Tender For maintenance Of electrical installation In Nrb At Chandigarh (Repair/Replacement Of Burnt Out Electrical Accessories In Various Schools, Buildings, Dispensaries, Creches Under maintenance Booth Sector-27, Under Jurisdiction Of Sdee-6, Secto
Tender Overview
Project Description
Tender for maintenance Of electrical installation In Nrb At Chandigarh (Repair/Replacement Of Burnt Out Electrical Accessories In Various Schools, Buildings, Dispensaries, Creches Under maintenance Booth Sector-27, Under Jurisdiction Of Sdee-6, Sector-9, Chandigarh) (E.I Work).
BOQ
| Sl. No. | Item Description |
| 1 | DSR Item No. 1.17Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 2 | 3 x 1.5 sq. mm |
| 3 | 3 x 2.5 sq. mm |
| 4 | DSR item No.1.23Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 5 | 5/6 amps switch |
| 6 | 2 way 5/6 A. switch |
| 7 | 15/16 amps switch |
| 8 | 3 Pin 5/6 A. socket outlet |
| 9 | 6 Pin 15/16 A. socket outlet |
| 10 | Bell push |
| 11 | DSR item No.1.24Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 12 | 5/6 amps switch |
| 13 | 15/16 amps switch |
| 14 | 2 way 5/6 A. switch |
| 15 | 3 Pin 5/6 A. socket outlet |
| 16 | 6 pin 15/16 amps socket |
| 17 | Bell push |
| 18 | DSR Item No.1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 19 | DSR Item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 20 | Single pole |
| 21 | Double pole |
| 22 | Triple pole and neutral |
| 23 | DSR Item No. 2.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 24 | DSR Item No. 8.13LED Street light fixture, powder coated pressure die cast aluminum body (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, (As per Completed Item on 7 of DNIT ) |
| 25 | 50 Watt |
| 26 | Supply and Erection of B.L. Holder of make Anchor Panta / Havells Reo/ Gold Medal Essenza ISI marked on existing Jn. Box / Wooden block including making connection etc as required. |
| 27 | Supply and Erection of electronic step type socket type fan regulator in existing B.L. Sheet including making connection and petty material reqd. to complete the job. The fan regulator should be of Anchor Panta / Havells Reo/ Gold Medal Essenza make only |
| 28 | Supply & Erection of 3 mm thick white glazed bakelite sheet on existing M.S. box. The job includes the cost of sheet and making holes & cutting and fixing with screws as required to complete the job. The make should be Super Hylam / Formica / GreenLam only. |
| 29 | Supply, Erection, Testing and commissioning of the following accessories after dismantling the burnt out/ defective accessories with the help of ladder if required which shall be arranged by the firm at his own cost. The job includes making connections with copper wire and petty material etc. The work should be done to the entire satisfaction of EIC. |
| 30 | S/E of LED Driver suitable for existing 2’x2’ LED panel type fitting. The Driver should be same make of existing fitting. |
| 31 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, (As per Completed Item on 12 of DNIT ) |
| 32 | Size 12” Sweep 900 RPM with louver of Havells make Turbo Force SP / Orient make Industrial Heavy Duty / Crompton make EXHD 300-6-1/ Bajaj make Supreme DLX/ Usha make Turbo HDEF only. |
| 33 | DSR Item No. 8.16.3LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy ≥120 and <135 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, (As per Completed Item on 13 of DNIT ) |
| 34 | 100 Watt |
| 35 | DSR ITEM NO. LED 8.9.5Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,(As per Completed Item on 14 of DNIT ) |
| 36 | 18-22 watt |
| 37 | S/E of 18Watt./20Watt. 4’ long LED tube rod made of polycarbonate material should be installed in existing LED fitting base only. The make of LED tube rod should be same as that of existing LED fitting. The job includes cost of carriage, erection, testing and commissioning of the LED tube rod etc. as required to complete the job to the entire satisfaction of Engineer In Charge. Specification of LED tube rod: |
| 38 | Supply & erection of fresh air fan high speed motor with copper wound 10” sweep with louver and plastic body complete with high speed motor, blades, epoxy powder coated of Havells make Ventiliar DX White / Orient make Ventilator / Crompton make Brisk Air/ Bajaj make 70049 250mm sweep only. (As per Completed Item on 16 of DNIT ) |
| 39 | DSR Item No. 8.6LED Panel light 4x1 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 4x1 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, (As per Completed Item on 17 of DNIT ) |
| 40 | 36 Watt |
| 41 | DSR ITEM NO. 8.7LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, (As per Completed Item on 18 of DNIT ) |
| 42 | 36 watt |
| 43 | Supply and erection of 5/7/9 Watt. LED lamp suitable for existing fitting. The LED lamp should be of Philips / Osram / Bajaj / Wipro / Twinkle make only. The job includes the cost of all other petty material etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. The color and wattage of lamp should be as selected by the occupant. |
| 44 | S/E of PVC Batton of following sizes. The Batton should be fixed on the wall with help of PVC rawl plug etc. to the entire satisfaction of EIC. |
| 45 | Size 1” |
| 46 | Size ¾” |
| 47 | DSR Item No. 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 48 | 100 A,30KA,FPMCCB |
| 49 | DSR Item No. 1.15Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required. |
| 50 | Group C. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender