Tender For Construction Of Staff Quarters ( C & D Type) For Pipalapanka Irrigation Project At Sorada (Civil, Ph & Electrical).
Tender Value
1.52 Crore
Estimated cost
Bid Submission
03 Dec 2026
10 days left
EMD
1.52 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ganjam → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Staff Quarters ( C & D Type) For Pipalapanka Irrigation Project At Sorada (Civil, Ph & Electrical).
BOQ
| Sl. No. | Item Description |
| 1 | Earth work excavation in hard or gravelly soil within 50 m initial lead, 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm & laying in layer not exceeding 0.3m in depth and dewatering if necessary and trimming the slopes & bed to design section with all labour, T &P, hire & running charges of all other machineries required for the work etc. complete in all respect and as per the specification and as directed by the Engineer - in - charge. (For Ground Floor) |
| 2 | Supplying and laying sand of approved quality from approved quarry free from any deleterious materials on compacted surfaces of foundation plinth, inside of room and other places wherever required to proper thickness with surface dressing including all cost, conveyance, cess, and taxes of all materials to the site of work with all labour and T&P required etc. finished with all leads, lifts, delifts etc. complete as per the specification and direction of the Engineer-in-Charge. (Ground Floor) |
| 3 | Anti termite treatment to bottom surface (in case of masonry foundation and basements) and the sides (upto a height of 300 mm from bottom) of the excavation trenches with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 litres per sq. m area.(As per Quotation) (Ground Floor ) |
| 4 | Providing cement concrete M15 A40 using 40 mm and downgraded hard granite crusher broken metal from approved quarry of approved quality of uniform colour and texture and free from weathered skin and other deleterious materials and clean course sand free from all deleterious materials from approved quarry including loading & unloading at site and mixing the concrete by concrete mixer or by manually and placing the same in form work to all height as per the drawing and compacting with concrete by vibrator or by manually to required thickness and watering for curing with all leads lifts and delifts including cost, carriage, royalty, DMF,EMF & additional charge, cess, taxes of all materials, water etc. with all labour, T&P required with hire and running charges of concrete mixer and vibrator etc. complete & as per the specification and direction of the Engineer - in - Charge. (Ground Floor) |
| 5 | Providing R.C.C M-20 grade using 20 mm & downgraded size hard granite crusher broken chips of approved quality uniform colour and texture and free from weathered skin and other deleterious materials and clean course sand free from all deleterious materials from approved quarry including loading & unloading at site and mixing the concrete by concrete mixer and hoisting & laying the concrete in form work to all height as per the drawing and compacting with concrete by vibrator to required thickness and watering for curing with all leads lifts and delifts including cost, carriage, royalty,DMF,EMF & additional charge, cess, taxes of all materials, water etc. with all labour, T&P required with hire and running charges of concrete mixer and vibrator etc. complete & as per the specification and direction of the Engineer - in - Charge. (Ground Floor ) |
| 6 | Providing R.C.C M-20 grade using 20 mm & downgraded size hard granite crusher broken chips of approved quality uniform colour and texture and free from weathered skin and other deleterious materials and clean course sand free from all deleterious materials from approved quarry including loading & unloading at site and mixing the concrete by concrete mixer and hoisting & laying the concrete in form work to all height as per the drawing and compacting with concrete by vibrator to required thickness and watering for curing with all leads lifts and delifts including cost, carriage, royalty,DMF,EMF & additional charge, cess, taxes of all materials, water etc. with all labour, T&P required with hire and running charges of concrete mixer and vibrator etc. complete & as per the specification and direction of the Engineer - in - Charge. (First Floor ) |
| 7 | Supplying of uncoated HYSD steel reinforcement for RCC work of all diameters and sizes of approved quality as per design and tying the grills, welding and placing in position at all heights including cost of all lapping, approved quality of binding wire of 18 to 20 gauge including all cost, conveyance, cess and taxes of all materials to the site of work with all labour and T&P required etc. finished with all leads, lifts, delifts etc. complete as per the specification and direction of the Engineer-in-Charge.(Ground Floor ) |
| 8 | Supplying of uncoated HYSD steel reinforcement for RCC work of all diameters and sizes of approved quality as per design and tying the grills, welding and placing in position at all heights including cost of all lapping, approved quality of binding wire of 18 to 20 gauge including all cost, conveyance, cess and taxes of all materials to the site of work with all labour and T&P required etc. finished with all leads, lifts, delifts etc. complete as per the specification and direction of the Engineer-in-Charge.(First floor ) |
| 9 | Providing brick masonary work with Fly Ash bricks of (25x12x8)cm size in (1:4) having crushing strength not less than 75 Kg/cm2 with dimensional tolerance ±8 percent in cement mortar (1:6) with clean course sand free from all deleterious materials from approved quarry including cost, conveyance, royalty,DMF,EMF, additional charge, labour cess & taxes of all materials with all labour and T & P including finishing the outer surface smooth with all leads, lifts and delifts including sufficient curing the masonary to achive design strength etc. complete and as per the specification, design & drawing and as directed by the Engineer-in-charge.(Ground Floor ) |
| 10 | Providing brick masonary work with Fly Ash bricks of (25x12x8)cm size in (1:6) having crushing strength not less than 75 Kg/cm2 with dimensional tolerance ±8 percent in cement mortar (1:6) with clean course sand free from all deleterious materials from approved quarry including cost, conveyance, royalty,DMF,EMF, additional charge, labour cess & taxes of all materials with all labour and T & P including finishing the outer surface smooth with all leads, lifts and delifts including sufficient curing the masonary to achive design strength etc. complete and as per the specification, design & drawing and as directed by the Engineer-in-charge.(Ground Floor ) |
| 11 | Providing brick masonary work with Fly Ash bricks of (25x12x8)cm size in (1:6) having crushing strength not less than 75 Kg/cm2 with dimensional tolerance ±8 percent in cement mortar (1:6) with clean course sand free from all deleterious materials from approved quarry including cost, conveyance, labour cess & taxes of all materials with all labour and T & P including finishing the outer surface smooth with all leads, lifts and delifts including sufficient curing the masonary to achive design strength etc. complete and as per the specification, design & drawing and as directed by the Engineer-in-charge.(First floor) |
| 12 | Providing rigid & Smooth centering & shuttering for Rcc Foundation ,Plinth Band,footing bases of concrete,mass concrete including cost of all chrages etc all completeas per the specification, design & drawing and as directed by the Engineer-in-charge. (Ground Floor) |
| 13 | Rigid smooth centering & shuttering for R.C.C. works in Beam, Column,Girders & Bressmer etc including false works and dismentaling then after casting &as per the specification, design & drawing and as directed by the Engineer-in-charge. (Ground Floor ) |
| 14 | Rigid smooth centering & shuttering for R.C.C. works in Beam, Column,Girders & Bressmer etc including false works and dismentaling then after casting & as per the specification, design & drawing and as directed by the Engineer-in-charge.(First floor) |
| 15 | Rigid smooth centering & shuttering for R.C.C. works in Lintels etc including false works and dismentaling then after casting & as per the specification, design & drawing and as directed by the Engineer-in-charge.(Ground Floor) |
| 16 | Rigid smooth centering & shuttering for R.C.C. works in Lintels etc including false works and dismentaling then after casting & as per the specification, design & drawing and as directed by the Engineer-in-charge.(First Floor) |
| 17 | Rigid smooth centering & shuttering for R.C.C. works in floor and roof slabs Landings Balconies, projecting shun shades and chajja upto 4.30m height etc including false works and dismentaling then after casting & as per the specification, design & drawing and as directed by the Engineer-in-charge. (Ground Floor) |
| 18 | Rigid smooth centering & shuttering for R.C.C. works in floor and roof slabs Landings Balconies, projecting shun shades and chajja upto 4.30m height etc including false works and dismentaling then after casting & as per the specification, design & drawing and as directed by the Engineer-in-charge.(First Floor) |
| 19 | Rigid smooth centering & shuttering for R.C.C. works in stairs excluding landing but including railing etc including false works and dismentaling then after casting & as per the specification, design & drawing and as directed by the Engineer-in-charge. (Ground Floor) |
| 20 | Rigid smooth centering & shuttering for R.C.C. works in stairs excluding landing but including railing etc including false works and dismentaling then after casting& as per the specification, design & drawing and as directed by the Engineer-in-charge. (First Floor) |
| 21 | 20mm thick cement plaster with (1:4) for roof slab with all leads lifts and delifts including cost of carriage, royalty, DMF, EMF & additional charge, taxes of all materials, labour cess and T & P as per the specification, design & drawing and as directed by the Engineer-in-charge. ( Ground Floor ) |
| 22 | 20mm thick cement plaster with (1:4) for roof slab with all leads lifts and delifts including cost of carriage, royalty, DMF, EMF & additional charge, taxes of all materials, labour cess and T & P as per the specification, design & drawing and as directed by the Engineer-in-charge (First floor) |
| 23 | 12 mm thick cement plaster (1:4) for brick including cement punning over top of wall with include cost of carriage,royalty, DMF, EMF & additional charge, taxes of all materials, labour cess and T & P as per the specification, design & drawing and as directed by the Engineer-in-charge. (Ground Floor) |
| 24 | Providing 12mm thick cement plaster (1:6) for out side surface of brick masonary with clean fine sand free from all deleterious materials from approved quarry including loading & unloading at site and mixing by mixer or by manually and plaster the same in all height as per the drawing and required thickness and watering for curing with all leads lifts and delifts including cost, carriage, royalty, cess, taxes of all materials, water etc. with all labour, T&P required with hire and running charges of all machinaries etc. complete & as per the specification and direction of the Engineer - in - Charge. (Ground Floor) |
| 25 | Providing 12mm thick cement plaster (1:6) for out side surface of brick masonary with clean fine sand free from all deleterious materials from approved quarry including loading & unloading at site and mixing by mixer or by manually and plaster the same in all height as per the drawing and required thickness and watering for curing with all leads lifts and delifts including cost, carriage, royalty, cess, taxes of all materials, water etc. with all labour, T&P required with hire and running charges of all machinaries etc. complete & as per the specification and direction of the Engineer - in - Charge.(First Floor) |
| 26 | Providing 16mm thick cement plaster (1:6) for inside surface of brick masonary with clean fine sand free from all deleterious materials from approved quarry including loading & unloading at site and mixing by mixer or by manually and plaster the same in all height as per the drawing and required thickness and watering for curing with all leads lifts and delifts including cost, carriage, royalty, cess, taxes of all materials, water etc. with all labour, T&P required with hire and running charges of all machinaries etc. complete & as per the specification and direction of the Engineer - in - Charge. (Ground Floor) |
| 27 | Providing 16mm thick cement plaster (1:6) for inside surface of brick masonary with clean fine sand free from all deleterious materials from approved quarry including loading & unloading at site and mixing by mixer or by manually and plaster the same in all height as per the drawing and required thickness and watering for curing with all leads lifts and delifts including cost, carriage, royalty, cess, taxes of all materials, water etc. with all labour, T&P required with hire and running charges of all machinaries etc. complete & as per the specification and direction of the Engineer - in - Charge.(First Floor) |
| 28 | Suppling, fitting & Fixing vertified tiles in floor of size 600mm X 600mm of approved making conforming to I.S : 13755 laid on 20mm thick cement mortar (1:4) & filling joints with white cement of approved quality including rubbing and polishing complete with all leads lifts and delifts including cost, carriage, royalty, cess, taxes of all materials, etc. with all labour, T&P required with hire and running charges of all machinaries etc. complete & as per the specification and direction of the Engineer - in - Charge. (Ground Floor) |
| 29 | Suppling, fitting & fixing vertified tiles in floor of size 600mm X 600mm of approved making conforming to I.S : 13755 laid on 20mm thick cement mortar (1:4) & filling joints with white cement of approved quality including rubbing and polishing complete with all leads lifts and delifts including cost, carriage, royalty, cess, taxes of all materials, etc. with all labour, T&P required with hire and running charges of all machinaries etc. complete & as per the specification and direction of the Engineer - in - Charge. (First floor) |
| 30 | Fixing vertified tiles in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing with all leads lifts and delifts including cost, carriage, royalty, cess, taxes of all materials, etc. with all labour, T&P required with hire and running charges of all machinaries etc. complete including cost of precast tiles. as per the specification and direction of Engineer-in-charge.s. (Ground Floor ) |
| 31 | Fixing vertified tiles in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing with all leads lifts and delifts including cost, carriage, royalty, cess, taxes of all materials, etc. with all labour, T&P required with hire and running charges of all machinaries etc. complete including cost of precast tiles. as per the specification and direction of Engineer-in-charge. (First floor) |
| 32 | Fixing ceramic tiles in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing with all leads lifts and delifts including cost, carriage, royalty, cess, taxes of all materials, etc. with all labour, T&P required with hire and running charges of all machinaries etc.complete including cost of precast tiles as per the specification and direction of Engineer-in-charge. (Ground Floor) |
| 33 | Fixing ceramic tiles in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing with all leads lifts and delifts including cost, carriage, royalty, cess, taxes of all materials, etc. with all labour, T&P required with hire and running charges of all machinaries etc.complete including cost of precast tiles as per the specification and direction of Engineer-in-charge. (First Floor) |
| 34 | Fixing ceramic wall tiles in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing with all leads lifts and delifts including cost, carriage, royalty, cess, taxes of all materials, etc. with all labour, T&P required with hire and running charges of all machinaries etc. complete including cost of precast tiles as per the specification and direction of Engineer-in-charge. (Ground Floor) |
| 35 | Fixing ceramic wall tiles in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing with all leads lifts and delifts including cost, carriage, royalty, cess, taxes of all materials, etc. with all labour, T&P required with hire and running charges of all machinaries etc. complete including cost of precast tiles as per the specification and direction of Engineer-in-charge. (First Floor) |
| 36 | Supplying, Fixing granite tiles in risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete with all leads lifts and delifts including cost, carriage, royalty, cess, taxes of all materials, etc. with all labour, T&P required with hire and running charges of all machinaries etc. complete & as per the specification and direction of the Engineer - in - Charge. (Ground Floor) |
| 37 | Supplying, Fixing granite tiles in risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete with all leads lifts and delifts including cost, carriage, royalty, cess, taxes of all materials, etc. with all labour, T&P required with hire and running charges of all machinaries etc. complete & as per the specification and direction of the Engineer - in - Charge. (First Floor) |
| 38 | Finishing wall surface of walls with acrylic wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials, all taxes, labour, Cess and T&P etc complete as per direction of Engineer-in-Charge. (Ground Floor) |
| 39 | Finishing wall surface of walls with acrylic wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials, all taxes, labour, Cess and T&P etc complete as per direction of Engineer-in-charge. (First Floor) |
| 40 | Finishing walls with Primer of approved shade on new work two coat to give an even shade including cost of paint, including cost of Scaffolding staging charges with cost of all materials, all taxes, Labour, Cess and T&P as per the specification and direction of the Engineer - in - Charge. (Ground Floor) |
| 41 | Finishing walls with Primer of approved shade on new work two coat to give an even shade including cost of paint, including cost of Scaffolding staging charges with cost of all materials, all taxes, Labour, Cess and T&P as per the specification and direction of the Engineer - in - Charge. (First floor) |
| 42 | Finishing walls with weather coat of approved shade on new work two coat to give an even shade including cost of paint with cost of all materials, all taxes, Labour, Cess and T&P as per the specification and direction of the Engineer - in - Charge. (Ground Floor) |
| 43 | Finishing walls with weather coat of approved shade on new work two coat to give an even shade including cost of paint with cost of all materials, all taxes, Labour, Cess and T&P as per the specification and direction of the Engineer - in - Charge. (First floor) |
| 44 | Wall painting two coats to walls with Plastic Emulsion paint of approved shade on new work to give an even shade including cost of Paint, all taxes,labour, Cess and T&P etc complete as per direction of the Engineer-in-charge. (Ground Floor) |
| 45 | Wall painting two coats to walls with Plastic Emulsion paint of approved shade on new work to give an even shade including cost of Paint, all taxes,labour, Cess and T&P etc complete as per direction of the Engineer-in-charge.( First floor) |
| 46 | Supplying, fitting and fixing of M.S panelled Door on wall in position with C.C. (1:3:6) of double leaved shutter with M.S. frame & grill overall size including frame 1800mm Height x 750mm Width made out of the following materials conforming to relevant ISS Frame 35x35x6mm M.S.Angle shutter style top & bottom rail 25x25x3mm M.S.Angle Door pannel1.0mm C.R.sheet, pannel stiffener covering width of each leaf 19x5mm M.S. Flat 3 nos on each leaf. Hinges size 100mm 6 nos (3 nos on each side) bought out as per ISS. Hold last 35x35x6mm M.S. Angle 175mm length bifurcated tip 3 nos. one each side. Handle- 19x5mm M.S.Flat 4 nos fabricated . Aldropt:- 2nos bought out as per ISS, . Handle 19x5mm M.S.Flat 2 nos fabricated (inside). Tower bolt 2 nos bought out as per ISS including all cost. conveyance, labour charges all taxes, T&P, cess etc. complete as per direction of the Engineer-in-charge. (Ground Floor and first floor) |
| 47 | Supplying, fitting and fixing of M.S panelled window double leaved shutter with M.S. frame & grill overall size including frame 1200mm Height x 900mm Width made out of the following materials conforming to relevant ISS Frame 35x35x6mm M.S.Angle shutter style top & bottom rail 25x25x3mm M.S.AngleWindow pannel1.0mm C.R.sheet, pannel stiffener covering width of each leaf 19x5mm M.S. Flat 2 nos on each leaf. Hinges size 100mm 4 nos (2 nos on each side) bought out as per ISS. Hold last 35x35x6mm M.S. Angle 100mm length bifurcated tip 2 nos. one each side. Handle- 19x5mm M.S.Flat 2 nos fabricated (inside). Towerbolt:- 4nos bought out as per ISS Hold fast 35x35x6mm M.S.Angle 100mm length bifurcated tip 2 nos one each side. Handle 19x5mm M.S.Flat 2 nos fabricated (inside). Tower bolt 4 nos bought out as per ISS Horizontal Grill 12mm M.S.Round at 100mm spacing including all cost. conveyance, labour charges all taxes, T&P, cess etc. complete as per direction of the Engineer-in-charge.(Ground Floor and first floor) |
| 48 | M.S.Varandah Grill made out of M.S.Angle at the periphery and M.S.Flat in the inner Design, conforming to IS:2062/2006 with hold fast made out of M.S.Angle as used in periphery, painted with Red oxide primer as per the design approved including all cost, conveyance labour charges all taxes, T&P, Cess etc complete as per direction of the Engineer-in-charge. (Ground Floor and first floor) |
| 49 | Painting one coat with any approved primer as per the design approved including all cost, conveyance, labour charges all taxes, T&P, Cess etc complete as per direction of the Engineer-in-charge. (Ground Floor) |
| 50 | Painting one coat with any approved primer as per the design approved including all cost, conveyance, labour charges all taxes, T&P etc complete as per direction of the Engineer-in-charge. (First floor) |
| 51 | Painting two coats with approved paint on new wood work as per the design approved including all cost, conveyance, labour charges all taxes, T&P etc complete as per direction of the Engineer-in-charge. (Ground Floor ) |
| 52 | Painting two coats with approved paint on new wood work as per the design approved including all cost, conveyance, labour charges all taxes, T&P etc complete as per direction of the Engineer-in-charge. (First floor) |
| 53 | Supplying, fitting,fixing up window ( sliding type) made up aluminium section 151-154,151-155, as windows frame section No 151-155,4151-153,151-167 as shutter frame with 5mm thick black glass as panel fitted with rubber beading including cost of materials all taxes labour T&P, Cess etc. complete as per direction of engineer in charge. (Ground Floor and first Floor) |
| 54 | Supplying ,fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mmx32mmx2mm @0.90mtr. C/C and stainless square pipe bracing of size 32mmx32mmx2mm in 3 rows in stair case as per approved design and specification ,buffing polishing etc.with cost,conveyance,taxes of ll materials,labour,T&P , Cess etc.required for the complete in all respect. (Ground Floor and first Floor) |
| 55 | Supplying and filling with brick khoa 40mm size as per the design approved including all cost, conveyance, labour charges all taxes, T&P, Cess etc complete as per direction of the Engineer-in-charge. (Ground Floor and first Floor) |
| 56 | Filling in foundation and plinth with excavated materials including watering and ramming including Cost of labour charges all taxes, T&P, Cess etc complete as directed by the Engineer in-charge . |
| 57 | PH fittingProviding and fixing 20 mm dia CPVC Pipes as per IS 15778:2007 SDR 11, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete all cost labour charges all taxes, Cess and T&P etc. as per direction of Engineer-in-Charge. |
| 58 | Providing and fixing 25 mm dia CPVC Pipes as per IS 15778:2007 SDR 11, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete all cost labour charges all taxes, Cess and T&P etc.as per direction of Engineer-in-Charge. |
| 59 | Providing and fixing on wall face 110mm OD PVC SWR S/S Pipe (ISI type-A), including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 60 | Providing and fixing on wall face 110 x 110 x 110 mm dia PVC SWR Tee, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 61 | Providing and fixing on wall face 110mm dia PVC SWR plain bend 87.5°, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 62 | Providing and fixing on wall face 110mm dia PVC SWR HR bend 45°, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 63 | Providing and fixing on wall face 75mm OD PVC SWR S/S Pipe (ISI type-A), including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 64 | Providing and fixing on wall face 75X75X75 mm dia PVC SWR Tee, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 65 | Providing and fixing on wall face 75 mm dia PVC SWR plain bend 87.5°, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 66 | Providing and fixing on wall face 75 mm dia PVC SWR HR bend 45°, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 67 | Providing and fixing on wall face 75 mm dia P.V.C. SWR Vent Cowl, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 68 | Providing and fixing on wall face 110 mm dia P.V.C. SWR Vent Cowl, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 69 | 90mm dia P.V.C. Nahani Trap as per specification and direction of the Engineer-in-charge. |
| 70 | 110mm dia P.V.C. Nahani Trap with out Jallyas per specification and direction of the Engineer-in-charge. |
| 71 | 110mm dia P.V.C. SWR Gully trap as per specification and direction of the Engineer-in-charge. |
| 72 | 75mm dia PVC SWR Door cap as per specification and direction of the Engineer-in-charge. |
| 73 | 110 mm dia PVC SWR Door cap as per specification and direction of the Engineer-in-charge. |
| 74 | Cutting holes through the brick or laterite masonry wall for taking Sand Cast Iron (SCI) /centrifugally cast (spun) iron pipes and mending good the damages included cost of material, cost labour charges all taxes, Cess and T&P etc. complete as per direction of Engineer- in-Charge. |
| 75 | Cutting by chiselling in brick masonry wall for fixing sand cast iron pipes of following nominal size and fittings including making good the same with brick work in cement mortar (1:3) including plastering all cost labour charges all taxes, Cess and T&P etc. complete as per specification and direction of Engineer-in-charge. |
| 76 | Providing, fitting & fixing Porcelain 23\\" I.W.C. (Orissa Pan) conforming to IS 2556 : Part 3-2004 duly embedded in cement concrete (1:4:8) using hard granite metal 4cm nominal size all complete as per specification including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 77 | Providing, fitting & fixing Porcelain EWC with P-trap conforming to IS 2556 : Part 8-2004, to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification. (Seat and cover to be measured and paid for separately) including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 78 | Providing, fitting & fixing EWC PVC standard Seat Cover for wash down water closet with chromium plated brass hinges and rubber buffers all complete as per specification including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 79 | Providing, fitting & fixing 10 liter P.V.C. low level Cistern with fittings manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 80 | Providing, fitting & fixing Porcelain 22\\"x 16\\"(550x400) W.H.B with hole for pillar taps conforming to IS 2556 : Part 4-2004 with Cast Iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 81 | Providing, fitting & fixing Porcelain Standard Pedestal for W.H.B complete recessed at the back for the reception of pipes and fittings including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 82 | Providing, fitting & fixing 24\\"x 18\\"x 10\\" STEEL sink single bowl (Ordinary ) as per IS 13983 with C.I brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 83 | Providing, fitting & fixing 100mm dia S.C.I. P Trap of outlet of self cleaning design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors all complete as per specification including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 84 | Providing, fitting & fixing standard C.P. Towel Rail (600x20mm) complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws, complete as per specification including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 85 | Providing, fitting & fixing standard C.P. Towel Ring fixed to wooden plugs with Chromium Plated brass screws, complete as per specification including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 86 | Providing, fitting & fixing of C.P. soap holder/disc fixed to wooden plugs with Chromium Plated brass screws or (b) Chromium Plated brass soap dish complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws or (c) White glazed tooth brush holder fixed to wooden plugs with Chromium Plated brass screws as per specification including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 87 | Providing, fitting & fixing of C.P. revolving shower with arm (overhead) including polishing all complete as per specification including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 88 | Providing, fitting & fixing of C.P. Telephonic shower with CP/PVC flexible tube with hook including polishing all complete as per specification including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 89 | Providing, fitting & fixing of C.P. Health Faucet with 1.01m PVC Tube including polishing all complete as per specification including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 90 | Providing & Fixing Bath Room Mirror (600mm x 600mm) bevelled edge mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with chromium plated brass screws and washers complete as per specification complete including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 91 | Providing, fitting & fixing of 15mm dia C.P. Short body bib cock polished bright conforming to IS:781-1995 of the following nominal sizes as per specification complete including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 92 | Providing, fitting & fixing of 15mm dia C.P. Long body bib cock polished bright conforming to IS:781-1995 of the following nominal sizes as per specification complete including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 93 | Providing, fitting & fixing of 15mm dia C.P. Swan neck pillar cock with spout polished bright conforming to IS:781-1995 of the following nominal sizes as per specification complete including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 94 | Providing, fitting & fixing of 15mm dia C.P. Angular stop cock polished bright conforming to IS:781-1995 of the following nominal sizes as per specification complete including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 95 | Providing, fitting & fixing of 15mm dia C.P. Pillar cock polished bright conforming to IS:781-1995 of the following nominal sizes as per specification complete including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 96 | Providing, fitting & fixing of UPVC Ball Valve Sch80 (Plastic Ball) 25mm dia. as per specification complete including all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 97 | Providing, fitting & fixing of 2000 Ltr capacity 3-Layer White Rotational Moulded Cylindrical Vertical water storage tanks (ISI marked) conforming to IS:12701-1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position etc all complete as per specification and direction of the Engineer in charge. |
| 98 | Laying in OD PVC SWR S/S Pipe (ISI type-A) of the following nominal diameter for all classes including jointing with supply of approved solvent cement by non-hit application method in cluding testing as per specification complete. (Earthwork in trenches, jointing of pipes, specials and fittings to be measured and paid for separately) |
| 99 | Electrical fittingsRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. GROUP-A |
| 100 | Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.GROUP-B |
| 101 | Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. GROUP-C |
| 102 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 103 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((flame retradant type)) with suitable size modular box & cover(flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 104 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 105 | Supplying,fixing of 1x6A+1X16A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( (flame retradant type) with suitable size modular box & metallic cover plate (both side)( falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 106 | Supplying,fixing of 3x6A+1X16A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( (flame retradant type) with suitable size modular box & metallic cover plate (both side)( falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 107 | Supplying,fixing of 1x16A+1X16A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( (flame retradant type) with suitable size modular box & metallic cover plate (both side)( falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 108 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 109 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 110 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 111 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (4X10+2X4) |
| 112 | Supplying and fixing of following sizes of HMS PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/BEC/Precision/Norpak/Kinjal.(Only for data, telephone, CCTV)20 MM. |
| 113 | Supplying and fixing of following sizes of HMS PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/BEC/Precision/Norpak/Kinjal.(Only for data, telephone, CCTV)25 MM. |
| 114 | Supplying and installation of 25A AC starter Modular type, Schneider/Siemens/Legrand coil voltage-230 Volt A.C. on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 115 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make-Schneider (Zencelo)/ legrand( ( Myrius)) /Panasonic (vision)as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 116 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 117 | Light fitting Fixture & FanSupplying, Erection, Fixing, connection & testing of Panasonic 40 LED GATE Light of (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) maintenance free having 2 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. Warrantied for a period of 5 years |
| 118 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge (Make: legrand Myrius / Schneider(Zencelo)/Panasonic(Vision)) |
| 119 | S/F of Street light- 90W,120 lm/w efficacy ,IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic coverPanasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj (5Years Warranty) |
| 120 | S/F of G.I. Street light Bracket with M.S. Clamp |
| 121 | BDBS,DB,MCBSSupply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years |
| 122 | 2+4 way MCB Enclosure DB (GLAZED door)Warranty on DB is 1 years |
| 123 | Supplying and fixing 25 Amps rating,C series,10KA breaking capacity, 2P 230 volts MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCB should be Replacement Warranty will be 1 years. |
| 124 | Supplying and fixing 40Amps 4P 415 volts, MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 3 years |
| 125 | Supplying and fixing 63Amps rating,C series,10KA breaking capacity, 4P 415 volts MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCB should be Replacement Warranty will be 1 years. |
| 126 | Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 230 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 year. |
| 127 | (Earthing) INSTALLATIONS/IT/C of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 128 | Providing and fixing 6 SWG G.I wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge. |
| 129 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 130 | PanelS/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for LIGHT panel) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 1 nos of 3P+N Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed. Mandatory provsion of cable alley is to be given. All the feeders shall have ON/OFF/TRIP indication. Make of SPD-OBO/DEHN/ABB, Make of MCB- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200In commer-1-01 numbers of 63 4P MCCB with ROM 16kA with adjustable Thermal magnetic Release with Ics=100% Icu. ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula)Busbar-1 04 numbers of 100Amps Aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing). Out going- 5 numbers of 40A 4P MCB 10kA,C series. ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200)Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 1 no. Digital Meter Displays Current, line to neutral & line to line Voltages, frequency & Power Factor. (VA & PF - Phase Wise & Average) for the incomer. (Make-Legrand/ABB/Schneider/Siemens ) |
| 131 | CABLINGSupplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. (3.5core x 25 sq mm) |
| 132 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 133 | Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. (3.5core x 25 sq mm) |
| 134 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (50mm) |
| 135 | Wiring for point/circuit wiring along with earth wire of following size of PVC insulated PVC sheathed FRLS multicore flexible copper cable laid on existing cable tray/through conduit as required. (Make:-Polycab/Finolex/KEI/Anchor/RR kable) (3Cx2.5sqmm) as per direction of Engineer-in-charge. |
| 136 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5) |
| 137 | Supply ,installation, testing and commissioning of main switches (IS 13940 part-3/1993 ) of following capacity on existing surface/wall mounting and completer with HRC fuse links, interconnections, earthing etc. as required (Make-Seimens/ HPL/ Anchor/ L&T/Havells/C&S/RK) 63Amp ICDP main switches with MS board. |
| 138 | Supplying and fixing 63Amps rating,C series,10KA breaking capacity, 2P 230 volts MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCB should be Replacement Warranty will be 1 years. |
| 139 | S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for POWER panel) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 1 nos of 3P+N Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed. Mandatory provsion of cable alley is to be given. All the feeders shall have ON/OFF/TRIP indication. Make of SPD-OBO/DEHN/ABB, Make of MCB- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200In commer-1-01 numbers of 125 4P MCCB with ROM 25kA with adjustable Thermal magnetic Release with Ics=100% Icu. ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula)Busbar-1 04 numbers of 200Amps Aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing). Out going- 5 numbers of 63A 4P MCB 10kA,C series. ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200)Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 1 no. Digital Meter Displays Current, line to neutral & line to line Voltages, frequency & Power Factor. (VA & PF - Phase Wise & Average) for the incomer. (Make-Legrand/ABB/Schneider/Siemens ) |
| 140 | CABLINGSupplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. (3.5core x 35 sq mm) |
| 141 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but less than 120 sq mm direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 142 | Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. (3.5core x 35 sq mm) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysDec 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer