Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #58602976

Tender For Repair & Maintenance Of Internal Electrical Infrastructure At N1, Nair, Kuldeep & N4 At Afs Kanpur.

Issued by Statutory Bodies & Commissions/Committees · Kanpur Nagar, Uttar Pradesh
Tender Value
50 Lakhs
Estimated cost
Bid Submission
08 Dec 2026
16 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kanpur Nagar → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair & Maintenance Of Internal Electrical Infrastructure At N1, Nair, Kuldeep & N4 At Afs Kanpur.

BOQ

Name of Work:- REPAIR & MAINTENANCE OF INTERNAL ELECTRICAL INFRASTRUCTURE AT N1, NAIR, KULDEEP & N4 AT AFS KANPUR.
Sl. No. Item Description
1Material and labour for taking down old unserviceable/deteriorated batten/PVC conduit point wiring from existing place, i.e. light, fan, socket or power points, complete with all unserviceable fittings such as switches, sockets, ceiling roses, pendants and holders, and making good all disturbed surfaces of wall, floor etc. in cement mortar 1:3 or plaster of Paris and finishing the new surface to match the existing surface with the same colour distemper, putty or white/colour wash complete all as specified and directed by Engineer-in-Charge.
2Material and labour for concealed point wiring for piano type switches and sockets on wall and surface wiring on ceiling/roof with necessary fixing arrangements, with PVC-FRLS insulated unsheathed multi-stranded copper conductor cable of size 1.5 sq mm, 1100 V grade, drawn in and including rigid non-metallic white/ivory PVC conduit, medium grade, ISI marked, conforming to IS 9537 Part 3, of 20 mm dia, with all conduit accessories and fittings such as junction boxes, bends, tees and elbows, including anodised MS sunken boxes made out of MS sheet of thickness not less than 1.5 mm with earth dolly and 3 mm thick ISI marked Bakelite laminated sheet for fixing of switches, sockets, fan regulators, wall mounted fittings, door bell and bulkhead, with MS screws and cup washers, including PVC-FRLS insulated unsheathed multi-stranded copper conductor cable of size 1.5 sq mm, 1100 V grade for continuous earthing, including cutting chases and making good the surface in cement mortar 1:3 and matching/finishing the new surface with plaster of Paris/putty and distemper/colour wash to the existing colour, for one light, fan or call bell point complete all as specified and directed by Engineer-in-Charge.
3All as per item No 2 above but for one socket point controlled by one switch on independent board complete all as specified and directed by Engineer-in-Charge.
4All as per item No 2 above but for one socket point controlled by one switch on same board complete all as specified and directed by Engineer-in-Charge.
5All as per item No 2 above but for power point wiring with 2.5 sq mm PVC-FRLS insulated unsheathed stranded copper conductor cable, 1100 V grade and 2.5 sq mm PVC-FRLS insulated unsheathed stranded copper conductor cable, 1100 V grade as continuous earth lead complete all as specified and directed by Engineer-in-Charge.
6Material and labour for surface point wiring on wall and ceiling/roof with necessary fixing arrangements, with PVC-FRLS insulated unsheathed multi-stranded copper conductor cable of size 1.5 sq mm, 1100 V grade, drawn in and including white/ivory PVC casing and capping 20 mm/25 mm with all accessories and fittings such as junction boxes, bends, tees and elbows, including PVC/polycarbonate gang box of appropriate size for fixing of switches, sockets, fan regulators, door bell and bulkhead with MS screws and cup washers, including PVC-FRLS insulated unsheathed multi-stranded copper conductor cable of size 1.5 sq mm, 1100 V grade for continuous earthing, for one light, fan or call bell point complete all as specified and directed by Engineer-in-Charge.
7All as per item No 6 above but for one socket point controlled by one switch on independent board complete all as specified and directed by Engineer-in-Charge.
8All as per item No 6 above but for one socket point controlled by one switch on same board complete all as specified and directed by Engineer-in-Charge.
9All as per item No 6 above but in casing and capping for power point wiring with 2.5 sq mm PVC-FRLS insulated unsheathed stranded copper conductor cable, 1100 V grade and 2.5 sq mm PVC-FRLS insulated unsheathed stranded copper conductor cable, 1100 V grade as continuous earth lead complete all as specified and directed by Engineer-in-Charge.
10Material and labour for concealed point wiring for modular switches and sockets on wall and surface wiring on ceiling/roof with necessary fixing arrangements, with PVC-FRLS insulated unsheathed multi-stranded copper conductor cable of size 1.5 sq mm, 1100 V grade, drawn in and including rigid non-metallic white/ivory PVC conduit, medium grade, ISI marked, conforming to IS 9537 Part 3, of 20 mm dia, with all conduit accessories and fittings such as junction boxes, bends, tees and elbows, including PVC-FRLS insulated unsheathed multi-stranded copper conductor cable of size 1.5 sq mm, 1100 V grade for continuous earthing, including cutting chases and making good the surface in cement mortar 1:3 and matching/finishing the new surface with plaster of Paris/putty and distemper/colour wash to the existing colour, for one light, fan, exhaust fan or call bell point complete all as specified and directed by Engineer-in-Charge.
11All as per item No 10 above but for one socket point controlled by one switch on independent board complete all as specified and directed by Engineer-in-Charge.
12All as per item No 10 above but for one socket point controlled by one switch on same board complete all as specified and directed by Engineer-in-Charge.
13All as per item No 10 above but for power point wiring with 2.5 sq mm PVC-FRLS insulated unsheathed stranded copper conductor cable, 1100 V grade and 2.5 sq mm PVC-FRLS insulated unsheathed stranded copper conductor cable, 1100 V grade as continuous earth lead complete all as specified and directed by Engineer-in-Charge.
14Material and labour for piano type switch, flush type, single pole, one way, 6 A, 240 V, white finish, conforming to IS 3854 complete all as specified and directed by Engineer-in-Charge.
15Material and labour for piano type switch, flush type, single pole, 16 A, 240 V, white finish, conforming to IS 3854 complete all as specified and directed by Engineer-in-Charge.
16Material and labour for socket outlet 3 pin, 6 A, flush type, white finish, conforming to IS 1293 complete all as specified and directed by Engineer-in-Charge.
17Supply and fixing of socket outlet 2 in 1, 3 pin, 6/16 A, flush type, universal, 240 V, white finish, conforming to IS 1293 complete all as specified and directed by Engineer-in-Charge.
18Supply and fixing of bell push, flush type, universal, 240 V, white finish complete all as specified and directed by Engineer-in-Charge.
19Supply and fixing of ceiling rose, surface type, Bakelite, 65 x 20 mm, three terminal complete all as specified and directed by Engineer-in-Charge.
20Supply and fixing of rotary regulator, 5 speed step type, 2 module, 120-230 V, white finish complete all as specified and directed by Engineer-in-Charge.
21Material and labour for modular switch, flush type, single pole, one way, 6 A, 240 V, white finish, conforming to IS 3854 complete all as specified and directed by Engineer-in-Charge.
22Material and labour for modular switch, flush type, single pole, 16 A, 240 V, white finish, conforming to IS 3854 complete all as specified and directed by Engineer-in-Charge.
23Material and labour for modular socket outlet 5 pin, 6 A, flush type, white finish, conforming to IS 1293 complete all as specified and directed by Engineer-in-Charge.
24Supply and fixing of modular socket outlet 2 in 1, 3 pin, 6/16 A, flush type, universal, 240 V, white finish, conforming to IS 1293 complete all as specified and directed by Engineer-in-Charge.
25Supply and fixing of modular bell push, flush type, universal, 240 V, white finish complete all as specified and directed by Engineer-in-Charge.
26Supply and fixing of modular rotary regulator, 5 speed step type, 2 module, 120-230 V, white finish complete all as specified and directed by Engineer-in-Charge.
27Supply and fixing of modular angle lamp holder, 6 A, 240 V complete all as specified and directed by Engineer-in-Charge.
28Supply and fixing in replacement of piano type switch, flush type, single pole, one way, 6 A, 240 V, white finish, conforming to IS 3854 complete all as specified and directed by Engineer-in-Charge.
29Supply and fixing in replacement of piano type switch, flush type, single pole, 16 A, 240 V, white finish, conforming to IS 3854 complete all as specified and directed by Engineer-in-Charge.
30Supply and fixing in replacement of socket outlet 3 pin, 6 A, flush type, white finish, conforming to IS 1293 complete all as specified and directed by Engineer-in-Charge.
31Supply and fixing in replacement of socket outlet 2 in 1, 3 pin, 6/16 A, flush type, universal, 240 V, white finish, conforming to IS 1293 complete all as specified and directed by Engineer-in-Charge.
32Supply and fixing in replacement of bell push, flush type, universal, 240 V, white finish complete all as specified and directed by Engineer-in-Charge.
33Supply and fixing in replacement of ceiling rose, surface type, Bakelite, 65 x 20 mm, three terminal complete all as specified and directed by Engineer-in-Charge.
34Supply and fixing in replacement of rotary regulator, 5 speed step type, 2 module, 120-230 V, white finish complete all as specified and directed by Engineer-in-Charge.
35Supply and fixing in replacement of piano type switch, flush type, two way, 6 A, 240 V, white finish, conforming to IS 3854 complete all as specified and directed by Engineer-in-Charge.
36Supply and fixing in replacement of electric bell, ding dong type complete all as specified and directed by Engineer-in-Charge.
37Supply and fixing in replacement of modular switch, flush type, single pole, one way, 6 A, 240 V, white finish, conforming to IS 3854 complete all as specified and directed by Engineer-in-Charge.
38Supply and fixing in replacement of modular switch, flush type, single pole, 16 A, 240 V, white finish, conforming to IS 3854 complete all as specified and directed by Engineer-in-Charge.
39Supply and fixing in replacement of modular socket outlet 5 pin, 6 A, flush type, white finish, conforming to IS 1293 complete all as specified and directed by Engineer-in-Charge.
40Supply and fixing in replacement of modular socket outlet 2 in 1, 3 pin, 6/16 A, flush type, universal, 240 V, white finish, conforming to IS 1293 complete all as specified and directed by Engineer-in-Charge.
41Supply and fixing in replacement of modular bell push, flush type, universal, 240 V, white finish complete all as specified and directed by Engineer-in-Charge.
42Supply and fixing in replacement of modular rotary regulator, 5 speed step type, 2 module, 120-230 V, white finish complete all as specified and directed by Engineer-in-Charge.
43Supply and fixing in replacement of modular angle lamp holder, 6 A, 240 V complete all as specified and directed by Engineer-in-Charge.
44Supply and fixing in replacement of modular metal flush box, 1 or 2 module, including taking down the old rusted box complete all as specified and directed by Engineer-in-Charge.
45Supply and fixing in replacement of modular metal flush box, 3 module, including taking down the old rusted box complete all as specified and directed by Engineer-in-Charge.
46Supply and fixing in replacement of modular metal flush box, 6 module, including taking down the old rusted box complete all as specified and directed by Engineer-in-Charge.
47Supply and fixing in replacement of modular metal flush box, 8 module, including taking down the old rusted box complete all as specified and directed by Engineer-in-Charge.
48Supply and fixing in replacement of modular metal flush box, 12 module, including taking down the old rusted box complete all as specified and directed by Engineer-in-Charge.
49Supply and fixing of modular white cover plate with frame, 1 module complete all as specified and directed by Engineer-in-Charge.
50Supply and fixing of modular white cover plate with frame, 3 module complete all as specified and directed by Engineer-in-Charge.
51Supply and fixing of modular white cover plate with frame, 6 module complete all as specified and directed by Engineer-in-Charge.
52Supply and fixing of modular white cover plate with frame, 8 module complete all as specified and directed by Engineer-in-Charge.
53Supply and fixing of modular white cover plate with frame, 12 module complete all as specified and directed by Engineer-in-Charge.
54Supply and fixing in replacement of anodised MS sunken box of required size, made out of MS sheet of thickness not less than 1.5 mm, with earth dolly and 3 mm thick ISI marked Bakelite laminated sheet for fixing of switches, sockets, fan regulators, wall mounted fittings, door bell and bulkhead, with MS screws and cup washers, including making good the surface in cement mortar 1:3 and matching/finishing the new surface with plaster of Paris/putty and distemper/colour wash to the existing colour complete all as specified and directed by Engineer-in-Charge.
55Supply and fixing in replacement of PVC/polycarbonate gang box, 3 way, of appropriate size for 6/16 A switch-socket arrangement, for fixing of switches, sockets and fan regulators, with MS screws and cup washers complete all as specified and directed by Engineer-in-Charge.
56Supply and fixing in replacement of PVC/polycarbonate gang box, 6 way, of appropriate size for 6/16 A switch-socket arrangement, for fixing of switches, sockets and fan regulators, with MS screws and cup washers complete all as specified and directed by Engineer-in-Charge.
57Supply and fixing in replacement of double door sheet metal enclosure for MCB distribution board, SPN, 8 way, 240 V, with 200 A rated bus bar, fixed on surface or in concealed position, including required sizes of flexible conduit at open surfaces near the distribution board for cables/wires complete all as specified and directed by Engineer-in-Charge.
58All as per item No 57 above but 4 way complete all as specified and directed by Engineer-in-Charge.
59Supply and fixing in replacement of double door sheet metal enclosure for MCB distribution board, TPN, 4 way, 415 V, horizontal type, with 200 A rated bus bar suitable for TPN MCB/4 pole isolator, fixed on surface or in concealed position, including required sizes of flexible conduit at open surfaces near the distribution board for cables/wires and taking down the old distribution board enclosure complete all as specified and directed by Engineer-in-Charge.
60Supply and fixing in replacement of MCB, SP, 240 V, 6 A to 32 A, 10 kA breaking capacity, C curve, conforming to IS/IEC 60898-1, connected with suitable lugs, fixed in repairs, including testing and commissioning complete all as specified and directed by Engineer-in-Charge.
61All as per item No 60 above but SP, 40 A to 63 A complete all as specified and directed by Engineer-in-Charge.
62All as per item No 60 above but SPN, 32 A complete all as specified and directed by Engineer-in-Charge.
63All as per item No 60 above but SPN, 40 A to 63 A complete all as specified and directed by Engineer-in-Charge.
64All as per item No 60 above but TP, 415 V, 40 A to 63 A complete all as specified and directed by Engineer-in-Charge.
65All as per item No 60 above but TPN, 415 V, 40 A to 63 A complete all as specified and directed by Engineer-in-Charge.
66Supply and fixing in replacement of sheet metal enclosure, 20 A, single pole and neutral, with two pin and earth plug and socket in metal clad board, fixed on surface or in concealed position complete all as specified and directed by Engineer-in-Charge.
67Supply and fixing in replacement of metal clad industrial socket, 2 pin and earth, with plug top, 20 A, 240 V, suitable for AC box complete all as specified and directed by Engineer-in-Charge.
68Supply and fixing in replacement of metal plug top, 20 A, 240 V, suitable for AC box complete all as specified and directed by Engineer-in-Charge.
69Supply and fixing in replacement of plug top, 16 A, 240 V complete all as specified and directed by Engineer-in-Charge.
70Supply and fixing of modular enclosure with 20 A single pole MCB and two pin and earth plug and socket, fixed on surface or in concealed position complete all as specified and directed by Engineer-in-Charge.
71Material and labour for sub-main wiring with two single core PVC-FRLS insulated unsheathed multi-stranded copper conductor cables of size 1.5 sq mm, 1100 V grade, drawn in and including PVC casing and capping of suitable size and all accessories, fixed on wall/floor surface, along with 1.5 sq mm PVC insulated unsheathed multi-stranded copper conductor cable, 1100 V grade as earth continuity conductor connected to the common earth dolly, including taking down the unserviceable old wiring complete all as specified and directed by Engineer-in-Charge.Note: Two single core cables, one run of earth copper conductor and one run of PVC casing and capping will be measured and paid as one unit length.Make: Polycab/Havells/Finolex or equivalent approved by Engineer-in-Charge.
72Material and labour for sub-main wiring with two single core PVC-FRLS insulated unsheathed multi-stranded copper conductor cables of size 2.5 sq mm, 1100 V grade, drawn in new/existing MS/PVC conduit, with 2.5 sq mm PVC-FRLS insulated unsheathed multi-stranded copper conductor as continuous earth wire, complete with all fixing accessories such as couplers, lock nuts, saddles and pipe hooks, including taking down the unserviceable old sub-main wiring complete all as specified and directed by Engineer-in-Charge.Note: Two single core cables and one run of earth copper conductor will be measured and paid as one unit length.Note: PVC conduit, where required, shall be measured and paid separately under item No 78.Make: Polycab/Havells/Finolex or equivalent approved by Engineer-in-Charge.
73Material and labour for sub-main wiring with two single core PVC-FRLS insulated unsheathed multi-stranded copper conductor cables of size 2.5 sq mm, 1100 V grade, drawn in and including PVC casing and capping of suitable size and all accessories, fixed on wall/floor surface, along with 2.5 sq mm PVC insulated unsheathed multi-stranded copper conductor cable, 1100 V grade as earth continuity conductor connected to the common earth dolly, including taking down the unserviceable old wiring complete all as specified and directed by Engineer-in-Charge.Note: Two single core cables, one run of earth copper conductor and one run of PVC casing and capping will be measured and paid as one unit length.Make: Polycab/Havells/Finolex or equivalent approved by Engineer-in-Charge.
74Material and labour for sub-main wiring with two single core PVC-FRLS insulated unsheathed multi-stranded copper conductor cables of size 4 sq mm, 1100 V grade, drawn in new/existing MS/PVC conduit, with 4 sq mm PVC-FRLS insulated unsheathed multi-stranded copper conductor as continuous earth wire, complete with all fixing accessories such as couplers, lock nuts, saddles and pipe hooks, including taking down the unserviceable old sub-main wiring complete all as specified and directed by Engineer-in-Charge.Note: Two single core cables and one run of earth copper conductor will be measured and paid as one unit length.Note: PVC conduit, where required, shall be measured and paid separately under item No 78.Make: Polycab/Havells/Finolex or equivalent approved by Engineer-in-Charge.
75Material and labour for sub-main wiring with two single core PVC-FRLS insulated unsheathed multi-stranded copper conductor cables of size 4 sq mm, 1100 V grade, drawn in and including PVC casing and capping of suitable size and all accessories, fixed on wall/floor surface, along with 4 sq mm PVC insulated unsheathed multi-stranded copper conductor cable, 1100 V grade as earth continuity conductor connected to the common earth dolly, including taking down the unserviceable old wiring complete all as specified and directed by Engineer-in-Charge.Note: Two single core cables, one run of earth copper conductor and one run of PVC casing and capping will be measured and paid as one unit length.Make: Polycab/Havells/Finolex or equivalent approved by Engineer-in-Charge.
76Material and labour for sub-main wiring with two single core PVC-FRLS insulated unsheathed multi-stranded copper conductor cables of size 6 sq mm, 1100 V grade, drawn in new/existing MS/PVC conduit, with 6 sq mm PVC-FRLS insulated unsheathed multi-stranded copper conductor as continuous earth wire, complete with all fixing accessories such as couplers, lock nuts, saddles and pipe hooks, including taking down the unserviceable old sub-main wiring complete all as specified and directed by Engineer-in-Charge.Note: Two single core cables and one run of earth copper conductor will be measured and paid as one unit length.Note: PVC conduit, where required, shall be measured and paid separately under item No 79.Make: Polycab/Havells/Finolex or equivalent approved by Engineer-in-Charge.
77Material and labour for sub-main wiring with two single core PVC-FRLS insulated unsheathed multi-stranded copper conductor cables of size 6 sq mm, 1100 V grade, drawn in and including PVC casing and capping of suitable size and all accessories, fixed on wall/floor surface, along with 6 sq mm PVC insulated unsheathed multi-stranded copper conductor cable, 1100 V grade as earth continuity conductor connected to the common earth dolly, including taking down the unserviceable old wiring complete all as specified and directed by Engineer-in-Charge.Note: Two single core cables, one run of earth copper conductor and one run of PVC casing and capping will be measured and paid as one unit length.Make: Polycab/Havells/Finolex or equivalent approved by Engineer-in-Charge.
78Supply and fixing in replacement of rigid non-metallic white/ivory PVC conduit, medium grade, ISI marked, conforming to IS 9537 Part 3, of size 20 mm dia, in concealed position, including all fittings such as tees, bends, reducers, elbows, bell mouths and tube ends and all fixing accessories such as couplers, lock nuts, saddles and pipe hooks, including cutting chases and making good the disturbed surfaces to match the existing colour of wall/floor and taking down the old broken conduit complete all as specified and directed by Engineer-in-Charge.
79All as per item No 78 above but 25 mm dia complete all as specified and directed by Engineer-in-Charge.
80Supply and fixing in replacement of white/ivory PVC casing and capping, medium grade, ISI marked, 20 mm wide, including all fittings such as tees, bends, elbows and end caps and all fixing accessories, including taking down the old broken casing and capping complete all as specified and directed by Engineer-in-Charge.
81Material and labour for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, sills, sunshades, shelves, lintels etc. and cutting chases for concealed water tubing or concealed wiring and making good, cutting not exceeding 10 cm girth complete all as specified and directed by Engineer-in-Charge.
82Material and labour in repairs for PVC insulated sheathed weatherproof twin core service cable with solid aluminium conductor of size 6 sq mm, including taking down the unserviceable old cable complete all as specified and directed by Engineer-in-Charge.
83All as per item No 82 above but cable size 4 sq mm complete all as specified and directed by Engineer-in-Charge.
84All as per item No 82 above but cable size 10 sq mm complete all as specified and directed by Engineer-in-Charge.
85Material and labour for 3 core PVC insulated, PVC sheathed flexible copper conductor cable of size 2.5 sq mm, 1100 V grade, in replacement of the old unserviceable cable, for connection of light fittings and appliances, including connections at both ends and taking down the old cable complete all as specified and directed by Engineer-in-Charge.
86Material and labour for 3 core PVC insulated, PVC sheathed flexible copper conductor cable of size 1.5 sq mm, 1100 V grade, in replacement of the old unserviceable cable, for connection of light fittings and appliances, including connections at both ends and taking down the old cable complete all as specified and directed by Engineer-in-Charge.
87Material and labour for 3 core PVC insulated, PVC sheathed flexible copper conductor cable of size 1.0 sq mm, 1100 V grade, in replacement of the old unserviceable cable, for connection of light fittings and appliances, including connections at both ends and taking down the old cable complete all as specified and directed by Engineer-in-Charge.
88Material and labour for XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 V grade, conforming to IS 7098 Part 1, of size 10 sq mm, 2 core, in replacement of the old unserviceable cable, laid in trenches/panel or drawn through pipe, including connecting with suitable lugs, nuts and bolts, testing and taking down the old cable complete all as specified and directed by Engineer-in-Charge.
89Material and labour for XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 V grade, conforming to IS 7098 Part 1, of size 4 sq mm, 2 core, in replacement of the old unserviceable cable, laid in trenches/panel or drawn through pipe, including connecting with suitable lugs, nuts and bolts, testing and taking down the old cable complete all as specified and directed by Engineer-in-Charge.
90Material and labour for XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 V grade, conforming to IS 7098 Part 1, of size 10 sq mm, 4 core, in replacement of the old unserviceable cable, laid in trenches/panel or drawn through pipe, including connecting with suitable lugs, nuts and bolts, testing and taking down the old cable complete all as specified and directed by Engineer-in-Charge.
91Supply and fixing in replacement of energy saving LED light fitting 40 W, 240 V, single tube mounting, including LED tube/LED blocks of 40 W with lumen output not less than 100 lm/W, life 50,000 burning hours and power factor 0.95, complete with electronic driver, LED printed circuit board, end covers, connector box and accessories, prewired, including fixing arrangements and electrical connection with three core copper cable from ceiling rose to the fitting, including removing the unserviceable tube light fitting complete all as specified and directed by Engineer-in-Charge.
92Supply and fixing in replacement of energy saving LED batten 4 ft, 22 W, with nominal system lumen output not less than 2400 lumens and minimum system efficacy of 110 lm/W, with fixing arrangements and electrical connection with three core copper cable from ceiling rose to the fitting, including removing the unserviceable fitting. The luminaire shall have a rated system life of 40,000 burning hours at L70, colour temperature 6500 K, CRI more than 80, IP 20, THD less than 10 % and power factor more than 0.95, with extruded aluminium housing and polycarbonate glossy diffuser complete all as specified and directed by Engineer-in-Charge.
93Supply and fixing in replacement of energy saving LED smart batten fitting 10 W, 240 V, box type, complete with accessories, including fixing arrangements and electrical connection with three core copper cable from ceiling rose to the fitting, including removing the unserviceable bracket fitting complete all as specified and directed by Engineer-in-Charge.
94Supply and fixing in replacement of recess mounted LED panel 600 x 600 mm, made of CRCA, powder coated, with SMD type LEDs, minimum efficacy 100 lm/W at system level, not chip level, life 50,000 burning hours at L70 lumen maintenance, CCT up to 6500 K, CRI more than 80, power factor 0.95, operating voltage 140 V to 270 V, internal surge protection 2.5 kV, conforming to IS 10322 and IEC 60598, system wattage 31 W to 36 W, complete with electronic driver and all internal electrical connections complete all as specified and directed by Engineer-in-Charge.
95Supply and fixing in replacement of recess mounted LED luminaire 1 ft x 4 ft with high transmissive diffuser suitable for indoor spaces, made of CRCA, powder coated, minimum efficacy 100 lm/W at system level, not chip level, life 50,000 burning hours at L70 lumen maintenance, CRI more than 80, power factor 0.95, operating voltage 140 V to 270 V, internal surge protection 2.5 kV, conforming to IS 10322 and IEC 60598, system wattage 31 W to 36 W, complete with electronic driver and all internal electrical connections complete all as specified and directed by Engineer-in-Charge.
96Supply and fixing in replacement of LED bulkhead fitting 10 W, IP 65, with heat resistant plastic body and specially designed gasket complete all as specified and directed by Engineer-in-Charge.
97Supply and fixing in replacement of LED building security light fitting 36 W with pressure die cast housing, IP 65, suitable for secondary roads/buildings, power consumption not more than 35 W and power factor not less than 0.90, including taking down the old fitting complete all as specified and directed by Engineer-in-Charge.
98Supply and fixing in replacement of LED building security light fitting 60 W with pressure die cast housing, IP 65, suitable for secondary roads/buildings, power consumption not more than 60 W and power factor not less than 0.90, including taking down the old fitting complete all as specified and directed by Engineer-in-Charge.
99Supply and fixing in replacement of LED flood light fitting 120 W, energy saving, long life, die cast aluminium, IP 65, with high power LEDs as light source, suitable for highlighting architectural facades, high mast and general purpose lighting, with all internal electrical connections complete all as specified and directed by Engineer-in-Charge.
100Supply and fixing in replacement of new generation LED post top landscape luminaire, clear, energy saving, long life, spun aluminium, IP 65, with symmetrical light distribution and high power LED as light source of capacity 35 W, including necessary electrical connection and taking down the old fitting complete all as specified and directed by Engineer-in-Charge.Make: Philips/Havells/Wipro or equivalent approved by Engineer-in-Charge.
101Supply and fixing in replacement of new generation LED post top spring landscape luminaire, energy saving, long life, die cast aluminium, IP 65, with indirect symmetrical light distribution and high power COB LED as light source of capacity 35 W, including necessary electrical connection and taking down the old fitting complete all as specified and directed by Engineer-in-Charge.Make: Philips/Havells/Wipro or equivalent approved by Engineer-in-Charge.
102Supply and fixing in replacement of LED bollard light 10 W, 1000 mm high, aesthetic design, IP 65, IK 10, with base plate, fixed on foundation bolts, including all necessary electrical connections and taking down the old bollard complete all as specified and directed by Engineer-in-Charge.
103Supply and fixing of slim profile surface mounted LED downlight, round shape, 2000 lumens, 4000 K, including all fixing arrangements complete all as specified and directed by Engineer-in-Charge.
104Supply and fixing of LED bulb 8 W, conforming to IS 16102 complete all as specified and directed by Engineer-in-Charge.
105Supply and fixing of LED bulb 14 W, conforming to IS 16102 complete all as specified and directed by Engineer-in-Charge.
106Supply and fixing of LED inverter bulb 14 W with battery backup of 4 hours complete all as specified and directed by Engineer-in-Charge.
107Supply and fixing in replacement of decorative LED wall mounted luminaire, retrofit, with 8 W LED bulb and lamp holder, made of polycarbonate, including fixing arrangements and electrical connections and taking down the old rusted bracket fitting complete all as specified and directed by Engineer-in-Charge.Make: Philips/Havells/Wipro or equivalent approved by Engineer-in-Charge.
108Supply and fixing in replacement of energy saving LED batten 4 ft, 20 W, 2000 lumens, twin glow, with yellow uplight relax mode and white downlight work mode, aesthetic design, polycarbonate housing, 240 V, 50 Hz, IP 20 and power factor 0.90, including taking down the old fitting complete all as specified and directed by Engineer-in-Charge.Make: Philips/Havells/Wipro or equivalent approved by Engineer-in-Charge.
109Supply and fixing in replacement of LED high bay luminaire 150 W, 240 V, complete with electronic driver and reflector of suitable size, hanging/fixing arrangements and connecting with three core copper cable 2.5 sq mm, including taking down the old worn out high bay luminaire complete all as specified and directed by Engineer-in-Charge.
110Supply and fixing in replacement of LED building security light 90 W with aluminium pressure die cast housing and glass cover, IP 66, including taking down the old unserviceable fitting complete all as specified and directed by Engineer-in-Charge.
111Material and labour for earthing in replacement, complete with galvanised MS earth plate electrode 600 x 600 x 6 mm thick buried directly in ground, earth pit not less than 2.25 m deep below normal ground level, with top edge of the earth plate not less than 1.5 m below normal ground level, earth plate surrounded by charcoal and common salt in alternate layers, minimum 40 kg charcoal and 40 kg salt, completely covering the GI plate, connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel, including excavation, PCC 1:3:6 type C-1 using 20 mm graded stone aggregate in chamber with RCC cover 1:2:4 type B-1, 40 mm thick, reinforced with 8 mm dia bars, 3 Nos both ways, 15 mm dia light grade GI protection pipe, funnel with wire mesh, watering pipe of 20 mm dia medium grade, lugs etc. all as shown in electrical plate No. 3 of MES SSR Part I 2020, conforming to IS 3043 complete all as specified and directed by Engineer-in-Charge.Note: Main earth lead up to 7.5 m shall be deemed to be included in the unit rate. Earth lead beyond 7.5 m shall be measured and paid separately.Note: The rate quoted shall be inclusive of earth work, i.e. excavation, returning, filling and removal, including disposal of spoil to a distance not exceeding 50 m.
112Receiving complaints from the concerned In-charge of the Internal Section, Power House, lodged by the occupants on internal electrification, and attending to them: taking down tube light/CFL fittings, bracket fittings, flameproof tube light fittings and flameproof bulkhead fittings of any wattage from roof/wall and PVC cables for light/fan/bell/light or power socket points; repairs by removing connections from the system and removing faults in wires, battens, conduits, sunk boxes, junction boxes, main switches, MCBs/distribution boards, utility light fittings, lamp holders, AC, ceiling and exhaust fans and other connected fixtures of the internal electrification, including providing petty stores such as wires of appropriate size and conductor matching the existing, up to a length of 1 m, insulation tape, screws and nuts as required to rectify the fault with regard to the complaint lodged; dismantling at site, testing of unserviceable and serviceable items and replacement of the same, tightening of connections, replacement of unserviceable connecting wire, ensuring that the earth wire is properly connected to the metallic parts of the fitting, cleaning the fittings externally and internally after ensuring their serviceability, and refixing the fittings and fixtures at the same or directed place, including testing complete all as specified and directed by Engineer-in-Charge.Note: Tube light fittings of any type, switches, sockets, bell pushes, regulators and chokes of any type required for replacement will be paid under the relevant supply and fixing in replacement items of this schedule.
113Material and labour for bracket made of GI pipe 25 mm dia, medium grade, 1.2 m long, bent to shape, with welded MS flat 25 x 4 mm for mounting of fitting and MS flat iron clamps of 25 x 4 mm, with nuts and bolts, including taking down the old unserviceable bracket of any size complete all as specified and directed by Engineer-in-Charge.
114Material and labour for sheet metal enclosure for independent mounting of four pole MCB, fixed with suitable nuts, bolts and washers on wall/panel, with suitable connection arrangements for XLPE underground cables with MCBs, including removing the unserviceable switch fuse unit complete all as specified and directed by Engineer-in-Charge.
115Supply and fixing in replacement of sheet metal enclosure for TPN MCCB distribution board, 8 way, 415 V, vertical type, double door, with 250 A bus bar, IP 43, IK 09, for MCBs and MCCB up to 160 A as incomer, fixed on surface or in concealed position, including required sizes of flexible conduit at open surfaces near the distribution board for cables/wires and taking down the old distribution board enclosure complete all as specified and directed by Engineer-in-Charge.
116Supply and fixing in replacement of sheet metal enclosure for TPN MCCB distribution board, 4 way, 415 V, vertical type, double door, with 250 A bus bar, IP 43, IK 09, for MCBs and MCCB up to 160 A as incomer, fixed on surface or in concealed position, including required sizes of flexible conduit at open surfaces near the distribution board for cables/wires and taking down the old distribution board enclosure complete all as specified and directed by Engineer-in-Charge.
117Supply and fixing in replacement of MCCB 160 A, 4 pole, 415 V, adjustable type, 36 kA, Ics = 100 % Icu, conforming to IS/IEC 60947-2, including connections, testing and taking down the old unserviceable MCCB complete all as specified and directed by Engineer-in-Charge.
118Supply and fixing in replacement of MCCB 125 A, 4 pole, 415 V, 16 kA, Ics = 100 % Icu, conforming to IS/IEC 60947-2, including connections, testing and taking down the old unserviceable MCCB complete all as specified and directed by Engineer-in-Charge.
119Supply and fixing in replacement of MCCB 63 A, 4 pole, 415 V, 16 kA, Ics = 100 % Icu, conforming to IS/IEC 60947-2, including connections, testing and taking down the old unserviceable MCCB complete all as specified and directed by Engineer-in-Charge.
120Supply and fixing of electronic energy meter, single phase, 10-60 A, tamper proof, Class 1 accuracy, conforming to IS 13779, with LED indication for earth leakage, polycarbonate enclosure, surge withstand up to 8 kV, anti-tamper features, electromagnetic compatible and 6 digit display complete all as specified and directed by Engineer-in-Charge.Make: L&T/HPL/Secure or equivalent approved by Engineer-in-Charge.
121Material and labour for AC three phase, dual source, multifunction energy meter with AC sensing, accuracy Class 1.0, 3 x 240 V, 50 Hz, 10-60 A, with optical and Modbus RS 485 communication and backlit LCD display, measuring and displaying trivector energy, TOD, load survey, phase-wise voltage, current, power factor and frequency and maximum demand, with anti-tamper feature complete all as specified and directed by Engineer-in-Charge.
122Supply and fixing in replacement of BLDC ceiling fan 1200 mm sweep, copper wound, energy efficient, BEE 5 star rated, complete with down rod, canopy and blades, suitable for 240 V, 50 Hz supply complete all as specified and directed by Engineer-in-Charge.
123Supply and fixing in replacement of BLDC ceiling fan 1400 mm sweep, copper wound, energy efficient, BEE 5 star rated, complete with down rod, canopy and blades, suitable for 240 V, 50 Hz supply complete all as specified and directed by Engineer-in-Charge.
124Supply and fixing in replacement of exhaust fan 300 mm sweep, copper wound, 1400 RPM, heavy duty metallic body, complete with brackets, frame, blades and louvres of suitable size, suitable for 240 V, 50 Hz supply complete all as specified and directed by Engineer-in-Charge.
125All as per item No 124 above but 380 mm sweep complete all as specified and directed by Engineer-in-Charge.
126All as per item No 124 above but 450 mm sweep complete all as specified and directed by Engineer-in-Charge.Note: Old ceiling and exhaust fans replaced under item Nos 122, 123, 124, 125 and 126 shall be deposited in the MES store.
127Supply and fixing in replacement of cabin fan/wall fan 450 mm sweep, copper wound, 1400 RPM, with oscillating function, heavy duty metallic body, complete with brackets, frame, blades and louvres of suitable size, suitable for 240 V, 50 Hz supply complete all as specified and directed by Engineer-in-Charge.
128Supply and fixing in replacement of ventilating/fresh air fan 250 mm, suitable for 240 V, 50 Hz supply complete all as specified and directed by Engineer-in-Charge.
129Supply in replacement of pedestal fan 450 mm sweep, suitable for 240 V, 50 Hz supply complete all as specified and directed by Engineer-in-Charge.Note: Old fans replaced under item Nos 127, 128 and 129 shall be deposited in the MES store yard. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58602976
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 50 Lakhs
LAST DATE 08-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair & Maintenance Of Internal Electrical Infrastructure At N1, Nair, Kuldeep & N4 At Afs Kanpur.
Basic Detail
Tender No 8887/E8
Bidding Type Tender
Location
City Kanpur Nagar
State Uttar Pradesh
Key Dates
Publish Date 19 Nov 2026
Submission Date 08 Dec 2026
Open Date 15 Dec 2026
Finance
Tender Value 50 Lakhs
Tender Fee 500
EMD 1 Lakhs
Exemption Available
Document List
5b47d37a-cd6e-492f-9b7e-a4cdc980fa10.html
BOQ_896306.xls
Schedule_of_Credit_8887.pdf
Tendernotice_1.pdf
Tender_Acceptance_Letter.pdf
Tender_Document_8887.pdf
Workdetails.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 19, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Dec 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

5b47d37a-cd6e-492f-9b7e-a4cdc980fa10.html

xls

BOQ_896306.xls

pdf

Schedule_of_Credit_8887.pdf

pdf

Tendernotice_1.pdf

pdf

Tender_Acceptance_Letter.pdf

pdf

Tender_Document_8887.pdf

pdf

Workdetails.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender