Tender For Annual Repairs And Maintenance Of Electrical Installations At Fsd, Eluru For The Fy 2026-27.Sh: Carrying Out General Maintenance Works To Depot Office And Godowns, Replacement Of Damaged Underground Cable And Other Allied Works.
Tender Overview
Project Description
Tender for Annual Repairs And Maintenance Of Electrical Installations At Fsd, Eluru For The Fy 2026-27.Sh: Carrying Out General Maintenance Works To Depot Office And Godowns, Replacement Of Damaged Underground Cable And Other Allied Works.
BOQ
| Sl. No. | Item Description |
| 1 | Providing and fixing following dia G.I. pipe (Light class) on pole/wall complete with clamps and other connected etc. as required. |
| 2 | Supplying of PVC/XLPE armoured cable with aluminium conductor 1.1 KV Grade confirming to IS 7098 (part I)1988 with upto date amendments of the following size at the site of work. |
| 3 | 3 X 10 Sqmm |
| 4 | 4 X 16 sqmm |
| 5 | Supplying and fixing of light class G.l. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. |
| 6 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required |
| 7 | 100mm Dia |
| 8 | Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 9 | Upto 35 Sq. mm (Clamped with 1mm thick saddle) |
| 10 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 11 | Upto 35 Sq. mm |
| 12 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 13 | Upto 35 Sq. mm |
| 14 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 15 | 4 way (4 + 12), Double door |
| 16 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 17 | 12 way , Double door |
| 18 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 19 | Single pole |
| 20 | Single pole Neutral |
| 21 | Triple pole |
| 22 | Triple pole and neutral |
| 23 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 24 | Group C |
| 25 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 26 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 27 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 28 | 5/6 A switch |
| 29 | 3 pin 5/6 A socket outlet |
| 30 | Supplying and fixing of following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required |
| 31 | 12 Module (200mmX150mm) |
| 32 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 Amodular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 33 | Supplying and fixing 30 A,415V, TPN Industrial type socket outlet with 4 pole and earth, metal enclosed plug top alongwith 30 A \\"C\\" curve, TP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc, as required. |
| 34 | Supplying and fixing 20 A, 240V, SPN Industrial type socket outlet with 2 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc, as required. |
| 35 | LED Batten light (System lumen efficacy ≥105 <120lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following bodymaterial and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electricalcircuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumptionshould not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required withMinimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LEDjunction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 36 | 18- 22 Watt |
| 37 | Supplying, installation, testing and commissioning of 1200 mm 20W LED Aluminium LTT8-20 tubelight with extruded Al body (single side connection) with in-built driver and efficacy of 100 lumens/W by fixing in the existing T8 LED box type luminaire with G13 lamp holders using necessary clamps and also dismantling the existing tube including giving connections etc. at site of work as required.(NABL certified as per ISO/IEC specification) |
| 38 | Supplying, installation, Testing and commissioning of 70 watt LED Well Glass (Clear type) made of high pressure die cast aluminium housing and fixing on truss /wall/pole with suitable clamps and nut & bolts including connection etc., as required (as per latest ISO/IEC Specification)(IP66 protection, Luminar efficacy > 120Lm/W, CRI>75) |
| 39 | Supplying, installation, Testing and commissioning of 40 watt LED Well Glass (Clear type) made of high pressure die cast aluminium housing and fixing on truss /wall/pole with suitable clamps and nut & bolts including connection etc., as required (as per latest ISO/IEC Specification)(IP66 protection, Luminar efficacy > 120Lm/W, CRI>75) |
| 40 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI ≥ 70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LEDjunction temperature shall not rise above 90°C). |
| 41 | 100 watt |
| 42 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LEDjunction temperature shall not rise above 90°C). |
| 43 | 200 watt |
| 44 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LEDjunction temperature shall not rise above 90°C). |
| 45 | 250 watt |
| 46 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output.LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) |
| 47 | 72 watt |
| 48 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 49 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 50 | Supplying of 300 mm sweep, min. of 1350 RPM speed, min. of 1160 CMM air delivery Heavy Duty exhaust fan with Sturdy metal body with metal blades & Metal louvers for protection from birds and foreign matter etc., as required at the site of work. |
| 51 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. asrequired. |
| 52 | Upto 450 mm sweep |
| 53 | Supplying , installation, testing and commissioning of 35 Watt LED 5700K Post top Lanthern made up of pressure die cast aluminium housing of new generation, energy saving, environmental friendly, long life astheticatly design symmetrical light distribution spun aluminium landscape luminaire with high power LEDs as light source with IP 65,IK 07, avg life- 50000 hours with lumen efficacy of >140 lm/W, System efficacy of > 70 lm/W,colour temp 5700 K,THD( %) < 10 and fixing on pole with suitable clamps and nut bolts including giving connection testing etc at site of required (ISI Certified) |
| 54 | Supplying and fixing loop in loop out boxes (PVC Sintex Box) of size 140mmx140mmx95mm with PVC enclosure 1 Nos, 2/4 way strip connector including testing as required. |
| 55 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 56 | 3 X 10 sq. mm (22 mm) |
| 57 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 58 | 4 X 16 sq. mm (28 mm) |
| 59 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 60 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 61 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 62 | Supplying and drawing of 1.5 Sq.mm, Three core PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts, conforming to IS: 694 in the existing surface/ recessed steel/ PVC conduit as required. |
| 63 | Supplying and fixing of 300 mm x 300 mm size metalic frame cover fabricated with 25 mm x 25 mm x 3 mm thick angle iron welded construction frame structured and 1.6 mm thick M. S. sheet cover plate panel with double hinges and knobe type locking arrangement including painting, making recess in wall of 300 mm Width x 300 mm Height x 150 mm Depth, masonary, plastering & finishing the good. |
| 64 | Supplying and fixing of 600mm x 600mm size x 3 mm thick M. S. sheet cover plate panel with double hinges and knobe type locking arrangement including painting, making recess in wall, masonary, plastering & finishing the good. |
| 65 | Dismantling of pole/street light standard/strut embedded in brick ballast foundation etc as required. |
| 66 | CREDIT ITEMS |
| 67 | Dismantled metal scrap such as MS Conduit Pipes, GI Boxes, GI wires, Iron pipes, 4 way/2 way cross arms , insulators etc., |
| 68 | Dismantled Poles shifting out from depot premises as credit |
| 69 | Dismantled DBs, switch gears with its accessories |
| 70 | Dismantled obsolete Tubelight fittings/Street lights/HPSV Lamps with its accessories etc., |
| 71 | Dismantled copper insulated wire Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender