Tender For Arm Of Residential And Non Residential Buildings At 29 Scg Nsg, Kolkata For The Year 2026-27 (Sh: Maintenance Of Power Cables And Street Lights,Solar Power Plant Etc)
Tender Value
14.15 Lakhs
Estimated cost
Bid Submission
27 Nov 2026
7 days left
EMD
28303
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas South → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Arm Of Residential And Non Residential Buildings At 29 Scg Nsg, Kolkata For The Year 2026-27 (Sh: Maintenance Of Power Cables And Street Lights,Solar Power Plant Etc)
BOQ
| Sl. No. | Item Description |
| 1 | Rewinding of following size ceiling fan/wall fan /Exhaust Fan of all types with super enameled copper wire and over hauling including minor repairs lubricating of ball bearings & bush bearing, screws etc. & testing for original speed and consumption with guarantee for one year. (Rate are less of U/S copper wire i.e Dismantal material will not be taken back by NSG)a) 1200/1400 mm Sweep ceiling fan |
| 2 | Rewinding of following size ceiling fan/wall fan /Exhaust Fan of all types with super enameled copper wire and over hauling including minor repairs lubricating of ball bearings & bush bearing, screws etc. & testing for original speed and consumption with guarantee for one year. (Rate are less of U/S copper wire i.e Dismantal material will not be taken back by NSG)b) Wall Fan upto 400 mm |
| 3 | Rewinding of following size ceiling fan/wall fan /Exhaust Fan of all types with super enameled copper wire and over hauling including minor repairs lubricating of ball bearings & bush bearing, screws etc. & testing for original speed and consumption with guarantee for one year. (Rate are less of U/S copper wire i.e Dismantal material will not be taken back by NSG)c) Exhaust fan upto 380 mm |
| 4 | Rewinding of following size ceiling fan/wall fan /Exhaust Fan of all types with super enameled copper wire and over hauling including minor repairs lubricating of ball bearings & bush bearing, screws etc. & testing for original speed and consumption with guarantee for one year. (Rate are less of U/S copper wire i.e Dismantal material will not be taken back by NSG)d) 450 mm exhaust fan. |
| 5 | Replace of bearing suitable for following size ceiling fan/wall fan /Exhaust Fan TATA/SKF/NBC( Rate are less of U/S material i.e Dismantal material will not be taken back by NSG)a)1200/1400 mm Sweep ceiling fan |
| 6 | Replace of bearing suitable for following size ceiling fan/wall fan /Exhaust Fan TATA/SKF/NBC( Rate are less of U/S material i.e Dismantal material will not be taken back by NSG)b)Wall Fan upto 400 mm |
| 7 | Replace of bearing suitable for following size ceiling fan/wall fan /Exhaust Fan TATA/SKF/NBC( Rate are less of U/S material i.e Dismantal material will not be taken back by NSG) c)Exhaust fan upto 380 mm |
| 8 | Replace of bearing suitable for following size ceiling fan/wall fan /Exhaust Fan TATA/SKF/NBC( Rate are less of U/S material i.e Dismantal material will not be taken back by NSG)d)450 mm exhaust fan. |
| 9 | Laying of one number PVC insulated and PVC seathed/XLPE power cable of 1.1 KV 2025 grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective coveringa) Upto 35 sq mm |
| 10 | Laying of one number PVC insulated and PVC seathed/XLPE power cable of 1.1 KV 2025 grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective coveringb) Above 35 sq mm and Upto 95 sq. mm |
| 11 | Laying of one number PVC insulated and PVC seathed/XLPE power cable of 1.1 KV 2025 grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective coveringc) Above 95 sq. mm and upto 185 sq. mm |
| 12 | Laying of one number PVC insulated and PVC seathed/XLPE power cable of 1.1 KV 2025 grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective coveringd) Above 185 sq. mm and upto 400 sq. mm |
| 13 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.a) 2 X 25 sq. mm |
| 14 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.b) 3.5 X 50 sq. mm |
| 15 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.c) 3.5 X 120 sq. mm |
| 16 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.d) 3.5 X 185 sq. mm |
| 17 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.e) 3.5 X 240 sq. mm |
| 18 | Supply of UG Power Cables,Stranded XLPE Insulated, Cores Laid Up, PVC Innersheathed, Armoured Extruded PVC Type ST2 Outer Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments. Make Havells/PolyCab/finolex/universali)2 X 25 SQ M |
| 19 | Supply of UG Power Cables,Stranded XLPE Insulated, Cores Laid Up, PVC Innersheathed, Armoured Extruded PVC Type ST2 Outer Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments. Make Havells/PolyCab/finolex/universal ii)3.5 X 120 SQ M |
| 20 | Finding the pin point location of fault /faults in the existing various UG cables Aluminium Armoured cables (25 sqmm to 240 SqMM) tracing the different length ( 2000 Mtr) length approx)using Surge wave tester i/c Transporatation of equipment to 29 SCG NSG campus and return back. (Minimum 04 days) as per direction of Engineer-in-charge. |
| 21 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release, Fixed Thermal Fixed magnetic and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, lcs=100% Icu and Operational Voltage415 V etc as required. (Rates taken After deducting dismental material)4 pole MCCB 32 A, 16KA Sentron 3 VA make Seimens or equivalent make L&T,ABB,Schneider, Legrand, Seimens |
| 22 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release, Fixed Thermal Fixed magnetic and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, lcs=100% Icu and Operational Voltage415 V etc as required. (Rates taken After deducting dismental material)4 pole MCCB 100 A ,25KA Sentron 3 VA make Seimens or equivalent make L&T,ABB,Schneider, Legrand, Seimens |
| 23 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release, Fixed Thermal Fixed magnetic and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, lcs=100% Icu and Operational Voltage415 V etc as required. (Rates taken After deducting dismental material)4 pole MCCB 160 A ,25 KA Sentron 3 VA make Seimens or equivalent make L&T, ABB, Schneider, Legrand, Seimens |
| 24 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release, Fixed Thermal Fixed magnetic and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, lcs=100% Icu and Operational Voltage415 V etc as required. (Rates taken After deducting dismental material)4 pole MCCB 250 A ,36 KA Sentron 3VA make Seimens or equivalent make L&T,ABB,Schneider ,Legrand,Seimens |
| 25 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release, Fixed Thermal Fixed magnetic and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, lcs=100% Icu and Operational Voltage415 V etc as required. (Rates taken After deducting dismental material)4 pole MCCB 400 A ,36 KA Sentron 3VA make Seimens or equivalent make - L&T,ABB,Schneider, Legrand, Seimens |
| 26 | Supplying, installation, testing and commissioning of 60 Watt LED street light luminaire made up of die-cast aluminium housing, with IP66 degree of protection, complete with the driver, LEDs with optical lens, toughened glass cover, etc. The luminaire driver should have an operating voltage range of 140-270 Volt,5700 K, a mechanical impact resistance rating of |k>=07. surge protection of = 10KV, PFz 0.90 and minimum system luminous efficacy of 110lm/W. The luminaire shall be designed for a system life of 50,000 hours and suitable for mounting on pole bracket up to outer dia 50 mm, including installation on existing street light pole bracket connections and earthing etc., as required. LM 79 and LM 80 reports need to be submitted from a NABL/UL accredited lab to verify the above parameters. The contractor shall provide a warranty for the above-LED light fixtures for five years. (Approved Manufacturers: Phillips, Havell, Lighting Technology, Bajaj, CG, Wipro, trilux )(Rates analysed after deducting the retreiavable material) |
| 27 | Supplying, installation, testing and commissioning of 120 Watt LED street light luminaire made up of die-cast aluminium housing, toughned glass with IP66 degree of protection, complete with the driver, LEDs with optical lens, toughened glass cover, etc. The luminaire driver should have an operating voltage range of 140-270 Volt, a mechanical impact resistance rating of k>=07.4 KV , 4 KV in built surge protection out door surge protection of = 10KV, PF2 0.90 and minimum system luminous efficacy of 110 Im/W. The luminaire shall be designed for a system life of 50,000 hours and suitable for mounting on pole bracket up to outer dia 50 mm, including installation on existing street light pole bracket connections and earthing etc., as required. LM 79 and LM 80 reports need to be submitted from a NABL/UL accredited lab to verify the above parameters. The contractor shall provide a warranty for the above-LED light fixtures for five years. (Approved Manufacturers: Phillips, Havell, Lighting Technology, Bajaj, CG, Wipro, trilux )(rates quoted after deducting the dismental material Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysNov 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender