Tender For Beautification Work At The Katarmal Devta Temple, Located In Udham Singh Nagar Within The Jaspur Assembly Constituency.
Tender Value
74.44 Lakhs
Estimated cost
Bid Submission
04 Dec 2026
6 days left
EMD
1.48 Lakhs
Bank guarantee accepted
Document Fee
4720
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Udam Singh Nagar → Uttarakhand
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Beautification Work At The Katarmal Devta Temple, Located In Udham Singh Nagar Within The Jaspur Assembly Constituency.
BOQ
| Sl. No. | Item Description |
| 1 | Excavation by mechanical means/ manual means in foundation trench or drain (not Exceeding 1.50 m in width or 10 Sqm on plan) including dressing of sides and ramming of bottoms lift up to 1.5 m including getting out the excavated soil and disposal of surplus excvated soil as directed with in lead of 50 m. in all kind of soil. |
| 2 | Providing and laying in position cement concrete of specified grade excluding cost of centering and shuttering of 1:4:8 with cement coarse sand and 40 mm graded stone in foundation. |
| 3 | B/Work F.P.S. brick of class designation 75 in foundation and plinth with 1:6 cement and sand mortar including all cost of material labour T&P etc for proper complition of work. |
| 4 | B/Work F.P.S. brick of class designation 75 in foundation and plinth with 1:4 cement and sand mortar including all cost of material labour T&P etc for proper complition of work. |
| 5 | B/Work F.P.S. brick of class designation 75 in super structure with 1:6 cement and sand mortar including all cost of material labour T&P etc for proper complition of work. |
| 6 | Providing and laying in position specified grade of reinforcement cement concrete excluding the cost of centering , shuttering finishing and reiforcement all work upto plinth with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)for Columns footing . |
| 7 | Reinforcement cement concrete work in wall ( Any Thickness) including attached Pilasters, butteresses, plinth, and string course fillet columns, posts, and struts etc, upto floor five level excluding cost of shuttering, centring, finishing and reinforcement1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)for Columns |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 9 | Centring and shuttering including shutterings , ropng , etc and removel from foundation footing bases of columns. |
| 10 | Centering and shuttering including shuttering ropping etc. and removel from columns piller piers abutments, post and struts. |
| 11 | Suspended floors, roofs, landings, balconies and access platform. |
| 12 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 13 | Reinforcement for R.C.C. work including straightening, cutting , bending, placing, in postion and binding all comlete for Thermo Mechanically treated bars. |
| 14 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: |
| 15 | Steel work welded in built up Section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc.as required in gratings, framed, guard bar, ladder, relling and gate. |
| 16 | Providing and fixing of ISI marked 35 mm thick flush door shutter Confirming to IS:2202 (Part-1) decorative bord construction with frame of Ist class hard wood and well matched commercial 3 ply venering with vertical grain or cross band face veneers on both face of shutter. |
| 17 | Providing and fixing aluminium sliding door bolts ISI marked anodi coating not less than grade AC 10 as per IS : 1868) transparent or colour or shade with nuts and screws etc. complete |
| 18 | Providing and fixing aluminium handles ISI marked anodised (anod less than grade AC 10 as per IS : 1868) transparent or dyed to req shade with necessary screws etc. complete : |
| 19 | Providing and fixing aluminium tower bolts ISI marked anodised (a not less than grade AC 10 as per IS : 1868 ) transparent or dyed t or shade with necessary screws etc. complete 150 mm long |
| 20 | Providing and fixing aluminium tower bolts ISI marked anodised (a not less than grade AC 10 as per IS : 1868 ) transparent or dyed t or shade with necessary screws etc. complete 100 mm long |
| 21 | 20 mm cement plaster 1:3 finished with a floating coat of neat cement in Dado including all cost of labour material T&P etc for proper complition of work. |
| 22 | 12 mm thick cement plaster 1:6 cement & sand mortar including supply of all labour material andT&P etc required for proper complition of work. |
| 23 | 15 mm thick cement plaster 1:6 cement & sand mortar on rough side including supply of all labour material andT&P etc required for proper complition of work. |
| 24 | 4.0 cm thick cement conrete flooring 1:2:4 cement coarse sand and 20 mm aggregate finished with a floting coat of neat cement including cement sullary but excluding the cost of nosing of teps etc. |
| 25 | Providing and fixing of glaass strips in joints of terrazo/cement conrete floor 40 mm wide and 40 mm thick. |
| 26 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4mm in both directions with wire of dia 0.63 mm all complete. |
| 27 | Providing and fixing 4.0 mm thick glazing in window, ventilator, shutter and partition etc. with putty as per direction of Engineer in Charge. |
| 28 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. |
| 29 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 30 | Finishing wall with textured exterior paint of required shade with two and more coat applied @3.28ltr/10 Sqm over and including base coat of water proofing cement paint applied 2.20 Kg/10Sqm. |
| 31 | Providing and applying plaster of peris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 32 | Distemring with Ist Qualiti Oil Bond washable distemper of approved brand and manufactur to give an even shade. |
| 33 | Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) :Light shade pigment using white cement |
| 34 | High Mast Light 2 Nos. |
| 35 | Wiring for light point/ fan point/ exhaust fan point/ call bel point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B |
| 36 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.WGSTLSB Circuit/ submain wiring in pvc conduit: |
| 37 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. |
| 38 | Supplying and fixing following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Modules (75 mm X 75 mm) |
| 39 | 5/6 A switch |
| 40 | 3 pin 5/6 A socket outle |
| 41 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 42 | Supplying and fixing suitable size GI box with modular plate and cover in front on surfaceor on recss, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 43 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 44 | Installation, testing and commissioning of pre wired, fluorescent fitting / compact fluorescent fitting of all types,complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 45 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 46 | Supplying and fixing following way,single pole and neautral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 Way, Double Door |
| 47 | Supplying and fixing following rating, Double pole, 240 V, isolator in the existing MCB DB complete with connections , testing and commissioning etc. as required.40 Amps |
| 48 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 49 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required EARG125X6 S/L 25 MM X 5 MM G.I. earth strip in ground : |
| 50 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required(Jointing shall be done by overlapping and with 2. sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 51 | Supplying And Making end Terminal with brass comprasion gland and aluminium lugs for following size of PVC Insulated and PVC Sheeted/XLPE aluminium conductor Cable of 1.1KV grade as required. 2 x 6 sq. mm (19 mm) |
| 52 | Supply of AC 230/250 Volts, 50 Hz energy efficient ceiling fan with Standard down rod, blades,3 nos.caps Model- ES 50 (1200 MM Sweep) etc. complete, in all aspects as per direction of Engineer in charge.1200 mm Sweep |
| 53 | Supply and fixing on LED Tube light 1200 mm 20 W 865 T8 IP20, Lumen Output-1600, 3000,4000, 6500K ceiling mounted LED batten (E-Lite LED TRIYACA) extruded aluminium heat sink provided for efficient heat deissipation 7 & integrated electronic driver ( 1x20 W LED Double 6500K) complete in all aspects as per direction of Engineer in charge. |
| 54 | SUPPLY OF LED Glass Bulb B22, 15 W, 600K / 4000K/3000K, 230/250 volt, 50 HZ etc. complete in all aspects as per direction of Engineer in charge. |
| 55 | SUPPLY OF LED Ceilling Light B22, 15 W, 600K / 4000K/3000K, 230/250 volt, 50 HZ etc. complete in all aspects as per direction of Engineer in charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysDec 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender