Tender For Repair/ Replacement / Maintenance Of Old Control Panels, Switchgrears, Bus Bars, Cables, Crane Tracks And Connected Repairs Of Various Eot Cranes & Lifts At 512 Abws And Cafvd Tech Area At Age E/M-Ii Under Ge (C) Khadki
Tender Overview
Project Description
Tender for Repair/ Replacement / Maintenance Of Old Control Panels, Switchgrears, Bus Bars, Cables, Crane Tracks And Connected Repairs Of Various Eot Cranes & Lifts At 512 Abws And Cafvd Tech Area At Age E/M-Ii Under Ge (C) Khadki
BOQ
| Sl. No. | Item Description |
| 1 | M&L for dismantling and removing of old unserviceable limit switch any type and S&F heavy duty two way lever type limit switches with 2 contacts and rated voltage upto 500V , 40 Amps with enclosure including nut , bolts , washers, suitable size matching existing mounting bracket incl addn alteration demmed to be inclusive of rates etc and all electric connection done to existing cable complete all as specified and directed by Engr-in -charge. Make :- Top Enterprises/Speedocontrol or equivalent |
| 2 | All as per Item No 1.00 above but heavy duty one way gravity/Counter weight limit switches with 2 contacts and rated voltage upto 500V , 40 Amps complete all as specified and directed by Engr-in -charge. Make :- Top Enterprises/BCH/Speedocontrol or equivalent |
| 3 | All as per Item No 1.00 above but heavy duty Rotary geared type shunt limit switches with 2 contacts and rated voltage upto 500V , 40 Amps complete all as specified and directed by Engr-in -charge. Make :- Top Enterprises/BCH/Speedocontrol or equivalent |
| 4 | M&L for electrical fault finding and rectification in limit switch, up down motion, CT motion, LT motion in any type of crane uto 50Ton and any type of panel by dismantling the old wire / switchgears, MCB's, MCCB's complete cleaning and fault rectification including all electrical fault with replacement of the defective components, and testing of crane for smooth functioning complete all as specified and directed by Engr-in -charge. Note : Rates are inclusive of small wires of suitable size, connectors, lugs, insulation tape etc. |
| 5 | M&L for mechanical fault finding and rectification in any type of crane upto 50 Ton by dismantling/ checking, inspecting the mechanical items like brake shoes, thruster assy, motor coupling, drum, gear box and other meachanical part complete by tightening nut bolts, washers, cleaning and fault rectification with replacement of the defective components incl minor welding, brazing, fabricating and testing of crane for smooth functioning complete all as specified and directed by Engr-in -charge. Notes -Rates are inclusive of nut bolt washers of suitable size, grease etc. |
| 6 | M&L for taking down old unserviceable items of the crane panel and S&F following items, connecting and testing, commisioning including minor addn alteration, lugs, nut bolts, washers, spreader links, seperaters, mounting arrangements etc required at site complete all as specified and directed by Engr-in -charge. |
| 7 | All as per Item No 6.00 above but MCCB 400 Amps 36KA, TP, Icu=Ics=100% with thermal magnetic release. |
| 8 | All as per Item No 6.00 above but MCCB 250 Amps 36KA, TP, Icu=Ics=100% with thermal magnetic release. |
| 9 | All as per Item No 6.00 above but MCCB 100 Amps 25KA, TP Icu=Ics=100% with thermal magnetic release. |
| 10 | All as per Item No 6.00 above but MCCB 63 Amps 25 KA, TP Icu=Ics=100% with thermal magnetic release. |
| 11 | All as per Item No 6.00 above but MCB 40 Amps, C series , 10 KA, TP |
| 12 | All as per Item No 6.00 above but MCB 6 - 32 Amps, C series , 10 KA, TP |
| 13 | All as per Item No 6.00 above but MCB 10 - 25 Amps, C series , 10 KA, SPN |
| 14 | All as per Item No 6.00 above but MCB 6 - 16 Amps, C series , 10 KA, SP |
| 15 | All as per Item No 6.00 above but Single Phasing Preventor SPP 3 PH 415 VAC din rail type (3 Phase) |
| 16 | All as per Item No 6.00 above but Power Contactor 110A 3P 415V AC (AC 3) with In-Built 2NO + 2NC & 110V AC Coil (50 Hz). Note:- NO/NC should be inbuilt type, not add on block type. |
| 17 | All as per Item No 6.00 above but Power Contactor 70A 3P 415V AC (AC 3) with In-Built 2NO + 2NC & 110V AC Coil (50 Hz). Note:- NO/NC should be inbuilt type, not add on block type. |
| 18 | All as per Item No 6.00 above but Power Contactor 40A 3P 415V AC (AC 3) with In-Built 2NO + 2NC & 110V AC Coil (50 Hz). Note:- NO/NC should be inbuilt type, not add on block type. |
| 19 | All as per Item No 6.00 above but Power Contactor 32A 3P 415V AC (AC 3) with In-Built 2NO + 2NC & 110V AC Coil (50 Hz). Note:- NO/NC should be inbuilt type, not add on block type. |
| 20 | All as per Item No 6.00 above but Power Contactor 18A 3P 415V AC (AC 3) with In-Built 2NO + 2NC & 110V AC Coil (50 Hz). Note:- NO/NC should be inbuilt type, not add on block type. |
| 21 | All as per Item No 6.00 above but Power Contactor 12A 3P 415V AC (AC 3) with In-Built 2NO + 2NC & 110V AC Coil (50 Hz). Note:- NO/NC should be inbuilt type, not add on block type |
| 22 | All as per Item No 6.00 above but Auxilary contactor 10 Amps, 3pole AC 415 V contacts and coil voltage 110 volts AC. |
| 23 | All as per Item No 6.00 above but Elctronic timer ON delay/ OFF delay 0-30 sec. |
| 24 | All as per Item No 6.00 above but Thermal Over load relay of range 3 to 5 Amps including mounting kit complete |
| 25 | All as per Item No 6.00 above but Thermal Over load relay range from 6 to 10 Amps including mounting kit complete |
| 26 | All as per Item No 6.00 above but Thermal Over load relay range from 45 to 75 Amps including mounting kit complete |
| 27 | All as per Item No 6.00 above but Thermal Over load relay range 66 to 110 Amps including mounting kit complete |
| 28 | All as per Item No 6.00 above but Add on aux contact block, front/side mounting type, suitable for MNX type contactor 2NO+2NC |
| 29 | All as per Item No 6.00 above but Add on aux contact block, front/side mounting type suitable for MNX type contactor 1NO+1NC |
| 30 | All as per Item No 6.00 above but Step down transformer, suitable for EOT Crane, copper wound, resin cast, 415/110 volts, 800 VA all as per existing complete all as specified and directed by Engr-in -charge. |
| 31 | All as per Item No 6.00 above but Step down transformer, suitable for EOT Crane, copper wound, resin cast, 415/220 volts, 800 VA all as per existing complete all as specified and directed by Engr-in -charge. |
| 32 | M&L for replacement of unsv PVC Insulated and sheathed, industrial, multi core, stranded, copper conductor cable, 1100 V grade suitable for EOT Crane, connecting to various control devices, junction boxes on EOT crane of any capacity including copper lugs, ferrules, bimettalic washer and clamps for fixing cable in panel or any indicated work including dismantling carefully and removing unserviceable cable of size 1.5 Sqmm 4 core complete all specified and as directed by Engr-in-Charge. |
| 33 | All as per Item Ser No 32.00 above but cable of size 2.5 Sq mm 4 core |
| 34 | All as per Item Ser No 32.00 above but cable of size 4 Sq mm 4 core |
| 35 | All as per Item Ser No 32.00 above but cable of size 6 Sq mm 4 core |
| 36 | All as per Item Ser No 32.00 above but cable of size 10 Sq mm 4 core |
| 37 | M&L for replacement of old unsv XLPE Insulated, PVC sheated, armoured, stranded, copper conductor cable, of size 25 Sqmm 4 core, 1100 V grade, as per IS 7098 (Pt-I) 1988, suitable for EOT Crane, connecting to various control devices, junction boxes on EOT crane of any capacity including copper ferrules, copper lugs , bimetalic washers and clamps for fixing cable in panel or any indicated work including dismantling carefully and removing unserviceable cable complete all as specified and directed by Engr-in -charge. |
| 38 | All as per Item Ser No 37.00 above but cable of size 10 Sq mm 4 core |
| 39 | All as per Item Ser No 37.00 above but cable of size 16 Sq mm 4 core |
| 40 | All as per Item Ser No 37.00 above but cable of size 35 Sq mm 4 core |
| 41 | All as per Item Ser No 37.00 above but cable of size 50 Sq mm 4 core |
| 42 | All as per Item Ser No 37.00 above but cable of size 70Sq mm 4 core |
| 43 | Note for Item 37 to 42 : (i) Necessary saftey measures to be taken by the contractor while dismantling and fixing the cable on Crane at any height. (ii) Any damage to govt property while exceuting the work is to be make good and serviceable at no any extra cost. (iii) Contractor should visit site before quoting the tender. (iv) The cost of Scaffolding arrangement/Ladders/ Safty belts/ Lifting Jacks and T & P used while working on the Crane will be beared by the contractor itself. |
| 44 | Dismantlling & removing old coupling sets, opening the motor for repair, taking out the burnt copper wire from motor, cleaning the stator thoroughly, rewinding the motor with super enameled copper wire of same gauge complete with Varnish, heating the winding, reassembling and incl connecting testing complete the motor of EOT Crane of capacity 72.5 HP complete all as specified and directed by the Engr-in-Charge. |
| 45 | All as per Item No 44.00 above but capacity of motor 21 to 30 HP |
| 46 | All as per Item No 44.00 above but capacity of motor 11 to 20 HP |
| 47 | All as per Item No 44.00 above but capacity of motor 6 to 10 HP |
| 48 | All as per Item No 44.00 above but capacity of motor upto 5 HP |
| 49 | Dismantling and taking out old slip ring from the slip ring motor of capacity 72.5 HP and taking out carbon brushes alongwith holder from it's position and cleaning the complete rotor assembly with CTC solvent and fixing new slip ring with new carbon bushes and it's holder of existing type incl connecting testing complete all as specified and directed by Engr-in -charge. |
| 50 | All as per Item No 49.00 above but capacity of motor 21 to 30 HP |
| 51 | All as per Item No 49.00 above but capacity of motor 11 to 20 HP |
| 52 | All as per Item No 49.00 above but capacity of motor 6 to 10 HP |
| 53 | All as per Item No 49.00 above but capacity of motor upto 5 HP |
| 54 | S&F in replacement of shrouded copper conductors bus bar TPN (4 bar) with PVC sleaves RYBG, DSL 4 bar, hanger clamps, anchor clamps, power feed kit and caps, joining tool with towing arm, end cap complete for 125 Amps to 160 Amps Copper conductor busbar system, including MS fabricated support for mounting of conductors at every one mtr distance, connecting testing complete incl dismantling of old unsv bus bar of nay type and any size complete all as specified and directed by Engr-in -charge. Make- Safe-track/Safe-Line/ or any make approved by GE |
| 55 | All as per Item No 54.00 above but bus bar capacity of 250 Amps |
| 56 | S&F DSL ( DSL Busbar Phase Indicator Lamp ) to show active status of a 3-phase power supply (Red, Yellow, Blue) on crane systems. 415 Vac Input Voltage, 3W to 5W per phase, Weatherproof and rugged powder-coated metal with an IP65 rating to withstand outdoor industrial dust, water, and mechanical vibration with External wall-mounting bracket or direct structural/girder mounting incl with pre-wired long flexible pigtail harnesses for direct connection to the busbar or crane control panel complete all as specified and directed by Engr-in -charge. |
| 57 | M&L for cleaning and servicing of EOT crane track, checking and rectification of fault of pressure plates incl fabrication, nut bolts, washers, side support plates, rail, replacement of worn out plate, nut & bolts and pressure plate, rail at required distance, including repair/ replacement of rail track with necessary welding / cutting/ brazing, grinding and any other machining work for smooth functioning of EOT crane of capacity upto 5 ton complete all as specified and directed by Engr-in -charge. Note :- (i) Contractor should visit site before quting. Necessary safetymeasures to be taken by the contractor while dismantling and fixing the Crane Wheels as the work site is at the height of approx 20 ft. (ii) Any damage to govt property while exceuting the work is to be make good by the contractor ar no extra cost. (iii) Contractor should provide skilled labour while executing the job.(iv) The cost of Scaffolding arrangement/Ladders/ safetybelts/ Lifting Jacks and T & P used while working in the Crane will be beared by the contractor itself. |
| 58 | All as per Item No 57.00 above but crane capacity from 10 Ton to 20 Ton |
| 59 | All as per Item No 57.00 above but crane capacity from 50 Ton |
| 60 | M&L for dismantlling & removing of driving shaft, coupling sets of crane and repair/replacement of unserviceable coupling, nut & Bolts, washers, spacers and removing bend of shaft by grinding, machining, brazing and any other mechanical work for balancing the shaft with drive wheel and motor, greasing to the all moving parts complete for the EOT Crane of capacity upto 5 Ton with the necessary works/alteration/fabrication to make it functional complete all as specified and directed by Engr-in -charge. Note: Coupling and bearing will be paid seperately under respective items of schedule. |
| 61 | All as per Item No 60.00 above but crane capacity from 10 Ton to 20 Ton |
| 62 | All as per Item No 60.00 above but crane capacity 50 Ton |
| 63 | Supply only coupling of crane as per exisitng suitable for driving shaft of EOT Crane upto 5 Ton complete all as specified and directed by Engr-in -charge. |
| 64 | Supply only coupling of crane as per exisitng suitable for driving shaft of EOT Cranefrom 10 Ton to 20 Ton complete all as specified and directed by Engr-in -charge. |
| 65 | Supply only coupling of crane as per exisitng suitable for driving shaft of EOT Cranefrom 50 Ton complete all as specified and directed by Engr-in -charge. |
| 66 | Supply only Bearing as per existing number suitable for EOT Crane upto 5 Ton complete all as specified and directed by Engr-in -charge. |
| 67 | Supply only Bearing as per existing number suitable for EOT Crane 10 Ton to 20 Ton complete all as specified and directed by Engr-in -charge. |
| 68 | Supply only Bearing as per existing number suitable for EOT Crane 50 Ton complete all as specified and directed by Engr-in -charge. |
| 69 | Supply,Fixing and testing, commissioning of Electro Hydraulic thruster of size / capacity 18 Kgs all as existing type with first fill of hydraulic oil incl dismantling and removing old unsv thruster complete all as specified and directed by Engr-in -charge. . Make :- Top Enterprises/ Speedocontrol or equivalent |
| 70 | Supply, Fixing and testing commissioning of Electro Hydraulic thruster of size / capacity 34 Kgs all as existing type with first fill of hydraulic oil incl dismantling and removing old unsv thruster Scomplete all as specified and directed by Engr-in -charge. Make :- Top Enterprises/ Speedocontrol or equivalent |
| 71 | S&F of SS punched grid resistance box suitable for 72.5 HP slip ring motor having RV volts and RA Amps as per existing specifications with 5 steps and 10 min rating suitable for EOT crane slip ring motor as per existing specification incl dismantling and removing old unsv resistance box complete all as specified and directed by Engr-in -charge. Make:- Top enterprises / Speedocontrol or equivalent |
| 72 | S&F SS Punched Grid resistor box type 4/5 steps 10 min. rating suitable for 10/17.5 HP Slip ring Motor of EOT Crane and Rotor volt and RA all as per existing specification incl dismantling and removing old unsv resistance box complete all as specified and directed by Engr-in -charge. Make:- Top enterprises / Speedocontrol or equivalent |
| 73 | S&F SS Punched Grid resistor box type 4/5 steps 10 min. rating suitable upto 5.0 HP Slip ring Motor of EOT Crane and Rotor volt and RA all as per existing specification incl dismantling and removing old unsv resistance box complete all as specified and directed by Engr-in -charge. Make- Top enterprises / Speedocontrol or equivalent |
| 74 | S&F in replacement of existing 3-phase and earth current collectors for shrouded-type copper bus bars, rated for 160 Amps, including dismantling of old/damaged collectors, matching alignment, secure electrical connections, and testing for smooth movement and proper electrical contact complete all as specified and directed by Engr-in -charge. Make:- Safe Track/Top Enterprises/Safe line/Electro power/SRP or equivalent |
| 75 | S&F in replacement of existing 3-phase and earth current collectors for shrouded-type copper bus bars, rated for 250 Amps, including dismantling of old/damaged collectors, matching alignment, secure electrical connections, and testing for smooth movement and proper electrical contact complete all as specified and directed by Engr-in-charge. Make:-Safe Track/Top Enterprises/Safe line/Electro power/SRP or equivalent |
| 76 | S&F in replacement of existing 3-phase and earth current collectors for shrouded-type copper bus bars, rated for 400 Amps, including dismantling of old/damaged collectors, matching alignment, secure electrical connections, and testing for smooth movement and proper electrical contact complete all as specified and directed by Engr-in-charge. Make:- Safe Track/Top Enterprises/Safe line/Electro power/SRP or equivalent |
| 77 | Supply, installation, testing, and commissioning of a Wireless Radio Remote Control (RRC) system for the existing crane control panel, including necessary control wiring modifications/ installation, System Voltage 110V/220V AC supply. Configuration - 6 motion buttons, 1 stop button, and 1 start switch. Includes the dismantling and safe removal of the existing unserviceable remote system. Rates are inclusive of suitable size multicore control cable and fabrication, addn altration etc incl all essential mounting accessories and hardware, incl taking down old unsv system any type complete all as specified and directed by Engr-in-charge. . Make:- SRP or equivalent make. |
| 78 | M&L for repairing and re-termination of existing crane junction box, including the removal of damaged components, cable ends, lugs etc. including replacement with new heavy-duty copper/aluminum lugs, compression cable glands, ferrules, and terminal connectors, complete with proper cable dressing, identification tagging, and sealing to ensure IP-rated protection by placing gasket sheet on doors complete all as specified and directed by Engr-in-charge. |
| 79 | S&F in replacement of Double Decker Cable Trolley having Multiple Cable Clamping Width up to 150 mm adjustable variant made up of Mild steel, suitable for I Beam of size upto 100mm, powder-coated for corrosion resistance, heavy-duty bearing/polymer wheels designed for smooth movement along the track, load capacity min 30kg for EOT crane including cable dressing properly, steel chain complete all as specified and directed by Engr-in-charge. Note : (i) Contractor should visit site before quoting. Necessary safetymeasures to be taken by the contractor while dismantling and fixing the same as the work site is at the height of approx 20 ft. (ii) Any damage to govt property while exceuting the work is to be make good by the contractor at no extra cost. (iii) Contractor should provide skilled labour while executing the job.(iv) The cost of Scaffolding arrangement/Ladders/ safetybelts/ Lifting Jacks and T & P used while working in the Crane will be beared by the contractor itself. |
| 80 | M&L for checking, inspecting and dismantling and removing of unserviceable cross travel mild steel wheel by necessary jack up arrangements including all accessories like Top plate, wheel shaft, bearing housing, bearings drive gear and wheel and connected accessories complete of EOT cranes capacity 0.5 ton to 5 ton. Cleaning all accessories to check the condition complete all as specified and directed by Engr-in-charge. |
| 81 | All as per Item Ser No 80.00 above but of EOT Crane capacity 10 to 20 Ton cranes |
| 82 | All as per Item Ser No 80.00 above but of EOT Crane capacity 50 Ton cranes Please Enable Macros to View BoQ information |
| 83 | All as per Item Ser No 80.00 above but of EOT Crane capacity 50 Ton cranes Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender