Project Description

Tender for Renovation And Upgradation Of Tourist Rest House At Khirsu Distt. Pauri

BOQ

Name of Work:- RENOVATION AND UPGRADATION OF TOURIST REST HOUSE AT KHIRSU DISTT. PAURI
Sl. No. Item Description
1Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. in Ordinary rock
2Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
3Supplying chemical emulsion in sealed containers including delivery as specified Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
4Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
5Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
6Providing and laying in position cement concrete 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) of specified grade, excluding the cost of centering and shuttering - All work up to plinth level
7Providing and laying cement concrete 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) in retaining walls, return walls,walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived fromnatural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
8Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columns
9Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5 mm nominal size derived from natural sources)
10Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification.
11Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth
12Providing and laying in position specified grade of reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources), excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
13Reinforced cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
14Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
15Centring and shuttering including strutting, ropping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete.
16Centring and shuttering including strutting, ropping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform.
17Centring and shuttering including strutting, ropping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers.
18Centring and shuttering including strutting, ropping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts.
19Centring and shuttering including strutting, ropping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases.
20Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
21Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
22Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand)
23Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
24Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in Cement mortar 1:4 (1 cement :4 coarse sand)
25Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
2625 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws
27Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25 mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete 25 mm dia
28Providing and fixing ISI marked, IS : 1341, M.S. heavy weight butt hinges with necessary screws etc. complete :125x90x4.00 mm
29Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :250x10 mm
30Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
31Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete.
32Providing and fixing bright finished brass handles with screws etc. complete:125 mm
33Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
34Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
35Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
36Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strikeplate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineerin- charge:Profile C Fixing with adjustable lugs with split end tail to each jamb
37Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
38Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. In M.S. tube
39Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete
40Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
41Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
42Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.
43Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red
44Providing & fixing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately).0.56 mm, Aluminium Colour coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width 1092 mm, cover width 1000 mm.
45Providing and fixing of Pre-coated colour or mill finish Aluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]. For colour, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50 mm with 3 mm thick EPDM seal and SS plain washer complete :Precoated/mill finish aluminium Ridges plain (500- 600mm
46Precoated/mill finish aluminium Gutter (600 mm over all girth)
47Finishing of walls with 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand) complete in all respect.
48Finishing of walls with 6 mm cement plaster of mix 1:3 (1 cement : 3 fine sand) complete in all respect
49Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
50Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
51Polishing on wood work with ready mixed wax polish of approved brand and manufacture : in New work
52Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
53Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface including disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge. For door/ window/ clerestory window
54Dismantling W.C. Pan of all sizes including disposal of dismantled materials including malba all complete as per directions of Engineer-in-Charge.
55Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer in charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
56Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
57Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
58Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below
59Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
60Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
61Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.
62Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
63Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron
64Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
65Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
66Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete.Polyester powder coated minimum thickness 50 micron aluminium
67Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS : 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
68Providing and fixing white vitreous china pedestal type water closet floor mounted (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
69Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe 32mm dia
70Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
71Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade
72Providing and fixing unplasticised PVC connection pipe with brass unions.45 cm length, 15 mm nominal bore
73Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean & Wall moutain type W.C. of quality and make as approved by Engineer - in - charge.
74Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931a) 15 mm nominal bore
75Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (For bath) 15 mm diameter
76Providing and fixing C.P. brass shower rose with 15 or 20mm inlet. 150 mm diameter
77Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
78Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
79Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms.
80Providing & fixing soil, waste and vent pipes. Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905a) 100mm dia centrifugally cast iron S & S pipe.
81Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc. ( for wash basin waste ) 32mm dia nominal bore
82Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe. a) 100mm SS 304 grade coupling with EPDM rubber gasket
83Providing & fixing cast iron coller.a) 100mm dia complete in all respect.
84Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : a) 100mm inlet & 100mm outlet.
85Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 100mm
86Providing and fixing plain bend of required degree.Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 100mm
87Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100x100x100mm
88Providing and fixing centrifugaly cast iron single equal plain junction of required degree.100x100x100mm
89Providing and fixing single unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete : 100x100x75mm
90Providing and fixing single unequal plain invert branch of required degree : 100x100x75mm
91Providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete :( c.o.p.) a) 100mm
92Providing and fixing cast iron terminal guard.100 mm
93Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size) around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) 110 mm dia
94Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion.110 mm
95Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. 110 mm Bend
96Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
97Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm
98Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.
99Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. 25mm dia nominal outer dia pipes
100Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work-Exposed on wall 20mm dia nominal bore
101Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work-Exposed on wall 25mm dia nominal bore
102Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work-Exposed on wall 32mm dia nominal bore
103Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work-Exposed on wall 40mm dia nominal bore
104Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work-Exposed on wall 50mm dia nominal bore
105Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work-Exposed on wall 65mm dia nominal bore
106Providing and fixing gun metal gate valve with wheel of approved quality. 20mm dia nominal bore
107Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore
108Providing & fixing white vitreous china Under Counter wash basin with C.I. brackets painted white, with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required. a)White Vitreous China Wash basin size (605x410x200)mm Jaquar (FNS-WHT-40701)
109Central Hole Basin Mixer with Popup Waste System with 450mm LongBraided Hoses (CQT-23169B jaguar)
110Sink Mixer with Swinging Spout (Table Mounted Model) with 450mm Long Braided Hoses (CQT-23309B jaguar)
111Providing and fixing Sintes Tank with Puf insulation with MS Stand Hevvy Duty
112Providing and fixing Electric water heater with Puf insulation cap 25 lts Toilet
113Providing and fixing Electric water heater with Puf insulation cap 25 lts kitchen
114Supply of wall hanging drinking online water cooler with bottle filler facility, made by stainless steel top and heavy duty galvanized steel frame. With cooling capacity, ADA Compliant, size 472 mm Depth X 447mm width, flexible bubbler guard , operated between 50 to 120 PSI, Chiller unit Suitable to R134a Refrigerant, Adjustable thermostat control, suitable for 220-230v/50-60 hz A/C Supply Complete with all accessories which include MD-CU29, which is an EPA registered antimicrobial copper that fights off microorganisms which include MRSA and e-coli. The water Fountain shall possess NSF-USA, Green building, energy star saving certification, and to be placed at different location of buidling. As per Enginner Incharge- Make Oasis/ Filtrin/ Eureka Forbes
115Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m.1.50 m depth Pipes 80 mm to 300 mm diameter
116Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) Depth not exceeding 1.5 meter
117Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 150 mm. dia. RCC Pipes
118Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 250 mm. dia. RCC Pipes
119Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm. dia.
120Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 400 mm. dia.
121Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
122Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With common burnt clay FPS (non modular) bricks of class designation 75
123Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cementm concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :
124Providing and fixing Square- mouth SW gully trap class SP-1 Complete with CI Grating brick masonry chamber with water tight CI Cover with frame of 300 X 300mm size (inside) the weight of cover to be not less than 4.50kg and frame to be not less than 2.70kg as per standard design. 100 x 100 mm size P type with common burnt clay F.P.S(non modular) brick of class designation 7.5
125Providing and laying in position specified grade of reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources), excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
126Profile E Fixing with adjustable lugs with split end tail to each jamb
127Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
128Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead complete in all respect.
129Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.Ref. Plinth Area (9.92X5.33 = 52.87 Sqm.) @15kg/Sqm.complete in all respect.
130Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of complete in all respect.
131Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead.Ref. Plinth Area (9.92X5.33 = 52.87 Sqm.) @5.00 Sqm on plinth Area complete in all respect.
132Providing and fixing Brass 100 mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete in all respect.
133Providing and fixing 18mm Thick HPL Single Side Decor a high-quality exterior grade decorative HPL Decor compact laminate panel for constructive building exteriors with EN438- Part 6. Made under high pressure and high temperature. Special protective film on the upper surface provides excellent UV resistance, which protects the panels from harsh solar rays and other extreme weather conditions, including heavy rain, acid rain, hail and heat. Underneath the design layer, double hardened resins are used to protect the HPL Decor panels from corrosion caused by natural elements. This involves necessary cutting and extensive preparation etc. complete.
134Providing and fixing 6mm Thick HPL Single Side Decor a high-quality interior grade decorative HPL Decor compact laminate panel for constructive building interior with EN438- Part 6. Made under high pressure and high temperature. Special protective film on the upper surface provides excellent UV resistance, which protects the panels from harsh solar rays and other extreme weather conditions, including heavy rain, acid rain, hail and heat. Underneath the design layer, double hardened resins are used to protect the HPL Decor panels from corrosion caused by natural elements. This involves necessary cutting and extensive preparation etc. complete.
135Providing and fixing 80mm Thick doubule sink PUF insulated galvanume sheet for sloping roof excluding the cost of purlins, rafters and trusses and including cutting to size, shape wherever required and T&P etc.
136Providing and fixing 10x10x7.50 cm cobble stone on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge.
137Wiring for light point/ fan ponit/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
138Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
139Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, 2 way modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc
140Wiring for light/ power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
141Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. - 2X1.5 sq.mm. + 1X 1.5 sq.mm earth wire
142Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. -2X2.5 sq.mm. + 1X 2.5 sq.mm earth wire
143S/L following 2 pair, 0.5 sq mm FRLS PVC insulated copper conductor, unarmoured telephone cable in the existing PVC conduit as required.
144S/F of following sizes of PVC conduit along with accessories in surface/recess including cuttting the wall and making good the same (20mm)
145S/F of following sizes of PVC conduit along with accessories in surface/recess including cuttting the wall and making good the same (25mm)
146S/F suitable size Gl box with modular plate and cover in Front on surface or in recess, including providing and flxing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required
147S/F suitable size GI box with modular plae and cover in FRLSont on surface or in recess, including providing and flxing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required.
148Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
149Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. (for geyser/oil heater)
150S/F following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
151S/F following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
152S/F following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
153Supply and fixing of following size/ modules, GI box along with modular base & cover plate for modular switch/ regulator in recess, including connection as required. -1or 2 module (75mmx 75mm)
154Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep.
155Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
156S/F 5 amps to 32 amps rating, 240 volts, 'C' series, miniature circuit breaker suitable for lighting and other loads Single pole and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required. -Single Pole
157Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
158Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
159Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required -63 A
160Supplying and fixing following rating, Four pole, (Three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 A
161Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator 4 way (4+12) , Double door
162Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/ RCCB / Isolator 8 way (4+24) , Double door
163Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) in the existing MCB DB complete etc.
164Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required
165LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt ) Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As perANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \\"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector 8 - 10 watt
166Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulatorfor speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/cexternal connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 210 CM/Min (Minimum)
167Earthing with G.I. earth Plate 600mm x 600mm x 6mm thick including accesssories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt as required.
168Providing and fixing 25 mm x 5 mm GI strip in 40 mm dia GI pipe from earth electrode including connection with brass nut , bolt , spring , washer , excavation and re filling etc. as required.
169Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.
170Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
171Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
172Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
173Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
174Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet orsurface of wall for lightning conductor complete asrequired.(For vertical run)
175Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required 2 x 1.5 sq. mm
176Supplying of Linear & compact 9W,4000 K (NW) mirror light with decorative grey end caps, polycarbonate body and ribbed opal diffuser Or as approved by the architect as per site condition
177Supplying & fixing of 250 mm sweep, 230V Exhaust Fan (PVC) complete in all respect and as per direction of E/I
178Supply, installation, testing and comissioning of 21\\" LED Monitor for Observation and reviewing complete in all respect and as per direction of E/I
179Supply and laying of following sizes of XLPE insulated Aluminum/Copper conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications. 4C 10 sq mm Al. Ar. Cable complete in all respect and as per direction of E/I
180Supply and laying of following sizes of XLPE insulated Aluminum/Copper conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications. 4C 25 sq mm Al. Ar. Cable complete in all respect and as per direction of E/I
181Supply and laying of following sizes of XLPE insulated Aluminum/Copper conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications. 3.5C 50 sq mm Al. Ar. Cable complete in all respect and as per direction of E/I
182Supply and laying of following sizes of XLPE insulated Aluminum/Copper conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications. 3.5C 120 sq mm Al Ar. Cable complete in all respect and as per direction of E/I
183Design, Fabrication, Supply, Erection,Testing and commisioning of Powder coated Main Distribution Panel fabricated out of 14 guage CRCA sheet steel in cubical, compartmentallised, free standing floor /wall mounted, dust and vermin proof, with reinforcement of suitable size angle iron, channel, T -iron or flats as required. Cable gland plates shall be provided on top as well as bottom of the panels. Panels shall be treated with all anti-corrosive process before painting as per specification. Panels shall be suitable for 415V, 3-Phase, Four wire, 50 Hz supply complete with earth bus and lifting hooks as required in case of large panels.Approval shall be taken for each panel before fabrication by submiiting the GA drawings to the consultant/engineer in charge . (All hardwares like nuts and bolts used shall be Galvanized and Zinc passivated). MAIN LT PANEL INCOMER 315 A, FP, MCCB ,35 KA for Mains - 1 No.200 A, FP, MCCB ,35 KA for Servo - 2 No. 63 A, FP, MCCB ,35 KA for Solar- 2 No.150 A, FP, MCCB ,35 KA for DG Set - 1 No. METERING & INDICATION with each incomer : 3 sets - ON/OFF phase indicating lamps with control fuses .Multi Function Meter : measuring of V, A, F, PF, kW, kWh, etc. Changeovers 200 A, FP, ATS for Mains & DG - 1 No.200 A, FP, ATS for Mains & Solar - 1 No.200 A, FP, Onload Changeover for Servobypass - 1 No. BUS BAR-as per SLD - 250 A, TPN, Al Bus Bars with heat shrinkable PVC Sleeves OUTGOINGS - 100A, FP, MCCB, – 1 N.o.- 63 A, FP, MCB, – 8 N.o. complete in all respect and as per direction of E/I
184Design, Fabrication, Supply, Erection,Testing and commisioning of Powder coated Feeder Pillar Panel fabricated out of 14 guage CRCA sheet steel in cubical, compartmentallised, free standing floor /wall mounted, dust and vermin proof, with reinforcement of suitable size angle iron, channel, T -iron or flats as required. Cable gland plates shall be provided on top as well as bottom of the panels. Panels shall be treated with all anti-corrosive process before painting as per specification. Panels shall be suitable for 415V, 3-Phase, Four wire, 50 Hz supply complete with earth bus and lifting hooks as required in case of large panels.Approval shall be taken for each panel before fabrication by submiiting the GA drawings to the consultant/engineer in charge . (All hardwares like nuts and bolts used shall be Galvanized and Zinc passivated). COTTAGE FEEDER PILLAR ( Outdoor Type) INCOMER 250 A, FP, MCCB ,35 KA - 1 No.METERING & INDICATION with each incomer - ON/OFF phase indicating lamps with control fuses .Multi Function Meter : measuring of V, A, F, PF, kW, kWh, etc.out going 63 / 100 Amp out going MCCB -3 Nos for light load and 150 Amp out going MCCB - 2 Nos for power load complete in all respect and as per direction of E/I
185Supply Installation Testing and Commisioning of 90 KVA ONAN Cooled Servo Stabilizer as per specification below Phase : 3 ph input /3 ph output Input Voltage range : 280 V to 480 V / Output Voltage range : 400V +/- 1 Input Frequency : 45 to 55 Hz / Output Frequency : 50 Hz , Cooling: ONAN . High & Low Voltage Cutoff System Over Load . complete in all respect and as per direction of E/I
186Supply,Installation, testing & Commissioning of 100 KVA Silent DG set comprising of Suitable Engine coupled to 415V 100 KVA alternator with change over switch for suitable size both mounted on common Base frame with other standard accessories i.e. Fuel tank, Batteries with leads. along with standard panel . (for detailed specification please ref to General Specifications for Electrical Works, PART -VII DG SETS,2013,CPWD Document.) CPCB-IV Approved make Kirloskar / Mahindra comings / Eicher / equivalent complete in all respect and as per direction of E/I
187Supply of 5 mtr galvanised Octagonal Pole with base plate 200 X 200X 12,top 70mm & bottom 130mm made up of 3mm thik suitable for max. wind speed upto 160 Km/hr. Poles with Single bracket (1000 mm) including Post Top Light complete in all respect and as per direction of E/I
188Making, Supply and fixing of 1800x1800 mm second class teak wood double bed without storage box including matching side tables complete in all respect as per approved / direction of Higher Authority (MD/ GM(C)1) Size: 1800x1800 mm. This is the mattress size.2) Second class Teak Wood with kharad and chul surag joining.3) Without Box Storage.4) The pillars of the bed will be teak wood and will be carved outof 4 inches by 4 inches square wood.5) The side support will of teak wood, the thickness of the woodwould be 1.5 inches by 3 inches. 6) The bed will be given a walnut semi gloss finish. Melaminepolish would be applied as a top coat.7) All work should be completed in all respect.
189Making, Supply and fixing of 1800x1000 mm second class teak wood twin bed without storage box including matching side tables complete in all respect as per approved / direction of Higher Authority. 1) Size: 1800x1000 mm. This is the mattress size.2) Second class Teak Wood with kharad and chul surag joining.3) Without Box Storage.4) The pillars of the bed will be teak wood and will be carved outof 4 inches by 4 inches square wood.5) The side support will of teak wood, the thickness of the woodwould be 1.5 inches by 3 inches. 6) The bed will be given a walnut semi gloss finish. Melaminepolish would be applied as a top coat.7) All work should be complete in all respect.
190Making, Supply and fixing Balcony Sitout Chairs + Table Set In outdoor wicker material complete in all respect.
191Making, Supply and fixing of Cupboard + TV Cabinet + Electric Kettle Unit in 2000x600x2100
192Making, Supply and fixing of Lounge Sofa 2500x850 + Table In wood and sofa fabric Reception complete in all respect
193Making, Supply and fixing of Reception Table / Counter 1800x600 In pine wood planks complete in all respect.
194Making, Supply and fixing of 6 Seater Dining Table Set 1200mm x1800mm x 750mm (WxDxH) In pine wood with matching chair including sit and back area covered by foam & fabric complete in all respect and as per direction of E/I
195Making, Supply and fixing of 4 Seater Dining Table Set 1200 mm x1200mmx 750mm (WxDxH) in pine wood with matching including sit and back area covered by foam & fabric complete in all respect and as per direction of E/I
196Making, Supply and fixing of Dormitory Single Bed 900x1800 with side table in pine wood
197Making, Supply and fixing of Dormitory Cupboard 750x600x2100 In Laminated HDHMR complete in all respect.
198Making, Supply and fixing of Dormitory Balcony Sitout Chairs + Table Set In outdoor wicker material
199Making, Supply and fixing of Dining Drawer Unit 2400x450 made of SS Grade 304 frame with granite top complete in all respect and as per direction of E/I
200Making, Supply and fixing of Twin Sofa with Table 2000x850 In pine wood complete in all respect.
201Making, Supply and fixing of Balcony Sitout Chairs + Table Set In outdoor wicker material complete in all respect
202Making, Supply and fixing of TV Cabinet In Laminated HDHMR complete in all respect.complete in all respect
203Making, Supply and fixing of Cupboard + TV Cabinet + Electric Kettle Unit in 1200x600x2100 In Laminated HDHMR complete in all respect
204Supply and fixing of stock pot ( 24\\"x24\\"x24\\") complete in all respect
205Supply and fixing of Two Burner Range ( 48\\"x24\\"x34\\") complete in all respect
206Supply and fixing of work table with 2 under shelves ( 60\\"x24\\"x34\\") complete in all respect
207Supply and fixing of Bain Marie with 5 G N pans with curved glass complete in all respect
208Supply and fixing of storage Rack (5 shelves) complete in all respect
209Supply and fixing of three sink unit (60\\"x24\\"x34\\") complete in all respect.
210Supply and fixing of Plate rack (60\\"x14\\"x18\\") complete in all respetc
211Supply and fixing of Exhaust Hood for Burner / Chapati (102\\"x30\\"x22\\") complete in all respect
212Supply and fixing of sandwitch griller complete in all respect.
213Supply and fixing of Toaster for 12 toast complete in all respetct
214Supply and fixing of Gas pipe line with maniforl STANDARD complete in all respect
215Supply and fixing of GI Ducting STANDARD complete in all respect.
216Supply and fixing of Exhaust Fan ( 450 - 500 mm ) for kitchen complete in all respect.
217Supply and fixing of Fly Catcher (STANDARD) complete in all respect
218Supply and fixing of 30\\"x30\\"x22\\" Exhaust Hood for stock pot complete in all respect.
219Supply and fixing of Tea/Coffee/Soup Dispencer STANDARD complete in all respect.
220Supply and fixing of Multipurpose Table 60\\"x30\\"x34\\" complete in all respect. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58603331
AUTHORITY Local Bodies
TENDER VALUE 3.68 Crore
LAST DATE 10-12-2026
Authority
Authority Name Garhwal Mandal Vikas Nigam Limited
Work Description Tender for Renovation And Upgradation Of Tourist Rest House At Khirsu Distt. Pauri
Basic Detail
Tender No GMVN- ENGG-KRSUUPG
Bidding Type Tender
Location
City Pauri Garhwal
State Uttarakhand
Key Dates
Publish Date 18 Nov 2026
Submission Date 10 Dec 2026
Open Date 10 Dec 2026
Finance
Tender Value 3.68 Crore
Tender Fee 5900
EMD 7.36 Lakhs
Exemption Not Available
Document List
47d88ed3-25c1-4b44-9811-90132f3e85b7.html
BOQ_120799.xls
khirdc1.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Dec 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

47d88ed3-25c1-4b44-9811-90132f3e85b7.html

xls

BOQ_120799.xls

pdf

khirdc1.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender