Tender For Annual Plan-Dp Ekm - S01042/27 -Karukutty Division - Kangappadam Lift Irrigation Project Installation Of Motor And Pipe -Sitc Of 40 Hp Motor Pump Set Suction And Delivery Pipe And Electrification Inkangappadam Li Scheme In Ward 4 Kunnukara
Tender Overview
Project Description
Tender for Annual Plan-Dp Ekm - S01042/27 -Karukutty Division - Kangappadam Lift Irrigation Project Installation Of Motor And Pipe -Sitc Of 40 Hp Motor Pump Set Suction And Delivery Pipe And Electrification Inkangappadam Li Scheme In Ward 4 Kunnukara Gp-General Electrical Work
BOQ
| Sl. No. | Item Description |
| 1 | SITC of 40 HP motor pump set and Electrification |
| 2 | OD254056/2026-2027:Supply of 40 HP Motor pump-set consisting End suction pump model Kirloskar make DBxe 125-32 , pump size 150mm suc x100 mm del , Cast Iron construction with CI impeller, CS Shaft capable of discharging 67 Lps against head of 32 mtrs with an efficiency of 83 % Gland packed directly coupled with 40 HP squirrel cage induction motor 1450 RPM ,TEFC,IE2 motor , 3 phase , 415 V, 50 Hz AC supply , mounted on common base plate, flexible coupling with coupling pulley, bolts & nut, foundation bolts and nuts, coupling guard etc. from the original manufacturer ( Kirloskar or equivalent make ) |
| 3 | OD254055/2026-2027:Charges for installation, testing and commissioning of 40 HP Motor pump-set consisting End suction pump model Kirloskar make DBxe 125-32 , pump size 150 x100 mm, mounted on common base plate, flexible coupling with coupling pulley, bolts & nut, foundation bolts and nuts, coupling guard etc. on existing cc foundation. |
| 4 | OD246536/2026-2027:Supply, conveyance and installation of 1 HP Mono block type Vaccum pumpset suitable for working AC 3duty, 3 phase, 415 V, 50 Hz supply, complete with pipe connections etc. Kirloskar make KV 20 orequivalent make and giving connections and trail run etc. |
| 5 | OD254123/2026-2027:Supply, conveying & fixing 200 mm dia ISI marked Tata / Jindal /equivalent make GI pipe having sheet thickness 6.00 mm and cutting in to required length, facing the cutting edges and supply and providing GI flanges having 12 mm thickness and minimum 75 mm depth on both ends of every 2 mtr or nearest long , including conveyance charges to pump house and labor charges for loading, unloading, fixing on alignment for suction/delivery side pipe using suitable rubber packing etc. painting with two coats of synthetic enamel paint over a coat of red oxide primmer etc complete. |
| 6 | OD254385/2026-2027:Supply, conveying & fixing 150 mm dia ISI marked Tata/ Jindal /equivalent make MS pipe having sheet thickness 6.35 mm and cutting in to required length, facing the cutting edges and supply and providing MS flanges having 12 mm thickness and minimum 75 mm depth on both ends of every 2 mtr or nearest long , including conveyance charges to pumphouse and labor charges for loading, unloading, fixing on alignment for suction/delivery side pipe using suitable rubber packing etc. painting with two coats of synthetic enamel paint over a coat of red oxide primmer etc. complete. |
| 7 | OD254121/2026-2027:Supply, conveying & fixing 200 mm dia ISI marked Tata / Jindal /equivalent make GI pipe 0.60 meter long bend having sheet thickness 6.00 mm and cutting in to required length, facing the cutting edges and supply and providing 2 nos GI flanges having 12 mm thickness and minimum 75 mm depth on both ends including conveyance charges, labor charges for loading, unloading, fixing on alignment for suction/delivery side pipe using suitable rubber packing etc. painting with two coats of synthetic enamel paint over a coat of red oxide primmer etc complete. |
| 8 | OD254122/2026-2027:Supply, conveying & fixing 200 mm x 150 mm dia ISI marked Tata / Jindal /equivalent make GI pipe Reducer 0.30 meter having sheet thickness 6.00 mm and cutting in to required length, facing the cutting edges and supply and providing 2 nos GI flanges having 12 mm thickness and minimum 75 mm depth on both ends including conveyance charges to pump house and labor charges for loading, unloading, fixing on alignment for suction/delivery side pipe using suitable rubber packing etc. painting with two coats of synthetic enamel paint over a coat of red oxide primmer etc complete. |
| 9 | OD254384/2026-2027:Supply, conveying & fixing 0.60mtr or nearest long MS Bend consisting 150 mm dia ISI marked Tata/ Jindal /equivalent make MS pipe having sheet thickness 6.35 mm and cutting in to required length, facing the cutting edges and supply and providing MS flanges having 12 mm thickness and minimum 75 mm depth on both ends including conveyance charges to pumphouse and labor charges for loading, unloading, fixing on alignment for suction/delivery side pipe using suitable rubber packing etc. painting with two coats of synthetic enamel paint over a coat of red oxide primmer etc complete. |
| 10 | OD255309/2026-2027:Supply, conveyance and erection of 150 mm ISI marked Cast Iron flanged type Rising spindle Sluice valve as per IS: 14846 PN 1.0 with CI body, bronze wedge rings seating's and SS spindle and fixing the same in position using necessary, gland packing , rubber packing ,bolt nut and washer etc. |
| 11 | OD255137/2026-2027:Supply, conveyance and erection of 150 mm ISI marked Cast Iron flanged type Check Valve / Non Return valve as per IS: 5312 PN 1.6 with Bronze body and wedge with stainless steel spindle , bronze seating ring , gland packing and rubber gaskets etc. and fixing the same in position using necessary gasket packing ,rubber packing ,bolt nut and washer etc. |
| 12 | OD246556/2026-2027:Supply, conveying & fixing 150 mm PVC Tail end piece with flange having 12 mm thickness and minimum 63 mm depth and fixing on alignment for suction/delivery side pipe using suitable rubber packing , cement solvent etc |
| 13 | OD246537/2026-2027:S&F 25mm Gun metal full way wheel valve . |
| 14 | OD246545/2026-2027:S&F 25 mm medium class GI Pipe with GI specials such as coupler, union ,bend & T etc. for connection to the Vacuum pump set . |
| 15 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 16 | OD246523/2026-2027:Charges for chipping the existing RCC slab using suitable Jacky hammer/ breaker including all hire and labor charges of tools and plants including suitable capacity Diesel generator set with fuel etc. complete |
| 17 | 14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. |
| 18 | OD246526/2026-2027:Reinforcement for R.C.C works, bend tied and placed in position (plain grill requiring bend cold) using torsteel . |
| 19 | 14.11:Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels. |
| 20 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels |
| 21 | OD246543/2026-2027:Supply and providing metallic support for suction/delivery side MS/GI pipe using suitable Channel/ Angle/ flat / square or rectangular pipe welded together and painting two coats of synthetic enamel paint over a coat of red oxide primer . |
| 22 | 90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point |
| 23 | 90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points |
| 24 | 90.3.18.1:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.25 mm dia with HG company fabricated clamps |
| 25 | 90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture |
| 26 | 90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 27 | 90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm |
| 28 | 1.21.4:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm |
| 29 | 1.21.5:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.50 mm |
| 30 | 90.6.4.51:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 1 Run |
| 31 | 1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm |
| 32 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 33 | 1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm |
| 34 | 1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm |
| 35 | OD255047/2026-2027:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.25.00 sq.mm 3 Run |
| 36 | OD255000/2026-2027:Supply and drawing 1100 V grade Heat Resistant Flame Retardant HRFR PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.35.00 sq.mm 3 Run |
| 37 | 90.14.28.2:S & F Motor starters of the following ratingsThree phase DOL starters for 0.25HP to 7.5 HP motor |
| 38 | OD254449/2026-2027:Supply, conveyance , installation , testing and commissioning of Heavy duty application Auto Transformer Starter suitable for 40 HP squirrel cage induction motor including floor /wall mounting stand , required level good quality transformer oil , over load relay, single phasing preventer etc. complete and giving connections Make. UNILEC/KAVERI/BEE or equivalent make |
| 39 | 90.14.24.23:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.10 KVAr, 3 phase, 440 V, delta connected, standard duty Metalised Poly Propylene Capacitor, Box Type, suitable for direct connection to motors. |
| 40 | 90.14.24.1:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.1 KVAr, 3 phase, 440 V, delta connected Metalised Poly Propylene Capacitor, Cylinderical Type, suitable for direct connection to motors. |
| 41 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 42 | 5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 43 | 90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG) |
| 44 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 45 | 90.16.1.6:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required6.00 mm copper conductor (4 SWG) |
| 46 | 90.16.2.3:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.32 mm dia G.I pipe ( medium class) |
| 47 | 90.16.3.9:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip |
| 48 | 90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG) |
| 49 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 50 | 90.16.5.6:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.6. mm ( 4 SWG) |
| 51 | OD246539/2026-2027:Supply and fixing 25x6 mm brass bolt, nut and washer |
| 52 | OD246534/2026-2027:Supply and fixing 12x3 mm brass bolt, nut and washer |
| 53 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 54 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 55 | 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 56 | 2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door |
| 57 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 58 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 59 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 60 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 61 | 90.12.24.2:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.4 sq mm |
| 62 | 90.12.24.3:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.6 Sq mm |
| 63 | 90.12.24.4:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm |
| 64 | 90.12.24.6:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.25 sq mm |
| 65 | 90.12.24.7:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.35 sq mm |
| 66 | 90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) |
| 67 | 90.14.2.2:Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc. |
| 68 | 90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet |
| 69 | 90.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC) |
| 70 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 71 | 90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required. |
| 72 | 90.14.7:Supply and providing copper earth bus in the panel board |
| 73 | 90.14.10.6:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.125A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC |
| 74 | 2.1.1:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N |
| 75 | 2.1.4:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.125 Amp TP & N |
| 76 | OD246560/2026-2027:Supply and fixing 125A On Load change Over Switch on existing cubicle type switch board and giving connections. |
| 77 | OD246538/2026-2027:S & F 63 A ,415 V , 50 Hz, 50 Ka , Motor Protection Circuit Breaker suitable for 40 Hp motor pump set having Thermal release range 45 - 63A and Instantaneous Trip current 819 A L and T make Cat No. ST41922OOOO or equivalent make with Short circuit and over load protection |
| 78 | OD246557/2026-2027:S& F Three phase multi function meters to read V, A ,F and PF accuracy class 1 on existing panel and giving connections. L & T make Cat. No: WL 4110 OOOO or equivalent make . |
| 79 | OD246541/2026-2027:S & F LED phase indicators for all voltage ranges - Red or Yellow Color |
| 80 | OD246550/2026-2027:S & F LED phase indicators for all voltage ranges - Blue Color |
| 81 | OD246527/2026-2027:Supply and fixing 20 A Fuse unit with HRC link on existing board using suitable bolt , nut and giving connections |
| 82 | 90.14.11.1:MCCB AccessoriesSupply and fixing one number earth fault Relay up to 100A with CBCT. |
| 83 | 90.14.11.12:MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A. |
| 84 | 90.14.11.13:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A |
| 85 | OD246528/2026-2027:Supply and fixing copper spreader terminal suitable for 80 /100 / 125 A MCCB |
| 86 | OD246524/2026-2027:Supply and fixing Resin cast 100/5 A , 5VA , 1 accuracy class metering CT on existing board and giving connections. |
| 87 | OD246549/2026-2027:S & F Enameled Danger Notice Board of size 250 x 200 mm. with inscriptions ( both in English and Malayalam) and conventional Skull and Bone in Red color. |
| 88 | OD246525/2026-2027:Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required 2.50 cm, 4 cm or 5 cm height |
| 89 | OD246530/2026-2027:Supply and providing First Aid Chart ( Shock Treatment Chart ) PVC laminated /duly framed and placed in a conspicuous location for clear vision. |
| 90 | OD255092/2026-2027:Supply and providing 2.0 mm thick , 3.3 kV , Synthetic elastomeric fire retardant insulating mat in position |
| 91 | OD255093/2026-2027:Supply and providing 5 Kg Dry Chemical type Fire extinguisher with wall clamp |
| 92 | OD255102/2026-2027:Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required. |
| 93 | OD246554/2026-2027:Supply and fixing 160 A Fuse unit with HRC link on existing board using suitable bolt , nut and giving connections |
| 94 | OD246546/2026-2027:Supply and fixing 63 A 2 way neutral link on SMC or DMC base and giving connections |
| 95 | OD246542/2026-2027:Supply and providing 8/10 mm SS hook Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender