Agriculture Government Departments Closing in 19 days TDR #58608407

Tender For Renovation Of Building (2),(3),(4),And (10) For The Proposed Cbfd Building At District Veterinary Campus In Kanchipuram District

Issued by Government Departments · Kanchipuram, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
10 Dec 2026
19 days left
EMD
28000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kanchipuram → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Renovation Of Building (2),(3),(4),And (10) For The Proposed Cbfd Building At District Veterinary Campus In Kanchipuram District

BOQ

Name of Work:- Renovation of Building (2),(3),(4),and (10) for the proposed CBFD Building at District Veterinary Campus in Kanchipuram District
Sl. No. Item Description
1Clean removals of Cement plaster from walls as directed by the departmental officers.
2Dismantling, removing and carefully stacking press tiles with weathering course etc, complete as directed by the departmental officers
3Dismantling the Existing Flat & pan tiles or Mangalore tile over flat tiles, with out roof timbers etc., complete..
4Dismantling the damaged floor finish and dadooing walls in cement mortar with mosaic tiles / Glazed tiles/ cuddapah slab and clearing away with carefully stacking the material useful for reuse for any thickness etc., complete complying with standard specification and as directed by the Departmental Officer.
5Dismantling the damaged Doors and windows including removal of frames, Hinges, fastenings and fixing the same including necessary alterations etc., complete complying with standard specification and as directed by the Departmental officers.
6Earth work open excavation in all soils and sub soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring, shuttering, bailing out water wherever necessary and depositiong the excavated earthe with a lead of 10m within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification
7Supplying and filling in foundation and basement with M - Sand in layers of not more than 15cm thick well watered, rammed and consolidated etc., complete as per standard specification.
8Refilling with excavated earth other than sand with an initial head load of 100 mts. And depositing the earth as shown by the departmental officers in layers of not more than 15cm thick well rammed, watered and consolidated etc., complete complying with standard specification
9Plain Cement concrete 1:5:10 (One cement five M sand and ten broken Machine crushed stone jelly) using HBG Machine crushed stone jelly of size 40mm gauge for founding and basement including de- watering if found necessary and laid in layers of not more than 15cms thick etc., complete
10Plain Cement concrete 1:2:4 (One cement Two M sand and four broken Machine crushed stone jelly) using HBG Machine crushed stone jelly of size 10-12 mm gauge for founding and basement including de- watering if found necessary and laid in layers of not more than 15cms thick etc., complete complying with standard specification and as directed by the departmental officers.
11Brick work in following Cement Mortar using best quality of Second class ground moulded chamber burnt bricks 9\\"x4-3/8\\"x2-3/4\\" for foundation and basement including curing etc, complete complying with standard specification. (For Foundation and Basement
12Plastering the walls with Cement Mortar 1:5 - 12 mm thick using the M sand including curing and finishing neatly complying with standard specification and as directed by the departmental officers etc. complete.
13Special ceiling plastering and finishing all RCC exposed surfaces such as RCC slabs, sunshades, canopies, stair case steps, landing slabs etc with CM 1:3 (One cement and three M sand) 10mm thick including hacking the surfaces and providing necessary CM nosing, beading as per size specified wherever necessary using the same mix etc., complete complying with standard specification and as directed by the Departmental Officer.
14Fabricating supplying and erecting the Pre-engineered steel building structure using Galvanised structural steel sections, conforming to Grade 50 with yield strength of 345MPa baseplate, Sag Rods, struts including cleats to receive 'Z' and 'C' purlins, cutting, drilling holes, welding, grinding fixing the members with nessary bolts nuts, anchor bolt of approved quality, hoisting, aligning and placing the 'I' sections in position as per the design got approved from the department, fixing purlins with Sag Rods, supporting the purlinsfrom the beams on both sides. The welding should be done with submerged arc welding to full length. The rate inclusive of the cost of painting the memebers with one coat of primer of Zinc chromite and enamel paint etc., complete complying with standard specification and as directed by the departmental officers, etc., complete. (Observed Data)
15Weathering course-using Concrete broken brick jelly 20 mm gauge in pure slacked lime (No sand to be used) over RCC roof slab. The proportion of broken brick jelly to slaked lime being 32:12½ cft well beaten by wooden beaters for giving required slope and thickness required etc complete complying with standard specifications and as directed by Departmental Officers. For Ground Floor
16Finishing the top of roof with one course of machine pressed tiles of size 23x23x2cm of approved quality laid in CM 1:3 (one cement and three sand) mixed with 2% of water proofing compound by weight of cement used and pointed with the same oiled mortar including mixing of red oxide etc complete complying with standard specifications and as directed by Departmental Officers.Pressed tiles 23cm x 23cm x 20mm
17Painting the walls with Two coats with first class quality Plastic Emulsion paint of approved colour over a priming coat including thorough scraping, clean removal of dirt. The rate includes cost of brushes, sand paper, plaster of parries, putty wherever required and neat finishing etc., complete complying with standard specification and as directed by the Departmental Officer (the colour and quality should be got approved by the Executive Engineer before use)
18Supply and fixing PVC rain water down fall pipes of 110 mm dia size 4 Kg/cm2 with necessary shoes, specials, clamps, bends, cowl, screws, nails, teakwood block, etc., complete complying with standard specification and as directed by the Departmental officers.
19Supplying and fixing of rolling shutters with ISI mark shall be of pull and push type made out of 18/Gauge x3’’ lathe sections which consists of five main parts such as curtain, lock plate, guide channels rollers and hood cover. These five main parts are made out of special components detailed below; Curtain; Shall be of 18/Gx3' lath sections cut to required size and filled with heavy cast iron/ M.S. Clips for 8'0\\"[2.45m] high rolling shutter lathe sections provided shall be not less than 37 numbers. Lock Plate; Shall be 10gaue M.S.Sheet reinforced with 40mmx 6mm M.S angles at the bottom and fitted with heavy latches of 12mm thick locking arrangements on either sides. There should be one handle on either side Guide channel; Pressed guide channels shall be of 10 gauge M.S.Sheet and attached to the side brackets with 20mm square bar. Side brackets shall be of 10 Gauge angle M.S.Plate and cost iron 'U' clamps shall be reveted to the side brackets Roller; Shall be of heavy cast iron pullies fitted with heavy duty C' Class 40mm steel pipes and high tensile high carbon coil springs-2 springs shall be supplied. Supplying and fixing of Hood Cover; Shall be of 0.9mm CRCA sheet reinforced with 25mm x 25mm x 3mm M.S. angle or gate channel. The rolling shutter in addition to the above should have pulling hook and shall be coated with heavy coat of zinc chromite primer. The above specifications for various components of rolling shutter shall be invariably followed and verified with the rolling shutters supplied by the firms at site. If the rolling shutters supplied do not confirm to the above specifications, the concerned firms should be asked to replace the shutter or supply the missing components Rolling shutter (18 gauge) Gear Operated Type
20Fabricating and supplying and erecting the main gate / Wicket Gate / grill with necessary bolts and nuts including with one coat of red oxide primer and zinc chromate etc., complete complying with standard specification and an directed by the departmental officers.
21Providing UPVC (Un-Plasticized Polyvinyl Chloride) WindowWindow: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mmx55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25x24x25mm steel reinforcement with a thickness of 1mm to have dimensional stablilty. The sash should be of 60x102mm. The mulilion should be of 60x74mm. The profiles should have co-extruded seals.Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside.Glazing: The window system should be glazed with 5mm plain float glass/6mm bison lamInstallation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug.
22Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mmx55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25x24x25mm steel reinforcement with a thickness of 1mm to have dimensional stablilty. The sash should be of 60x102mm. The mulilion should be of 60x74mm. The profiles should have co-extruded seals.Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside.Glazing: The window system should be glazed with 5mm plain float glass/6mm bison amInstallation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug.
23Chemical treatment for Building roof with grouting and water proof coating two coats. Application of leak proof arrangements having the following steps : 1. Rust removal by applying Forsco rust removal chemical 2. Plaster bonding chemical, (Forsco SBR) 3. Finishing the roof plaster using Forsco NITO bond 4. Applying salt resistance chemical (Forsco salt resistance paste)
24Supplying, laying and joining UPVC pipes of approved quality and best variety conforming to ISS with ISI mark, of the following size External above ground level up to 4 M hight laid properly to alignment including cutting, threading and fixing the required UPVC specials but excluding the cost of such specials and fixing to the wall with necessary TW plugs, clamps and screws, making holes on the wall or drilling holes in the roof and making good dismantled portion to original condition with necessary brick work, concrete and plastering wherever necessary with necessary scaffolding charges etc., complete. (25 mm)
25Supplying and fixing in position first quality and approved variety gun metal Gate valve (Heavy type)/ Wheel Valve (Heavy Duty) with ISI Mark of approved quality of the following dia including cost of shellac, thread, labour charges for cutting, threading, fixing in position etc., complete complying with standard specification and as directed by the Departmental Officer for both internal and external water supply arrangements. (Gate Valve-25 mm)
26Supplying and fixing in position of the following UPVC specials of heavy type and approved quality and good variety excluding fixing charges complying with standard specification. Fixing charges included in the pipe laying work (The UPVC specials should be got approved by the Executive Engineer concerned before use on works).Elbow 25mm dia
27Supplying and fixing in position of the following UPVC specials Tee 25mm dia
28Supplying and fixing in position of the following UPVC specials Union 25mm dia
29Supplying and fixing in position of the following UPVC specials Bend 25mm dia
30Supplying and fixing in position of the following UPVC specials Coupler 25mm dia
31Wiring with 2 x 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A FT switch and making good of the concealed portion with suitable colour for PVC concealed light / fan Point (for electronic regulator) (5 points per coil)(SD 25)
32Wiring with 2x4 sqmm(56/0.3) PVC insulated SC unsheathed Cu.Conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories, in flush with wall, with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet for 15 A 3 pin non inter locking Wall socket with 15A Flush type switch with continuous earth wire connection of 14 SWG TC wire , and making good of the concealed portion, with suitable colour for concealed power plug point (SD 40)
33Supply and fixing of single box type 4'40 W flu fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting (SD 88)
34Supply and fixing of 4'40 W twin street light flu. fitting complete With copper choke and condensor with 19mm dia GI pipe (Class 'B') with 1 No. 19mm GI Bend complete on the existing post / wall With 16 A aerial fuse unit on MS plate with PVC unsheathed Cu. leads, with MS clarnps and aluminium painting with Flu. Tubes (SD 94)
35Supply and fixing of 1200 mm (48\\") AC ceiling fan complete with stepped electronic 300W regulator with 300mm down rod on the existing clamp. (SD 110)
36POLYURETHANE FOAM THERMAL INSULATION PANELS Providing and Fixing of polyurethane foam as Internal Partition Wall Thermal insulation panels or Sandwich insulated panels wihboth internal and external 0.50mm total coated thickness repainted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free , high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc& accessories such as screws, fastners, sealants etc for fixing the panel etc., complete complying with standard specification.as per SCR 2025 page 57 (W0368) for roof & Wall (30mm thick PUF externnal Partition wall panel )
37Old Terrace Screed Repair with UV Resistant Hybrid PU Waterproof coating above 500 Sq.m - Providing and Applying high strength, hybrid polyurethane Waterproofing coating which is two component, cold applied, water based acrylic and UV resistant water proofing treatment to the Existing Roof screed surface applied @ 1.6 L/m2 in 3 coats to achieve 1mm DFT, having tensile strength with 45 gsm glass fibre mesh 10N/mm2 , Elongation ≥ 200%, confirming to ASTM D2370; Abrasion resistance 15mg confirming to ASTM D 4060 and Crack bridging ability up to 3 mm, including surface preparation, ensure surface in SSD condition for first coat and spreading 45 gsm glass fibre mesh of 2.5 mm x 2.5 mm sandwiched between the first and second coat completely as per specification. The finished cost to include surface preparation, making coving at Junction, treatment of cracks completely as per specification. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58608407
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 10-12-2026
Authority
Authority Name Tamil Nadu Livestock Development Agency
Work Description Tender for Renovation Of Building (2),(3),(4),And (10) For The Proposed Cbfd Building At District Veterinary Campus In Kanchipuram District
Basic Detail
Tender No 2026/91
Bidding Type Tender
Location
City Kanchipuram
State Tamil Nadu
Key Dates
Publish Date 19 Nov 2026
Submission Date 10 Dec 2026
Open Date 10 Dec 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 28000
Exemption Available
Document List
0f60417d-9d48-4b7c-b97c-e99b6307e551.html
90KPM.pdf
BOQ_873869.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Dec 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

0f60417d-9d48-4b7c-b97c-e99b6307e551.html

pdf

90KPM.pdf

xls

BOQ_873869.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender