Water Resources and Irrigation Government Departments Closing in 6 days TDR #58604245

Tender For Strengthening Work Of The Ancient Temple Located In The Dam Area Under The Legislative Assembly Of Jaspur.

Issued by Government Departments · Udam Singh Nagar, Uttarakhand
Tender Value
80.81 Lakhs
Estimated cost
Bid Submission
04 Dec 2026
6 days left
EMD
1.61 Lakhs
Bank guarantee accepted
Document Fee
4720
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Udam Singh Nagar → Uttarakhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Strengthening Work Of The Ancient Temple Located In The Dam Area Under The Legislative Assembly Of Jaspur.

BOQ

Name of Work:-
Sl. No. Item Description
1Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal ofstumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
2Concrete with cement, coarse sand and 40 mm gauge stone ballast in proportion 1:4:8 in foundations and floors including supply of all material, labour and T&P etc. required for proper completion of the work. as per drawings and technical specifications Clause 802, 803, 1202 & 1203
3Brick masonry work in cement mortar in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 600, 1202 & 1203 Brick masonry in 1:4 cement mortar
4Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5
5Granular sub-base/base/surface course with local materials (Table 400.13) by mix in place method normal Construction of granular sub-base by providing local material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at once and compacting with smooth wheel roller to achieve the desired density complete as per Clause 401.4 as per Technical Specification Clause 408.Using Gravel mix soil
6Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.WBM grade -3
7Construction of un-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 Cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days, using curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501
8Excavation by mechanical means/ manual means in foundation trench or drain (not Exceeding 1.50 m in width or 10 Sqm on plan) including dressing of sides and ramming of bottoms lift up to 1.5 m including getting out the excavated soil and disposal of surplus excvated soil as directed with in lead of 50 m. in all kind of soil.
9Providing and laying in position cement concrete of specified grade excluding cost of centering and shuttering of 1:4:8 with cement coarse sand and 40 mm graded stone in foundation.
10Providing and laying in position specified grade of reinforcement cement concrete excluding the cost of centering , shuttering finishing and reiforcement all work upto plinth with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)for Columns footing .
11Reinforcement cement concrete work in wall ( Any Thickness) including attached Pilasters, butteresses, plinth, and string course fillet columns, posts, and struts etc, upto floor five level excluding cost of shuttering, centring, finishing and reinforcement1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)for Columns
12Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
13B/Work F.P.S. brick of class designation 75 in super structure with 1:6 cement and sand mortar including all cost of material labour T&P etc for proper complition of work.
1412 mm thick cement plaster 1:4 cement & sand mortar including supply of all labour material andT&P etc required for proper complition of work.
15Centring and shuttering including shutterings , ropng , etc and removel from foundation footing bases of columns.
16Lintels, beams, plinth beams, girders, bressumers and cantilevers.
17Suspended floors, roofs, landings, balconies and access platform.
18Reinforcement for R.C.C. work including straightening, cutting , bending, placing, in postion and binding all comlete for Thermo Mechanically treated bars.
19Stone tile work for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade.Granite stone of any colour and shade
20Excavation by mechanical means/ manual means in foundation trench or drain (not Exceeding 1.50 m in width or 10 Sqm on plan) including dressing of sides and ramming of bottoms lift up to 1.5 m including getting out the excavated soil and disposal of surplus excvated soil as directed with in lead of 50 m. in all kind of soil.
21Providing and laying in position cement concrete of specified grade excluding cost of centering and shuttering of 1:4:8 with cement coarse sand and 40 mm graded stone in foundation.
22B/Work F.P.S. brick of class designation 75 in foundation and plinth with 1:6 cement and sand mortar including all cost of material labour T&P etc for proper complition of work.
23B/Work F.P.S. brick of class designation 75 in foundation and plinth with 1:4 cement and sand mortar including all cost of material labour T&P etc for proper complition of work.
24B/Work F.P.S. brick of class designation 75 in super structure with 1:6 cement and sand mortar including all cost of material labour T&P etc for proper complition of work.
25Half brick masonry with F.P.S. bricks of class designation 75 in superstructure abov plinth level upto floor V level in 1:4
26Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry (with F.P.S. bricks).
27Providing and laying in position specified grade of reinforcement cement concrete excluding the cost of centering , shuttering finishing and reiforcement all work upto plinth with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)for Columns footing .
28Reinforcement cement concrete work in wall ( Any Thickness) including attached Pilasters, butteresses, plinth, and string course fillet columns, posts, and struts etc, upto floor five level excluding cost of shuttering, centring, finishing and reinforcement1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)for Columns
29Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
30Centring and shuttering including shutterings , ropng , etc and removel from foundation footing bases of columns.
31Centering and shuttering including shuttering ropping etc. and removel from columns piller piers abutments, post and struts.
32Suspended floors, roofs, landings, balconies and access platform.
33Lintels, beams, plinth beams, girders, bressumers and cantilevers.
34Reinforcement for R.C.C. work including straightening, cutting , bending, placing, in postion and binding all comlete for Thermo Mechanically treated bars.
35Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coatof approved steel primer after pre-treatment of the surface as directedby Engineer-in-charge:
36Steel work welded in built up Section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc.as required in gratings, framed, guard bar, ladder, relling and gate.
37Providing and fixing of ISI marked 35 mm thick flush door shutter Confirming to IS:2202 (Part-1) decorative bord construction with frame of Ist class hard wood and well matched commercial 3 ply venering with vertical grain or cross band face veneers on both face of shutter.
38Providing and fixing aluminium sliding door bolts ISI marked anodi coating not less than grade AC 10 as per IS : 1868) transparent or colour or shade with nuts and screws etc. complete
39Providing and fixing aluminium handles ISI marked anodised (anod less than grade AC 10 as per IS : 1868) transparent or dyed to req shade with necessary screws etc. complete :
40Providing and fixing aluminium tower bolts ISI marked anodised (a not less than grade AC 10 as per IS : 1868 ) transparent or dyed t or shade with necessary screws etc. complete 150mm long
41Providing and fixing aluminium tower bolts ISI marked anodised (a not less than grade AC 10 as per IS : 1868 ) transparent or dyed t or shade with necessary screws etc. complete 100mm long
4220 mm cement plaster 1:3 finished with a floating coat of neat cement in Dado including all cost of labour material T&P etc for proper complition of work.
4312 mm thick cement plaster 1:6 cement & sand mortar including supply of all labour material andT&P etc required for proper complition of work.
4415 mm thick cement plaster 1:6 cement & sand mortar on rough side including supply of all labour material andT&P etc required for proper complition of work.
454.0 cm thick cement conrete flooring 1:2:4 cement coarse sand and 20 mm aggregate finished with a floting coat of neat cement including cement sullary but excluding the cost of nosing of teps etc.
46Providing and fixing of glaass strips in joints of terrazo/cement conrete floor 40 mm wide and 40 mm thick.
47Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4mm in both directions with wire of dia 0.63 mm all complete.
48Providing and fixing 4.0 mm thick glazing in window, ventilator, shutter and partition etc. with putty as per direction of Engineer in Charge.
49Providing and fixing Ist quality ceramick glazed floor tile 300x300 mm mm tiles confirming to IS: 15622 of approved make in all colour shade except burgundy, bottal green black of any size as approved by Engineer in charge with 1:4 cement and sand mortar I/C all.
50Providing and fixing Ist quality ceramick glazed wall tile mm tiles confirming to IS: 15622 of approved make in all colour shade except burgundy, bottal green black of any size as approved by Engineer in charge with 1:3 cement and sand mortar I/C all.
51Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
52Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
53Providing and fixing water closed squatting pans (Indian type W.C. Pan) with 110 mm sand cast iron P or S trap 10 ltr loe level whte P.V.C. flushing cistern with manually controled divce confirming to IS :7231 with all fittings and fixtures complete including all cutting and making good the walls and floor wherever required
54Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
55Providing and fixing of white vitreous china wash basin size 630x450 mm with C.I. brackets , 15 mm C.P. brass piller taps, 32 mm C.P. brass waste of standerd patterns including all fittings.
56Providing and fixing on wall face unplasticised Rigid PVC rain water conforming to IS : 13592 Type A including jointing with seal ring c 5382 leaving 10 mm gap for thermal expansion, (i) Single sockete
57S/F 15 mm Ø G.I. pipe line complete with G.I. fitting and clamp including supply of all material labour T&P etc.
58S/F 20 mm Ø G.I. pipe line complete with G.I. fitting and clamp including supply of all material labour T&P etc.
59S/F 15 mm Ø C.P. brass bib cock including all material labour T&P etc required for proper complition of work
60S/F 15 mm dia C.P. brass stop cock including all material labour T&P etc required for proper complition of work
61Providing and placing on terrace (at all floor levels) polyethylene w tank ISI : 12701 marked with cover and suitable locking arrangem necessary holes for inlet, outlet and overflow pipes but without fitti base support for tank
62Constructing masonry Chamber 60x45x50 cm, inside with 75 class brick work in cement mortar 1:4(1 cement : 4 coarse sand) for wa
63Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
64Finishing wall with textured exterior paint of required shade with two and more coat applied @3.28ltr/10 Sqm over and including base coat of water proofing cement paint applied 2.20 Kg/10Sqm.
65Providing and applying plaster of peris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
66Distemring with Ist Qualiti Oil Bond washable distemper of approved brand and manufactur to give an even shade.
67Excavation by mechanical means/ manual means in foundation trench or drain (not Exceeding 1.50 m in width or 10 Sqm on plan) including dressing of sides and ramming of bottoms lift up to 1.5 m including getting out the excavated soil and disposal of surplus excvated soil as directed with in lead of 50 m. in all kind of soil.
68Providing and laying in position cement concrete of specified grade excluding cost of centering and shuttering of 1:4:8 with cement coarse sand and 40 mm graded stone in foundation.
69B/Work F.P.S. brick of class designation 75 in foundation and plinth with 1:6 cement and sand mortar including all cost of material labour T&P etc for proper complition of work.
70B/Work F.P.S. brick of class designation 75 in super structure with 1:6 cement and sand mortar including all cost of material labour T&P etc for proper complition of work.
71Providing and laying in position specified grade of reinforcement cement concrete excluding the cost of centering , shuttering finishing and reiforcement all work upto plinth with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)for Columns footing .
72Reinforcement cement concrete work in wall ( Any Thickness) including attached Pilasters, butteresses, plinth, and string course fillet columns, posts, and struts etc, upto floor five level excluding cost of shuttering, centring, finishing and reinforcement1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)for Columns
73Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
74Centring and shuttering including shutterings , ropng , etc and removel from foundation footing bases of columns.
75Centering and shuttering including shuttering ropping etc. and removel from columns piller piers abutments, post and struts.
76Suspended floors, roofs, landings, balconies and access platform.
77Lintels, beams, plinth beams, girders, bressumers and cantilevers.
78Reinforcement for R.C.C. work including straightening, cutting , bending, placing, in postion and binding all comlete for Thermo Mechanically treated bars.
7920 mm cement plaster 1:3 finished with a floating coat of neat cement in Dado including all cost of labour material T&P etc for proper complition of work.
8012 mm thick cement plaster 1:6 cement & sand mortar including supply of all labour material andT&P etc required for proper complition of work.
8115 mm thick cement plaster 1:6 cement & sand mortar on rough side including supply of all labour material andT&P etc required for proper complition of work.
824.0 cm thick cement conrete flooring 1:2:4 cement coarse sand and 20 mm aggregate finished with a floting coat of neat cement including cement sullary but excluding the cost of nosing of teps etc.
83Providing and fixing of glaass strips in joints of terrazo/cement conrete floor 40 mm wide and 40 mm thick.
84Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
85Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
86Finishing wall with textured exterior paint of required shade with two and more coat applied @3.28ltr/10 Sqm over and including base coat of water proofing cement paint applied 2.20 Kg/10Sqm.
87Providing and applying plaster of peris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
88Distemring with Ist Qualiti Oil Bond washable distemper of approved brand and manufactur to give an even shade.
89Excavation by mechanical means/ manual means in foundation trench or drain (not Exceeding 1.50 m in width or 10 Sqm on plan) including dressing of sides and ramming of bottoms lift up to 1.5 m including getting out the excavated soil and disposal of surplus excvated soil as directed with in lead of 50 m. in all kind of soil.
90Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
91Providing and laying in position cement concrete of specified grade excluding cost of centering and shuttering of 1:4:8 with cement coarse sand and 40 mm graded stone in foundation.
92B/Work F.P.S. brick of class designation 75 in foundation and plinth with 1:4 cement and sand mortar including all cost of material labour T&P etc for proper complition of work.
93Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) :Light shade pigment using white cement
94Wiring for light point/ fan point/ exhaust fan point/ call bel point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B
95Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.WGSTLSB Circuit/ submain wiring in pvc conduit:
96Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.
971 or 2 Modules (75 mm X 75 mm)
985/6 A switch
993 pin 5/6 A socket outle
100Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
101Supplying and fixing suitable size GI box with modular plate and cover in front on surfaceor on recss, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
102Supplying and fixing brass batten/ angle holder including connection etc. as required.
103Installation, testing and commissioning of pre wired, fluorescent fitting / compact fluorescent fitting of all types,complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
104Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
105Supplying and fixing following way,single pole and neautral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 Way, Double Door
106Supplying and fixing following rating, Double pole, 240 V, isolator in the existing MCB DB complete with connections , testing and commissioning etc. as required.40 Amps
107Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
108Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
109Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required(Jointing shall be done by overlapping and with 2. sets of G.I. nut bolt & spring washer spaced at 50mm)
110Supplying And Making end Terminal with brass comprasion gland and aluminium lugs for following size of PVC Insulated and PVC Sheeted/XLPE aluminium conductor Cable of 1.1KV grade as required. 2 x 6 sq. mm (19 mm)
111Supply of AC 230/250 Volts, 50 Hz energy efficient ceiling fan with Standard down rod, blades,3 nos.caps Model- ES 50 (1200 MM Sweep) etc. complete, in all aspects as per direction of Engineer in charge.1200 mm Sweep
112Supply and fixing on LED Tube light 1200 mm 20 W 865 T8 IP20, Lumen Output-1600, 3000,4000, 6500K ceiling mounted LED batten (E-Lite LED TRIYACA) extruded aluminium heat sink provided for efficient heat deissipation 7 & integrated electronic driver ( 1x20 W LED Double 6500K) complete in all aspects as per direction of Engineer in charge.
113SUPPLY OF LED Glass Bulb B22, 15 W, 600K / 4000K/3000K, 230/250 volt, 50 HZ etc. complete in all aspects as per direction of Engineer in charge.
114SUPPLY OF LED Ceilling Light B22, 15 W, 600K / 4000K/3000K, 230/250 volt, 50 HZ etc. complete in all aspects as per direction of Engineer in charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58604245
AUTHORITY Government Departments
TENDER VALUE 80.81 Lakhs
LAST DATE 04-12-2026
Authority
Authority Name Irrigation Department
Work Description Tender for Strengthening Work Of The Ancient Temple Located In The Dam Area Under The Legislative Assembly Of Jaspur.
Basic Detail
Tender No 04/2026-27 date 18 Novmber 2026
Bidding Type Tender
Location
City Udam Singh Nagar
State Uttarakhand
Key Dates
Publish Date 19 Nov 2026
Submission Date 04 Dec 2026
Open Date 05 Dec 2026
Finance
Tender Value 80.81 Lakhs
Tender Fee 4720
EMD 1.61 Lakhs
Exemption Available
Document List
0c18d557-2233-4b3d-b3f0-102007b9b6a1.html
BOQ_120795.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Dec 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

0c18d557-2233-4b3d-b3f0-102007b9b6a1.html

xls

BOQ_120795.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender