Tender For Construction Of 66 Houses In The Multi-Storey Building (B+Gf+16 Floor) Over Partial Constructed (B+Gf+2 Floor) And Remaining Non-Tower Area/ Basement On Plot No-Gh4 , Pocket-C Madhuban Bapudham Ghaziabad (Part-A).
Tender Overview
Project Description
Tender for Construction Of 66 Houses In The Multi-Storey Building (B+Gf+16 Floor) Over Partial Constructed (B+Gf+2 Floor) And Remaining Non-Tower Area/ Basement On Plot No-Gh4 , Pocket-C Madhuban Bapudham Ghaziabad (Part-A).
BOQ
| Sl. No. | Item Description |
| 1 | PART-1: Carriage of earth by mechanical transport including loading, unloading and stacking, lead up to 10 km (complete as per direction of Engineer-in-Charge). DSR 2023 1.1 |
| 2 | Providing, Supplying, Installing, Testing and Commissioning of Precast Polymer Concrete/High Performance Concrete (HPC) Linear Surface Drainage System conforming to EN 1433 or equivalent international standard, complete with drainage channels of nominal width 150 mm, gratings/slot tops of approved material and load class as specified, factory-made channel joints, sealable connections, sump unit with outlet connection, end caps, locking arrangements and accessories. The work shall include excavation, foundation preparation, concrete bedding and haunching, alignment, joint sealing, fixing, backfilling, reinstatement of adjoining pavement/road surface and all labour, materials, tools, tackles, equipment and incidentals required for complete installation as per approved drawings, manufacturer's specifications and directions of the Engineer-in-Charge. (MR- civil - 01) |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.All kinds of soil. DSR 2023 2.6.1. |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. DSR 2023 2.25. |
| 5 | Waterproofing of Raft/Grade Slab: Providing and applying HDPE based self adhesive fully bonded, UV Stable, weldable composite waterproofing sheet membrane system comprising of a virgin HDPE layer, coated with a high bond strength pressure sensitive adhesive, covered by a weatherproof protective inorganic sand sprinkled layer, and provided with heat weldable selvedge for below ground waterproofing of reinforced concrete structures. HDPE composite waterproofing sheet membrane system should have thickness of Min. 1.5 mm with sand finish at top, bare HDPE membrane thickness 1.1-1.2 mm The membrane should have strong bonding property between the top sanded layer and fresh concrete, so that there is no lateral water migration between membrane and the structural concrete of underground structure.The overlaps min. 100 mm on side laps to be secured using hot air welding with automatic selfpropelled machine like Uniroof, Varimat or Twiny. The end overlaps, the sand to be removed using hot shovelling HDPE membrane to be exposed and joint to be secured using hot air wleding same as that of side overlaps. The membarne is loose laid onto prepared substrates or formwork before fixing reinforcement and casting concrete. The adhesive layer is activated when the concrete is poured on the surface and forms a permanent bond with the fresh concrete which will prevent the ingress of water around the structure. Reinforcement can be directly laid on top of the membrane and it does not require screed protection fully bonded as per suppliers recommendations.The membrane shall have a tensile strength ~25 MPa according to ASTM D412; elongation 550% according to ASTM D412; resistance to static puncture ~1000 N according to ASTM E154; adhesion in peel~1500 N/m according to ASTM D903 mod; Water tightness > 71 m of hydrostatic head according to ASTM D 5385 mod and should pass foldability at -23 °C according to ASTM D1970 and UV exposure resistance of 30 days. Membrane should be supplied with manufacturer's Material Test Certificate (MTC) & membrane should be installed in strict accordance with manufacturer's method statement through trained applicator. (MR- civil - 02) |
| 6 | Providing and Laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level.1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size). DSR 2023 4.1.8 |
| 7 | Providing, supplying, installing, testing and commissioning Smart Digital Door Lock (Neo Pro View or approved equivalent) with multiple modes of access including Fingerprint, Wi-Fi, RFID Card, Passcode, Remote Access and Mechanical Key. The lock shall be provided with integrated video monitoring screen, built-in camera and doorbell, mobile app connectivity for remote monitoring and unlocking, privacy mode, passage mode, spy code function, anti-theft alarm, anti-prank alarm, low battery indication, emergency power backup and all other standard accessories complete in all respect as approved by Engineer-In-Charge. (MR- civil - 04) |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for. Foundations, footings, bases of columns, etc. for mass concrete. DSR 2023 5.9.1. |
| 9 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. DSR 2023 5.9.2 |
| 10 | Suspended floors, roofs, landing, balconies and access platform. DSR 2023 5.9.3 |
| 11 | Shelves ( Cast in situ). DSR 2023 5.9.4. |
| 12 | Lintels,beams,plinth beams,girders, bressumer sand cantilevers. DSR 2023 5.9.5 |
| 13 | Columns,Pillars, Piers, Abutments, Posts and Struts. DSR 2023 5.9.6. |
| 14 | Stairs, (excluding landings) except spiral-staircases. DSR 2023 5.9.7. |
| 15 | Edges of slabs and breaks in floors and walls Under 20 cm wide. DSR 2023 5.9.16 |
| 16 | Weather shed, Chajjas, corbels etc., including edges. DSR 2023 5.9.16 |
| 17 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. DSR 2023 5.22.6. |
| 18 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. DSR 2023 5.22A.6. |
| 19 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level. Concrete of M30 grade with minimum cement content of 350 kg /cum. DSR 2023 5.33.1.2 |
| 20 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level. Concrete of M30 grade with minimum cement content of 350 kg /cum. DSR 2023 5.33.2.2 |
| 21 | Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof. DSR 2023 5.38. |
| 22 | Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-InCharge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063).Wall Joint of 200 mm gap. DSR 2023 5.45.3. |
| 23 | Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates an universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement.The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall conform to ASTM 6063).Roof Joint of 200 mm gap. DSR 2023 5.46.3. |
| 24 | Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for each four floors or part thereof by mechanical means. DSR 2023 6.5. |
| 25 | Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100 mm/ 125 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. DSR 2023 6.38. |
| 26 | Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). DSR 2023 6.47. |
| 27 | Providing and fixing factory made System aluminium glazed/wire mesh windows/doors comprising of frame, sash and mullion/coupler (where ever required) extruded profiles conforming to IS 733 and IS 1285 in any shape, design, aluminium extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM microwave cured gasket, hardware, anchor fasteners for fixing frame to finished wall, plastic packers, plastic caps and necessary screws etc. The profiles made out of 6063-T6 grade Aluminium alloy and tempered. All the visible and non-visible surfaces shall have highly durable polyester Powder coating of 60 – 80 micron thickness confirming to AAMA 2604 of approved make and shade or anodized to required shade according to IS 1868 with minimum anodic thickness of grade AC 15. Materials for hardware shall have at least corrosion resistance of 240 hrs when subjected to neutral salt spray testing. All window hardware shall be tested for minimum 15,000 cycles and all door hardware shall be tested for minimum 25000 cycles. Profile of frame, sash & mullion (if required) shall be either 45° mitre joint and 90° square cut joint at the corners, true right angles, and joints to be finished neatly to hairlines, joining by Cleat with Allen screw of SS 304 grade including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming specification & direction of Engineer-in-Charge.Distance between two fasteners shall be maximum 500mm and distance from window corner / mullion / transom shall be 150 ~ 250mm. Section of aluminium profiles shall meet the design wind pressure in accordance with IS 875 (Part-3). Structural design calculations to be provided by the manufacturer and vetted drawings (from approved IIT/NIT) shall be submitted by the contractor for approval of the Engineer-in-Charge. Contractor should also make all necessary arrnagement for factory visit of Engineer-in-Charge or his representative for approval of the manufacturer. Nothing extra shall be paid on this account.Aluminium three track sliding windows with 6mm thick toughened glass (or as per approved drawing), all necessary fittings like flush handles, multipoint locks etc. all complete as per drawings and directions of Engineer-in-charge. DW and SD. (MR- 06 G) |
| 28 | Factory Made Powder Coated Aluminium Fibre Mesh Door comprising aluminium frame with powder-coated finish and fibre insect mesh, complete with suitable hinges, locking arrangement, handles, frame sections, fixing brackets, accessories and all necessary fittings, factory fabricated, supplied and fixed in position complete as per approved drawings and directions of Engineer-in-Charge. (MR-08 A) |
| 29 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, windows sills, facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels.Granite stone slab colour black, Cherry/Ruby red.Area of slab upto 0.50 sqm. DSR 2023 8.2.2.1. |
| 30 | Area of slab over 0.50 sqm DSR 2023 8.2.2.2. |
| 31 | Aluminium Casement windows (side hung) with handles, multipoint lock system, 6mm toughened glass (or as per approved drawing) etc. all necessary fittings as per drawing and directions of Engineer in Charge. MR- 09 |
| 32 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood. DSR 2023 9.1.1. |
| 33 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. DSR 2023 9.20.1. |
| 34 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). DSR 2023 9.23 |
| 35 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. DSR 2023 9.83. |
| 36 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm. DSR 2023 9.96.1. |
| 37 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mm - Door. DSR 2023 9.97.2. |
| 38 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm. DSR 2023 9.100.1. |
| 39 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised ( anodic coating not less than grade AC 10 as per IS:1868)transparent or dyed to required colour or shade with necessary screws etc.complete: Single rubber stopper. DSR 2023 9.101.1 |
| 40 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.0 mm thick. DSR 2023 9.127.2. |
| 41 | Providing and fixing factory made ISI marked us-insulated metal fire rated doorset assembly, for all egress applicattons areas like utility rooms and service areas etc., consisting of galvanized iron steel frame and single leaf shutter including necessary hardware accessories conforming to FD 120 UD classification of IS: 3614:2021 with fire rating of 120 minutes integrity. The door frame and shutter shall be made out of minimum 1.20 mm thick GI Sheet with minimum 120 GSM Zinc coating as per IS: 277. The entire fire rated doorset assembly shall be tested in unlatched condition as per IS 17518 (Part - 1): 2022Frame : The frame shall be of minimum size 90 x 60 mm with grooved profile to take appropriate fire rated smoke seal, having mitred cut joints (self tab/screwed assembled at site) and provided with appropriate reinforcement suitable for taking hardware and flush fixing as per IS: 4351. The smoke seal material shall be of EPDM tested in accordance with ASTM E- 84 of minimum 10 x 4 mm, fixed within the inbuilt groove or stuck with adhesive on the entire perimeter of the frame. The door frame shall be fixed in all three sides to masonry wall opening with CSK/Hex headed fasteners of minimum 8 mm dia size and minimum 80 mm long with 8mm dia polyamide sleeves @ 5 numbers at each on vertical side and 2 numbers on top side.Door shutter: The double skinned single leaf door shutters shall be consisting of minimum 46 mm thicI‹ and having box like structure slots cut and holes punched, for fixing of hardwares with stiffners as per IS: 16074 including resin bonded honey comb paper core infill material of density 5 kg/cum. Door leaf shall be provided with vision panel having maximum area of 0.12 sqm, of 120 minute fire rated minimum 6 mm thick clear borosilicate glass pane fixed with clip-on arrangement and fire rated ceramic tape having minimum size 13x2 mm to be fixed all around the glass on both the sides. The door shutter shall be mounted on the frame with SS 304 grade ball bearing butt hinges as per EN 1935 : 2002 or butt hinges as per IS 12817 of minimum size 100x75x3 mm @ 5 numbers hinges upto 2400mm height or as per test evidence, whichever is more, fixed with M6 25 screws. All doors shall be factory prepared for receiving appropriate hardware and provided with necessary reinforcement for hardware accessories. Accessones Hardware: Fire doorset shall be provided with one number fire rated SS 304 grade mortise dead lock, 5&80 mm backset with minimum 20 mm square forend with allen key including Escutcheon of stainless steel (SS304) with 65/70 mm cylinder both side key conforming to EN'12209 / IS 16015:2022, one pair of D type pull handle of stainless 6teel (SS304) of minimum 22 mm dia centre to centre distance of 300 mm back to back fixing with spindle, one number 120 minutes fire rated surface mounted heavy duty door closer of size EN 3-5 with standard arm of desired finish conforming to IS: 3564/EN1154. Finishing: Both frame and door shutters shall be factory finished with polyester powder coating of minimum 50 microns thick and shall have passed salt spray test as per IS:13871 of approved colour and shade all complete as per manufacturer's specifications and as per direction of the Engineer-in-charge.Installation: The hollow space in the door frame shall be filled / injected with fire rated self extinguishing type polyurethane foam (PUF) after installation at site of work. the rate shall be inclusive of complete fire rated door assembly, supply and installation by the approved manufacturer.Single leaf uninsulated metal fire rated doorset of FD 120 UO ciassification with 120 minutes integrity as per IS 3614:2021 -- For non egress applications like utility room and service area etc. DSR 2023 9.162D.1. |
| 42 | Providing and fixing factory made ISI marked partially insulated metal fire rated doorset assembly, for staircase / exit pathway and refuge areas applications, consisting of galvanized iron steel frame and single leaf shutter including necessary hardware accessories, conforming to FD 120 PI classification of IS 3614 .2021 with fire rating of 120 minutes integrity and 30 minutes ‹nsulation. The door frame and shutter shall be made out of minimum 1.20 mm thick GI Sheet with minimum 120 GSM Zinc coating as per IS. 277. The entire fire rated doorset assembly shall be tested in latched condition as per IS 17518 (Part -1) 2022Frame: The frame shall be of minimum size 90 x 60 mm with grooved profile to take appropriate fire rated smoke seal, having mitred cut joint (self tab/screwed assembled at site) and provided with appropriate reinforcement suitable for taking hardware and flush fixing as per IS 4351. The smoke seal material shall be of EPDM tested in accordane with ASTM E-84 of minimum size 10x 4mm, fixed within the inbuilt groove or stuck with adhesive on the entire perimeter of the frame. The door frame shall be fixed to the three sides to masonary wall opening with CSK/Hex headed fastner of minimum 8 mm dia size and minimum 80mm long with 8mm dia Polyamide sleeves @ 5 numbers at each on vertical sides and 2 numbers on horizontal top side.Door shutter: The double skinned single leaf partially insulated fire rated door shutters shall be consisting of minimum 50 mm thick and having box like structure, slots cut and holes punched, for fixing of hardwares with stiffners as per IS: 16074 including resin bonded mineral wool / ceremic wool infill material of minimum density 96 kg/cum. Door leaf shall be provided with vision panel, having maximum area of 0.06 sqm, of 120 minute fire rated minimum 6 mm thick clear borosilicate glass pane fixed with clip-on arrangement and fire rated ceramic tape having minimum size 13x2 mm to be fixed all around the glass on both the sides. The intumescent seal of minimum size 15x1.5 mm or of size as her test evidence shall be fixed on all the three edges of the door leaf. The door shutter shall be mounted on the frame with SS 304 grade ball bearing butt hinges as per EN 1935 : 2002 or butt hinges as per IS 12817, of minimum size 100x75x3 mm @ 5 numbers hinges upto 2400mm height or as per test evidence, whichever is more, fixed with M6 25 screws. All doors shall be factory prepared for receiving appropriate hardware and provided with necessary reinforcement for hardware accessories.Hardware Accessories: Fire doorset assembly shall be provided with one number of Single point Panic push bar (cross bar) device of desired finish as per EN 1125 and one number external trim including half cylinder of 42mm long with one side key as per EN 1125. One number heavy duty door closer of size EN 3-5 with standard arm, of desired finish (suitable upto 1250 mm door width) conforming to IS 3564/EN 1154.Finishing: Both frame and door shutters shall be factory finished with polyester powder coating of minimum 50 microns thick and shall have passed salt spray test as per IS:13871 of approved colour and shade all complete as per manufacturer's specifications and as per direction of the Engineer-in-charge Installation: The hollow space in the door frame shall be filled / injected with fire rated self extinguishing type polyurethane foam (PUF) after installation at site of work. The rate shall be inclusive of complete fire rated door assembly, supply and installation by the approved manufacturer.Single leaf Partially Insulated metal fire rated doorset of FD 120 PI classification with 120 minutes integrity and 30 minutes insulation as per IS 3614:2021 - For Staircase/ Exit pathway / Refuge area etc. DSR 2023 9.162E.1. |
| 43 | Providing and fixing factory made ISI marked partially insulated metal fire rated doorset assembly for staircase / exit pathway and refuge areas applications. consisting of galvanized iron steel frame and double leaf shutter including necessary hardware accessories, conforming to FD 120 PI classification of IS 3614 :2021 with fire rating of 120 minutes integrity and 30 minutes insulation. The door frame and shutter shall be made out of minimum 1.20 mm thick GI Sheet with minimum 120 GSM Zinc coating as per IS: 277. The entire fire rated doorset assembly shall be tested in latched œndition as per IS 17518 (Parl -1) 2022 Frame: The frame shall be of minimum size 90 x 60 mm with grooved profile to take appropriate fire rated smoke seal, having mitred cut joint (self tab/sczewed assembleö at site) anô provided with appropriate reinforœment suitable for taking hardware and flush fixing as per IS 4351. The smoke seat material shall be of EPDM tested in accordane with ASTM EÆ 4 of minimum size 10* 4mm, fixed within the inbuilt groove or stuck with adhesive on the entire perimeter of the frame. The door frame shall be fixed to the three sides to masonary wall opening with CSK/Hex headed fastner of minimum 8 mm dia size and minimum 80mm Iong hot dip galvanized with 8mm dia Polyamide sleeves @ 5 number at each on vertical side and 3 number on lop side. Door shutter: The double skinned double deal parlially insulated door shutters shall be consisting of minimum 50 mm thickness and having box like structure, slots cut and holes punched, for fixing of hardwares with stiffners as per IS: 16074 including resin bonded mineral wool / ceramic wool infill material of minimum density 96 kg/cum. Each door leaf shall be provided with vision panel having maximum area of 0.06 sqm, of 120 minute fire rated minimum 6 mm thick clear borosilicate glass pane fixed with clip-on arrangement and fire rated ceramic tape having minimum size 13x2 mm to be fixed all around the glass on both the sides. The intumescent seal of minimum size 15x1.5 mm or of size as per test evidence shall be fixed on all the three edges of the door leaves. Integral astragals to be provided for double teaf door on the meeting style each on active and inactive leaf. The door shutters shall be mounted on the frame with SS 304 grade ball bearing butt hinges as per EN t935 : 2002 or butt hinges as per IS 12817, of minimum size 100x75x3 mm @ 5 numbers hinges upto 2400mm height or as per test evidence, whichever is more fixed with M6 25 scraws. AII doors shall be Factory prepared for receiving appropriate hardware and provided with neccessary reinforcement for hardware accassories. Accessories Hardware : Fire doorset assembly shall be provided with one number of single point panic push bar across bar) for active leaf and one number double point panic push bar across bar) with bottom strike of desired finish with verticle shoot bolt on top and bottom for inactive leaf of double leaf door as per EN 1125, one number external trim with half cylinder 42 mm long with one side key as per EN 1125, two number heavy duty door closers of size EN 3-5 with standard arm with of desired finish (suitable for 1250 mm wide door leaf} conforming to IS 3564 / EN 1154, and one number surface mounted door coordinator for sequencing of closing.Finishing: Both frame and door shutters shall be factory finished with polyester powder coating of minimum 50 microns thick and shall have passed salt spray test as per IS:13871 of approved colour and shade all complete as per manufacturer's specifications and as per direction of the Engineer-in-charge.Installation: The hollow space in the door frame shall be filled / injected with fire rated self extinguishing type polyurethane foam (PUF) after installation at site of work. The rate shall be inclusive of complete fire rated door assembly, supply and installation by the approved manufacturer. Double leaf partially Insulated metal fire rated doorset of FD 120 PI classification with 120 minutes integrity and 30 minutes insulation as per IS 3614:2021 for Staircase/ Exit pathway / Refuge area etc. DSR 2023 9.162F.1. |
| 44 | Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/sqm) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-Charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredited labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm. DSR 2023 9.164. |
| 45 | Providing and laying engineered wooden flooring (Oak Plank Exquisite or approved equivalent) complete with 2 mm foam underlay, 1 mm polyethylene sheet, adhesives/accessories (where required), edge finishing, cutting, fitting, labour, transportation, loading/unloading, wastage, and all incidental works, complete as per manufacturer's specifications and directions of the Engineer-in-Charge. MR- 10 |
| 46 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. DSR 2023 10.18. |
| 47 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. DSR 2023 10.25.2. |
| 48 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.M.S. tube. DSR 2023 10.26.1. |
| 49 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size - Size of Tile 1000 x 1000 mm. DSR 2023 11.41A.1.5. |
| 50 | Glazed Vitrified tiles Matt/Antiskid finish of size . Size of Tile 600 x 600 mm. DSR 2023 11.41A.3.1. |
| 51 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.. Size of Tile 1000x1000 mm. DSR 2023 11.46.4. |
| 52 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm. DSR 2023 11.47.2 |
| 53 | Providing and laying flamed finish/leather finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish/leather finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. DSR 2023 11.55.1. |
| 54 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent. DSR 11.56.1. |
| 55 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase. DSR 2023 21.21.1 |
| 56 | Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing ‘C’ wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with the help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with the help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with : GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. DSR 2023 12.54.1 |
| 57 | Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittance tested as per ASTMC 1549 and ASTMC 1371 respectively), VOC less than 10 cc/gm. The coating thickness and the methodology of application shall be strctly as per manufacturer’s specifications and as approved by Engineer-in-Charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc., washing with water all complete. The contractor shall give guarantee for the perfomance of SRI and also the durabitity of coating, all complete as per direction of Engineer-in-Charge. DSR 2023 12.63. |
| 58 | Fabrication, supply & Installation of New clear line glass railing system for Straight area of Heavy duty aluminum U Type Hollow walls Base channel ( HWBC) (OZRF-NCL-SYS-HWBC-AL) AL-6063 grade with Powder Coated finish of size 54( wide)x125 mm( height). Glass Specs. is 13.52mm thk laminated (6mm Thk. Clear Toughened + 1.52 PVB (Make-Winlite)+ 6mm Thk Clear Toughened) for Straight area . Clear Glass Height 560mm. to be GRIPPED with fixing kit (OZRF-NCL-ACC-KIT-13.52MM). each at maximum 250mm cc to cc . glass should be lifted from base by Solid Nylon L Block separates at least 4 nos/ meters. HWBC to be fixed with mechanical GI Anchor M10x120 mm. Glass should be fixed with completely dry system so that in case of breakage it can be changed without any silicon cutting and very fast as well. exposed edges of HWBC (if any) to be covered with end caps. The Top Edge of glass will be covered with AL grade Powder coated Finish -Slotted Square handrail of OZRAC-UTB-40x40 (AL) fixed with EPDM Gasket at the top of glass. The Vertical joint of glass will be free from silicon. The total height of the system will be max. 600mm from Bottom of Base profile to Top of Handrail, . All top rail joints will be joined with accessories. MR- 12 |
| 59 | 12 mm cement plaster of mix : 1:6 (1 cement:6 fine sand). DSR 2023 13.4.2. |
| 60 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand). DSR 2023 13.5.2. |
| 61 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand). DSR 2023 13.16.1 |
| 62 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. DSR 2023 13.22. |
| 63 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre. DSR 2023 13.41.1. |
| 64 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm. DSR 2023 13.45.1. |
| 65 | Painting with synthetic enamel paint of approved brand and manufacture. Two or more coats on new work. DSR 2023 13.61.1. |
| 66 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface /finished wall to prepare the surface even and smooth complete. DSR 2023 13.80. |
| 67 | Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineerin-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.Cement concrete prepared with batch mixing machine. DSR 2023 16.43.1 |
| 68 | Extra for providing and mixing hardening compound of approved quality as per manufacturer’s specification in cement concrete.DSR 2023 16.44 |
| 69 | Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. DSR 2023 16.46.1 |
| 70 | Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, including cleaning the surface of ail dirt, scales, oil, grease and other foreign material etc. and lining out complete.New work (Two or more coats). DSR 2023 16.47.1. |
| 71 | Providing and fixing 1200 mm high heavy-duty rubber corner guard/column protector of approved make, manufactured from high-impact resistant rubber with yellow and black reflective safety markings, fixed to RCC columns/walls using suitable screws, anchor fasteners and adhesive as required, complete in all respects as per approved drawings and directions of the Engineer-in-Charge. MR- 19 |
| 72 | Flat Model, for 100 mm Expansion Joints having Flexible High Quality electrometric Inserts with short flanges with protection of Supporting Plate as per approved drawing. The Inserts should be Hard Wearing & temperature resistance (- 30 C to + 120 C Degree) suitable for Roof to Roof / Non Tower area location as per drawing and direction of Engineer in Charge. Expansion Joint covers/ Profile should have smooth Visible surface for easy Cleaning and also should be Antibacterial and physiologically safe.The seal should be resistant to oils, petrochemicals and should have weldable properties for seamless system. The side of the seal should have special grooves to house the adhesive, For a seamless system factory formed transitions pieces should be used during the installation of the cover system. The system should be installed with specially designed compression tool for better and even spread of adhesive. complete for all levels and heights. MR- 20 |
| 73 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. DSR 2023 22.3. |
| 74 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.After two days of proper curing applying a second coat of cement slurry using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge.Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge.With average thickness of 120mm and minimum thickness at khurra as 65 mm. DSR 2023 22.7.1. |
| 75 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @ 0.70 kg per sqm per coat DSR 2023 22.23.1. |
| 76 | For horizontal surface one coat @1.10 kg per sqm. DSR 2023 22.23.2. |
| 77 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.Frame Size - 50 x 100 mm. DSR 2023 26.86.3. |
| 78 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water /moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately). 30 mm Thick. DSR 2023 26.88.1. |
| 79 | PART-2 ElectricalPOINT & CONTROL WIRING IN PVC CONDUIT, DISTRIBUTION BOARDS ETC.: GENERAL NOTES.Required clearances from the concerned statutory authorities are in the scope of this work.Statutory fees paid will be reimbursed on production of original receipts in the name of Client. Please follow the GRIHA / Indian Green Building Council Norms for luminosus efficacy, lighting levels, illumination level etc.without extra cost.COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT.Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A. DSR E & M 2025 1.10.1. |
| 80 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. DSR E & M 2025 1.11. |
| 81 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. DSR E & M 2025 1.12. |
| 82 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. DSR E & M 2025 1.13. |
| 83 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (For Light Ckt Wiring Points/TV/ 6 Amp Light Plug). DSR E & M 2025 1.14.2. |
| 84 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire (For Light DB Basement /Stlit /Common area). DSR E & M 2025 1.7.7. |
| 85 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire. DSR E & M 2025 1.7.9. |
| 86 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire. DSR E & M 2025 1.7.11. |
| 87 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm. DSR E & M 2025 1.21.1. |
| 88 | 25 mm DSR E & M 2025 1.21.2. |
| 89 | 32 mm DSR E & M 2025 1.21.3. |
| 90 | 40 mm DSR E & M 2025 1.21.4. |
| 91 | 50 mm DSR E & M 2025 1.21.5. |
| 92 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch. DSR E & M 2025 1.24.1. |
| 93 | 2 way 5/6 amps switch. DSR E & M 2025 1.24.2. |
| 94 | 15/16 amp switch. DSR E & M 2025 1.24.3. |
| 95 | 3 pin 5/6 amp socket outlet. DSR E & M 2025 1.24.4. |
| 96 | 6 pin 15/16 amp socket outlet. DSR E & M 2025 1.24.5. |
| 97 | Telephone socket outlet. DSR E & M 2025 1.24.6. |
| 98 | TV antenna socket outlet. DSR E & M 2025 1.24.7. |
| 99 | Bell push. DSR E & M 2025 1.24.8. |
| 100 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. DSR E & M 2025 1.25 |
| 101 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. DSR E & M 2025 1.26. |
| 102 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm). DSR E & M 2025 1.27.1. |
| 103 | 3 Module (100mmX75mm). DSR E & M 2025 1.27.2. |
| 104 | 4 Module (125mmX75mm). DSR E & M 2025 1.27.3. |
| 105 | 6 Module (200mmX75mm). DSR E & M 2025 1.27.4. |
| 106 | 8 Module (125mmX125mm). DSR E & M 2025 1.27.5. |
| 107 | 12 Module (200mmX150mm). DSR E & M 2025 1.27.6. |
| 108 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch and 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). MR-01 E&M |
| 109 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. DSR E & M 2025 1.32. |
| 110 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). DSR E & M 2025 1.56. |
| 111 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.(For AC Units). DSR E & M 2025 1.57. |
| 112 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. DSR E & M 2025 1.38. |
| 113 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A . DSR E & M 2025 1.55.1. |
| 114 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. MR- 02 E&M |
| 115 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 1 Pair. DSR E & M 2025 1.18.1. |
| 116 | 2 Pair. DSR E & M 2025 1.18.2. |
| 117 | Supplying, installation, testing and commissioning of recess mounting, TPN TIER Per Phase Isolation , 415 volts, prewired, distribution board of sheet steel, dust protected, duly phosphatized and powder painted, inclusive of tinned copper insulated bus bar, common neutral link, earth bar, din bar for mounting MCBs, detachable gland/kNosck out plate and with built in loose wire box and superior make terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor up to the terminal connector/neutral link and ready for installation of following ways complete with connections, testing and commissioning etc. as required. DB's shall have a dedicated Earthing link fixed on insulated supports, which will be in addition to body earth link. DB shall be designed with provision for 8 module as incomer, 2 module as subincomer & SP MCBs as outgoing as per requirement. Inside each DB, a DB chart is to be fixed indicating all out going circuits. Notes:-1.MCBs shall be minimum 10 KA breaking capacity (Type –C). 2. Blanking Plates shall be included in scope of work.3. DB shall be of standard readymade type as per catalouge Nos from approved manufacturers as indicated in preferred makes of material.4. Wire way & cable end box also end & locking plates shall be provided.All Electrical component should have IS mark. 4 way, IP43, DD DB. DSR E & M 2025 2.5.1. |
| 118 | 8 way, IP43, DD DB. DSR E & M 2025 2.5.2. |
| 119 | 12 way, IP43, DD DB. DSR E & M 2025 2.5.3. |
| 120 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole. DSR E & M 2025 2.10.1. |
| 121 | Triple pole. DSR E & M 2025 2.10.4. |
| 122 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. DSR E & M 2025 2.11. |
| 123 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps. DSR E & M 2025 2.13.1. |
| 124 | 63 amps. DSR E & M 2025 2.13.2. |
| 125 | 100 amps. DSR E & M 2025 2.13.3. |
| 126 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps. DSR E & M 2025 2.15.1. |
| 127 | 40 amps. DSR E & M 2025 2.15.2. |
| 128 | Supplying and fixing TP sheet steel enclosure on surface/ recess along with 40/63 amps 415 volts \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required. DSR E & M 2025 2.17. |
| 129 | LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ). Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz,Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim.12 -15 watt. DSR E & M 2025 8.1.3. |
| 130 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm). 18- 22 Watt. DSR E & M 2025 8.9.1. |
| 131 | Supplying, Installation, Testing & Commissioning of mirror light integrated IP20 Batten Led fixture 600 mm 10 W +/- 1W with Surface Mounted with aluminium housing and Polycarbonate diffuser,minimum system efficacy of 100lm/W with P.F.>0.95 with THD<20% ,CCT6500 K,CRI 80,Surge Protection 2 Kv, IP20.The LED with Useful life of 50000 Hrs at L70. The Input voltage range shall be 150V to 270V including making suitable arrangement for fixing including connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC sheathed copper conductor etc as required complete as reqd. MR- 04 E&M |
| 132 | Supply, Installation, Testing and Commisioning of IP65 Bulkhead led fixture 10 W +/- 1 W Wall Mounted with minimum system lumen efficacy of 100 lm/W with Pressure Die Cast Aluminum housing, Polycarbonate Opal Diffuser and P.F.>0.95 with THD,including making suitable arrangement for fixing , connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC sheathed copper conductor complete as reqd. MR- 05 E&M |
| 133 | Supply, Installation, Testing and Commisioning of Wall Bracket led fixture 10 W +/- 1 W Wall Mounted with minimum system lumen efficacy of 100 lm/W and P.F.>0.95 with THD,including making suitable arrangement for fixing , connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC sheathed copper conductor complete as reqd. MR- 06 E&M |
| 134 | Supplying, installation, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor with day light dimming (lighting level shall be regulated as per availability of natural day light in an area along with occupancy detection.) having high performance, regulating programmable type, suitable for connected load upto 10Amp, for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required. DSR E & M 2025 7.2. |
| 135 | Supplying, Installation, Testing & Commissioning of 250 mm sweep fresh air ventilating fan with aerodynamically designed & balanced blades suitable for operation on 230 v single phase AC supply complete connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC sheathed copper conductor etc as required as reqd.with all accessories as required. MR- 07 E&M |
| 136 | Supply, Installation, Testing and Commissioning of following sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 Nos blades, 30 cm long down rod, 2 Nos caNospies, shackle kit, safety rope, copper winding, Power Factor Nost less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.1200 mm sweep. DSR E & M 2025 9.1.3. |
| 137 | PANEL FOR MAIN L.T. TOWER 3 BHK NEW: 1 Nos. 4000 Amp ACB Incomer Manually operated horizontal drawout type Air Circuit Breaker microprocessor based releases for O/C,S/C & earth fault protection with instantaneous. (50 KA). Bus Coupler Amp 4 pole with indicating lamps.INSTRUMENTS: 2 No. Multifunction Meter with CT's with LCD Display. 2 Set of phase indicating lights (RYB) with protection SP MCB's. (one set for each incoming breaker). 2 Set breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker). 2 Set trip circuit healthy indicating lamp.BUSBARS: 5000 Amp FP Aluminium busbars with coloured heat shrinkable sleeve . (Busbar density considered shall not be more than : 1A/Sqmm for Copper & 0.7A/Sqmm for Aluminium. Outgoings & Incomings:-All outgoings except space for spare's shall be provided with the followings accessories :- ON/OFF/TRIP indicating lamps. Multifunction meter (A.V,kW, kWH, KVA, KVAR, Hz) with communication ports for BMS and CT's CL-1 of suitable ratio. Nos. 1600 Amp 3P Manually operated horizontal drawout type MCCB microprocessor based releases for O/C,S/C & earth fault protection with instantaneous. (36 KA). 10 Nos. 630Amp FP Manually operated horizontal drawout type Moduler Circuit Breaker microprocessor based releases for O/C,S/C & earth fault protection with instantaneous. (36 KA). 2 Nos. 630Amp FP Manually operated horizontal drawout type Moduler Circuit Breaker microprocessor based releases for O/C,S/C & earth fault protection with instantaneous. (36 KA). 4 Nos. 100Amp FP Manually operated horizontal drawout type Moduler Circuit Breaker microprocessor based releases for O/C,S/C & earth fault protection with instantaneous. (36 KA). MR- 09 E&M |
| 138 | EMERGENCY PANEL: 2 Nos. 400ACB Incomer Manually operated horizontal drawout type mccb microprocessor based releases for O/C,S/C & earth fault protection with instantaneous. (50 KA). 400 Amp ATS 4 Pole.INSTRUMENTS: 2 No. Multifunction Meter with CT's with LCD Display. 2 Set of phase indicating lights (RYB) with protection SP MCB's. (one set for each incoming breaker). 2 Set breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker). 2 Set trip circuit healthy indicating lamp.BUSBARS: 500 Amp FP Aluminium busbars with coloured heat shrinkable sleeve . (Busbar density considered shall not be more than : 1A/Sqmm for Copper & 0.7A/Sqmm for Aluminium.OUTGOINGS:- All outgoings except space for spare's shall be provided with the followings accessories :- ON/OFF/TRIP indicating lamps. Multifunction meter (A.V,kW, kWH, KVA, KVAR, Hz) with communication ports for BMS and CT's CL-1 of suitable ratio. 4 Nos. 100 Amp FP Manually operated horizontal drawout type MCCB microprocessor based releases for O/C,S/C & earth fault protection with instantaneous. (25 KA).5 Nos. 63 Amp FP Manually operated horizontal drawout type microprocessor based releases for O/C,S/C & earth fault protection with instantaneous. (25 KA). MR- 20 E&M |
| 139 | PANEL as above for PLUMBING: INCOMING:- 1 Nos. 160 Amp Four Pole Moulded Case Circuit Breaker of 16 KA (Ics = Icu upto 433 volt) breaking Capacity with Thermal Magnetic release for O/L & S/C protection and neutral link complete with extended Rotary Mechanism and Spreader Link Set. INSTRUMENTS:- Multifunction meter (A.V,kW, kWH, KVA, KVAR, Hz) with communication ports for BMS and CT's CL-1 of suitable ratio. 1 Set of phase indicating lights (RYB) with protection SP MCB's. ON/OFF/TRIP indicating lamps. BUSBARS:- 200 Amp FP Aluminium busbars with coloured heat shrinkable sleeve. (Busbar density considered shall not be more than : 1A/Sqmm for Copper & 0.7A/Sqmm for Aluminium. OUTGOINGS:- All outgoings except space for spare's shall be provided with the followings accessories :- ON/OFF/TRIP indicating lamps. Multifunction meter (A.V,kW, kWH, KVA, KVAR, Hz) with communication ports for BMS and CT's CL-1 of suitable ratio.63 Amp TP&N MCB,10 KA - 2 Nos.40 Amp TP&N MCB,10 KA - 2 Nos. MR- 21 E&M |
| 140 | PANEL as above for EV CHARGING: INCOMING:- 1 Nos. 100 Amp Four Pole Moulded Case Circuit Breaker of 16 KA (Ics = Icu upto 433 volt) breaking Capacity with Thermal Magnetic release for O/L & S/C protection and neutral link complete with extended Rotary Mechanism and Spreader Link Set. INSTRUMENTS:- Multifunction meter (A.V,kW, kWH, KVA, KVAR, Hz) with communication ports for BMS and CT's CL-1 of suitable ratio. 1 Set of phase indicating lights (RYB) with protection SP MCB's. ON/OFF/TRIP indicating lamps. BUSBARS:- 150 Amp FP Aluminium busbars with coloured heat shrinkable sleeve. (Busbar density considered shall not be more than : 1A/Sqmm for Copper & 0.7A/Sqmm for Aluminium. OUTGOINGS:- All outgoings except space for spare's shall be provided with the followings accessories :- ON/OFF/TRIP indicating lamps. Multifunction meter (A.V,kW, kWH, KVA, KVAR, Hz) with communication ports for BMS and CT's CL-1 of suitable ratio.8 Nos. 63/100 Amp Four Pole Moulded Case Circuit Breaker of 16 KA breaking Capacity with Thermal Magnetic release for O/L & S/C protection and neutral link complete with extended Rotary Mechanism and Spreader Link Set. MR- 21 E&M |
| 141 | PANEL as above for EXTERNAL LIGHTING: INCOMING:- 1 Nos. 100 Amp Four Pole Moulded Case Circuit Breaker of 16 KA (Ics = Icu upto 433 volt) breaking Capacity with Thermal Magnetic release for O/L & S/C protection and neutral link complete with extended Rotary Mechanism and Spreader Link Set. INSTRUMENTS:- Multifunction meter (A.V,kW, kWH, KVA, KVAR, Hz) with communication ports for BMS and CT's CL-1 of suitable ratio. 1 Set of phase indicating lights (RYB) with protection SP MCB's. ON/OFF/TRIP indicating lamps. BUSBARS:- 150 Amp FP Aluminium busbars with coloured heat shrinkable sleeve. (Busbar density considered shall not be more than : 1A/Sqmm for Copper & 0.7A/Sqmm for Aluminium. OUTGOINGS:- All outgoings except space for spare's shall be provided with the followings accessories :- ON/OFF/TRIP indicating lamps. Multifunction meter (A.V,kW, kWH, KVA, KVAR, Hz) with communication ports for BMS and CT's CL-1 of suitable ratio. c) 63 A 4 Pole MCB complete with interconnections as required. - 06 nos.d) Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as reqd 3 output (1output per phase) and suitable for three phase supply. MR- 21 E&M |
| 142 | Supply, Installation, testing and commissioning of HYBRID APFC Panel, 3 phase 4 wire, 415 V, 50 Hz AC System for Ambient temperature -5°C to +40°C of following capacity with passive solution of 60%capacity and active solution of 40% capacity,3Phase 4 wire Hybrid Power Factor Correction Solution (with arrangment for neutral current balance) to achieve >0.99 lag and TDDI/THDV values within IEEE recommended limits.APFC should be designed as per recommended limits.APFC should be designed as per IS 16636 Or IEC 61921. The active section and passive section shall work in sync to give optimized output. The degree of protection of passive section should be IP 42, and of active section should be minimum IP 21.The switching device for APFC passive section should be through capacitor duty contactor and for the active compensation system shall be IGBT based with 3 level topology having 12 IGBT in inverter circuit. The active compensation system should filter harmonics from 2nd to 50th individual harmonic order and shall be selectable for the entire range. The active compensation system should have feature to improve PF correction and harmonic filtration having response time < 100 Micro second. The hybrid panel shall be indoor type floor mounted free standing totally enclosed, extensible, fabricated in compartmentalised designed made of CRCA sheet steel of 2.0mm thick for framework & covers, 3 mm thick for gland plate i/c cleaning & finishing complete with 9 tank process for powder coated of approved shade ( RAL 7032-Siemens gray or as approved by Engineer-in-Charge), having front section (switch gear and control accessories) and rear section (capacitor and reactor), front and rear access, having suitable current carrying capacity, extensible TPN Aluminium alloy bus bar of high conductivity, DMC/SMC bus bar supports,bottom base channel of MS Section, fabrication shall be done in transportable section, entire panel shall have common copper earth bar of minimum size of 25mm x 5mm with 2 nos. earth studs, the earth terminals provided on the body of capacitor bank shall also be bonded to the main capacitor panel earth bus with 2 nos. 8 SWG or 6 SWG GI earth wires/ equivalent size of copper conductor cable, forced ventilation for maintaining temperature rise not more than 5°C from ambient, interconnections, connections with 14% detuned reactor and heavy duty 525 V ISI marked Impregnated MPP(Metalized Polypropylene) Capacitor (IS 13340 Part -1 & 2) APFC Panel shall be in compliance with IS :16636 & CPWD Specifications etc. as per below details. ion as per approved by Engineering in charge. 400 KVAR. DSR E & M 2025 25.2.4. |
| 143 | DISTRIBUTION PANEL ( FOR SEB METERING) TOWERS: - Designing, fabricating, transporting, unloading, storing, fixing in position, testing and commissioning the following sheet steel cubicle type panels fabricated from 14 guage thick CRCA sheet, dust and vermin proof, indoor type MV Panels with hinged lockable doors fabricated from 2mm thick CRCA sheet, suitable for 415V, 3 phase 4 wire 50Hz AC supply with rear / bottom access for cable alley and with segregated bus-bar chamber and including supplying and fixing following switchgears, meters and accessories, inter-connections, bonding to earth, bottom base channel of MS. Entire panel shall have a common earth busbar at rear with 2 nos earth stud cable alleys, cable gland plates powder coated painting of approved shade after antirust treatment (with min seven tanks ) and marking as specified. Switch boards complete as per schematic diagram: Colour: Gray Powder Coated, as per approved sample. Incomer:- 1 No 400 A, 50kA, 4P Manually Draw Out ACB, microprocessor based, with overload, short circuit & earth fault releases with communication ports for RS 485 connectivity. Metering and Indications:- 1 No. Digital Multifunction meters with basic parameters like frequency, KW, KVA, KVAR, etc. shall be suitable for BMS function with Rs485 Port for Communication, complete with CTs and Protection MCB. RYB Phase Indication Lamps and ON/OFF LED Indicating Lamps with 2 Amp. SP MCB for protection. Busbar:- TPN aluminum bus bars of minimum of 500 Amps capacity with heat shrinkable colored sleeves and I/C DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. Outgoing Breakers:- 20 Nos 63Amp 4P MCB with 1 no Energy meter (Dual Type ). MR- 22 E&M |
| 144 | Supply and fixing auomatic type street light cubical control panel painted with anticorrosive alkaly and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, Isolating switch , metering instrument and instruments box with CT etc. complete in all respects.40A TPN. 807 SOR 2018 (RA) |
| 145 | Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Bus Trunking for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required.2500 amps 50KA SC for 1 sec. DSR E & M 2025 3.13.9. |
| 146 | Supply, handling, testing and commissioning of following sizes of 1.1 KV grade XLPE core insulated, extruded PVC inner sheath, armoured / unarmoured extruded outer sheath FRLS PVC, Copper / Aluminium conductor cables as per IS 7098 Part I ammended upto date. All complete as required and as per final instruction as given by E.I.C / Consultants.3.5 c x 240 sqmm Aluminium conductor. MR- 10 E&M |
| 147 | 3.5 c x 185 sqmm Aluminium conductor. MR- 11 E&M |
| 148 | 3.5 c x 95 sqmm Aluminium conductor. MR- 14 E&M |
| 149 | 3.5 c x 50 sqmm Aluminium conductor. MR- 16 E&M |
| 150 | 3.5 c x 35 sqmm Aluminium conductor. MR- 17 E&M |
| 151 | 4 c x16 sqmm Aluminium conductor. MR- 18 E&M |
| 152 | 4 c x16 sqmm copper conductor. MR- 19 E&M |
| 153 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm. DSR E & M 2025 10.1.1. |
| 154 | Above 35 sq. mm and upto 95 sq. mm. DSR E & M 2025 10.1.2. |
| 155 | Above 95 sq. mm and upto 185 sq. mm. DSR E & M 2025 10.1.3. |
| 156 | Above 185 sq. mm and upto 400 sq. mm. DSR E & M 2025 10.1.4. |
| 157 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm. DSR E & M 2025 10.2.1. |
| 158 | Above 35 sq. mm and upto 95 sq. mm. DSR E & M 2025 10.2.2. |
| 159 | Above 95 sq. mm and upto 185 sq. mm. DSR E & M 2025 10.2.3. |
| 160 | Above 185 sq. mm and upto 400 sq. mm. DSR E & M 2025 10.2.4. |
| 161 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm. DSR E & M 2025 10.5.1. |
| 162 | Above 35 sq. mm and upto 95 sq. mm. DSR E & M 2025 10.5.2. |
| 163 | Above 95 sq. mm and upto 185 sq. mm. DSR E & M 2025 10.5.3. |
| 164 | Above 185 sq. mm and upto 400 sq. mm. DSR E & M 2025 10.5.4. |
| 165 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm. DSR E & M 2025 10.6.1. |
| 166 | Above 35 sq. mm and upto 95 sq. mm. DSR E & M 2025 10.6.2. |
| 167 | Above 95 sq. mm and upto 185 sq. mm. DSR E & M 2025 10.6.3. |
| 168 | Above 185 sq. mm and upto 400 sq. mm. DSR E & M 2025 10.6.4. |
| 169 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle). DSR E & M 2025 10.7.1. |
| 170 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp). DSR E & M 2025 10.7.2. |
| 171 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp). DSR E & M 2025 10.7.3. |
| 172 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp). DSR E & M 2025 10.7.4. |
| 173 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle). DSR E & M 2025 10.8.1. |
| 174 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp). DSR E & M 2025 10.8.2. |
| 175 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp). DSR E & M 2025 10.8.3. |
| 176 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp). DSR E & M 2025 10.8.4. |
| 177 | Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.. DSR E & M 2025 10.9. |
| 178 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 35 sq. mm (32mm). DSR E & M 2025 11.1.21. |
| 179 | 3½ X 50 sq. mm (35mm). DSR E & M 2025 11.1.22. |
| 180 | 3½ X 95 sq. mm (45mm). DSR E & M 2025 11.1.24. |
| 181 | 3½ X 185 sq. mm (57mm). DSR E & M 2025 11.1.27. |
| 182 | 3½ X 240 sq. mm (62mm). DSR E & M 2025 11.1.29. |
| 183 | 4 X 16 sq. mm (28mm). DSR E & M 2025 11.1.33. |
| 184 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width X 50 mm depth X 1.6 mm thickness. DSR E & M 2025 4.6.1. |
| 185 | 150 mm width X 50 mm depth X 1.6 mm thickness. DSR E & M 2025 4.6.2. |
| 186 | 225 mm width X 50 mm depth X 1.6 mm thickness. DSR E & M 2025 4.6.3. |
| 187 | 300 mm width X 50 mm depth X 1.6 mm thickness. DSR E & M 2025 4.6.4. |
| 188 | 600 mm width X 62.5 mm depth X 2.0 mm thickness. DSR E & M 2025 4.6.11. |
| 189 | 900 mm width X 62.5 mm depth X 2.0 mm thickness. DSR E & M 2025 4.6.13. |
| 190 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (Galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.l. suspenders including G.l. bolts & nuts, etc. as required.100 mm width X 50 mm depth X 1.6 mm thickness. DSR E & M 2025 4.7.1. |
| 191 | 150 mm width X 50 mm depth X 1.6 mm thickness. DSR E & M 2025 4.7.2. |
| 192 | 225 mm width X 50 mm depth X 1.6 mm thickness. DSR E & M 2025 4.7.3. |
| 193 | 300 mm width X 50 mm depth X 1.6 mm thickness. DSR E & M 2025 4.7.4. |
| 194 | 600 mm width X 62.5 mm depth X 2.0 mm thickness. DSR E & M 2025 4.7.11. |
| 195 | 900 mm width X 62.5 mm depth X 2.0 mm thickness. DSR E & M 2025 4.7.13. |
| 196 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (Galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.l. suspenders including G.l. bolts & nuts, etc. as required.100 mm width X 50 mm depth X 1.6 mm thickness. DSR E & M 2025 4.8.1. |
| 197 | 150 mm width X 50 mm depth X 1.6 mm thickness. DSR E & M 2025 4.8.2. |
| 198 | 225 mm width X 50 mm depth X 1.6 mm thickness. DSR E & M 2025 4.8.3. |
| 199 | 300 mm width X 50 mm depth X 1.6 mm thickness. DSR E & M 2025 4.8.4. |
| 200 | 600 mm width X 62.5 mm depth X 2.0 mm thickness. DSR E & M 2025 4.8.11. |
| 201 | 900 mm width X 62.5 mm depth X 2.0 mm thickness. DSR E & M 2025 4.8.13. |
| 202 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal). DSR E & M 2025 15.16.1. |
| 203 | 90 mm dia (OD-90 mm & ID-76 mm nominal). DSR E & M 2025 15.16.2. |
| 204 | 120 mm dia (OD-120 mm & ID-103 mm nominal). DSR E & M 2025 15.16.3. |
| 205 | 160 mm dia (OD-160 mm & ID-135 mm nominal). DSR E & M 2025 15.16.4. |
| 206 | 200 mm dia (OD-200 mm & ID-175 mm nominal). DSR E & M 2025 15.16.5. |
| 207 | Supply, erection and commissioning of 2-pole structure for terminating 11 KV O.H. supply from supply company as per specifications and drawing. The 2-pole structure shall comprise of:- a) MS tubular swaged pole 11 mtrs high (410SP 24) (as per latest relevant BS standard)or as per Indian std., in cement concrete foundation 1:3:6 (1 cement : 3 coarse sand : 6 graded aggregate 40mm nominal size) including excavation and refilling etc. as required. The rate shall be inclusive of painting with 2 coats of aluminium paint (on red oxide). The portion of pole under the ground shall be provided with 2 coats of bituminous paint -2 Nos. b) Steel sections, channels angles, flats, clamps, GI nuts, bolts and required hardware etc of different sizes for cross arms, bracings, supports etc. for pole GODO etc. including anticlimbing barbed wires (conforming to BS Standard) having 4 points barbs spaced 75 ±12mm apart. All steel structure shall be given 2 coats of red oxide primer and 2 finishing coats of aluminium paint as required as per drawings and direction of Engineer-in-charge -Lot. c) Supply, installation, testing and commissioning of 11 KV class disc/pin/support insulators complete with clamps and fixing hard disc/pin/support insulators complete with clamps and fixing hard wares etc. complete as required as per drawings and direction of Engineer-in-charge -Lot. d) Supply, installation, testing and commissioning of 11 KV station class thyrite type lightning arrestors complete with mounting arrangement (on all phases) -1 Set. e) Supply, installation, testing and commissioning of drop out -lock out (DOLO) fuse, gang operating device (Air Break Switch) with pad locking arrangement (operating rod to be supported properly), complete with operating handle and locking arrangement -1 Set. f) Supply, installation, testing and commissioning of GI stay set complete with 20mm dia 1.8 M long stay rod with 450 x 450 x 7.5 mm anchor plate with thimbles, stay clamps, 7/4.00 mm dia GI stay wire, turn buckle (20mm x 600mm) strain insulator bow tightner in cement concrete 1:3:6 foundation as excavation and refilling -1 Sets. 2-pole structure as described above. MR- 23 E&M |
| 208 | Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of cubicle type 11 kV metering panel fabricated out of 14 SWG CRCA sheet steel, free standing floor readable dust and vermin proof with arrangement for sealing the covers and doors, re-inforcement of suitable size angle iron, channels, T sections of flats wherever necessary. Cable gland plate shall be provided on bottom of metering panel. Panel shall be treated with allanti-corrosion process prior to powder coating.Approval shall be obtained from concerened Electricity Board for the shop drawings before fabrication. The metering panel shall comprise the following:- Trivector Meter of Secure make, accuracy class 0.5. 3 nos cast resin CT's of 5/1 amps CT ratio, 15VA burden and accuracy class 0.5. 1 no. 3 phase potential transformer of approved make by Electricity Board. Ratio 11000V/√3/110/√3. VA Burden 100VA. Class 0.5. The metering panel shall be complete with all interconnections etc. as above including calibration of instruments as per State Electricity Board. MR- 23 E&M |
| 209 | Supply & Testing of following 11 KV (E) grade multicore Aluminium conductor XLPE insulated cable, insulation screening with extruded semi conducting compound in combination with copper tape armoured cores laid up, inner sheath of PVC tape, galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS: 7098 (Part - II) and complete with all latest amendments etc. complete as required.3 C x 240 sq mm. MR- 47 E&M |
| 210 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm. DSR E & M 2025 10.3.4. |
| 211 | Supplying and making indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :3 X180 sqmm . MR- 40 E&M |
| 212 | Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :240 sq. mm. DSR E & M 2025 11.2.26. |
| 213 | Supply, installation, testing and commissioning of following capacity (continuous loading) 11/0.433 KV Delta/Star,step down, 3 Phase, 50 Hz, Dyn 11 vector group, Cast Resin / VPI (vacuum pressure impregnated) Dry Type, copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better) AN (air natural) cooled transformer suitable for indoor applications with Offload Tap Changer/ On Load Tap Changer (OLTC) ( upto 500 KVA offload and above 500 KVA On Load Tap Changer) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, insulation class F (minimum), suitable for environment conditions class E4, suitable for fire behaviour class F1,climate class-C1, having cable end boxes on HV side suitable for 3x300 sqmm XLPE cable of 11 KV grade with necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers, bus trunking arrangement on LV side complete with all accessories and safety provisions as per relevant IS Code ,The transformer shall be provided with standard fittings/accessories as per relevant IS and mentioned below, protection alarm/trip protection, 3 nos. of Polymeric Zinc Oxide surge Arrestors on HV Side. Winding Temperature scanner (Digital) with alarm/Trip contacts with RTD Sensors per LV winding and space for mounting differential protection CT's in LV chamber with neutral brought out separately including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/HT Panel for safety tripping, complete as confirming to IS-2026 Part-11, i/c supplying and grouting of suitable M.S. Channel with all accessories ,complete in all respects as required at site as per CPWD specifications . Design ambient condition : a) air temperature 50 0C, b) Relative Humidity 90 % Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. The transformer should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. All testing shall as per relevant IS Code. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551/ NEMA Standard. Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Rating and terminal marking plates; c) Thermometer pocket with cap; d) Lifting lugs for the complete transformer as well as for core and winding assembly; e) Bi-directional flat rollers (for transformers above 200 kVA); f) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); g) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. fortransformers up to 200 kVA; h) Bird guard; i) Jacking pads (for transformer above 1 600 kVA); j) Name Rating & Diagram Plate. k) Monogram Plate.i) Additional neutral separately brought out on bushing for earthing. Level 3 . 1000 KVA (losses at 50% loading < 2790watt, losses at 100% loading < 7700watt) . DSR E & M 2025 24.27.24. |
| 214 | Supplying, Installation, Testing & Commissioning of Unit Rate ‘Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings: (A) Diesel Engine: Tourbocharged Diesel engine 4 stroke water cooled,multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 0C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications. (B) Engine mounted Instrument Panel fitted with and having digital dis Plate for following:(i) Start-stop switch with key, (ii) Water temperature indication, (iii) Lubrication oil pressure indication, (iv) Lubrication oil temperature indication, (v) Batery charging indication and Voltage indication, (vi) RPM indication, (vii) Over speed indication, (viii) Low lubricantion Oil trip indication, (ix) Engine Running Hours indication, (x) Fuel Level.(C) Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation. (D) Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. (E) FUEL TANK: Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. (F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor. (G) Starting System: 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set. (H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications.(I) AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following: 1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip. 2. Auto/Manual/Test/Off selector switch 3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay). 4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering 5. Energy analyser unit to indicate current, Voltage( L N & L_L), kW, kVA (Phase & Total), Frequency, KWH, PF. 6. LED Indicating lamps for load on mains and load on set 7. Fuse/ MCB for instruments 8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment. 9.Main supply failure monitor 10.Supply failure timer 11.Restoration timer 12.Control unit with three impulse automatic engine start/stop and failure to start lockout. 13. Impulse counter with locking and reset facility. 14.ON/OFF/Control circuit switch with indicator 15.Audio/Video annunciation for (i)High water temperature (ii)Low lubricating oil pressure (iii)Engine over speed (iv)Engine fails to start (v)Full load/maximum load warning 16.Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories 17. Maintenance notification based on Engine Run Hour & due date. 18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring. 500 KVA . DSR E & M 2025 29.1.15. |
| 215 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.. DSR E & M 2025 5.6 |
| 216 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.. DSR E & M 2025 5.1. |
| 217 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.. DSR E & M 2025 5.14. |
| 218 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.. DSR E & M 2025 5.16. |
| 219 | Providing and fixing earth bus of 1metre long 50 mm X 6 mm GI strip with 8 Nos tapping holes mounted on insulators & enclosed in IP 42 metal enclosurewith all accessories etc. as required. MR- 18 E&M |
| 220 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.. DSR E & M 2025 6.1. |
| 221 | Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.. DSR E & M 2025 6.2. |
| 222 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.. DSR E & M 2025 6.3. |
| 223 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.. DSR E & M 2025 5.4. |
| 224 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.. DSR E & M 2025 5.11. |
| 225 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.. DSR E & M 2025 5.15. |
| 226 | Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run). DSR E & M 2025 6.9. |
| 227 | Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run). DSR E & M 2025 6.1. |
| 228 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.. DSR E & M 2025 6.12. |
| 229 | Providing and fixing MV danger notice plate of 200mm x 150mm made of mild steel, atleast 2 mm thick, and vitreos enamelled white on both sides and with iscription in single red colour on front side as required. DSR E & M 2025 2.21. |
| 230 | Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.. DSR E & M 2025 2.22. |
| 231 | Supply and erection of shock restoration chart in glass frame. MR- 48 E&M |
| 232 | Supply & Erection of mild steel bucket stand suitable for 6 Nos. fire buckets,(but without bucket) including the cost of welding and painting of complete stand will one coat of red oxide and 2 coats of approved paint of red colour with all labour and material required to complete the job in all respect up to the entire Satisfaction engineer in charge of the work (size 6'x4' made of GI pipe 32mm dia).. MR- 19 E&M |
| 233 | Providing and fixing of insulated robber matting suitable for 11 KV each installation 1 M x 2 M x 12 mm thick (IS code 15652-40091) as per specification complete and as per directions of Engineer-in-charge. MR- 20 E&M |
| 234 | Supply and fixing of First Aid box as approved by St. John Ambulance Brigade / Indian red Cross conforming to IS 2217 - 1963. MR- 21 E&M |
| 235 | Providing pair of duly tested rubber hand gloves as per IS :340715 suitable for working on 15 kV. MR- 22 E&M |
| 236 | Supply, Installation, Testing and Commissioning of 800 mm long 11 W LED IP 65 Bollard , Housing made of extruded aluminium for excellent heat dissipation ,Weather-proof and rust-free luminaire with pure polyester powder coating,Symmetric glare-free light distribution with a polycarbonate diffuser,High-efficacy LEDs for optimum energy consumption,Potted driver and accessories pre-wired up to terminal block, having base plate with holes for direct mounting complete with all accessories including preparation of foundation, fixing, connection etc.complete as per requirement at site. Lumen Efficacy of LED>110Lm/W @ 4000 K color temperature ,PF ≥0.95, THD ≤10%,Input Voltage Range 140-280 V, 3 KV Inbuilt Surge Protection,50,000 Hrs LED life with L70 criteria.. MR- 23 E&M |
| 237 | Supply, Installation, Testing and Commissioning of 45 W LED Postop Dust and waterproof with IP66 made up of Aluminium diecast housing duly powder coated with pure grey polyester powder,Polycarbonate fresnel/street optic lens that reduces glare,Uniform and wide light distribution with lens/diffuser,Metal clad PCBs,High performing integral driver.luminare should be dry sky certified.Efficacy of LED>100Lm/W @ 5700 K color temperature ,PF ≥0.95, THD ≤10%,Input Voltage Range 140-280 V, 3 KV Inbuilt Surge Protection complete as per requirement at site.. MR- 24 E&M |
| 238 | Supply, Installation, Testing and Commisioning of 40 W LED street Light luminaire, cradle mounted, Al Pressure Die cast Housing having minimum system lumen efficacy of 110 lm/W with minimum system lumen output of 4400 lumens. The luminaire shall have IP66 protection with Beam angle of 60 degree, CCT of 5700K and CRI 80. The LED shall be compliant with Useful L70 life of >50000 Hrs.Driver efficiency should be 85%, THD0.95 in input voltage range of 140V to 300V (nominal rated voltage – 240V) with 5 KV internal surge protection and 10KV External protection. MR- 25 E&M |
| 239 | Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1 :5: 1 O of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge. 6 Metre Long pole with top dia 75 mm and bottom dia 150 mm with base plate of size 275 x 275 x 16 mm. MR- 26 E&M |
| 240 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.90 mm dia (OD-90 mm & ID-76 mm nominal). DSR E & M 2025 15.15.2. |
| 241 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm). DSR E & M 2025 11.1.32. |
| 242 | Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site:-(b) SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 200mm x 140mm x 95mm with hinged water tight cover with locking arrangement. MR- 27 E&M |
| 243 | Fabrication, supply, installation, testing & commissioning of outdoor type compartmentalized feeder pillar tapered (hut type) made out of 2mm thick CRCA sheet having separate cable and bus bar alley double door arrangement with two leaf door on front side and single door with double leaf on rear side with locking arrangement, having 100 amp TPN Aluminum bus bar of full length with base frame made out of 50x50x6mm thick angle iron having 300 mm legs duly erection in ground with construction of cement concrete complete with connection and interconnection with copper conductor PVC insulated cables / insulated copper conductor strip of appropriate size and terminals blocks (on outgoing) including supplying and fixing following switch gears & accessories there in powder coating, labeling, earthing etc. complete as required . a) 100Amps, 415V, 20 KA, TPN MCCB with operating handle (Incomer) = 1 No. b) 100 Amps. 415V, 3 phase AC, TP power contactor = 1 No. c) 63 A 4 Pole MCB complete with interconnections as required. - 10 nos. d) Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as reqd 3 output (1output per phase) and suitable for three phase supply. 4 nos 4 pole 32 amp Isolator. MR- 22B E&M |
| 244 | Supply, installation, testing and commissioning including vaccumiazation and nitrogen testing of following nominal sizes of soft/hard drawn copper refrigrant piping for VRV/VRF system complete with fittings with suitable adjustable ring type hanger supports , jointing / brazing including accessories , insulated with XPLE class o tubular insulation/with class o closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for suction and liquid lines , all accessories as per specifications etc. as required:12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation. DSR E & M 2025 31.14.3. |
| 245 | Supplying, Installation, Testing and commissioning of rigid UPVC drain Piping of size 25 mm dia with elbows, T- joints, sockets duly insulated with nitrile rubber insulation with adequate supports as per specifications and instructions of Engineer‐in charge i/c Charges for the work of brick and surface cutting / chiseling for the purpose of recessed PVC drain /copper pipe and making the wall in good condition by cement plaster etc as per site requirement including all raw material. MR- 28 E&M |
| 246 | Supply and fixing of 2.5 sq mm 4 core electrical cable 1.1KV grade flexible multistand with PVC conduit pipe 25 mm with accessories and fittings for installation of Split AC units as per site requirement.. DSR E & M 2025 1.17.13. |
| 247 | Providing, fixing, testing and commissioning of AMCA Certified (For Air and Sound Performance) tube / vane axial flow fan of different capacity as mentioned below in standard M.S. construction. Entire fan model & AMCA Seal shall appear in technical submittal of fan. All the fans are synthetic enamelled painted/hot dip galvanized with minimum 220 GSM Zinc Coating and complete with bird screen at inlet. The electric motor coupler shall be squirrel cage induction motor (IE-3 type) confirming to IS - 325-IP - 55 with class `H' insulation. Motor shall be of high temperature resistance \\"Class H Smoke Spill\\" 250° C for 2 hrs. Fan shall be TUV / CE Certified for high temperature. Fan shall be EN 12101-3 Certified high temperature. Motor should be VFD rated. Fan efficiency should not be less than 70 %. Noise level should not more than 80 dB @ 3 mtr distance when measured in hemispherical reverberant room conditions, for normal (non-fire) conditions, and not more than 85 dB @ 3mtr distance for fire conditions. Fans should be as per specification and drawings. Make: Kruger / Greenheck / Systemair.Motor make shall be same as mentioned on the fire certificate. 30,000 CFM @ 20 mm WC, normal conditions. MR- 41 E&M |
| 248 | 30,000 CFM @ 20 mm WC, fire conditions. MR- 42 E&M |
| 249 | Providing, fixing, testing and commissioning of Jet Fan which shall be provided with Dual Speed smoke spill motor with class \\"H\\" insulation for smoke extraction. Motor shall be suitable for operation on 415±10% volts, 50Hz, 3 phase AC power supply and capable to withstand 250 deg C temperature for a minimum duration of 2 hours. The Impeller of jet fan shall be Airfoil design with High efficiency blades. Fans shall be supplied with 2D silencer on both sides of the fan for Quite operation. Fan shall be AMCA Certified for Air and Sound Performance.The fan shall be CE/UL Certified for smoke control and exhaust applications as per EN 12101-3.Make: Kruger / Greenheck / SystemairBasement - 355 mm dia but not limited as per CFD analysis requirement. MR- 43 E&M |
| 250 | Computional fluid dynamic report for basement ventilation area, to analyse fan performance and placement, jet fans direction, along with analysis for visibility, carbon monoxide concentration, hot air temperature pockets in case of fire / smoke, and in non-fire conditions.Basement - 355 mm dia but not limited as per CFD analysis requirement. MR- 44 E&M |
| 251 | Supply, Installation, testing and commissioning of online, continuous monitoring of CO and radicals concentration in ambient air, measuring range: 0-300 ppm CO with electro-chemical galvanic (Gel electrolyte) technology, sensor should be UL2075 certified, response time t90 < 30 sec, with anti-sleep feature, capable of providing multiple threshold to identify normal mode, invisible smoke mode and fire mode. It should provide both analog output and digital communication via RS485 serial interface with Modbus RTU. It should have maintenance free period of more than 5 years, with life expentancy of more than 10 years. It should be uniquely addressable and suitable for connection in digital communication bus. Enclosure should have minimum fire retardant UL94: V0 rated with IP65 protection. Sensor cell should be plug-in, field replaceable, CE certified. It Should confirm to EMC- Directive 2014/30/EU.Make: SmartSensor / Siemens / HoneywellBasement + Stilt. DSR E & M 2025 42.11.11. |
| 252 | Supply, installation, testing and commissioning of Direct drive Tube Axial fans complete with Hot dipped Galvanised Steel Casing with spun flanges, adjustable pitch die cast aluminium impeller (Hub and Aerofoil blades) and IE3 motors. Casing position shall be as per the job requirement and shall be marked on the fan assembly.The complete fan assembly with its casing, impeller and motor ( not only motor or one of the item ) shall be sourced from one manufacturer. Fan mut be AMCA certifeid for Air & sound both13,500 CFM, S.P 25 mm WG. MR- 45 E&M |
| 253 | Combined Intelligent Control Panel with Fan starter, based on PLC design: Supply, installation, testing and commissioning of combined single panel with PLC modules, with self diagnostic feature of overload, cable heating, over temperature, inbuilt smoke detection and Electricalwith MPCB feeders and starters/VFD for dual speed Impulse jet fans, MCCB feeders with starters for Exhaust and Fresh Air single speed fans controlled by CO sensorswith suitable rating MCCBs, metering Panel, Aluminium bus bars, PLC logic Controller with necessary control wiring. Designing, fabricating, transporting, unloading, storing, fixing in position, testing and commissioning the following sheet steel cubicle type panels fabricated from 14 guage thick CRCA sheet, dust and vermin proof, indoor type PLC Panel with hinged lockable doors fabricated from 2mm thick CRCA sheet consisting of the following:-Incommer: 01Nos. 250 Amp Four Pole Moulded Case Circuit Breaker of 36 KA (Ics = Icu upto 433 volt) breaking Capacity with Thermal Magnetic release for O/L & S/C protection and neutral link complete with extended Rotary Mechanism and Spreader Link Set. Outgoing Feeders: Panel should equipped with over voltage, over current, phase protection, short circuit protection with motor starter based on DOL / Star - Delta for the followings:- For Impulse Jet Fans with suitable rating MPCBs as incommer. For Normal Mode tube / vane axial flow fan Fresh air fans with suitable rating MPCBs as incommer For Emergency / Fire Mode Exhaust tube / vane axial flow fans with suitable rating MCBs/ MPCCBs as incommer. Control system should based on programmable logic controller (PLC) with RS485 serial interface over ModBus RTU open protocol digital communication, capable of configuring multiple threshold for each sensor to identify and trigger normal ventilation, fire mode etc. It should work in closed loop, feedback mode with sensors, with auxiliary power supply to the sensor transmitters. It should be easily integrated with BMS (from Master PLC Module) providing all parameter values including fan status, sensor values, threshold status, fire command etc. It should accept and offer command to & from fire alarm system. Programmable to run and control fan (Jet Fans, Axial Fans) operation in normal, early fire, ventilation and fire mode based on sensor values or fire alarm signal or BMS signal or Manual operation. Configurable to control fan operation of any zone based on trigger of sensor of any same or other zone. It should have closed feedback signals for fan status, fan error etc. It should have overvoltage, over current, phase protection features. Fan should be operable in Manual / Auto fan mode. Panel should be equipped with emergency stop mushroom type push button for emergency stop condition. Panel should equipped with over voltage, over current, phase protection, short circuit protection with motor starter based on DOL / Star - Delta. Bus bar should be hot sleeved with suitable rating. Cable entries provided from top. With provision of minimum 45 nos jet fans but not limited as per CFD analysis requirement , 50 co sensors and 16 exhaust fans. MR- 46 E&M |
| 254 | Supply,Erection, Testing and Commosioning of the following MCCBs / MCBs in manufacturer\\"s sheet steel enclosures for MCBs, and suitable 16SWG enclosure for MCCBs with provision for cable entry boxes, with indoor and ourdoor application as specifed, fixed on the wall including all interconnections and accessories, and suitable 16SWG enclosure for MCCBs with provision for cable entry boxes,, fixed on the wall including all interconnections and accessories.Enclosure and MCCB GA drawing to be submitted for client approval before procurement. 32 A TPN MCB with Sheet Steel Enclosure. DSR E & M 2025 2.1.1. |
| 255 | 63 A TPN MCCB with Sheet Steel Enclosure. DSR E & M 2025 2.1.2. |
| 256 | Supply, laying, testing and commissioning of 1100 Volt gradeXLPE insulated copper conductor armoured cables conforming to IS:7098 (Part-1) including the cost of Lugs and gland, providing required gap between adjacent cables (minimum one cable dia.) and including the cost of providing identification tags etc. complete as per specification, as required.2.5 sqmm 6-core copper armoured cables (for jet fans). DSR E & M 2025 1.17.15. |
| 257 | 10 sq mm 3-core Copper Conductor, armoured power cable (For tube / vane axial flow fan of different capacity). DSR E & M 2025 1.17.28. |
| 258 | 6 sq mm 3-core Copper Conductor, armoured power cable (For tube / vane axial flow fan of different capacity). DSR E & M 2025 1.17.30. |
| 259 | Supply, laying, testing and commissioning of 1100 Volt grade PVC insulated Copper conductor cables including the cost of Lugs and gland, providing required gap between adjacent cables (minimum one cable dia.) and including the cost of providing identification tags etc. complete as per specification, as required.1.5 sq mm 3 core, shielded twisted control cable. DSR E & M 2025 1.17.3. |
| 260 | Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications Non return gravity dampers for exhaust fans, suitable for withstanding fan velocity & pressure, with smooth movement. DSR E & M 2025 30.12.1.2. |
| 261 | Supplying, fabricating, installing and testing of fire retardant nonporous double layer flexible connection constructed of fire resistant material For Ventilation units / Axial flow fans as per the drawings. DSR E & M 2025 30.12.2.2. |
| 262 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.Two Loop Panel.. DSR E & M 2025 28.2.1.2. |
| 263 | Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.. DSR E & M 2025 28.2.2. |
| 264 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.. DSR E & M 2025 28.2.4. |
| 265 | Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.. DSR E & M 2025 28.2.9. |
| 266 | Supplying, installation, testing & commissioning of addressable fire control module complete as required.. DSR E & M 2025 28.2.10. |
| 267 | Supplying, installation, testing & commissioning of addressable manual call point complete as required.. DSR E & M 2025 28.2.14. |
| 268 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.. DSR E & M 2025 28.2.15. |
| 269 | Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.. DSR E & M 2025 28.5.1. |
| 270 | Design, Composition, Supply & Installation of Led emergency light Material: Aluminium box+PMMA board Size: 360*200mm Features: Overcharge protection Light source: 3W led lights Light color: White led Voltage: AC90-260V 50/60Hz, AC110V~60Hz, AC220V~50Hz Battery:Ni-Cd1.2V Duration time: 90Mins or 3Hours Charging time: 24hour Automatically Power switch Finish: Double-side side printing. MR- 29 E&M |
| 271 | Supply, installation, testing & commissioning of 5 MP Dome camera , ONVIF profile S , G& T ,UL , CE , FCC Certified ,1/2.7” Progressive Scan CMOS ,2.7 mm to 13.5 mm motorized varifocal lens , Quad stream with each stream support H.265 compression simultaneously ,min illumination : Color 0.05lux @ F1.2(AGC ON) ; B/W 0 lux @ IR ON , Shutter speed : 1 / 5s ~ 1 / 100,000 s ,WDR , Compression : H.265/H.265+/H.264/H.264+ .SD card support upto 256GB , Alarm trigger - 1 input / 1 output , frame rate : Main stream should support 25 fps@5MP ,Video analytics : Customer Flow staistics, Cross COunt, Heat Map, Human & Vehicle Detection, Pedestrian Intrusion Detection & Line cross Detection. Queue length detection, Regional population statistics, SOD-Stationaary Object Detection. , In built IR LED , IR Distance upto 45 meters , IP 66 ,IK10,POE.Audio -1 input/1 output complete etc. as required.. DSR E & M 2025 40.6.2. |
| 272 | Supply, installation, testing and commissioning of 5 MP Bullet camera ,ONVIF profile S,G & T. UL , CE , FCC,BIS Certified,OEM defined MAC address,1/2.7” Progressive Scan CMOS ,3.6 mm motorized varifocal lens , Quad stream Each stram support H.265 compression simultaneously ,min illumination : Color 0.05lux @ F1.2(AGC ON) ; B/W 0 lux @ IR ON , Shutter speed : 1 / 5s ~ 1 / 100,000 s , WDR , Compression : H.265/H.265+/H.264/H.264+ .SD card support upto 256GB , frame rate : Main stream should support 25/30 fps@5MP, Built in Mic, Video analytics : Customer Flow staistics, Heat Map, Human & Vehicle Detection, Pedestrian Intrusion Detection & Line cross Detection. Queue length detection Regional population statistics, SOD-Stationaary Object Detection, Motion Detection, Tempring Detection, Rare Sound Detection, License Plate Detection. Defog. Protocols:- TCP/IP, HTTP, DHCP, DNS, DDNS, RTP/RTSP, SMTP, NTP, UPnP, SNMP, HTTPS, FTP, P2P, UDP,PPPoE, Bonjour. In built IR LED , IR Distance upto 30 meters , IP 66 , POE complete etc. as required. DSR E & M 2025 40.8.2. |
| 273 | Supply, installation, testing and commissioning of 32 channel NVR , ONVIF compliant , recording bandwidth 640 Mbps , output interface 1 HDMI (up to 4K), 1 VGA , Alarm in/out :16ch in / 4ch out , 1 X RJ45 ethernet , iOS smartphone support , 4 HDD support , each HDD slot support upto 8 TB HDD , 1x3.0 USB for backup /upgrade , 2x 2.0 USB for mouse .Edge analytics of poposed cameras must be integrated with NVR . Artificial Intelligence Support having face recognition with compatible deep learning supported cameras, AIFace registered quantity upto 10,000 ,A.I maximum captured quantity 200,000. UL,CE,FCC certified complete etc. as required. DSR E & M 2025 40.11.2. |
| 274 | Supply, installation, testing & commissioning of 8TB Surviellance Hard Disk complete etc. as required. DSR E & M 2025 40.12.3. |
| 275 | Supply, installation, testing & commissioning of Full HD 55\\" LED Professional Display Panel having 350 NITS and above brightness, complete as required. MR- 31 E&M |
| 276 | Supply, installation, testing & commissioning of Workstation PC: Intel(R) Core(TM) i7-3770 Processor (8M Cache, up to 3.90 GHz); RAM: 8GB (1x8GB) NonECC DDR3 1600MHz ; Keyboard: 12 function keys; Chassis: Tower/Workstation; DVD: 8X Slimline DVD+/- RW, Data Only; Dual Graphics Card; Network interface card: Integrated Intel(R) 82579LM Gigabit1 Ethernet LAN 10/100/1000; Hard disk: 250GB, 7200 RPM 3.5\\" SATA 6Gb/s Hard Drive; Operating system: Windows 7 Professional 64 Bit or latest complete etc. as required. MR- 32 E&M |
| 277 | Supply, Installation, Testing & Commissioning of 24 Port POE+ Access Switches with switching capaticy of 128 Gbps, forwarding performance 92 Mpps, having 24 x 10/100/1000BASE-T PoE-plus(RJ45) with minimum PoE budget of 370W, with 4 x 10G SFP+ uplink ports. Should Non Blocking architecture , 16K MAC address. Should have Static Routing ,RIP,VRRP, OSPF from day 1,Should support ISSU from day 1 ,Should support stacking with min 12 members in a stack, Neighbor discovery, system logging, Telnet, SSH, SNMP, Network Time Protocol (NTP), IPv6 features from day 1 , MTBF Min 198000 Hr complete etc. as required.. MR- 33 E&M |
| 278 | Supply, installation, testing & commissioning of armoured 6 core Singlemode OS2 (9/125 Micro), Corrugated ECCS Armoured, HDPE (UV) Sheathing, Theoxtropic gel filled OFC cable with 2 Nos steel music wire embedded in side sheathing as strength member for switch connectivity. Cable should be ROHS compliant and as per IEC60749-1 with product warranty of 3 years.. MR- 37 E&M |
| 279 | Supply, installation, testing & commissioning of 24F SM loaded LIU with LC adaptor plates, pigtel cables, Spilce tray, cable holder and 4 Nos of cable entry exist point with rubber gurment along with the LIU, Powder Coaded 1.2mm steel sheet metal, 1U etc complete as required. LIU should be in accordance with YD/T 778-2006 Optical Distribution Frame & YD/T 1272.1-2003 Optical Fiber Connector Part 1: Type LC and should have 3 years of product warranty.. MR- 35 E&M |
| 280 | Supply, installation, testing & commissioning of LC-LC singlemode OS2 (9/125) duplex, LSZH fiber patch cord for LIU to switch connectivity. Patch Cord should have aramid yarn as strenght member with 1000 time mating cycle. MR- 36 E&M |
| 281 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. 1 run of cable. DSR E & M 2025 39.17.1. |
| 282 | 2 run of cable. DSR E & M 2025 39.17.2. |
| 283 | 4 run of cable. DSR E & M 2025 39.17.4. |
| 284 | Providing and fixing of following sizes of PVC Flexibale Conduits suitable for various applications, halogen free, oil and petrol resistant, flame retardant, self extiguishing, high compressive strength and good wearing properties along with connectors complete with conduit gland & all accessories required.. MR- 38 E&M |
| 285 | Supplying, Installation, Testing & Commissioning of 13 passenger (680 Kg ) MRL lift having contract speed of 1.00 MPS serving different floors in the lift shaft and having barrier free requirements as per Appendix-VII of CPWD General Specifications for Electrical Works ( Part-III-Lifts & Escalators), 2003 and as per detailed specifications enclosed as under :- Speed - 1.5 MPS, Floors to be served - Basement + Stlit + 16 stories, Stops & Opening -18 on same side, Machine: Gearless machine with permanent magnet synchronous motor., Controller - Modular control microprocessor system combined with variable frequency and variable voltage system which can be located in door column at the top floor, Control - Variable frequency with closed loop vector control., Operation - Automatic, microprocessor based, duplex collective selective with / without attendant, Power - 415 V, 3 Phase, 50 Hz, AC , 4 wire system, Door Operation -Variable speed with close loop control., Type of doors (With Vision Panels), Car Entrance - Centre opening power operated horizontal sliding doors in stainless steel hairline finish, Landing doors - Stainless steel in hairline finish with infrared door protection device., Clear Opening of Doors - 800 mm ( W) x 2000 mm ( H), Position of Machinery - To be placed directly above hoist way., Flooring - Vinyl Tile., Lighting - Diffused Lighting in car, Signals :- Car operating panel in stainless steel, digital up down indicator, emergency light and alarm., Other Features -, Battery Operated Emergency Light with Rechargeable Battery., Battery Operated Emergency Alarm with Rechargeable Battery, Adjustable Guide Shoes Micro Movement L.E.D. Based Buttons, System Capable of withstanding (+) 10% to (- )10% variation in supply voltage fluctuations, Hands free press and speak intercom, Steel items such as machine beams, door frames sill angles, fascia plates, spring buffers, Full height infrared safety curtain with 74 intersecting beams, Car platform constructed out of cold rolled grain oriented formed sheets of steel, Fire man switch at main lobby, Car false ceiling in stainless steel in mirror finish with concealed CFL lights, Pit Ladder, Motor tested for 180 starts per hour, Automatic rescue device to automatically bring the elevator to nearest landing in case of power failure with SMF battery backup of 30 minutes. There shall be an automatic phase reversal correction device which will automatically align the supply phases in case of phase reversal. Mechnical Rescue divice also need to be provided., Digital lift announcement system shall be provided in car only to give an audio visual confirmation of elevator arrival. However the visual indicators shall also be provided at each floor to indicate car position, TRACTION SHALL BE BY MEANS OF FLAT POLYURETHANE COATED STEEL BELTS, Complete in all respect including providing & fixing guide rails, minor building works, scaffolding, putting into operation & final testing etc. as reqd.Travel - 60 Meters ( approx.). MR- 22D E&M |
| 286 | Supply, Installation, Testing and Commissioning of on grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along withsupplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. Solar cable shall be Flexible Tinned Copper Conductor Single Core( 2 Runs for +ve and -ve) Multistrand, Cross Linked, Zero Halogen Low Smoke Insulation and CrossLinked Low Smoke Sheathing ,Heat Resistant upto 120⁰C and UV Resistant Solar Cables between solar modules Array junction box and PCD unit. 17.1 (DSR E&M 2025) |
| 287 | Input Voltage (VAC) 1-Ph 230V or 3-Ph 400V Output Voltage (VAC) 7.4kW, AC Max. Output Power Rating (kW) 4.3\\" TFT Color Touch Screen Display RFID / Mobile App based User Authentication PWM as per IEC 61851-1 / IS 17017 Charger and Vehicle Communication LAN / 4G / WiFi Charger Interface Indoor / Outdoor Place of Installation IP55 Ingress Protection. 18.1.1 (DSR E&M 2025) |
| 288 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia. DSR E & M 2025 27.7.1. |
| 289 | 32 mm dia. DSR E & M 2025 27.7.2. |
| 290 | 40 mm dia. DSR E & M 2025 27.7.3. |
| 291 | 50 mm dia. DSR E & M 2025 27.7.4. |
| 292 | 65 mm dia. DSR E & M 2025 27.7.5. |
| 293 | 80 mm dia. DSR E & M 2025 27.7.6. |
| 294 | 100 mm dia. DSR E & M 2025 27.7.7. |
| 295 | 150 mm dia. DSR E & M 2025 27.7.8. |
| 296 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel. DSR E & M 2025 27.9.2. |
| 297 | Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel. DSR E & M 2025 27.10.2. |
| 298 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :80 mm dia. DSR E & M 2025 27.11.4. |
| 299 | 100 mm dia. DSR E & M 2025 27.11.5. |
| 300 | 150 mm dia. DSR E & M 2025 27.11.6. |
| 301 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150mm dia. DSR E & M 2025 27.14.7. |
| 302 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304). DSR E & M 2025 27.16.2. |
| 303 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m. DSR E & M 2025 27.17.1. |
| 304 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304). DSR E & M 2025 27.18.2. |
| 305 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way-100 mm dia M.S. Pipe. DSR E & M 2025 27.19.1. |
| 306 | 4 way - 150 mm dia M.S. Pipe. DSR E & M 2025 27.19.2. |
| 307 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :a) 25mm dia. DSR civil 2023 18.18.3. |
| 308 | Providing & fixing Gunmetal 25 mm dia. Air release valve. 18.59.1 civil 2023 |
| 309 | 150 mm nominal size square 100 mm diameter of the inner hinged round grating.a) 75 mm square size. 18.58.2.1 civil 2023 |
| 310 | Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Pendent Sprinkler . DSR E & M 2025 27.21.1. |
| 311 | Upright Sprinkler . DSR E & M 2025 27.21.2. |
| 312 | Horizontal side wall sprinkler . DSR E & M 2025 27.21.3. |
| 313 | Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required.150mm dia. DSR E & M 2025 27.23.2. |
| 314 | Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :150mm dia. DSR E & M 2025 27.24.3. |
| 315 | Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.. DSR E & M 2025 27.29. |
| 316 | Providing pressure gauges with isolation cocks and chrome plated copper pipes as hydrant station to read pressure from 0-10 kg/cm2 complete and of dial dia 100 mm MR -1 |
| 317 | Providing and fixing standard fireman's axe with heavy insulated rubber handle. MR -2 |
| 318 | Providing and fixing fire hose cabinet, fabricated from M.S. 'T' iron frame and 16 gauge M.S. sheet of fully welded construction with hinged double front shutters with locking arrangement and partially glazed with 4 mm thick glass, stove enameled fire red finished with \\"FIRE HOSE\\" written on front, suitable to house first aid fire hose reel fabricated as per drawing and approved sample.Size 2100x900x600mm deep.MR -3 |
| 319 | Providing and fixing light weight, water-proof fibre-glass reinforced plastic fire hose cabinet, with hinged single or double front glazed shutter with locking arrangement, stove enameled fire red finished with \\"FIRE HOSE\\" written on front, including necessary supports approximate size 760x610x255 mm (suitable to house two lengths of canvas hose with couplings, branch pipes, one fireman's axe, nozzle and hydrant outlet for external hydrants and terrace hydrant ) including fixing the cabinet by making suitable raised platform of brick masonry with bricks of class 75 and plaster etc, fabricated as per drawing and approved sample. MR -4 |
| 320 | Providing and fixing 25 mm dia inspecting & tetsting assembly with gunmetal isolation valves, gunmetal sight glass, 50 mmdia byepass vave and connected to 50 mm line drain MR -10 |
| 321 | Providing and fixing Carbon-di-oxide type fire extinguishers consisting of welded M.S. cylindrical body, internal discharge tube, discharge nozzle, suspension bracket, conforming to IS 2878, finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.a) Capacity 4.5 kg MR-5 |
| 322 | b) Capacity 22.5 Kg. (Trolley mounted) MR-7 |
| 323 | Providing and fixing Dry chemical powder type fire extinguishers consisting of welded M.S. cylindrical body, internal discharge tube, discharge nozzle, suspension bracket, conforming to IS 2171, finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.a) Capacity 5.0 kg MR-11 |
| 324 | Providing and fixing ABC Powder type fire extingushers consisting of welded M.S. cylindrical body, squeeze lever dischange valve fitted with pressure indicating guage internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 2171 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.a) Capacity 2 Kg. MR-7 |
| 325 | b) Capacity 5 Kg. MR-8 |
| 326 | Providing and fixing signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containingLumigen II as base chemical, covered under UV stablized coating and of appropriate size (Glo-lite or eq. Make) including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge. MR-9 |
| 327 | Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m.All kinds of soilPipes, cables etc. exceeding 80mm dia but not exceeding 300mm.. DSR 2023 2.10.1.2. |
| 328 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.. DSR 2023 12.22. |
| 329 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion.110 mm. DSR 2023 12.41.2. |
| 330 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.Coupler110 mm. DSR 2023 12.42.1.2. |
| 331 | Single tee with door110x110x110 mm. DSR 2023 12.42.3.2. |
| 332 | Single tee without door110x110x110 mm. DSR 2023 12.42.4.2. |
| 333 | Bend 87.5 degree110 mm Bend. DSR 2023 12.42.5.2. |
| 334 | Shoe (Plain)110 mm Shoe. DSR 2023 12.42.6.2. |
| 335 | Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm. DSR 2023 12.43.2. |
| 336 | Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. DSR 2023 17.1.1. |
| 337 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer.. DSR 2023 17.7A. |
| 338 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink without drain board610x510 mm bowl depth 200 mm. DSR 2023 17.10.2.1. |
| 339 | Providing and fixing CP Brass 32 mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge.. DSR 2023 17.22A. |
| 340 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality& make as approved by Engineer in charge.15 mm nominal dia. DSR 2023 17.22B. |
| 341 | Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.. DSR 2023 17.31. |
| 342 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.. DSR 2023 17.33. |
| 343 | Providing and fixing toilet paper holder :C.P. brass. DSR 2023 17.34.1. |
| 344 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :a) 100mm inlet & 100mm outlet.. DSR 2023 17.60.1.3. |
| 345 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.. DSR 2023 17.71. |
| 346 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.. DSR 2023 17.78. |
| 347 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work-Exposed on wall20 mm nominal dia pipes. DSR 2023 18.7.2. |
| 348 | 25 mm nominal dia pipes. DSR 2023 18.7.3. |
| 349 | 32 mm nominal dia pipes. DSR 2023 18.7.4. |
| 350 | 40 mm nominal dia pipes. DSR 2023 18.7.5. |
| 351 | 50 mm nominal dia pipes. DSR 2023 18.7.6. |
| 352 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc.15 mm nominal dia pipes. DSR 2023 18.8.1. |
| 353 | 20 mm nominal dia pipes. DSR 2023 18.8.2. |
| 354 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work25 mm nominal dia pipes. DSR 2023 18.9.3. |
| 355 | 65 mm nominal dia pipes. DSR 2023 18.9.7. |
| 356 | 80 mm nominal dia pipes. DSR 2023 18.9.8. |
| 357 | 100 mm nominal dia pipes. DSR 2023 18.9.9. |
| 358 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore. DSR 2023 18.17.1A. |
| 359 | 40 mm nominal bore. DSR 2023 18.17.3. |
| 360 | 50 mm nominal bore. DSR 2023 18.17.4. |
| 361 | 80 mm nominal bore. DSR 2023 18.17.6. |
| 362 | Providing and fixing unplasticised PVC connection pipe with brass unions.45 cm length15 mm nominal bore. DSR 2023 18.21.2.1. |
| 363 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :150 mm diameter. DSR 2023 18.22.2. |
| 364 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :100 mm diameter. DSR 2023 18.31.1. |
| 365 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of classdesignation 7.5. DSR 2023 18.32.1. |
| 366 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931a) 15 mm nominal bore. DSR 2023 18.49.1. |
| 367 | Providing and fixing C.P. brass long nose bib cock of approved qualityconforming to IS standards and weighing not less than 810 gms.15 mm nominal bore. DSR 2023 18.50.1. |
| 368 | Providing and fixing C.P. brass angle valve for basin mixer and geyserpoints of approved quality conforming to IS:893115 mm nominal bore. DSR 2023 18.53.1. |
| 369 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete200 mm. dia.. DSR 2023 19.1.3. |
| 370 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :200 mm. dia. Pipes. DSR 2023 19.3.3. |
| 371 | Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design180x150 mm size P typeWith Sewer bricks conforming to IS : 4885. DSR 2023 19.4.3.2. |
| 372 | Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :0.91 m deep with S.F.R.C. cover and frame (heavy duty,HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. DSR 2023 19.9.1.1. |
| 373 | Extra depth for circular type manhole 0.91m internal dia (at bottom)beyond 0.91 m to 1.67 mWith common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5. DSR 2023 19.10.1. |
| 374 | Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. DSR 2023 19.11.1.1. |
| 375 | Extra depth for circular type manhole 1.22 m internal dia (at bottom)beyond 1.68 m to 2.29 m :With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5. DSR 2023 19.12.1. |
| 376 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard designWith 20x20 mm square bar. DSR 2023 19.15.1. |
| 377 | Providing & fixing health faucet with flexible pipe of 1 metre length. (Plumbing MR- 01 |
| 378 | Providing & fixing S.S. Towel ring round with round flange. (Plumbing MR- 02 |
| 379 | Providing & fixing single lever mixer with swinging spout for sink.. (Plumbing MR- 03 |
| 380 | Providing & fixing S.S. Towel rail 600 mm long in bathing area.. (Plumbing MR- 04 |
| 381 | Providing & fixing S.S. Grating (floor drain/jali).. (Plumbing MR- 05 |
| 382 | Providing and fixing of 75X 63 mm dia floor drain complete in all respects.. (Plumbing MR- 05A. |
| 383 | Providing and fixing UPVC pipes complete with fittings including cutting and making good the walls etc.UPVC SWR Single socket pipe type-B 40 mm dia. (Plumbing MR- 016 |
| 384 | UPVC SWR Single socket pipe type-B 63 mm dia. (Plumbing MR- 06A. |
| 385 | UPVC SWR Single socket pipe type-B 110 mm dia. (Plumbing MR- 07 |
| 386 | UPVC SWR Single socket pipe type-B -160 mm dia. (Plumbing MR- 08 |
| 387 | Providing and fixing of multiple inlet 100 mm dia pvc height riser with 40 mm to 63 mm complete in all respects etc.. (Plumbing MR- 08A. |
| 388 | Pipe Clips40 mm dia . (Plumbing MR- 09 |
| 389 | 63 mm dia. (Plumbing MR- 09 |
| 390 | 110 mm dia Pipe - Clips. (Plumbing MR- 10 |
| 391 | 160 mm dia Pipe - Clips. (Plumbing MR- 11 |
| 392 | Stays & Clamps100 mm dia. (Plumbing MR- 13 |
| 393 | 160 mm dia. (Plumbing MR- 14 |
| 394 | Single tee with door110 mm dia. (Plumbing MR- 15 |
| 395 | 160 mm dia. (Plumbing MR- 16 |
| 396 | Single tee without door110 mm dia. (Plumbing MR- 17. |
| 397 | 160 mm dia. (Plumbing MR- 18 |
| 398 | Bend 87.5 degree40 mm dia. (Plumbing MR- 19 |
| 399 | 63 mm dia. (Plumbing MR- 19A |
| 400 | 110 mm dia. (Plumbing MR- 20 |
| 401 | 160 mm dia. (Plumbing MR- 21 |
| 402 | SUMP PUMP- at sump pits in basement & pump roomProviding & fixing fully submersible drain pump for drain water transfer from Drain Sump to equalization tank. The pump shall have complete CI construction, TEFC induction motor including , lifting arrangement for the pump, all necessary piping, valves, level controller, probes, cable etc. and other accessories as required Solid handling shall be 20 mm.Capacity 18 M3/Hr. (1W+1S) @ 10-15 Mtr head (Make-Kirloskar). (Plumbing MR- 22 |
| 403 | Providing, fixing, testing & Commissioning of Air release valve for tank filling pipe line25 mm dia. (Plumbing MR- 23 |
| 404 | Providing, fixing, testing & Commissioning of Pressure Reducing Valves in water down take pipes at required locations.50 mm dia. (Plumbing MR- 24 |
| 405 | 40 mm dia. (Plumbing MR- 25 |
| 406 | Domestic Water Pumping set (to supply water from Pump Room to OHTs)Supply, Installation, testing and commissioning of Variable drive package type skid mounted hydro pneumatic system comprising of:Vertical inline single/multistage centrifugal pumping set with stainless steel SS stage casing and SS impellers with stainless steel shaft, cast iron suction & discharge casing, connected to suitable capacity TEFC ventilated induction motor 2 pole, 2900rpm, suitable for 415+10% Volts, 3 phase, 50 Hz A.C. supply.Pressure vessel of non corrosive FRP composite construction lined with NSF and/or FDA listed material, like high density polyethylene with fully replaceable polyurethane. Air cell burst pressure of minimum of 5 times the vessel operating pressure and cycle tested for 2,50,000 cycles. No. and capacity of Pressure Vessel - 1 No. of suitable dia.Electrical Control Panel including provision for cyclic operation of pumps -Pump working sequence should change after every operation. Control panel with programmable logic controller (PLC) with inbuilt PID controller , digital display with fluorescent screen, one no. 3 ph, 415 ± 10%V, , overload relays and MCBs should conform to IEC 898-1995 standards Ammeter, voltmeter. All trip indications should blink in case of trip and panels should only be accessible through an access code.Electronic Pressure switches having maximum pressure and differential scale should confirming BS-6134 standards and IP-55 protection class.Complete set system to be mounted on a common MS base frame and shall follow following duty.The cost will include making necessary flanged suction and delivery headers in GI (C class) and butter fly valves and Non return valves, rubber bellow on suction and delivery.Motor to be of the same make as the pump.The pump shall be selected for performance at best efficiency point. However, the pump selection shall be suitable for performance with set point @ + 20% of the rated head. (Make-Kirloskar )Water Transfer Pumps (1 Nos: 1W+ 1S)Capacity : 25 Cum/hr. each pump capacity Head : 100 mtrs.. (Plumbing MR- 27 |
| 407 | Pressure Booster to supply from terrace to upper floorsProviding, installing, testing and commissining of Fixed hydropneumatic system mounted on a common base plate on cement concrete foundation comprising of Horizontal/vertical centrifugal pumping set with CI Base Suction Delivery, Stainless steel-304 impeller, Stainless steel-304 Stage casing, Stainless steel-316 shaft and mechanical seal, driven by TEFC induction motor suitable for 400/440 volts, 3 phase, 50 cycles AC supply with 100 mm dia pressure gauge with isolation cock, pressure Switches, sequence running cotroller, dry running Protection, Panel with other required protection, necessary power and control cabling from Panel to pumps & transmitter including required rating of MCB, one no M.S diaphragam tank 200 ltr or as per manufacturer calculation,complete in all respects including CC foundation of suitable size,Including Galvanized Iron suction and delivery headers and isolation/ control valves( ball valves/butterfly valves/ Non return valves etc as required)The entire Hydropneumatic system shall be Pump Manufacturer factory fitted and testedSet of Two Pumps (1 Working + 1 Assist)Capacity 24000 LPHHead 20 M.. (Plumbing MR- 28 |
| 408 | SITC of Motorized valve along with water level sensor and panel, PVC Ball valve (02 nos for suction & discharge and 01 nos for bypass) for Domestic overhead water tanks for various buildings65 mm dia. (Plumbing MR- 31 |
| 409 | Providing and fixing all instrumentation eg.level controllers indicator sensors, etc. for making the system complete. (Make :- Minilec / Ital / Technika / Ewas / Status / Technica) for Underground Water Storage Tank. (Plumbing MR- 32 |
| 410 | Providing and fixing 25 mm dia garden hydrant including gun metal gate valve with C.I. wheel of approved quality (screwed end) and required pipe etc. complete in all respects. (Plumbing MR- 33 |
| 411 | Providing and fixing Parking Suspended signage of size 1200 (L) x 300 (H) x 50 (thickness) lit sign suspended from ceiling/grid of approved make made up of Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa made from virgin homogeneous aluminium billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with 10 years warranty under normal working conditions. Sign is double sided 50 mm depth profile with media accomodation depth of 6 mm media of ACP acrylic upto 5 mm thickness can be pasted directly on frames or attched on frame with help of dual lock tape. Sign can be edge lite with help of edge lite led modules , lED of LUCOLED or equivalent make, fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. The rates are inclusive of all the material, media, lite, labour, carriage, fixing etc. all complete.. (Signages MR- 25 |
| 412 | Providing and fixing Flat number signage of size 300 (L) x 125 (H) x 12 (thickness) fixed on door/wall, non-lit signage made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa made from virgin homogeneous aluminium billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with 10 years warranty under normal working conditions. Sign is single sided with 1 aluminium profile click fitted on 2 plastic moulded endcaps. Sign is including all plastic injection moulded end caps black in shade which are directly press fitted, media can be flat bed UV printed on panels/ profiles. Panels fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. The rates are inclusive of all the material, media, lite, labour, carriage, fixing etc. all complete.. (Signages MR- 26 |
| 413 | Providing and fixing Door/wall fixed Room Identification non-lit Sign of size 300 (L) x 156 (H) x 12 (thickness) made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa made from virgin homogeneous aluminium billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with 10 years warranty under normal working conditions. Sign is single sided with 1 aluminium profile click fitted on 2 plastic moulded endcaps. Sign is including all plastic injection moulded end caps black in shade which are directly press fitted ,media can be flat bed UV printed on panels/ profiles. Panels fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. The rates are inclusive of all the material, media, lite, labour, carriage, fixing etc. all complete. |
| 414 | Providing and fixing non lit wall fixed Building Directory Sign of minimum size 1000 (L) x 1800 (H) x 15 (Thickness) or as per site requirement made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa made from virgin aluminium homogeneous billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with 10 years warranty under normal working conditions. Sign is single sided with aluminium side tracks and common click clips for panel fitting. Sign is including all plastic injection moulded clips black in shade which are slided in side tracks, media can be flat bed UV printed on panels/ profiles. Panels fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. The rates are inclusive of all the material, media, lite, labour, carriage, fixing etc. all complete.. (Signages MR- 28 |
| 415 | Providing and fixing non-lit wall fixed Floor directory sign of minimum size 500 (L) x 1000 (H) x 15 (Thickness) or as per site requirement made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa made from virgin aluminium homogeneous billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with 10 years warranty under normal working conditions. Sign is single sided with aluminium side tracks and common click clips for panel fitting. Sign is including all plastic injection moulded clips black in shade which are slided in side tracks, media can be flat bed UV printed on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. The rates are inclusive of all the material, media, lite, labour, carriage, fixing etc. all complete.. (Signages MR- 29 |
| 416 | Providing and fixing non-lit wall/Door fixed Shaft Signs of size 300 (L) x 93 (H) x 12 (thickness) made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa made from virgin homogeneous aluminium billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with 10 years warranty under normal working conditions.Sign is single sided with 1 aluminium profile click fitted on 2 plastic moulded endcaps. Sign is including all plastic injection moulded end caps black in shade which are directly press fitted, media can be flat bed UV printed on panels/ profiles. Panels fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. The rates are inclusive of all the material, media, lite, labour, carriage, fixing etc. all complete.. (Signages MR- 30 |
| 417 | Providing and fixing non-lit wall/Door fixed Staircase ID Sign of size 300 (L) x 93 (H) x 12 (Thickness) signs made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa made from virgin homogeneous aluminium billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with 10 years warranty under normal working conditions. Sign is single sided with 1 aluminium profile click fitted on 2 plastic moulded endcaps. Sign is including all plastic injection moulded end caps black in shade which are directly press fitted, media can be flat bed UV printed on panels/ profiles. Panels fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. The rates are inclusive of all the material, media, lite, labour, carriage, fixing etc. all complete.. (Signages MR- 31 |
| 418 | Providing and fixing non-lit wall fixed Cautionary Sign or Warning Sign of size 300 (L) x 93 (H) x 12 (Thickness) signs made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190MPa made from virgin homogeneous aluminium billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with 10 years warranty under normal working conditions. Sign is single sided with 1 aluminium profile click fitted on 2 plastic moulded endcaps. Sign is including all plastic injection moulded end caps black in shade which are directly press fitted, media can be flat bed UV printed on panels/ profiles. Panels fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. The rates are inclusive of all the material, media, lite, labour, carriage, fixing etc. all complete.. (Signages MR- 32 |
| 419 | Providing and fixing non-lit, wall/door fixed Washroom Sign of size 156 (L) x 156(H) x 12 (Thickness) signs made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa made from virgin homogeneous aluminium billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with 10 years warranty under normal working conditions.Sign is single sided with 1 aluminium profile click fitted on 2 plastic moulded endcaps. Sign is including all plastic injection moulded end caps black in shade which are directly press fitted, media can be flat bed UV printed on panels/ profiles. Panels fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. The rates are inclusive of all the material, media, lite, labour, carriage, fixing etc. all complete.. (Signages MR- 33 |
| 420 | Providing and fixing non-lit ceiling suspended Lobby sign of size 300 (L) x 156 (H) x 12 (Thickness) signs made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa made from virgin homogeneous aluminium billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with 10 years warranty under normal working conditions. Sign is single sided with 1 aluminium profile click fitted on 2 plastic moulded endcaps.Sign is including all plastic injection moulded end caps black in shade which are directly press fitted, media can be flat bed UV printed on panels/ profiles. Panels fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. The rates are inclusive of all the material, media, lite, labour, carriage, fixing etc. all complete.. (Signages MR- 34 |
| 421 | Providing and fixing non-lit door/wall fixed Lift Number Sign of size 200 (L) x 125 (W) x 12 (Thickness) made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa made from virgin homogeneous aluminium billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with 10 years warranty under normal working conditions. Sign is single sided with 1 aluminium profile click fitted on 2 plastic moulded endcaps. Sign is including all plastic injection moulded end caps black in shade which are directly press fitted, media can be flat bed UV printed on panels/ profiles. Panels fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. The rates are inclusive of all the material, media, lite, labour, carriage, fixing etc. all complete.. (Signages MR- 35 |
| 422 | Providing and fixing non-lit, wall fixed \\"Use Stairs in Case of Fire\\" sign of size 300 (L) x 250 (H) x 10 (Thickness) of approved make Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa Made from virgin homogeneous aluminium billet) with premium grade anodizing (Thickness 15-20 microns) as peinternational standards, with 10 years warranty under normal working conditions. Profile to form frame with overall depth of 10 mm with media of thickness upto 3mm & 2 mm thick acrylic/ACP . I-sign Fix profile with M.S zinc coated corners with grub screws. Installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. The rates are inclusive of all the material, media, lite, labour, carriage, fixing etc. all complete.. (Signages MR- 36 |
| 423 | Providing and fixing non-lit, wall fixed Fire extinguisher sign of size 300 (L) x 300 (H) x 10 (Thickness) approved make Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa Made from virgin homogeneous aluminium billet) with premium grade anodizing (Thickness 15-20 microns) as peinternational standards, with 10 years warranty under normal working conditions. Profile to form frame with overall depth of 10 mm with media of thickness upto 3mm & 2 mm thick acrylic/ACP . I-sign Fix profile of approved make with M.S zinc coated corners with grub screws. Installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. The rates are inclusive of all the material, media, lite, labour, carriage, fixing etc. all complete.. (Signages MR- 37 |
| 424 | Providing and fixing Emergency Exit sign of size 308 (L) X 213 (H) x 40 (Thickness) of approved make emergency exit sign- illuminated, surface mount (wall or ceiling) Dual sided made up of plastic material, battery backup of 3 hours (180 mins). Battery life of 300 cycles of charge & discharge Li-ion battery 3.7 Volt, 2200 mAh, Charge time of 24 hours. Input voltage 220-240 Volt A.C, 50/60 Hz. Viewing distance 30 meter, degree of protection IP20 (rating for protection against solid object up-to 12 mm) white light colour full back (white colour) 3 Watt LED illumination (without graphics). Test facility auto self test, and battery damage indication, Power AC ON & AC OFF mode (manual switch to change modes). Luminescence of >15 cd/m2,AC connection 0.75 sq-meter.Sign with 12 months warranty for electric circuit & 6 months warranty for battery. Sign provided with dual mounting arrangement of mounting on wall & ceiling both (with flat rigid support/base).Sign is including all connection wires as required & high tensile strength zinc coated self tapering screws (4 nos with screw wall plastic packing), installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. The rates are inclusive of all the material, media, lite, labour, carriage, fixing etc. all complete.. (Signages MR- 38 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender