Public Administrative Department Local Bodies Closing in 13 days TDR #58605969

Tender For Leakage Repairing Of Different Size Acp/Pvc/Hpde/D.I./C.I. Pipeline At Alkapuri And Pashvnath Oht.

Issued by Local Bodies · Ujjain, Madhya Pradesh
Tender Value
6.46 Lakhs
Estimated cost
Bid Submission
09 Dec 2026
13 days left
EMD
12940
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ujjain → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Leakage Repairing Of Different Size Acp/Pvc/Hpde/D.I./C.I. Pipeline At Alkapuri And Pashvnath Oht.

BOQ

Name of Work:- Leakage Repairing of different size ACP/PVC/HPDE/D.I./C.I. Pipeline at Alkapuri and pashvnath OHT.
Sl. No. Item Description
1Dewatering arrangement including fixing of low head high discharge mud pump with suction of delivery pipe as required
2Manufacturing of special and pipes made out steel plate of HR coils 8MM to 10 MM thick plate in shape and size condition I/C cost of steel plate and other electricals and mechanical material i/c submerged are welding i/c cost of transportation, loading & unloading complete pipe and special barel piece, gap piece, spigot and socket end, plain & socket clamp etc.as per site condition
3Higher charges for diesel generator set / electric connection from electric pole for cutting, welding of MS pipe and dewatering work and lightening arrangement etc. complete
4Charges for lighteing, berickating and traffic diverting from leackage site with safety arrangement during leackage repairing work i/c fixing of bulli, wire rop, alojan lamp, cuation board, caution flag for the traffic diversion and removing all these material after completion of work from site i/c loading, unloading & 1 Days X12 Month
5Providing and fixing gland rope 6 mm dia as per IS 5414days 1995 make champion/turner/ equivalent
6Providing and fixing gland rope 10 mm dia as per IS 5414- 1995 make champion/turner/ equivalent
7Provision for making arrangement for electricity from MPEB to run welding transformer, de watering pump and grinding machine, lamp etc.complete at site.
8Manufacturing and supply of MS volve operating key and following size of sluice volve made out by single piece as per standard and site condition 150 mm dia
9Providing & fixing of neoprence rubber sheet 3 & 6 mm as per I.S.-638-1979Make TRPL/National/Equivalent
10Providsing & fixing of nut bolt, washer, size as per requirement aas per I.S. 1363-1992 &I.S.-4218 part - 5 -1967 make Tata/GKW/Standard/ Equivalent
11Fabrication & Providing of extra of Extra long 3 mtr MS key as per sample made MS rod 25 mm thick & MS cap molded on the sluice valve spindle &grouting 50x50x8 mm angle clamp in the chamber wall sluice vlave open & close work at Gambhri line section
12Providing & fixing Rubber ring
1380 MM dia
14100 MM dia
15150 MM dia
16200 MM dia
17Supply of wooden Handle hand made for spread & axxis
18Labour charges for shaftning of chisel, axxis & Digging rod
19Providing and fixing spun yarn Best quality
20Providing and fixing of lead wool containing 90 % lead as per IS-318-1981
21Providing & fixing pig lead 99% pure
22Providing & applying of M-seal compound make mahindra
23supply of SS 410 spendal rod without GM chek nut for following dia S/V
2480 MM dia
25100 MM dia
26150 MM dia
27200 MM dia
28Recxasting of following dia sluice vlave GM check nut i.c recasting, finishing, machining and threading as per sample and cost of extra material complete work.
2980 MM dia
30100 MM dia
31150 MM dia
32200 MM dia
33Repairing of folowing dia sluice valve i/c fixture check nut guid both side i/c welding, finishing, cutting clamping as per size of check nut
3480 MM dia
35100 MM dia
36150 MM dia
37200 MM dia
38300 MM dia
39400 MM dia
40Labour charges for opening and refitting of following dia sluice valve i/c cutting of old damged nut bolt, removal of damaged gland packing, rubber packing, providing, fixing of new by fabricated parts and greasing properly cost of nut bolt over-handling the valve, transportation of material T&P testing and making with risk cover as per requirement
4180 MM dia
42100 MM dia
43150 MM dia
44200 MM dia
45300 MM dia
46400 MM dia
47Dismantling of cement concrete pavement i/c breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead upto 1000 meter, stacking serviceable and unserviceable materials separately and as per relevant clauses of section-20018.12/229
48Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed.18.2.1 All kinds of ordinary soil Cum 151.0018.2/227
49Providing, Laying, Jointing & Testing of Asbestos cement pressure pipe ISI marked and conforming to IS-1592/03 tested to the required pressure including cost of pipes all complete.9.1/132
5080 mm Class 15
51100 mm Class 15
52150 mm Class 15
53Labour for cutting following Asbestos Cement Pressure Pipes of any type and class.19.2/239
5480 mm 6 Kg
55100 mm 6 Kg
56150 mm 6 Kg
57Providing & fixing detachable joints to asbestos cement pressure pipes and fittings including C.I. detachable joints confirming to IS/8794/1988 with bolts, nuts and rubber rings9.4/133
5880 mm
59100 mm
60150 mm
61200 mm
62Providing, laying, Jointing & field testing of High Density Polyethylene pipes, (HDPE) confirming to IS 4984/ 14151/ 12786/ 13488 with necessary jointing material like mechanical connector or jointing pipes by heating to the ends of pipes with the help of Teflon coated electric mirror/ heater to the required temperature and then pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with Jacks/Hydraulic Jacks/ But fusion machine. (50mm & above fusion jointed & below 50mm mechanical jointed)7.1/103
6390 mm
64110mm
65160 mm
66200 mm
67250 mm
68315 mm
69Providing butt fusion welded joint/jointing by heating to the ends with the help of Teflon coated electric mirror/heater ends together etc. by thermosetting process to HDPE Pipe and specials. (6kg, 8kg, 10kg) (50mm & above fusion jointed & below 50mm mechanical jointed)7.9/108
7090 mm
71110mm
72160 mm
73200 mm
74250 mm
75315 mm
76Providing, laying, jointing & testing of following P.V.C. pipes with solvent cement joint for 6, 8 and 10 kg/ sq. cm. pressures including testing of joints, cost of jointing materials etc. complete in all respect.5.1/81
7790 mm 6 Kg
78110 mm 6 Kg
79160 mm 6 Kg
80Providing and laying in position following PVC Tees, suitable for 6, 8 and 10 Kg/Sqcm. Pressure pipes.5.6/82
8190 mm 6 Kg
82110 mm 6 Kg
83160 mm 6 Kg
84200 mm 6 Kg
85Providing and laying in position following PVC end Cap (plugs) suitable for 6, 8 and 10 Kg/Sq cm. Pressure pipes.90 mm 6 Kg5.8.1/83
86Providing and laying in position PVC coupler suitable for 6, 8 and 10 Kg/Sq. cm. Pressure pipes.5.9/83
8790 mm 6 Kg
88110 mm 6 Kg
89160 mm 6 Kg
90Providing, laying, jointing, testing and commissioning of ISI marked PVC- O (Oriented Plasticized Polyvinyl Chloride) ring fit type pipe having orientation class 500 : C-1.4 with integral homogeneous spigot, elastomeric sealing ring made of EPDM rubber (one per pipe) including testing of joints, cost of jointing materials etc. Complete in all respect. Pressure Rating as per IS Code — IS:16647-2017 for following diameters.5.12/84
91110 mm
92160 mm
93200 mm
94250 mm
95315 mm
96Providing & laying Ductile iron Mechanical joint collar with follower glands conforming to IS-9523/2000 having dimension as per table 24 of IS-9523/2000 in the nominal diameter/sizes with external bitumen coating and internal cement mortar lining.4.11/61
97100 mm
98150 mm
99200 mm
100250 mm
101300 mm
102Labour for cutting following cast iron pipes of any type and class.19.1/239
103100 mm
104150 mm
105200 mm
106250 mm
107300 mm
108Filling by available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.18.2.8/228
109Providing and laying in position Plain cement concrete (PCC) of specified grade excluding the cost of centering and shuttering 18.14.5 Cement concrete grade M-10 (Nominal Mix) with 20 mm maximumsize of stone aggregate18.14.5/229
110Providing and laying in position Plain cement concrete (PCC) of specified grade excluding the cost of centering and shuttering 18.14.3 Cement concrete grade M-20 (Nominal Mix) with 20 mm maximumsize of stone aggregate18.14.3/229 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58605969
AUTHORITY Local Bodies
TENDER VALUE 6.46 Lakhs
LAST DATE 09-12-2026
Authority
Authority Name Municipal Corporation
Work Description Tender for Leakage Repairing Of Different Size Acp/Pvc/Hpde/D.I./C.I. Pipeline At Alkapuri And Pashvnath Oht.
Basic Detail
Tender No PHE/E-TENDER 233/2026
Bidding Type Tender
Location
City Ujjain
State Madhya Pradesh
Key Dates
Publish Date 19 Nov 2026
Submission Date 09 Dec 2026
Open Date 11 Dec 2026
Finance
Tender Value 6.46 Lakhs
Tender Fee 2000
EMD 12940
Exemption Not Available
Document List
667c4f34-532b-4249-861e-a24c8ca9fa1e.html
BOQ_662014.xls
condition.pdf
tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Dec 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

667c4f34-532b-4249-861e-a24c8ca9fa1e.html

xls

BOQ_662014.xls

pdf

condition.pdf

pdf

tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender