Tender For Amrut-Amrut - 2.0-Fund Utilization - Balance Work - Supply , Erection, Trial Running And Commissioning Of Clear Water Centrifugal Motor Pump At Kayarampara Wtp To Cherikkunnu Glsr , Supply , Erection And Commissioning Of 315 Kva Transforme
Tender Overview
Project Description
Tender for Amrut-Amrut - 2.0-Fund Utilization - Balance Work - Supply , Erection, Trial Running And Commissioning Of Clear Water Centrifugal Motor Pump At Kayarampara Wtp To Cherikkunnu Glsr , Supply , Erection And Commissioning Of 315 Kva Transformer With Yard At Kayarampara Wtp Compound And Existing Pumping Main Linking To Cherikkunnu Glsr And Linking At Ottapalam Tb Compound Near And Linking Of Ottapalam And Ambalappra Clear Water Sump And Allied Works Etc. In Ottapalam Municipality-Pipeline Work
BOQ
| Sl. No. | Item Description |
| 1 | Supply, Erection ,Testing and Commissioning of 110 HP Centrifugal motor pumpset |
| 2 | OD63254/2026-2027:Supply, erection, testing and commissioning of KWA pre-qualified reputed make Water lubricated Horizontal Split Case Centrifugal pump set having a Duty conditions of 82 lps & 70 m head, with Bronze impeller, SS shaft, Steel Columns, Steel Strainer, CI Bowls & Bell mouth, CI Discharge head, Bronze wear rings having coupled motor of KWA pre qualified reputed make horizontal solid shaft pump mounted TEFC squirrel cage 4 pole induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415V. The motor shall confirm to EEF1/IS 325 digital motor protection relay shall be included in starter as per present IE rules with foundation bolts & nuts, base frame for pump and motor etc. complete including providing suitable concrete foundation in RCC with CC not less than 1:1.5:3 in 20 mm broken stone, fixing of M.S base frame on the concrete foundation, fixing of pump and motor and coupling them with suitable coupling including cost of cement, sand and broken stone and all other materials, labour charges, hire charges etc. complete. The alignment of the Pump and Motor coupled shall be with out any vibration during running. The combined efficiency of pump and motor shall not be less than 70% |
| 3 | OD63252/2026-2027:Supply, erection, testing and commissioning of suitable rating soft starter with air break contact. Starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete. |
| 4 | OD63256/2026-2027:Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer, suitable rating ELCB/ELR, suitable rating Single phasing preventor, subitable rating Change Over Switch and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. Panel board including MCCBs, Bus bars & accessories shall be suitable for a min. rating of 200 amps or suitable for the motor. The panel board shall be connected to Main Switch Board using suitable rating Copper Cables |
| 5 | OD63258/2026-2027:Supply, laying, testing and commissioning of suitable size XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE of necessary length and free runs for the above pump set from panel board to starter and from starter to motor considering energy conservation. |
| 6 | OD63257/2026-2027:Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. |
| 7 | OD63259/2026-2027:Supply, erection, testing and commissioning of APP Metalised poly propeline capacitor Heavy duty, 440V Cylinderical Gas filled type capacitor / Capacitor bank for the motor to get a power factor above 0.98. The capacitor shall confirm to IS 2834. |
| 8 | OD63255/2026-2027:Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Double Flanged Non return valve, both with PN 16 pressure rating including cost of all materials, labour, hire charges etc. complete. Valve sizes shall match the delivery size of the pump. |
| 9 | OD63253/2026-2027:Supplying, Fabricating and fitting of suitable size best quality GI/MS pipe of thickness not less than 10mm suitable for the above pump and connecting the suction side of the pump and delivery side of the pump with the Sluice valves, Non-Return Valves, suitable specials, flanges, nut and bolts IR sheet etc. complete to connect with the 300 mm DI K9 pumping main including cost of all GI & MS pipe and specials, MS flanges with min. of 12 mm thickness, DI K9 pipes if required, DI K-12 Specials, Cast Iron foot valves for each pump of size matching the suction pipe, Pressure guage with 6" dial and having stop cock, necessary anchor blocks in RCC with CC not less than 1:1.5:3 in 20 mm broken stone including cost of all materials, labour, hire charges etc. complete. All interconnections of pipe lines in the delivery side of the pump shall be done in "Y" pattern only. NRV shall be support with RCC Anchor Block. |
| 10 | Supply, testing, erecting & commissioning of 315 KVA Oil immersed Outdoor Type transformer with yard, cabling and allied work at WTP compound , Kayarampara |
| 11 | OD90615/2026-2027:Supply & Lying of 3Cx300 sq.mm. 11 KV XLPE power cable of best conductivity Al.conforming to IS. in ground or Existing Tray Make: Finolex/RR/KEI/Havels |
| 12 | OD90617/2026-2027:Supply & Termination of 3Cx300 sq.mm. 11KV OUTDOOR Termination conforming to IS. Make: Raychem/Multishrink/3M |
| 13 | OD90623/2026-2027:Supply & Termination of 3Cx300 sq.mm. 11KV INDOOR Termination conforming toIS.Make: Raychem/Multishrink/3M |
| 14 | OD90633/2026-2027: Supply, Installation, Trial running and Commissioning of 11KV /433V 315KVA, 3-Phase, 50 Hz, Oil Immersed Natural (ONAN) High Efficiency / Premium Copper Wound Outdoor Type Transformer , 11KV/433V, 315KVA 3-Phase, 50 Hz, Outdoor Type, Oil Immersed Natural (ONAN)Energy Efficiency Level-2 as per IS-1180, High Efficiency / Premium Copper Wound – Outdoor Manufacturing and Supply of 11kV/433V, 315KVA, 50Hz, 3phase, Oil Immersed Natural (ONAN) Outdoor Type Transformer with off circuit tapping +5% to -5% in steps of 2.5% with winding temperature indicator and hooter & LV side Cable box with MCCB and HV terminal connected to the 11kv VCB Panel with KSEBL Metering 11KV VCB Panel with HT Metering - Outdoor Manufacturing and Supply of Outdoor type 11kV, 630A, 26.3kA for 3 sec Horizontal Draw ou VCB fitted with Manual/Motor operated spring charging mechanism with 230V AC motor and motor control switch, shunt trip coil of 24V DC, closing coil of 24V DC, Auxiliary Contact 2NO + 2NC, Mechanical ON/OFF indicator, mechanical operation counter, Anti pumping feature, overcurrent and earth fault relay, protection CT, (--/5 A, 5P10, 15VA , 11kV/110V, Cl- 0.2, 25VA PT Instantaneous IDMT relay with Microprocessor based 3O/C + and 1EF Protection relay, Strip Heater with thermostat, Power pack 230V AC-24 V DC emergency OFF push button, Digital Ammeter & Digital Voltmeter etc and HT metering equipments (3nos *-/5A Oil immersed type (ratio as per the Contract demand) & 1no 3 Phase 11KV/110V Resin Cast PT Unit) with Provision for fixing TOD Meter for KSEBL metering etc. complete. |
| 15 | OD99026/2026-2027:Supply and Installation of CT AND PT UNIT Following Specification; including labour and material charges having follwing specifications: CURRENT TRANSFORMER - Ratio : Out door CT PT unit Oil type-11KV - 15/5A CL 0.2S, Frequency : 50HZ, Voltage Level : 11KV, Highest System voltage : 12 KV, VOLTAGE TRANSFOMER - Ratio : PT 11KV/110V, 25VA CL 0.2 , Frequency : 50HZ, Voltage Level : 11KV, Highest System voltage : 12 KV, |
| 16 | OD99050/2026-2027:Supply and installation of TOD Meter suitable for 315 KVA Transformer including all cost and labour and material charges etc. complete. |
| 17 | OD99061/2026-2027:KSEB,Testing, calibration of CTPT units and TOD meter from TMR Division and issued Test certificate including transporting, loading and unloading charges etc., (Testing fees payable at authority shall be meet the client) including labour charge |
| 18 | OD98037/2026-2027:Supply, Installation, Trial Running and connissioning of High Tension (HT) cabling For a 315 kVA, 11 kV/433V distribution transformer- 11 kV Grade XLPE Cable sized at a minimum of 3-core × 35 sq.mm (or up to 95 sq.mm / 120 sq.mm depending on fault level and utility standards) stranded aluminum/copper, protected with galvanized steel wire/strip armoring and terminated with indoor/outdoor heat-shrinkable jointing kits including necessary earthwork excavation on cable trays, or pulled through HDPE/GI pipes at road crossings. Sand cushioning (150 mm below and above) and protective second-class brick/RCC tile covering with warning tape must be provided including Bending Radius: Maintained at strictly no less than 12 × overall cable diameter during laying to prevent insulation damage.Supports & Clamping: Spaced at intervals not exceeding 1.5 meters using non-magnetic or heavy-duty GI clamps for vertical/rack runs.Earthing Continuity: Armor wire/strip must be reliably terminated to the substation earth mat at both the HT switchgear (VCB/LBS) and transformer body ends using adequate size copper/GI earth strips. |
| 19 | OD94162/2026-2027:Supply, Installation, Trial Running and commissioning of LT (Low Tension) panel board for a 315 kVA (415V, 3-phase, 50Hz) for transformer and allied work - 630A busbar rating, CRCA sheet steel construction, and an incoming 500A MCCB all cost and installation charges etc. complete |
| 20 | OD94204/2026-2027:Supply, Installation, Trial Running and commissioning of 315 kVA High-Tension (HT) Panel Board- 11 kV system voltage, a Vacuum Circuit Breaker (VCB), and robust indoor or outdoor metal enclosures including all cost and labour charges |
| 21 | OD90657/2026-2027:SITC of EFR along with its control wiring and CT and enclosure. Make: EFR L&T and CTPGR/El Power |
| 22 | OD90661/2026-2027:Supply & Lying of 3.5Cx300 sq.mm. 415V XLPE power cable of best conductivity Al.conforming to IS. in ground or Existing Tray including its 4 Nos.terminations. Make: Finolex/RR/KEI/Havels |
| 23 | OD90668/2026-2027:Supply, testing and erection of installation of 75/5A, CL 0.5 P 10, 15VA Neutral with suitable metal enclosure(specification of N/CT will be change with actual load Details |
| 24 | OD90671/2026-2027:APFC PANEL-100Kvar Ultra Heavy Duty Capacitors Incomer: 250A TPN SFU with FuseOutgoings:50Kvar Capacitor,125A TPN SFU with fuse and 70A contactor - 1No 20KvarCapacitor 63A TP MCB with 32A Contactor - 1No 10Kvar Capacitor 32A TP MCB with 32A Contactor - 3Nos Make :L&T 6stage APFC Relay and Indicators |
| 25 | OD90680/2026-2027:Supply installation testing and commissioning of HT Unidirectional Meter 110v, 0-5ACL:0.2Swith Accessories. Make:L&T |
| 26 | OD90683/2026-2027:Supply & providing efficient plate earthing arrangements as per IS 3043 using1200x1200x12mm CI plate electrode, 12mm GI watering pipe clamped to the plate andextending to the middle of the plate, with necessary earth pit and filling around the plate 15cmwith charcoal, sand and soil etc. as per IS 3043 ( No. of earth will be confirmed after the soilresistivity test.) |
| 27 | OD90687/2026-2027:Laying of 25*6 Gi Strip Earthing |
| 28 | OD90692/2026-2027:Supply and Lying of 10Swg Cu |
| 29 | OD90700/2026-2027:Supply and fixing of items Like Gloves Chart,Fire Buckets Etc |
| 30 | OD90711/2026-2027:Preparation of Scheme for approval and sanction from electrical inspectorate and KSEB Document Works.(Excluding all fees and other official charges) |
| 31 | Construction of Transformer yard and Coursed Rubble plinth and allied work at 13MLD Clear water pumping station |
| 32 | 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 33 | 15.9.1:Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In Lime Mortar |
| 34 | 7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 35 | 50.2.25.1:Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge |
| 36 | 7.6.1:Coursed rubble masonry (first sort) with hard stone in foundation and plinth with:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 37 | 13.35.1:Pointing on stone slab ceiling with cement mortar 1:2 ( 1 cement : 2 fine sand):Flush / Ruled pointing |
| 38 | 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 39 | 4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns |
| 40 | 5.22.1:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars |
| 41 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 42 | 13.9.1:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster |
| 43 | OD91042/2026-2027:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete for yard and gate |
| 44 | 13.92.1:Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Old work (one or more coats) |
| 45 | OD91057/2026-2027:Supplyig of 2 to 6mm and 6mm to 12mm size fine pebble(pebbles shall be hard,clean,free from clay,dust and other impurities),stacking in stardard heeps for measurement includig cost,conveyance upto 5Km amnd labour charges for stacking ,spreading |
| 46 | 13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 47 | 11.49.2:Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tiles 600x600 mm |
| 48 | 15.23.1:Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 49 | Working charge - Inter linking Existing pumping main and interlinking of sump at WTP, Kayarampara |
| 50 | 100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil. |
| 51 | 100.2.2:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10m2 on plan), including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited. |
| 52 | OD94068/2026-2027:Dismantling of Existing 350mm DI pipe ( 50% rate of cost of Laying) |
| 53 | OD94052/2026-2027:Labour for cutting and joining DI pipe with steel saw 350 mm diameter DI pipe |
| 54 | 100.15.6:Conveying and laying Double Flanged (Screwed / Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS: 8329, excluding cost of pipe and specials: 350mm diameter Ductile Iron Double Flanged pipes. |
| 55 | OD98403/2026-2027:Conveyance of 350mm DI K9 pipe (42.0 metre) from Division store Shornur to sites at ottapalam including all cost and labour charges etc.complete |
| 56 | 100.35.6:Testing 350mm DI/CI pipeline with potable water to the required test pressure.350 mm diaObserved Data derived from item no.1024 of PHED DATA |
| 57 | 18.73.6:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :350 mm dia Ductile Iron Double Flanged |
| 58 | 100.41.39:Supply, stacking, spreading and consolidating of Quarry Muck in the trench of pipe line, including carriage, loading, unloading & stacking up to any lead. |
| 59 | 100.59.1:Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation. |
| 60 | 15.3:Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. |
| 61 | 4.1.2:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3graded stone aggregate 20 mm nominal size derived from natural sources) |
| 62 | 5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 63 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 64 | 100.31.2.8:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 350mm diameter, Class II. |
| 65 | 18.30.8:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:350 mm diameter pipe |
| 66 | 18.68.1:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Upt 600 mm dia |
| 67 | 18.69.1:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Upto 600 mm dia |
| 68 | 18.70.6:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:350 mm dia pipes |
| 69 | 100.98.1007:Engaging Beldar |
| 70 | 100.98.1009:Engaging Fitter ( grade 1). |
| 71 | 100.98.1010:Engaging Assistant Fitter or 2nd class fitter. |
| 72 | 100.37.10.1:In situ fabrication of M.S. pipes of size 350mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete. |
| 73 | 100.37.10.2:Fabricating M.S. flanges of diameter 350mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates. |
| 74 | 100.37.10.3:Cutting 350mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates. |
| 75 | 100.37.10.4:Welding 350mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates. |
| 76 | 100.37.10.5:Grinding cut and weld edges of 350mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates. |
| 77 | Cost of materials ( Specials) |
| 78 | 100.98.464:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 350mm. |
| 79 | Consruction of RCC valve chamber |
| 80 | 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 81 | 4.1.2:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3graded stone aggregate 20 mm nominal size derived from natural sources) |
| 82 | 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 83 | 5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 84 | 5.9.16.2:Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsAbove 20 cm wide |
| 85 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender