Tender For Repair/Replacement Of Old Aluminum Wiring Infrastructure And Connected Items At Afsk.
Tender Value
45 Lakhs
Estimated cost
Bid Submission
08 Dec 2026
15 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kanpur Nagar → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Replacement Of Old Aluminum Wiring Infrastructure And Connected Items At Afsk.
BOQ
| Sl. No. | Item Description |
| 1 | Material and labour for taking down old unserviceable/deteriorated batten/PVC conduit point wiring of light, fan, socket or power points from the existing place, with all unserviceable fittings such as switches, sockets, ceiling roses, pendants and holders, and making good all disturbed surfaces of wall, floor etc. with cement mortar 1:3 or plaster of Paris as suitable , and matching/finishing the new surface with the existing surface using distemper, putty or white/colour wash of the same colour, complete all as specified and directed by Engineer-in-Charge. |
| 2 | Material and labour for concealed point wiring on wall and surface wiring on ceiling/roof for piano type switches and sockets, with necessary fixing arrangements, with PVC insulated FRLSH unsheathed multi-stranded copper conductor cable of size 1.5 sqmm, 1100 V grade, conforming to IS 694, drawn in and including rigid non-metallic white/ivory PVC conduit, medium grade, ISI marked, of not less than 20 mm dia, conforming to IS 9537 Part 3, with all conduit accessories and fittings such as junction boxes, bends, tees and elbows, including anodised MS sunken boxes made of MS sheet not less than 1.5 mm thick with earth dolly and ISI marked bakelite laminated sheet 3 mm thick for fixing of switches, sockets, fan regulators, wall mounting fittings, door bell and bulkhead fittings with MS screws and cup washers, including PVC insulated FRLSH unsheathed multi-stranded copper conductor cable of size 1.5 sqmm, 1100 V grade, as continuous earth conductor, including cutting chases and making good the surface with cement mortar 1:3 and matching/finishing the new surface with plaster of Paris/putty or distemper/colour wash to the existing colour, including testing, for one light, fan or call bell point complete all as specified and directed by Engineer-in-Charge. |
| 3 | All as per item No. 2 above but for one socket point controlled by one switch on independent board complete all as specified and directed by Engineer-in-Charge. |
| 4 | All as per item No. 2 above but for one socket point controlled by one switch on the same board complete all as specified and directed by Engineer-in-Charge. |
| 5 | All as per item No. 2 above but for one power point with 2.5 sqmm cables for phase and neutral and one 2.5 sqmm cable as continuous earth conductor complete all as specified and directed by Engineer-in-Charge. |
| 6 | Material and labour for surface point wiring on wall and ceiling/roof with necessary fixing arrangements, with PVC insulated FRLSH unsheathed multi-stranded copper conductor cable of size 1.5 sqmm, 1100 V grade, conforming to IS 694, drawn in and including white/ivory PVC casing and capping of size 20 mm or 25 mm with all accessories and fittings such as junction boxes, bends, tees and elbows, including PVC/polycarbonate gang box of size to suit the switches and sockets for fixing of switches, sockets, fan regulators, door bell and bulkhead fittings with MS screws and cup washers, including PVC insulated FRLSH unsheathed multi-stranded copper conductor cable of size 1.5 sqmm, 1100 V grade, as continuous earth conductor, including testing, for one light, fan or call bell point complete all as specified and directed by Engineer-in-Charge. |
| 7 | All as per item No. 6 above but for one socket point controlled by one switch on independent board complete all as specified and directed by Engineer-in-Charge. |
| 8 | All as per item No. 6 above but for one socket point controlled by one switch on the same board complete all as specified and directed by Engineer-in-Charge. |
| 9 | All as per item No. 6 above but for one power point with 2.5 sqmm cables for phase and neutral and one 2.5 sqmm cable as continuous earth conductor complete all as specified and directed by Engineer-in-Charge. |
| 10 | Material and labour for concealed point wiring on wall and surface wiring on ceiling/roof for modular switches and sockets, with necessary fixing arrangements, with PVC insulated FRLSH unsheathed multi-stranded copper conductor cable of size 1.5 sqmm, 1100 V grade, conforming to IS 694, drawn in and including rigid non-metallic white/ivory PVC conduit, medium grade, ISI marked, of not less than 20 mm dia, conforming to IS 9537 Part 3, with all conduit accessories and fittings such as junction boxes, bends, tees and elbows, including PVC insulated FRLSH unsheathed multi-stranded copper conductor cable of size 1.5 sqmm, 1100 V grade, as continuous earth conductor, including cutting chases and making good the surface with cement mortar 1:3 and matching/finishing the new surface with plaster of Paris/putty or distemper/colour wash to the existing colour, including testing, for one light, fan, exhaust fan or call bell point complete all as specified and directed by Engineer-in-Charge. |
| 11 | All as per item No. 10 above but for one socket point controlled by one switch on independent board complete all as specified and directed by Engineer-in-Charge. |
| 12 | All as per item No. 10 above but for one socket point controlled by one switch on the same board complete all as specified and directed by Engineer-in-Charge. |
| 13 | All as per item No. 10 above but for one power point with 2.5 sqmm cables for phase and neutral and one 2.5 sqmm cable as continuous earth conductor complete all as specified and directed by Engineer-in-Charge. |
| 14 | Material and labour for piano type flush switch, single pole one way, 6 A, 240 V, white finish, conforming to IS 3854 complete all as specified and directed by Engineer-in-Charge. |
| 15 | Material and labour for piano type flush switch, single pole, 16 A, 240 V, white finish, conforming to IS 3854 complete all as specified and directed by Engineer-in-Charge. |
| 16 | Material and labour for socket outlet, 3 pin, 6 A, flush type, white finish, conforming to IS 1293 complete all as specified and directed by Engineer-in-Charge. |
| 17 | Supply and fixing of socket outlet, 2 in 1, 3 pin, 6 A/16 A, universal flush type, 240 V, white finish, conforming to IS 1293 complete all as specified and directed by Engineer-in-Charge. |
| 18 | Supply and fixing of bell push, universal flush type, 240 V, white finish complete all as specified and directed by Engineer-in-Charge. |
| 19 | Supply and fixing of ceiling rose, surface type, bakelite, 65 mm x 20 mm, 3 terminal complete all as specified and directed by Engineer-in-Charge. |
| 20 | Supply and fixing of rotary fan regulator, 5 step type, 120 V to 230 V, white finish complete all as specified and directed by Engineer-in-Charge. |
| 21 | Material and labour for modular flush type switch, single pole one way, 6 A, 240 V, white finish, conforming to IS 3854 complete all as specified and directed by Engineer-in-Charge. |
| 22 | Material and labour for modular flush type switch, single pole, 16 A, 240 V, white finish, conforming to IS 3854 complete all as specified and directed by Engineer-in-Charge. |
| 23 | Material and labour for modular socket outlet, 3 pin, 6 A, flush type, white finish, conforming to IS 1293 complete all as specified and directed by Engineer-in-Charge. |
| 24 | Supply and fixing of modular socket outlet, 2 in 1, 3 pin, 6 A/16 A, universal flush type, 240 V, white finish, conforming to IS 1293 complete all as specified and directed by Engineer-in-Charge. |
| 25 | Supply and fixing of modular bell push, universal flush type, 240 V, white finish complete all as specified and directed by Engineer-in-Charge. |
| 26 | Supply and fixing of modular rotary fan regulator, 5 step type, 2 module, 120 V to 230 V, white finish complete all as specified and directed by Engineer-in-Charge. |
| 27 | Supply and fixing of modular angle lamp holder, 6 A, 240 V complete all as specified and directed by Engineer-in-Charge. |
| 28 | Supply and fixing in replacement of modular rotary fan regulator, 5 step type, 2 module, 120 V to 230 V, white finish, including taking down the old unserviceable regulator complete all as specified and directed by Engineer-in-Charge. |
| 29 | Supply and fixing in replacement of electric bell, ding dong type, 240 V complete all as specified and directed by Engineer-in-Charge. |
| 30 | Supply and fixing in replacement of modular metal flush box, 1 or 2 module complete all as specified and directed by Engineer-in-Charge. |
| 31 | Supply and fixing in replacement of modular metal flush box, 3 module complete all as specified and directed by Engineer-in-Charge. |
| 32 | Supply and fixing in replacement of modular metal flush box, 6 module complete all as specified and directed by Engineer-in-Charge. |
| 33 | Supply and fixing in replacement of modular metal flush box, 8 module complete all as specified and directed by Engineer-in-Charge. |
| 34 | Supply and fixing in replacement of modular metal flush box, 12 module complete all as specified and directed by Engineer-in-Charge. |
| 35 | Supply and fixing in replacement of modular white cover plate with frame, 1/2 module complete all as specified and directed by Engineer-in-Charge. |
| 36 | Supply and fixing in replacement of modular white cover plate with frame, 3 module complete all as specified and directed by Engineer-in-Charge. |
| 37 | Supply and fixing in replacement of modular white cover plate with frame, 6 module complete all as specified and directed by Engineer-in-Charge. |
| 38 | Supply and fixing in replacement of modular white cover plate with frame, 8 module complete all as specified and directed by Engineer-in-Charge. |
| 39 | Supply and fixing in replacement of modular white cover plate with frame, 12 module complete all as specified and directed by Engineer-in-Charge. |
| 40 | Supply and fixing in replacement of double door sheet metal enclosure for MCB distribution board, SPN, 8 way, 240 V, with 200 A rated bus bar, fixed on surface or in concealed position, including flexible conduit of size to suit the cables/wires at all exposed portions near the distribution board, complete all as specified and directed by Engineer-in-Charge. |
| 41 | All as per item No. 40 above but 4 way complete all as specified and directed by Engineer-in-Charge. |
| 42 | Supply and fixing in replacement of double door sheet metal enclosure for MCB distribution board, TPN, 4 way, 415 V, horizontal type, with 200 A rated bus bar, suitable for TPN MCB/4 pole isolator, fixed on surface or in concealed position, including flexible conduit of size to suit the cables/wires at all exposed portions near the distribution board, and taking down the old unserviceable TPN distribution board enclosure complete all as specified and directed by Engineer-in-Charge. |
| 43 | Supply, fixing, testing and commissioning in replacement of MCB, single pole, 240 V, 6 A to 32 A, 10 kA, C curve, conforming to IS/IEC 60898-1, connected with lugs of size to suit the cable, fixed in the existing distribution board complete all as specified and directed by Engineer-in-Charge. |
| 44 | All as per item No. 43 above but single pole, 40 A to 63 A complete all as specified and directed by Engineer-in-Charge. |
| 45 | All as per item No. 43 above but SPN, 32 A complete all as specified and directed by Engineer-in-Charge. |
| 46 | All as per item No. 43 above but SPN, 40 A to 63 A complete all as specified and directed by Engineer-in-Charge. |
| 47 | All as per item No. 43 above but triple pole, 415 V, 40 A to 63 A complete all as specified and directed by Engineer-in-Charge. |
| 48 | All as per item No. 43 above but TPN, 415 V, 40 A to 63 A complete all as specified and directed by Engineer-in-Charge. |
| 49 | Supply and fixing in replacement of sheet metal enclosure, 20 A, single pole and neutral, with 2 pin and earth plug and socket, in metal clad board, fixed on surface or in concealed position complete all as specified and directed by Engineer-in-Charge. |
| 50 | Supply and fixing of modular enclosure with 20 A single pole MCB and 2 pin and earth plug and socket, fixed on surface or in concealed position complete all as specified and directed by Engineer-in-Charge. |
| 51 | Material and labour for sub main wiring with two single core PVC insulated FRLS unsheathed multi-stranded copper conductor cables of size 2.5 sqmm, 1100 V grade, conforming to IS 694, drawn in new or existing MS/PVC conduit, with one 2.5 sqmm PVC insulated FRLS unsheathed multi-stranded copper conductor cable as continuous earth conductor, complete with all fixing accessories such as couplers, lock nuts, saddles and pipe hooks, including taking down the old unserviceable sub main wiring complete all as specified and directed by Engineer-in-Charge.Note 1: Two single core cables and one run of earth conductor shall be measured and paid as one unit length.Note 2: PVC conduit, where required, shall be measured and paid separately under the respective item. |
| 52 | Material and labour for sub main wiring with two single core PVC insulated FRLS unsheathed multi-stranded copper conductor cables of size 2.5 sqmm, 1100 V grade, conforming to IS 694, drawn in and including PVC casing and capping of size to suit the cables with all accessories, fixed on wall/floor surface, with one 2.5 sqmm PVC insulated unsheathed multi-stranded copper conductor cable, 1100 V grade, as earth continuity conductor connected to the common earth dolly, including taking down the old unserviceable wiring complete all as specified and directed by Engineer-in-Charge.Note: Two single core cables, one run of earth conductor and one run of PVC casing and capping shall be measured and paid as one unit length. |
| 53 | Material and labour for sub main wiring with two single core PVC insulated FRLS unsheathed multi-stranded copper conductor cables of size 4 sqmm, 1100 V grade, conforming to IS 694, drawn in new or existing MS/PVC conduit, with one 4 sqmm PVC insulated FRLS unsheathed multi-stranded copper conductor cable as continuous earth conductor, complete with all fixing accessories such as couplers, lock nuts, saddles and pipe hooks, including taking down the old unserviceable sub main wiring complete all as specified and directed by Engineer-in-Charge.Note 1: Two single core cables and one run of earth conductor shall be measured and paid as one unit length.Note 2: PVC conduit, where required, shall be measured and paid separately under the respective item. |
| 54 | Material and labour for sub main wiring with two single core PVC insulated FRLS unsheathed multi-stranded copper conductor cables of size 4 sqmm, 1100 V grade, conforming to IS 694, drawn in and including PVC casing and capping of size to suit the cables with all accessories, fixed on wall/floor surface, with one 4 sqmm PVC insulated unsheathed multi-stranded copper conductor cable, 1100 V grade, as earth continuity conductor connected to the common earth dolly, including taking down the old unserviceable wiring complete all as specified and directed by Engineer-in-Charge.Note: Two single core cables, one run of earth conductor and one run of PVC casing and capping shall be measured and paid as one unit length. |
| 55 | Material and labour for sub main wiring with two single core PVC insulated FRLS unsheathed multi-stranded copper conductor cables of size 6 sqmm, 1100 V grade, conforming to IS 694, drawn in new or existing MS/PVC conduit, with one 6 sqmm PVC insulated FRLS unsheathed multi-stranded copper conductor cable as continuous earth conductor, complete with all fixing accessories such as couplers, lock nuts, saddles and pipe hooks, including taking down the old unserviceable sub main wiring complete all as specified and directed by Engineer-in-Charge.Note 1: Two single core cables and one run of earth conductor shall be measured and paid as one unit length.Note 2: PVC conduit, where required, shall be measured and paid separately under the respective item. |
| 56 | Material and labour for sub main wiring with two single core PVC insulated FRLS unsheathed multi-stranded copper conductor cables of size 6 sqmm, 1100 V grade, conforming to IS 694, drawn in and including PVC casing and capping of size to suit the cables with all accessories, fixed on wall/floor surface, with one 6 sqmm PVC insulated unsheathed multi-stranded copper conductor cable, 1100 V grade, as earth continuity conductor connected to the common earth dolly, including taking down the old unserviceable wiring complete all as specified and directed by Engineer-in-Charge.Note: Two single core cables, one run of earth conductor and one run of PVC casing and capping shall be measured and paid as one unit length.Make: Polycab/Grandlay/Gloster/Finolex or equivalent approved by Engineer-in-Charge. |
| 57 | Supply and fixing in replacement of rigid non-metallic white/ivory PVC conduit, medium grade, ISI marked, of 20 mm dia, conforming to IS 9537 Part 3, in concealed position, including all fittings such as tees, bends, reducers, elbows, bell mouths and tube ends and all fixing accessories such as couplers, lock nuts, saddles and pipe hooks, including cutting chases and making good the disturbed surface to match the existing colour of wall/floor, and taking down the old broken PVC conduit complete all as specified and directed by Engineer-in-Charge. |
| 58 | All as per item No. 57 above but of 25 mm dia complete all as specified and directed by Engineer-in-Charge. |
| 59 | Material and labour in repairs for service cable, PVC insulated and PVC sheathed weatherproof, twin core, aluminium solid conductor, 6 sqmm complete all as specified and directed by Engineer-in-Charge. |
| 60 | All as per item No. 59 above but 4 sqmm complete all as specified and directed by Engineer-in-Charge. |
| 61 | All as per item No. 59 above but 10 sqmm complete all as specified and directed by Engineer-in-Charge. |
| 62 | Material and labour in replacement of 3 core PVC insulated and PVC sheathed flexible copper conductor cable of size 2.5 sqmm, 1100 V grade, conforming to IS 694, including taking down the old unserviceable flexible cable complete all as specified and directed by Engineer-in-Charge. |
| 63 | All as per item No. 62 above but of size 1.5 sqmm complete all as specified and directed by Engineer-in-Charge. |
| 64 | All as per item No. 62 above but of size 1.0 sqmm complete all as specified and directed by Engineer-in-Charge. |
| 65 | Material and labour in replacement of XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 V grade, conforming to IS 7098 Part 1, 10 sqmm, 2 core, laid in trenches/on panel or drawn through pipe, including connecting with lugs, nuts and bolts of size to suit the cable, and testing complete all as specified and directed by Engineer-in-Charge. |
| 66 | All as per item No. 65 above but 4 core complete all as specified and directed by Engineer-in-Charge. |
| 67 | Supply and fixing in replacement of energy saving LED light fitting, 40 W, 230 V, single tube mounting type, including LED tube/LED blocks of 40 W with lumen output not less than 100 lm/W, rated life 50000 burning hours, power factor not less than 0.95, complete with electronic driver, LED printed circuit board, end covers, connector box and accessories, prewired, including fixing arrangements and electrical connection with three core copper cable from ceiling rose to the fitting, and removing the old unserviceable tube light fitting complete all as specified and directed by Engineer-in-Charge. |
| 68 | Supply and fixing in replacement of energy saving LED batten, 4 ft, 20 W to 22 W, with nominal system lumen output of 2500 lumen and minimum system efficacy of 110 lm/W, rated system life of 40000 burning hours at L70, colour temperature 6500 K, CRI more than 80, IP 20, THD less than 10 % and power factor more than 0.95, with extruded aluminium housing and polycarbonate glossy diffuser, including fixing arrangements and electrical connection with three core copper cable from ceiling rose to the fitting, and removing the old unserviceable fitting complete all as specified and directed by Engineer-in-Charge. |
| 69 | Supply and fixing in replacement of energy saving LED smart batten fitting, box type, 10 W, 230 V, with all accessories, including fixing arrangements and electrical connection with three core copper cable from ceiling rose to the fitting, and removing the old unserviceable bracket fitting with sketch fitting complete all as specified and directed by Engineer-in-Charge. |
| 70 | Supply and fixing in replacement of recess mounting LED panel, 600 mm x 600 mm, with CRCA powder coated housing and SMD type LEDs, minimum system efficacy of 100 lm/W at system level, not chip level, rated life 50000 burning hours at L70 lumen maintenance, CCT up to 6500 K, CRI more than 80, power factor 0.95, operating voltage 140 V to 270 V, internal surge protection 2.5 kV, conforming to IS 10322 and IEC 60598, system wattage 31 W to 36 W, complete with electronic driver and all internal electrical connections complete all as specified and directed by Engineer-in-Charge. |
| 71 | Supply and fixing in replacement of recess mounting LED luminaire, 1 ft x 4 ft, with high transmittance diffuser, suitable for indoor spaces, with CRCA powder coated housing, minimum system efficacy of 100 lm/W at system level, not chip level, rated life 50000 burning hours at L70 lumen maintenance, CRI more than 80, power factor 0.95, operating voltage 140 V to 270 V, internal surge protection 2.5 kV, conforming to IS 10322 and IEC 60598, system wattage 31 W to 36 W, complete with electronic driver and all internal electrical connections complete all as specified and directed by Engineer-in-Charge. |
| 72 | Supply and fixing in repairs of LED spot light, 12 W, 3000 K warm white complete all as specified and directed by Engineer-in-Charge. |
| 73 | Supply and fixing in replacement of LED bulkhead fitting, 10 W, IP 65, with heat resistant plastic body and specially designed gasket complete all as specified and directed by Engineer-in-Charge. |
| 74 | Supply and fixing in replacement of building security light fitting, LED, 36 W, with day and night sensor, pressure die cast housing, IP 65, suitable for secondary roads/buildings, power consumption not more than 36 W and power factor not less than 0.90, including taking down the old unserviceable fitting complete all as specified and directed by Engineer-in-Charge. |
| 75 | Supply and fixing in replacement of building security light fitting, LED, 60 W, with day and night sensor, pressure die cast housing, IP 65, suitable for secondary roads/buildings, power consumption not more than 60 W and power factor not less than 0.90, including taking down the old unserviceable fitting complete all as specified and directed by Engineer-in-Charge. |
| 76 | Supply and fixing in replacement of LED flood light fitting, 120 W, energy saving, die cast aluminium housing, IP 65, with high power LEDs as light source, suitable for highlighting architectural facades, high mast and general purpose lighting, with all internal electrical connections complete all as specified and directed by Engineer-in-Charge. |
| 77 | Supply and fixing in replacement of post top LED landscape luminaire, clear type, 25 W, IP 65, energy saving, spun aluminium housing with symmetrical light distribution and high power LED light source, including necessary electrical connection and taking down the old unserviceable post top fitting complete all as specified and directed by Engineer-in-Charge. |
| 78 | Supply and fixing in replacement of post top LED landscape luminaire, spring type, 35 W, IP 65, energy saving, die cast aluminium housing with indirect symmetrical light distribution and high power COB LED light source, including necessary electrical connection and taking down the old unserviceable post top fitting complete all as specified and directed by Engineer-in-Charge. |
| 79 | Supply and fixing in replacement of LED bollard light, 10 W, 1000 mm high, IP 65, IK 10, with base plate, fixed in the ground with clamping arrangement, including all electrical connections and taking down the old unserviceable bollard fitting complete all as specified and directed by Engineer-in-Charge. |
| 80 | Supply and fixing of slim profile surface mounted LED downlight, round shape, 18 W, 2000 lumen, 4000 K, including all fixing arrangements complete all as specified and directed by Engineer-in-Charge. |
| 81 | Supply and fixing in replacement of decorative LED wall mounting luminaire with polycarbonate body, suitable for retrofit LED lamp up to 15 W, complete with 8 W LED lamp and lamp holder, including fixing arrangements, electrical connection and taking down the old rusted bracket fitting complete all as specified and directed by Engineer-in-Charge. Make: Philips COMET 30575/Wipro/Havells or equivalent approved by Engineer-in-Charge. |
| 82 | Supply and fixing in replacement of energy saving twin glow LED batten, 4 ft, 20 W, 2000 lumen, with up and down glow, yellow uplight relax mode and white downlight work mode, polycarbonate housing, 240 V, 50 Hz, IP 20, power factor 0.90, including taking down the old unserviceable fitting complete all as specified and directed by Engineer-in-Charge. |
| 83 | Material and labour in replacement for earthing complete with galvanised MS earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground, earth pit not less than 2.25 m deep below normal ground level, with top edge of the earth plate not less than 1.5 m below normal ground level, earth plate surrounded by alternate layers of charcoal and common salt, minimum 40 kg charcoal and 40 kg salt, completely covering the plate, connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel, including excavation, PCC 1:3:6 type C-1 using 20 mm graded stone aggregate in chamber, RCC cover 1:2:4 type B-1, 40 mm thick, reinforced with 8 mm dia bars, 3 Nos both ways, 15 mm dia light grade GI protection pipe, funnel with wire mesh, 20 mm dia medium grade watering pipe and lugs, all as shown in electrical Plate No. 3 of MES SSR Part I 2020, complete all as specified and directed by Engineer-in-Charge.Note 1: Main earth lead up to 7.5 m is deemed included in the unit rate; earth lead beyond 7.5 m shall be measured and paid separately.Note 2: The rate shall include earth work in excavation, returning, filling and removal, and disposal of surplus spoil to a distance not exceeding 50 m. |
| 84 | Material and labour of sheet metal enclosure for independent mounting of four pole MCB excluding, fixed with nuts, bolts and washers on wall/panel, with connection arrangement suitable for XLPE underground cables, including removing the old unserviceable switch fuse unit complete all as specified and directed by Engineer-in-Charge. |
| 85 | Supply and fixing in replacement of sheet metal enclosure for TPN MCCB distribution board, 8 way, 415 V, vertical type, double door, with 250 A bus bar, IP 43, IK 09, suitable for MCBs and MCCB up to 160 A as incomer, fixed on surface or in concealed position, including flexible conduit of size to suit the cables/wires at all exposed portions near the distribution board, and taking down the old unserviceable TPN distribution board enclosure complete all as specified and directed by Engineer-in-Charge. |
| 86 | Supply and fixing in replacement of sheet metal enclosure for TPN MCCB distribution board, 4 way, 415 V, vertical type, double door, with 250 A bus bar, IP 43, IK 09, suitable for MCBs and MCCB up to 160 A as incomer, fixed on surface or in concealed position, including flexible conduit of size to suit the cables/wires at all exposed portions near the distribution board, and taking down the old unserviceable TPN distribution board enclosure complete all as specified and directed by Engineer-in-Charge. |
| 87 | Supply and fixing in replacement of MCCB, 4 pole, 415 V, adjustable type, 160 A, breaking capacity 36 kA, Ics = 100 % Icu, conforming to IS/IEC 60947-2 complete all as specified and directed by Engineer-in-Charge. |
| 88 | Supply and fixing in replacement of MCCB, 4 pole, 415 V, 125 A, breaking capacity 16 kA, Ics = 100 % Icu, conforming to IS/IEC 60947-2 complete all as specified and directed by Engineer-in-Charge. |
| 89 | All as per item No. 88 above but 63 A complete all as specified and directed by Engineer-in-Charge. |
| 90 | Supply and fixing of electronic energy meter, single phase, 10-60 A, tamper proof, accuracy Class 1, with LED indication for earth leakage, polycarbonate enclosure, surge withstand up to 8 kV, anti-tamper features, electromagnetic compatible, 6 digit display complete all as specified and directed by Engineer-in-Charge. Make: L&T/HPL/Secure or equivalent approved by Engineer-in-Charge. |
| 91 | Material and labour for three phase, dual source, multifunction energy meter with AC sensing, accuracy Class 1.0, 3 x 240 V, 50 Hz, 10-60 A, with optical and Modbus RS 485 communication, backlit LCD display, measuring and displaying trivector energy, TOD, load survey, phase-wise voltage, current, power factor and frequency, and maximum demand, with anti-tamper features complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 19, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysDec 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender