2.0 Programme Shall Be Handed Over To Executive Officer, Nagar Panchayat Bakshi Ka Talab, Lucknow After 3 Months Of Successful Trial Run Period.
Basic Detail
Tender No 2766/M-13/205, dated 06-11-2026
Bidding Type Tender
Location
City Lucknow
State Uttar Pradesh
Key Dates
Publish Date 19 Nov 2026
Submission Date 08 Dec 2026
Open Date 09 Dec 2026
Finance
Tender Value Ref. Documents
Tender Fee 23600
EMD 99.65 Lakhs
Exemption Not Available
Document List
60b539bc-6e19-4472-a404-309a1294dacf.html
Bakshikatalabtenderdocu.pdf
BOQ_2298899.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Dec 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

60b539bc-6e19-4472-a404-309a1294dacf.html

pdf

Bakshikatalabtenderdocu.pdf

xls

BOQ_2298899.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender