Tender For Proposed Construction Of Auditorium Capacity 400 Person (Anawasiya Bhawan) At District - Mirzapur (U.P.)
Tender Value
6.25 Crore
Estimated cost
Bid Submission
25 Nov 2026
1 days left
EMD
12.50 Lakhs
Bank guarantee accepted
Document Fee
7714
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mirzapur → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Proposed Construction Of Auditorium Capacity 400 Person (Anawasiya Bhawan) At District - Mirzapur (U.P.)
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORK- |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. DSR- 2.8.1 |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. All kinds of soil. From 0.00 mt to 1.50 mt. DSR-2.6.1 |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. All kinds of soil. 1.50mt to 3.0 mt. DSR-2.6.1+2.26.1 |
| 5 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. DSR- 2.25 (a) |
| 6 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. DSR- 2.27 |
| 7 | Providing and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment and creating a chemical barrier under and around the column pits, wall trenche basement excavation top surface if plinth filling junction of wall and floor along the external per meter of binding expension joints surrounding of pipes and conduit etc. Complete (Plinth area of building at ground floor only shall be measured as per I.S. 6313 part II 1981). Aldrine emulsificable concentrate of any other approved material such as Hepthachlor or Chlordance will be used. The rate of application of chemical emulsion shall be as follows: I. Treatment for masonry and foundation 5 liters/sqm., II. Back fill in immediate contact with foundation 7.5 liters/sqm., III. Treatment of top surface of plinth filling 5 liters/sqm., IV. Treatment juction of soil along external per meter building 7.50 liters/sqm., V. Treatment of soil under apron along external perimeter 5 liters/sqm. as per PWD Deoria SOR, Page no. 17, New Item SI.No. 1 |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-lll) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) DSR-4.1.8 |
| 9 | Providing and laying in position cement concrete of 1:5:10 (1 cement : 5 coarse sand derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level. DSR- 4.1.10 |
| 10 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of E-i-c. With material conforming to Grade-II (Size range 53 mm to 0.075 mm) having CBR Value-25. DSR- 16.78.2 |
| 11 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. DSR- 16.79 |
| 12 | Providing and applying Separation Membrane of impermeable plastic sheeting 125 micron thick including all complete. DSR- 0323 |
| 13 | Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineerin- charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. Cement concrete prepared with batch mixing machine. DSR-16.43.1 |
| 14 | Brick work with common burnt clay (non modular) bricks of class -150 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) DSR- 6.1.1 |
| 15 | Brick work with common burnt clay (non modular) bricks of class -150 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) DSR- 6.1.2 |
| 16 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:All works upto plinth level. Concrete of M25 grade with minimum cement content of 330 kg /cum. DSR-5.33.1.1 |
| 17 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: All works above Plinth Lvl. Concrete of M25 grade with minimum cement content of 330 kg /cum. DSR-5.33.2.1 Column Above Plinth Lvl. |
| 18 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete in Thermo-Mechanically Treated bars of grade Fe-500D or more. DSR- 5.22.6 |
| 19 | Add for using extra cement in the items of design mix over and above the specified cement content therein. DSR- 5.35 |
| 20 | Centering and shuttering including stutting, propping etc. and removal of form. Foundation DSR- 5.9.1 |
| 21 | Centering and shuttering including stutting, propping etc. and removal of form. Slab DSR- 5.9.3 |
| 22 | Centering and shuttering including stutting, propping etc. and removal of form. Beam /Band DSR- 5.9.5 |
| 23 | Centering and shuttering including stutting, propping etc. and removal of form. Column DSR- 5.9.6 |
| 24 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) . DSR-5.11.1 |
| 25 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. DSR-4.13 |
| 26 | Brick work with common burnt clay bricks of Class-150 in super structure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:4 (1 cement : 4 coarse sand ) (Half Brick Wall) DSR-6.13.2 |
| 27 | Brick work with common burnt clay bricks of Class-150 in super structure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:6 ( 1 cement : 6 coarse sand ) DSR- 6.4.2 |
| 28 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strikeplate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B- Fixing with adjustable lugs with split end tail to each jamb. DSR-10.14.1.1 |
| 29 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. DSR- 9.48.1 |
| 30 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in- harge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (70 mm & above) x (40 mm & above) & both glazed and fly screen sash (256 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 metre). DSR- 9.147.A4.1 |
| 31 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary. Extra for cutting rebate in flush door shutters. DSR- 9.20.1 |
| 32 | Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory, all complete with 4.0 mm thick glass panes. DSR-10.30.1 |
| 33 | 12 mm thick cement plaster of mix 1:6 ( 1 cement & 6 course sand ) DSR- 13.4.2 |
| 34 | 15 mm thick cement plaster of mix 1:6 ( 1 cement & 6 course sand ) DSR-13.5.2 |
| 35 | 15 mm thick cement plaster of mix 1:4 ( 1 cement & 4 coarse sand ) DSR-13.5.1 |
| 36 | 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall. DSR-13.9.1 |
| 37 | 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall. DSR-13.10 |
| 38 | Making Grooves cutting 10 to 12 mm wide and 8 mm deep a in plaster. DSR- 5.30 |
| 39 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone ) finished with floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. 40 mm thick floor 20 mm nominal size stone aggregate. DSR-11.3.1 |
| 40 | Supply & Laying of 40 mm gauge over burnt brick ballast including all materials, labour and T&P etc. for proper completion of the work. DSR-0287 |
| 41 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. DSR- 11.41.2 |
| 42 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to 1.8. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc complete. Size of Tile 600x600 mm. DSR- 11.46.2 |
| 43 | Providing and fixing 18 mm thick Granite (gang saw cut) mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red. (Slab area above 0.50 Sq.M.) DSR- 8.2.2.2 |
| 44 | Providing and laying Ceramic glazed floor tiles of size 300 x 300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. DSR-11.37 |
| 45 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to 1S: 16622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. DSR- 8.31 |
| 46 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Light shade pigment using white cement DSR-11.20.1 |
| 47 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plasterd wall surface even and smooth surface. DSR-13.80 |
| 48 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. DSR -13.62.1 |
| 49 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre. DSR-13.41.1 |
| 50 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) DSR -13.47.1 |
| 51 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”: With average thickness of 120 mm and minimum thickness at khurra as 65 mm. DSR -22.7.1 |
| 52 | Providing & fixing oxidized M.S. sliding door bolts ISI marked with nuts and screws etc complete (300mm x 16mm). DSR-9.62.1 |
| 53 | Providing & fixing oxidized M.S. tower bolts ISI marked with nuts and screws etc complete (250mm x 10mm). DSR-9.63.1 |
| 54 | Providing & fixing oxidized M.S. Door Handle ISI marked with nuts and screws etc complete (125mm). DSR-9.66.1 |
| 55 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) DSR- 10.28 |
| 56 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. DSR- 9.121 |
| 57 | 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. DSR- 9.122.1 |
| 58 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using Gl slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to 1S: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. DSR-12.52.4 |
| 59 | Providing and fixing at all height wall panelling with phenol bonded Bamboo Mat board conforming to IS:13958-1994 including providing and fixing to frame work made of 50 mm x 50 mm hard wood plugs including cutting brick work and fixing in cement mortar and making good the wall etc. and also providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws all complete as per direction of Engineer-in-Charge. 12 mm thickness. DSR-26.6E.2 |
| 60 | INTERNAL / EXTERNAL PLUMBING & SEWERAGE WORK- |
| 61 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:- W.C. pan with ISI marked white solid plastic seat and lid_DSR_17.3.1 |
| 62 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests W.C. pan with ISI marked white solid plastic seat and lid_DSR_17.1.1 |
| 63 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap._DSR_17.7.4 |
| 64 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern_DSR_17.4.2 |
| 65 | Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge. 15mm nominal bore_DSR_17.16A |
| 66 | Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms._DSR_17.71 |
| 67 | Providing and fixing Toilet paper holder C.P. brass_DSR_17.34.1 |
| 68 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 110mm diameter_DSR_12.41.2 |
| 69 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete._DSR_12.22 |
| 70 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm_DSR_12.43.2 |
| 71 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams._DSR_12.44 |
| 72 | Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) around P.V.C /C.I. Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) 100 mm diameter_DSR_19.2.1 |
| 73 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. internal work -Exposed on wall 25mm dia nominal outer dia pipes_DSR_18.7.3 |
| 74 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. internal work -Exposed on wall 32mm dia nominal outer dia pipes_DSR_18.7.4 |
| 75 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 15mm dia nominal outer dia pipes_DSR_18.8.1 |
| 76 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 20mm dia nominal outer dia pipes_DSR_18.8.2 |
| 77 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 25mm dia nominal outer dia pipes_DSR_18.8.3 |
| 78 | Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore_DSR_18.51.1 |
| 79 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931- 15mm nominal bore_DSR_18.53.1 |
| 80 | Providing and fixing CP Brass 32mm/40mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge._DSR_17.22A |
| 81 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore_DSR_18.52.1 |
| 82 | Providing & fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge._DSR_18.53A |
| 83 | Providing and fixing gun metal gate valve with wheel of approved quality. 25mm dia nominal bore_DSR_18.17.1 |
| 84 | Providing and fixing gun metal gate valve with wheel of approved quality. 32mm dia nominal bore_DSR_18.17.2 |
| 85 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia._DSR_2.10.1.2 |
| 86 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150mm diameter_DSR_19.6.2 |
| 87 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 150 mm diameter S.W. pipe_DSR_19.3.2 |
| 88 | Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design: 150 x 100 mm. size P type With bricks of class M-150_DSR_19.4.2.2 |
| 89 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). bricks of class M-150 For Sewer Line Extra for depth for manholes:_DSR_19.7.1.1 |
| 90 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:(With 20x20mm square bar)_DSR_19.15.1 |
| 91 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof_DSR_18.77 |
| 92 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Shoe (Plain) 110mm shoe_DSR_12.42.6.2 |
| 93 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 100 mm dia_DSR_19.2.1 |
| 94 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm dia_DSR_12.41.2 |
| 95 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Coupler 110 mm_DSR_12.42.1.2 |
| 96 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Single tee with door 110x110x110 mm_DSR_12.42.3.2 |
| 97 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Single tee without door 110x110x110 mm_DSR_12.42.4.2 |
| 98 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5 degree 110mm bend_DSR_12.42.5.2 |
| 99 | Providing and fixing soil, waste and vent pipes : 75mm diameter : Centrifugally cast (spun) iron socketed pipe as per IS: 3989._DSR_17.35.2.2 |
| 100 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality Circular shape 450 mm internal diameter_DSR_19.19.1.3 |
| 101 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks Class-150_DSR_19.32.1 |
| 102 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality Circular shape 500 mm internal diameter._DSR_19.19.2.2 |
| 103 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5_DSR_18.33 |
| 104 | BORRING WORK- |
| 105 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. All Types of Soil. 350 mm dia_DSR 23.1.1.2 |
| 106 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 350 mm dia_DSR 23.2.1.2 |
| 107 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 300 mm dia_DSR 23.2.1.1 |
| 108 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia having minimum wall thickness 5.00 mm_DSR 23.10.2 |
| 109 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia_DSR-23.4.2 |
| 110 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia_DSR 23.11.3 |
| 111 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge._DSR 23.7 |
| 112 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. _DSR 23.8 |
| 113 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge._DSR 23.12 |
| 114 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 150 mm dia_DSR 23.13.2 |
| 115 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm dia_DSR 23.14.2 |
| 116 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I). 150 mm dia_DSR 23.15.2 |
| 117 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 80 mm dia nominal bore_DSR 18.12.8 |
| 118 | HORTICULTURE WORK- |
| 119 | Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts_[DSR-2.12] |
| 120 | Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure)._[DSR-2.1] |
| 121 | Supplying and stacking at site dump manure from approved source including carriage upto 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm._(DSR-2.4.3) |
| 122 | Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment)._(DSR-2.2) |
| 123 | Spreading of sludge, dump manure or/and good earth in required thickness (cost of sludge dump manure or/and good earth to be paid separately)._(DSR-2.8) |
| 124 | Carrigae of manure upto 10 K.M. _(DSR-1.1.3) |
| 125 | Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge._(DSR-2.9) |
| 126 | Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately)_[DSR-2.13] |
| 127 | Complete maintenance of the entire garden features having as per yard stick in the garden area i.e. lawn trees, shrubs, hedge, flower beds, foliages, creepers etc. including hoeing,weeding pruning replacement of plants, gap filling, watering, mowing of lawn, grass cutting by lawn mover and brush cutter , removal of garden waste, applying insecticide, pesticide & fertilizers(whenever required) top dressing of lawn with good earth and menure and maintenance of other garden related works as directed by office-in-charge (Cost of Good Earth, Manure, Fertilizer, Insecticide , Pesticide , lawn mover and brush cutter with fuel will be provided by the Department & other T & P material/articles shall be provided by the contractor.) Office accommodation. (1.25 Acres = One Mali) As per Per sqm/yard stick. (For One Year= 4.70 * 12)_(DSR-2.39.3) |
| 128 | Providing and displaying of Raphis Palm having ht. 75 cm to 90 cm with 15 to 18 equal suckers, well developed, full of fresh and healthy leaves from bottom to top in 35 cm PVC Pots/C.Pots & as per direction of the officer-in-charge._(DSR-3.70) |
| 129 | Providing and displaying of Seaforthia Palm having ht. 90 cm to 1.20 m with 6-8 suckers, well developed, fresh and healthy lush green leaves from bottom to top in 20 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge._(DSR-3.72) |
| 130 | Providing and displaying of Syngonium golden mounted on moss stick 90 cm ht., 3 to 4 s placed in each pot at equal distance, well developed with full of fresh & healthy leaves from bottom to top in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge._(DSR-3.80) |
| 131 | Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. well developed with fresh & healthy bushy in full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the officer-in-charge._(DSR-5.12) |
| 132 | Providing and Displaying Latania Rubra Palm well developed with fresh & healthy foliage 150 to 180 cm ht. with 6 to 7 leaves in big 35 cm Cement Pot as per direction of the officer-in-charge._(DSR-5.35) |
| 133 | Providing and Displaying Topiary of Ficus Panda well developed with fresh & healthy foliage with 3 to 4 Ball and 60 to 75 cm spread each Ball, 135 to 150 cm ht., in 35 cm Cement Tray /Cement Pot as per direction of theofficer-in-charge_(DSR-5.40) |
| 134 | Providing and stacking of Calliandra hybrida of height 75-90 cm. with 4-5 branches in bag of size 25 cm as per direction of the officer-in-charge._(DSR-8.6) |
| 135 | Providing and stacking of Cestrum nocturnum (Raat ki Rani) of height 60- 75 cm. with 4-5 branches in bag of size 25 cm as per direction of the officer-in-charge._(DSR-8.13) |
| 136 | INTERNAL ELECTRICAL WORK- |
| 137 | Wiring for Light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C_DSR (E&M)_1.10.3 |
| 138 | Wiring for Twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required._DSR (E&M)_1.11 |
| 139 | Wiring for Light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required_DSR (E&M)_1.12 |
| 140 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required 2 x 1.50 sqmm + 1 x 1.50 sqmm earth wire_DSR (E&M)_1.14.1 |
| 141 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required 2 x 2.50 sqmm + 1 x 2.50 sqmm earth wire_DSR (E&M)_1.14.2 |
| 142 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required 2 x 4.00 sqmm + 1 x 4.00 sqmm earth wire_DSR (E&M)_1.14.3 |
| 143 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required 2 x 6.00 sqmm + 1 x 6.00 sqmm earth wire_DSR (E&M)_1.14.4 |
| 144 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required 2 x 10.00 sqmm + 1 x 6.00 sqmm earth wire_DSR (E&M)_1.14.5 |
| 145 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required 4 x 10.00 sqmm + 2 x 6.00 sqmm earth wire_DSR (E&M)_1.14.10 |
| 146 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required 4 x 16.00 sqmm + 2 x 6.00 sqmm earth wire_DSR (E&M)_1.14.11 |
| 147 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required._DSR (E&M)_1.25 |
| 148 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required._DSR (E&M)_1.26 |
| 149 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required._DSR (E&M)_1.31 |
| 150 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required_DSR (E&M)_1.32 |
| 151 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required._DSR (E&M)_1.33 |
| 152 | Supply and fixing of call bell of approved make on board including making connection etc.complete in all respect._DSR (E&M)_1.38 |
| 153 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Up to Sweep 400 mm/300 mm_DSR (E&M)_1.50.1 |
| 154 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes._DSR (E&M)_1.51 |
| 155 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings)._DSR (E&M)_1.56 |
| 156 | Supplying & fixing suitable size Gl box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required._DSR (E&M)_1.57 |
| 157 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB /RCCB /Isolator) 12 way, Double Door_DSR (E&M)_2.3.3 |
| 158 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface / recess, complete with tinned copper bes bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), double door_DSR (E&M)_2.4.1 |
| 159 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface / recess, complete with tinned copper bes bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), double door_DSR (E&M)_2.4.2 |
| 160 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole_DSR (E&M)_2.10.1 |
| 161 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double Pole_DSR (E&M)_2.10.3 |
| 162 | Supplying and fixing Single pole Blaking plate in the Existing MCB DB Complete. as required._DSR (E&M)_2.11 |
| 163 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/recess, complete with testing and commissioning etc. as required. For 10 way Double Door SPN MCBDB_DSR (E&M)_2.23.3 |
| 164 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/recess, complete with testing and commissioning etc.as required For 4 way Double Door TPN MCBDB_DSR (E&M)_2.24.1 |
| 165 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required._DSR (E&M)_5.4 |
| 166 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)_DSR (E&M)_5.9 |
| 167 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS: 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise 75 °C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200 mm, Service value _>6.0 CM/Min/Watt,Air delivery 210 CM/Min_DSR (E&M)_9.1.3 |
| 168 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 35 sq. mm and upto 95 sq.mm_DSR (E&M)_10.1.2 |
| 169 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq.mm_DSR (E&M)_10.1.3 |
| 170 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 x 16 sq mm (28 mm)_DSR (E&M)_11.1.33 |
| 171 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 x 35 sq mm (32 mm)_DSR (E&M)_11.1.21 |
| 172 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 x 120 sq mm (45 mm)_DSR (E&M)_11.1.25 |
| 173 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm Dia_DSR (E&M)_1.21.1 |
| 174 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm Dia_DSR (E&M)_1.21.2 |
| 175 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm Dia_DSR (E&M)_1.21.3 |
| 176 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C. Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg 1 Run of cable_DSR (E&M)_39.17.1 |
| 177 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required._DSR (E&M)_1.19 |
| 178 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amp_DSR (E&M)_2.13.1 |
| 179 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amp_DSR (E&M)_2.13.2 |
| 180 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 amp_DSR (E&M)_2.13.3 |
| 181 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 amp_DSR (E&M)_2.12.1 |
| 182 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc Size - 16 sq. mm 4 core_DSR (E&M)_20.1.9 |
| 183 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc Size - 35 sq mm x 3.50 core_DSR (E&M)_20.1.11 |
| 184 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc Size - 50 sq mm x 3.50 core_DSR (E&M)_20.1.12 |
| 185 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc Size - 120 sq mm x 3.50 core_DSR (E&M)_20.1.15 |
| 186 | LED Down lighter (COB Type) (System lumen efficacy ≥ 105 < 120lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector. 12 - 15 watt_DSR (E&M)_8.4.3 |
| 187 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 18- 22 Watt_DSR (E&M)_8.9.1 |
| 188 | LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 36 watt_DSR (E&M)_8.7.4 |
| 189 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antenna socket outlet_DSR (E&M)_1.24.7 |
| 190 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required._DSR (E&M)_1.19 |
| 191 | Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. 24 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each copper port supporting 802.3at PoE+ min_DSR (E&M)_39.3.1 |
| 192 | Supplying Installation Testing and Commissioning of 2 MP IP IR Dome Camera having following specifications, type of lens and features etc :- Signal System: PAL/NTSC, Signal to Noise Ratio:>50 dB, Camera should display Camera title, Date & Time in live & recorded video2)Image Sensor: 1/2.8\\" or better progressive Scan CMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 3) Compression (Minimum):-Video:- H.265 or better, H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 4) Wide Dynamic Range:- WDR (120db or more) 5) Digital Noise Reduction:- DNR (3D) On/Off 6) Video Streaming & Frame Rates :- Triple streaming , configurable (Main stream: 2MP (1920 ×1080)@25/30 fps,Sub streams minimum: 720P@25/30 fps). 7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection 8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, syslog, video encryption, IP/MAC filtering, HTTPS, trusted upgrade, trusted boot. 9) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. |
| 193 | 10) Recording Management: Format SD, overwrite, storage management, video to NAS device 11) Alarm Trigger : Motion/tampering detection; audio detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast 13) System Capability: ONVIF, Camera shall support open source VMS 14) Ethernet: 1 RJ 45 10/100 Ethernet port 15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement. 16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source. 17) Power Requirement: 12VDC/24 VAC/PoE (802.3af)/ePoE 18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body 19) Operating Condition:- Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing) 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8 MBPS or better 22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS 2MP (@ 25/30fps@1080P (1920×1080)) IP IR Dome Camera with 2.8/ 3.6mm fixed lens._DSR (E&M)_40.1.1 |
| 194 | Supplying Installation Testing and Commissioning of 4MP IP IR Outdoor Bullet Camera having following spcifications and features etc :- 1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB,Camera should display Camera title, Date & Time in live & recorded video 2)Image Sensor: 1/2.8\\" or better progressive Scan CMOS get color image even at night Condition (Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 3) Compression (Minimum): Video:- H.265 or better, H.265, H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723, (4) Wide Dynamic Range:- WDR (120db or more) 5) Digital Noise Reduction:- DNR (3D) On/Off (6) Video Streaming & Frame Rates :-Triple streaming , configurable Main stream: 4MP (2560×1440)25/30fps Sub streams minimum: 720P@25/30 fps 7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection |
| 195 | 8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade 9) Onboard Storage: Camera should support built-in Micro SD/ SDHC/ SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 10) Recording Management: Format SD, overwrite, storage management, video to NAS device, 11) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 13) System Capability: ONVIF, Camera shall support open source VMS 14) Ethernet: 1 RJ 45 10/100 Ethernet port 15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/Out for External Mic. and Speakers as per site requirement. 16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source. 17) Power Requirement: 12VDC/24 VAC/PoE (802.3af)/ePoE 18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body 19) Operating Condition:- Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing) 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8 MBPS or better 22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS 4MP @ 25/30fps@1440P (2560 x 1440) Outdoor Bullet Camera with 2.8/ 3.6/6/8/12 mm fixed lens (as per site requirement)_DSR (E&M)_40.4.1 |
| 196 | Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having spcifications and features etc as mentioned below : 1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP camera or more and must be ONVIF with minimum support of 384 Mbps incoming Bandwidth. 2) NVR should support video compreesions : H.265 or better, H.264, MJPEG. 3) Must support 1 channel RCA Input, 2 channel RCA Output for Two-way Talk with G.711U/A, G.711u, PCM, G726 audio compressions. 4) Intelligent auto power on when power resumes after power outage. 5) Storage: It should support minimum 8 SATA Slots with 20TB capacity/ Slot and RAID support of RAID 0/1/5/6/10. 6) Connectivity Interface : 2 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232, 1x eSATA Port 7) Backup Interface : Its should have 4 Nosx USB port (2x USB3.0, 2xUSB2.0) 8) Video Output Ports: 2x HDMI and 2 VGA 9) Alarm Ports: It should have 16/8 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc. 10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring, network disconnection and panic 11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing. 12) Protocols: HTTP, HTTPS, TCP/IP, IPv4/IPv6, UDP, DHCP, DNS, SMTP, UPnP, IP Filter, PPPoE, FTP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF 21.12 (Profile T, Profile S, Profile G), CGI, SDK and OEM |
| 197 | Cloud for remote monitoring without any public IP need. 13) Standards: CE, FCC, RoHS, BIS Certified 14) Power Supply : Should support AC100-240V, 50/60Hz Power supply. 15) Operating Condition : -5°C to 50°C, humidity 90% (max) (non-condensing) 16) The VMS application shall support all the features & functionalities of the offered cameras. 17) VMS should consist Licenses for all channels to record Cameras with General, motion detection, intelligent, alarm and POS recording modes. VMS should be provided with Camera Licenses , with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality. 18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage. 19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet. 20) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode 21) It should support Resolution: 32MP; 24MP; 16MP; 12MP; 8MP; 5MP; 4MP; 1080p; 720p; D1; CIF; QCIF (22) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page |
| 198 | 23) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm 24) It should have Web and GUI interface. 25) Built-In Artificial Intelligence: NVR should have built-in AI :- 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, -Minimum 8 Channel Smart Motion Detection 26) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec and facility to add Name, gender, birthday, address, credential type, credential No., countries & regions and state to each face image. 27) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella. 28) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes |
| 199 | 29) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity exception 30) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email. 31) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection. 32) Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiency 34) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics 35) Analytics by NVR: Perimeter protection and face recognation 32 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/32(36), 2nd screen: 1/4/8/9/16_DSR (E&M)_40.11.1 |
| 200 | Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. 8TB (Terabytes)_DSR (E&M)_40.12.3 |
| 201 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 16sq. Mm_UPPWD_504(d) |
| 202 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 35sq. Mm_UPPWD_504(f) |
| 203 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 50sq. Mm_UPPWD_504(g) |
| 204 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 70sq. Mm_UPPWD_504(h) |
| 205 | Add for Invertor Wiring in wiring Point for light/ Fan/ Plug with 1.5 mm Cu Wire_UPPWD_189 A |
| 206 | Supply and fixing hexagonal Round G.P.fan box approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work._DSR Civil 2023 10.18 |
| 207 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required._DSR (E&M)_5.2 |
| 208 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required._DSR (E&M)_6.2 |
| 209 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor and external lighting complete as required. (For Horizontal run)_DSR (E&M)_6.7 |
| 210 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run)_DSR (E&M)_6.8 |
| 211 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required._DSR (E&M)_6.12 |
| 212 | FIRE FIGHTING WORK- |
| 213 | Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 4 Zone_DSR (E&M)_28.1.9.1 |
| 214 | Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or separate) complete with emitter and receiver including connections with remote test features etc complete as required._DSR (E&M)_28.2.12 |
| 215 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required_DSR (E&M)_28.1.3 |
| 216 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required._DSR (E&M)_28.1.6 |
| 217 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of cross linkable Ethylene Propylene Runner (EPR) inshulation and LSZH inner bedding, steel wire armouring & FRLS outer sheath complete as required._DSR (E&M)_28.5.1 |
| 218 | Supply and Fixing 25 mm dia MS Flexible Pipe with PVC Coating Along with all Ancillaries and Accessories_DSR (E&M)_28.5.4 |
| 219 | Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work_UPPWD 1132 |
| 220 | Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along withsupply of all materials and labour for proper completion of work._UPPWD 1131 |
| 221 | Supplying, installation, testing and commissioning of electric driven terrace pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace pump) (b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal as required. (c) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-12615: 2018 (d) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (e) Suitable cement concrete foundation duly plastered and with anti vibration pads. Terrace Pump, Capacity - 900 LPM at 35.00 Meter Head . Make : Kirloskar._DSR (E&M)_27.4.1 |
| 222 | Providing, laying, testing and commissioning of 'C' Class Heavy Duty M S pipe conforming to IS:3589 / IS:1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall / ceiling with suitable clamp / support frame and painting with two or more coats of red oxide and P O red synthetic enamel paint complete in all respects as required. (As per UPPWD/CPWD approved specification) 25 mm dia._DSR (E&M)_27.1 |
| 223 | Providing, laying, testing and commissioning of 'C' Class Heavy Duty M S pipe conforming to IS:3589 / IS:1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall / ceiling with suitable clamp / support frame and painting with two or more coats of red oxide and P O red synthetic enamel paint complete in all respects as required. (As per UPPWD/CPWD approved specification) 80 mm dia._DSR (E&M)_27.7.6 |
| 224 | Providing, laying, testing and commissioning of 'C' Class Heavy Duty M S pipe conforming to IS:3589 / IS:1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall / ceiling with suitable clamp / support frame and painting with two or more coats of red oxide and P O red synthetic enamel paint complete in all respects as required. (As per UPPWD/CPWD approved specification) 100 mm dia._DSR (E&M)_27.7.7 |
| 225 | Supplying and fixing of internal hydrant valve with instantaneous Gunmetal / Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked confirming to IS:5290 (Type -A) with blank Gunmetal / Stainless Steel cap and chain as required ; Single headed Stainless Steel._DSR (E&M)_27.9.2 |
| 226 | Supplying, fixing, testing and commissioning of Butter fly valve of PN 1.6 rating with bronze / gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS:13095 of following sizes as required : 100 mm dia._DSR (E&M)_27.11.5 |
| 227 | Supplying, fixing, testing and commissioning of Non - return valve of following sizes confirming to IS:5312 complete with rubber gasket, G I bolts, nuts, washers etc. as required : 100 mm dia._DSR (E&M)_27.14.5 |
| 228 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange 100 mm dia_DSR (E&M)_27.15.2 |
| 229 | Supplying and fixing of 63 mm dia, 15 Metre long RRL hose pipe with 63 mm dia male and female couplings duly bound with G I wire, rivets etc. confirming to IS:636(type - A) as required :stainless steel Grade (304) _DSR (E&M)_27.16.2 |
| 230 | Supplying and fixing of first aid hose reel with M S construction spray painted in post office red, conforming to IS:884 complete with the following as required : 20 mm nominal internal dia water hose thermoplastic(Textile reinforced) type - 2 as per IS:12585.20 mm nominal internal dia gun metal globe valve and nozzle. Drom and brackets for fixing the equipment on wall. Connections from riser with 25 mm dia stop gum metal valve and M S pipe and socket. 30 Metre_DSR (E&M)_27.17.1 |
| 231 | Supplying and fixing of 63 mm dia short branch pipe with 20 mm nominal internal daimeter size nozzle confirming to IS:903 suitable for instantaneous connection to interconnect hose pipe coupling as required stainless steel Grade (304)_DSR (E&M)_27.18.2 |
| 232 | Supplying and fixing of Fire brigade connection of cast iron body with gun metal male instantaneous inlet coupling complete with cap and chain as required for suitable dia M S pipe connection confirmingto IS : 904 as required . 2 Way - 100 mm dia M S Pipe_DSR (E&M)_27.19.1 |
| 233 | Supplying and fixing of Pressure Switch in M S pipe line including connection etc. as required._DSR (E&M)_27.22 |
| 234 | Supplying and fixing of Flow Switch in following sizes M S pipe including connection etc. as required. 100 mm dia._DSR (E&M)_27.23.1 |
| 235 | MARKET RATE ITEM- |
| 236 | Providing and fixing SWR PVC P trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 110mm x 110mmX110mm (only for estimation)_MR |
| 237 | Supply and fixing of UPVC S.W.R. pipe Nahni Trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali._MR |
| 238 | Supplying and fixing of finolex copper submersible cable ISI marked of size 3x4 sqmm_MR |
| 239 | Supply of Submersibule pump with control panel, support wire etc. complete 7.5 H.P. (KSB / EQ.)_MR |
| 240 | Supply of Mirror Light 10 Watt LED . complete in all respect (only for estimation)_MR |
| 241 | Providing and installing a complete chandelier electrical point, including PVC conduit, FRLS copper wiring of suitable size, phase, neutral and earth connections, junction box, connectors, modular switch and accessories, heavy-duty ceiling hook/support suitable for the chandelier load, termination, testing and commissioning, complete as required at site. Chandelier fixture shall be measured and paid for separately._MR |
| 242 | Supply and fixing of Exhaust fan 12\\" light duty. DBB typee complete with louveer shutter .- Bajaj / usha,Crompton,Havells Make_MR |
| 243 | Data socket outlet_MR |
| 244 | adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters. Proper sized cable termination gland plates shall be provided on cable alleys and knockouts for same shall be provided during fabrication stage itself. The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel. Panel shall be so designed at to have minimum 20% spare feeders/space. Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement. All cable terminations shall be from top. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. MAIN L.T.PANEL(METER PANEL BOARD) Incoming : 250 Amp. MCCB-1 No Outgoing :200 Amps FP MCCB - 2No. 125 Amps FP MCCB - 4No. 63 Amps FP MCCB - 4No. 40 Amps FP MCCB - 3No. OR outgoing as per site requirment (AS/SLD)_MR |
| 245 | Supply, Installation, Testing and Commissioning of wall mounted fan, heavy-duty type, sweep size 450 mm (18\\"), complete with single-phase motor, oscillating mechanism, suitable guard, blades, regulator/speed controller, mounting arrangement and all accessories, including FRLS copper wiring from nearest distribution board/switch box to fan point, PVC/metal conduit, junction boxes, connectors, clips, saddles, screws and necessary hardware, complete in all respects as required for satisfactory operation._MR |
| 246 | Supply, installation, testing and commissioning of Hose Box of 18 SWG M. S. sheet with glass fronted door including locking agreement to accommodate 02 Nos. RRL hose and 01 No. S S branch pipe with nozzle (External) ._MR |
| 247 | Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate size including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge._MR |
| 248 | CONTROL PANELS Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :INCOMING 80A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 125A OUTGOING ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) TERRACE Fire Pump 63 A, 36kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation._MR |
| 249 | Supply,Installation, Testing & Commissioning of modular type Variable Refrigerant Flow / Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermatically sealed invertyer type Scroll Cpmpressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller , top discharge type condensing unit(s), with R 410 A Refrigerant , vibration isolators , with suitable foundation etc.complete as required.The unit shall deliver the rated capacity at AHRI Conditions and work even at 50 °C ambeint temperature without tripping. The unit shall be suitable to work on 400 V+/-10 % ,3 Phase , 50 Hz AC power supply.The unit shall be filled with first charge of refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 Outdoor units shall have external static pressure of minimum 75 Pa to avoid any hot circulation. It is mandatory that each compressor shall have inverter technology separately i.e; outdoor units shall have all inverter based compressor. 14.0 HP_MR |
| 250 | Split Units, Copper pipe and Fittings with complete Assessories 1.0-TR HI-WALL UNIT ( 1 to 1 Ac 3 star)_MR |
| 251 | Split Units, Copper pipe and Fittings with complete Assessories 2.0-TR HI-WALL UNIT ( 1 to 1 Ac 3 star)_MR |
| 252 | Supply,installation,testing and commissioning of including vaccumiazation and Nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for VRV /VRF system, complete with fittings , with suitable adjustable ring type hanger supports , jointing / brazing including accessories , insulated with XLPE Class-O tubular insulation / with Class -o closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid Lines ,all accessories as per specification etc.as required: Note:- 1)The Copper Piping & Piping Circuit should be with Minimum number of joints,which shall be attained by:(i) Using One End Expanded Tubes.(ii) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum. (3) The makes of tube fittings shall be same as that of tubes. (4) The thickness of fittings used shall be same as that of the pipe. 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation._MR |
| 253 | 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation._MR |
| 254 | Supply,installation,testing and commissioning of 2core X 1.5 mm² copper wire in PVC conduit as per specifications (for transmission)_MR |
| 255 | Supply,installation,testing and commissioning of 2core X 1.5 mm2copper wire in PVC conduit as per specifications ( for remotes)_MR |
| 256 | Supply and erection of MS perforated cable tray with Hot Dipped Galvanising on the existing surface with given size to be fixed with fastners/ nut & bolts etc along with , L-angle, U-bend type support . complete in all respect as desired for installation and suitable for running copper refrigerant piping with insulation and control wiring running inside PVC conduit. MS perforated cable tray painted Hot Dipped Galvanised 150mm x 50mm x 1.6 mm (2mm thick)_MR |
| 257 | Providing and fixing of CPVC ,6 Kg/ Cm² drain water piping with fittings ,support and insulated with 6 mm thick closed cell elastomeric nitrile rubber insulation complete as per specification. 50 mm dia_MR |
| 258 | Supplying , installation , testing & commissioning of flexible duct connection constructed of fire resistance flexible double canvas sleeve as per requirement etc.complete as required and as per specifications._MR |
| 259 | Supplying & fixing of powder coated extruded aluminum Air Grills with aluminium Volume control damper as per specification._MR |
| 260 | Supplying & fixing of powder coated extruded aluminium Return Air Grilles with louvers but without volume control dampers complete as required._MR |
| 261 | Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws, linkages, flanges etc, as per specifications._MR |
| 262 | Supplying , Fixing , testing & commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring , the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored .The spring return action shall be inbuilt mechanism and not externally mounted.The damper shall also be closed in the eventof fire signal complete as required and as per specifications. Fire damper_MR |
| 263 | Supplying , Fixing , testing & commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring , the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored .The spring return action shall be inbuilt mechanism and not externally mounted.The damper shall also be closed in the eventof fire signal complete as required and as per specifications. Actuator_MR |
| 264 | Non Return Damper_MR |
| 265 | Supply, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators, cooling coil section with aluminium finned copper tubes. suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply suitably designed for varialbe frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation. 9000 CFM, 22.5 TR, 75 mm E.S.P. _MR |
| 266 | Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet (24G) 301-750MM_MR |
| 267 | Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.80 mm sheet (22G) 751-1000MM_MR |
| 268 | Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 1.00 mm sheet (20G) 1001-1500MM_MR |
| 269 | Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 1.25 mm sheet (18G) 1501-2250MM (plenum)_MR |
| 270 | Supplying, fixing testing commissioning of Exhaust air Grill of powder coated aluminium without volume control dampers with anti smudge ring & removable core._MR |
| 271 | Supplying, fixing testing commissioning of Fresh air grill of powder coated aluminium without volume control dampers with anti smudge ring & removable core._MR |
| 272 | Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m3, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications. Note: Duct accoustic linning upto 3 meters length from the AHUs connection point including the plenum box._MR |
| 273 | Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class \\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 19 mm thick_MR |
| 274 | Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class \\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 25 mm thick_MR |
| 275 | Supply, installation, testing and commissioning of Fire Rated Tube Axial flow fans complete with tube casing, impeller, bird screen, gravity louvers, necessary nut bolts, Necessary transition piece and canvas connection for proper Installing, silencers on inlet and outlet and directly coupled TEFC Sq.cage, EFF-1 High efficiency induction motor mounted on vibration isolators suitable for 415V±10%, 50 Hz. 3 phase electric supply complete as per the technical specifications enclosed. The fans should be AMCA certified for air performance & sound ratings. The fan should be rated for a minimum of 250 Deg C for a minimum of 2 Hrs. Application.The fan shall be complete in all respect and should match the specification ,Drawings and Schedule..The quoted price shall consist of mounting arrangemnt along with spring isolator for fan. The unit shall be capacble to communicate with BMS system. For dia upto 1120 mm fan RPM should be 1450 and above 1120mm dia fan RPM should be 950 Note: Noise level should be selected for 3 meter distance from fan at room condition.For normal case - 80db(A)@3m For Emergency case - 90db(A)@3m 4000 CFM ,Total static pressure of 30 MM WG FOR SMOKE EXTRACTION_MR |
| 276 | Supply, installation, testing and commissioning of Fire Rated Tube Axial flow fans complete with tube casing, impeller, bird screen, gravity louvers, necessary nut bolts, Necessary transition piece and canvas connection for proper Installing, silencers on inlet and outlet and directly coupled TEFC Sq.cage, EFF-1 High efficiency induction motor mounted on vibration isolators suitable for 415V±10%, 50 Hz. 3 phase electric supply complete as per the technical specifications enclosed. The fans should be AMCA certified for air performance & sound ratings. The fan should be rated for a minimum of 250 Deg C for a minimum of 2 Hrs. Application.The fan shall be complete in all respect and should match the specification ,Drawings and Schedule..The quoted price shall consist of mounting arrangemnt along with spring isolator for fan. The unit shall be capacble to communicate with BMS system. For dia upto 1120 mm fan RPM should be 1450 and above 1120mm dia fan RPM should be 950 Note: Noise level should be selected for 3 meter distance from fan at room condition.For normal case - 80db(A)@3mFor Emergency case - 90db(A)@3m 6000 CFM FOR FRESH AIR MAKE-UP_MR Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayNov 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender