Tender For Repair/ Maintenance To Pump Sets, Lt Panels, Submersible Pumps Sets, Starters, Cables And Connected Accessories At Nofra And Wnc (O) Mess, Robert Road Complex Area Under Ge (Nw) Navy Nagar, Colaba, Mumbai
Tender Value
49 Lakhs
Estimated cost
Bid Submission
08 Dec 2026
16 days left
EMD
98000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Maintenance To Pump Sets, Lt Panels, Submersible Pumps Sets, Starters, Cables And Connected Accessories At Nofra And Wnc (O) Mess, Robert Road Complex Area Under Ge (Nw) Navy Nagar, Colaba, Mumbai
BOQ
| Sl. No. | Item Description |
| 1 | Supply and laying in replacement of copper unamoured power cable of size 16 sqmm single core from motor starter panel to motor in and including HDPE pipe in ground including copper lugs, nut bolts and washers as reqd at site complete all as specified and directed. |
| 2 | Supply and laying in replacement of copper unamoured power cable of size 25 sqmm single core from motor starter panel to motor in and including HDPE pipe in ground including copper lugs, nut bolts and washers as reqd at site complete all as specified and directed. |
| 3 | Supply and laying in replacement of copper unamoured power cable of size 35 sqmm single core from motor starter panel to motor in and including HDPE pipe in ground including copper lugs, nut bolts and washers as reqd at site complete all as specified and directed. |
| 4 | Supply and laying in replacement of copper unamoured power cable of size 70 sqmm single core from motor starter panel to motor in and including HDPE pipe in ground including copper lugs, nut bolts and washers as reqd at site complete all as specified and directed. |
| 5 | Supply and fixing in repair MCCB 4 Pole with thermal adjustment of 0.8 to 1 In and magnetic adjustable 5 to 10 In and Ics=100% of Icu and replacing burnout copper spreaders of suitable size including nuts and bolts and fixing to existing panel including necessary alternation to existing busbar and panel all as specified and directed by Enginner-in-charge |
| 6 | MCCB of 630 A ,Breaking capacity 50 KA,4P |
| 7 | MCCB of 400 A ,Breaking capacity 36 KA,4P |
| 8 | MCCB of 200A ,Breaking capacity 36KA,4P |
| 9 | MCCB of 160A ,Breaking capacity 36KA,4P |
| 10 | MCCB of 125 A,Breaking capacity 16KA,4P |
| 11 | MCCB of 63 A,Breaking capacity 16KA,4P |
| 12 | Supply, install, test and commissioning in replacement of LT Panel board from CPRI approved panel manufacturer made out of of 3.15mm CRCA sheet cubical totally enclosed with frame made out of 50mm x 50mm x 6mm angle iron door front and back openable with locking arrangement indoor type vermin and weather proof floor mounting type, suitable for 3 phase 4 wire,50 HZ , 415 Volt AC supply with 600A capacity copper bus bar (4 Nos) All MCCB shall be connected with suitable size of copper strip from main bus & with terminate point and complete wiring of panel board with suitable size PVC insulated multistranded copper conductor including lugs/thimbles etc with suitable Cable alley for provn of cable entries at bottom with cable glands including the following :-(a) MCCB 4 pole, 415V,400Amps 50 KA - 01 No (incoming) thermo magnetic adjustable release type,ICS=ICU=100% (b) MCCB 3 pole,415V,250mps 50 KA - 03 Nos (outgoing) thermo magnetic adjustable release type,ICS=ICU=100% (c) Automatic star/Delta starters panel with all accessories mounting suitable for 75 HP-03 Nos. (d) Phase indicating lamps(RYB)-04 set(e) Digital panel meter for Amp,Volt,KWH, power factor and other parameter flush mounting of size 96X96mm-04 set. (f) Suitable CTs for main and for 03 starter panels. |
| 13 | Supply, install, test and commissioning in replacement of LT Panel board from CPRI approved panel manufacturer made out of of 3.15 mm CRCA sheet cubical totally enclosed with frame made out of 50mm x 50mm x 6mm angle iron door front and back openable with locking arrangement indoor type vermin and weather proof floor mounting type, suitable for 3 phase 4 wire,50 HZ , 415 Volt AC supply with 800A capacity copper bus bar (4 Nos) All MCCB shall be connected with suitable size of copper strip from main bus & with terminate point and complete wiring of panel board with suitable size PVC insulated multistranded copper conductor including lugs/thimbles etc suitable Cable alley with for provn of cable entries at bottom with cable glands including the following :-(a) MCCB 4 pole, 415V,630Amps 50 KA - 02 Nos (incoming) thermo magnetic adjustable release type,ICS=ICU=100% (b) On load change over switch 630 Amps, 4 pole, 415 volts-01 No. (c) MCCB 4 pole, 415V,400Amps 50 KA - 03 Nos (Out going) thermo magnetic adjustable release type,ICS=ICU=100% (d) Phase indicating lamps(RYB)-04 set(e) Digital panel meter for Amp,Volt,KWH, power factor and other parameter flush mounting of size 96X96mm-01 set.Note for item No. 06 to 07 : including all necessary accessories for operation of panel and control wiring with furrule indicator, current transformers ,push buttons ,indication lamps for RYB phases,ON and OFFswitches, digital voltmeter,ammemter, cable alley ,terminal block,selector swithes complete as directed by Engr-in-ChargeNote :- The panel board shall be fabricated from CPRI approved firm and panel drawings shall be submitted by the contractor for approval before placing the order. |
| 14 | Supply and fixing in replacement LED street light luminaire 60 watt made up of pressure die cast aluminium housing with toughened glass and high power LED sand secondary lenses with IP-66 protection, Efficeincy : 110 LM/W, 10 KV SPD included complete including making connections with copper wire 1.0 sqmm complete all as specified and directed. |
| 15 | M&L for replacement of Earthing completely using Copper Bonded Rod of diameter more than 15mm and length of 10 feet below ground level .The material shall be low carbon high tensile copper bonded rods with 99.9 % of copper on the surface. pit shall be filled with highly conductive and eco friendly ground enhancing compound as per IEC 62561- 7 shall be not less than 30Kg per pit & PCC 1:3:6 Earth Pit chamber of size 310mm×300×170mm(W×L×H) with Cast iron cover complete all as specified and directed |
| 16 | S&F in repair Earth continuity conductor or main earthing lead of size 25× 4mm GI fixed to wall using insulated earth strip at every 2 feet ditsance earthing strip should be fixed from 6th to ground floor and necessary termination with nuts and bolts complete all as specified and directed |
| 17 | Demolition of Exisiting concrete supporting block of pumps and motor excedding 15cm of thickness above and below ground level all specfied and directed by Engineer-in-charge |
| 18 | M&L cement concrete 1:2:4, type B-2 (using 40 mm graded stone aggregate) as in support of Base frame with MS bolts placed in concrete and hardstanding finishing even and fair without using extra cement all as specified. Note: Location of bolts and size of bolts should macht the previous one |
| 19 | Supply and fixing in replacement butterfly valve of 150 mm dia PN 1.6 complete all as specified and directed |
| 20 | M& L for Disconnecting centrifugal pump from motor, suction and delivery pipe line of any Make, model and taking down packing for removing and insertion of new shaft sleeves or remove Bearing using bearing puller gear and fix new all two bearings and greasing all parts, coupling pump to motor and check for proper shaft alignments such that no vibration produce during opertion of following capacity pumps, complete all as specfied and as directed by Engineer-in-charge. |
| 21 | Bearings suitable for Pump coupled with 175 HP motor |
| 22 | Bearings suitable for Pump coupled with 100 HP motor |
| 23 | Bearings suitable for Pump coupled with 75 HP motor |
| 24 | Bearings suitable for Pump coupled with 60 HP motor |
| 25 | Bearings suitable for Pump coupled with 40/50 HP motor |
| 26 | Bearings suitable for Pump coupled with 30 HP motor |
| 27 | Bearings suitable for Pump coupled with 25 HP motor |
| 28 | Bearings suitable for Pump coupled with 15 HP motor |
| 29 | Supply and fixing of self lubricated asbestoes non metallic and non graphite gland packing white colour of sizes 8 to 12 mm complete all as specified and directed Make : Champion or equivalent |
| 30 | M&L for replacement of MS jaw coupling type-L with spider made of synthetic rubber or gear coupled type of suitable for 175 HP motor |
| 31 | M&L for replacement of MS jaw coupling type-L with spider made of synthetic rubber or gear coupled type of suitable for 100 HP motor |
| 32 | M&L for replacement of MS jaw coupling type-L with spider made of synthetic rubber or gear coupled type of suitable for 75 HP motor |
| 33 | M&L for replacement of MS jaw coupling type-L with spider made of synthetic rubber or gear coupled type of suitable for 60 HP motor |
| 34 | M&L for replacement of MS jaw coupling type-L with spider made of synthetic rubber or gear coupled type of suitable for 50/40 HP motor |
| 35 | M&L for replacement of MS jaw coupling type-L with spider made of synthetic rubber or gear coupled type of suitable for 30 HP motor |
| 36 | M&L for replacement of MS jaw coupling type-L with spider made of synthetic rubber or gear coupled type of suitable for 25 HP motor |
| 37 | M&L for replacement of MS jaw coupling type-L with spider made of synthetic rubber or gear coupled type of suitable for 15 HP motor |
| 38 | Supply and Fixing in repair rolling shutter with ball bearing, thickness of laths 1.25mm as specified including top cover, anchoring rod, hasp and staple, gear box,etc gear operated type with chain wheel and hand chain and one shop coat of primer erected in position complete all as specified and directed by Engineer-in-Charge. |
| 39 | S&F in repair AC-3 type contactor with control voltage of 415V AC, 50 Hz with integrated auxillary or Add on block contacts with 1 or 2 NO and NC including connection of control wiring to contactor and testing of starter after repairing . |
| 40 | Contactor rating of between 140A to 185A |
| 41 | Contactor rating of between 110A to 140A |
| 42 | Contactor rating of between 80A to 110A |
| 43 | Contactor rating of between 45A to 80A |
| 44 | Contactor rating of between 32A to 45A |
| 45 | Contactor rating of between 18A to 32A Please Enable Macros to View BoQ information |
| 46 | Contactor rating of between 18A to 32A Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysDec 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender