Tender For Repair / Maintenance To Pump Sets, Lt Panel Boards, Starters At Ao Ph, Mithun Ph, R1, R2, R3, R4, R9, R12/13, R28 Pump House Area Including Glow Sign Boards, Gate Lights And Connected Items Under Ge (Nw) Navy Nagar, Colaba, Mumbai
Tender Overview
Project Description
Tender for Repair / Maintenance To Pump Sets, Lt Panel Boards, Starters At Ao Ph, Mithun Ph, R1, R2, R3, R4, R9, R12/13, R28 Pump House Area Including Glow Sign Boards, Gate Lights And Connected Items Under Ge (Nw) Navy Nagar, Colaba, Mumbai
BOQ
| Sl. No. | Item Description |
| 1 | M& L for Disconnecting pump from motor of any Make, model and remove Bearing using bearing puller gear and fix new all two bearings at DE/NDE mathcing with existing bearing model and number for pump including necessary greasing, check for proper shaft alignments, vibration pads, such that no vibratiobn produce during opertion of following capacity Motors. |
| 2 | Bearings suitable for Pump coupled with 200 HP motor |
| 3 | Bearings suitable for Pump coupled with 150 HP motor |
| 4 | Bearings suitable for Pump coupled with 120 HP motor |
| 5 | Bearings suitable for Pump coupled with 75 HP motor |
| 6 | Bearings suitable for Pump coupled with 60 HP motor |
| 7 | Bearings suitable for Pump coupled with 40/50 HP motor |
| 8 | Bearings suitable for Pump coupled with 30 HP motor |
| 9 | Bearings suitable for Pump coupled with 20/25 HP motor |
| 10 | Bearings suitable for Pump coupled with 15 HP motor |
| 11 | Bearings suitable for Pump coupled with 10/7.5 HP motor |
| 12 | M& L for Disconnecting motor from pump of any Make, model and remove Bearing using bearing puller gear and fix new all two bearings at DE/NDE mathcing with existing bearing model and number for motor including necessary greasing, check for proper shaft alignments, vibration pads, such that no vibratiobn produce during opertion of following capacity Motors. |
| 13 | Bearings suitable for motor coupled with 200 HP pump |
| 14 | Bearings suitable for motor coupled with 150 HP pump |
| 15 | Bearings suitable for motor coupled with 120 HP pump |
| 16 | Bearings suitable for motor coupled with 75 HP pump |
| 17 | Bearings suitable for motor coupled with 60 HP pump |
| 18 | Bearings suitable for motor coupled with 40/50 HP pump |
| 19 | Bearings suitable for motor coupled with 30 HP pump |
| 20 | Bearings suitable for motor coupled with 20/25 HP pump |
| 21 | Bearings suitable for motor coupled with 15 HP pump |
| 22 | Bearings suitable for motor coupled with 10/7.5 HP pump |
| 23 | M&L for Disconnecting motor power cables of various sizes from electrical motor of different capacities and decoupling from the pump sets, removing and taking down carefully and transporting to authorised workshop, Dismantaling stator and rotor carefully and rewinding stator assembly with supper enamelled copper winding wire of suitable gauge matching to existing gauge and cleaning of slots, core with carbon tetra chloride solution and apply two coats of insulation varnish and keep stator assembly in heating chamber to improve insulation strength, reassemble motor completey and transporation to site, coupling pump to motor and check for proper shaft alignments such that no vibratiobn produce during opertioncoupling to pump with exact allinment, connect power cables to motor and testing of following capacity motor. |
| 24 | 200 HP |
| 25 | 150 HP |
| 26 | 120 HP |
| 27 | 75 HP |
| 28 | 60 HP |
| 29 | 40/45 HP |
| 30 | 15/20 HP |
| 31 | 5/7.5 HP |
| 32 | Supply and fixing in repairs MS ERW pipe heavy grade, ISI marked for suction and deliver for pump including necessary fittings, flanges, welding, and providing necessary PCC support, pipe may lay in trenches or fixed on wall, make a arrangement to frame the pipe in shape as requred on site by cutting and welding in peases painting with one coat of red oxide primer & two coat of synthetic enamel paint all as specfied and directed by Engineer-in-charge of following sizes :- |
| 33 | 300 mm dia |
| 34 | 200 mm dia |
| 35 | 250 mm dia |
| 36 | 150 mm dia |
| 37 | 100 mm dia |
| 38 | 80 mm dia |
| 39 | M& L for Disconnecting centrifugal pump from motor, suction and delivery pipe line of any Make, model and taking down packing for removing and insertion of new shaft sleeves or remove Bearings using bearing puller gear and fix new shaft sleeves including necessary greasing of all parts, coupling pump to motor and check for proper shaft alignments such that no vibratiobn produce during opertion of following capacity pumps complete all as specfied and directed by Engineer-in-charge. |
| 40 | Shaft sleeves coupled with 200 HP pump/motor |
| 41 | Shaft sleeves coupled with 150 HP pump/motor |
| 42 | Shaft sleeves coupled with 75 HP pump/motor |
| 43 | Shaft sleeves coupled with 60 HP pump/motor |
| 44 | Shaft sleeves coupled with 40/45 HP pump/motor |
| 45 | Shaft sleeves coupled with 20 HP pump/motor |
| 46 | Shaft sleeves coupled with 15 HP pump/motor |
| 47 | Supplying and laying or passing through pipe, 1100 volts grade heavy duty carpet grade cable with XLPE insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheather 300 Sq mm nominal cross sectional area 3½ core, laid in trenches and pipes, clamp on wall and pole, making good distrubed surface as existing surface complete all as specified and as directed by the Engineer-in-Charge. |
| 48 | Supply and fixing in repair HDPE Pipe of size 150 mm bore, PN 10 including jointing with collars/bends complete all as specified and directed. |
| 49 | Supply and fixing in repair HDPE Pipe of size 50 mm bore, PN 10 including jointing with collars/bends complete all as specified and directed. |
| 50 | Supply and fixing in repair only AC-3 type contactor with control voltage of 415V, AC, 50Hz with integrated auxillary or Add on block contacts with 1 or 2 No and NC including connection of control wiring to contactor and testing of starter after repairing . |
| 51 | Contactor 225–250 A motor current, use a 250 A AC-3 contactor, provided the manufacturer's AC-3 rating at 415 V is ≥ the motor's full-load current suitable for 200HP |
| 52 | Contactor 170–185 A motor current, use a 185 A AC-3 contactor, provided the manufacturer's AC-3 rating at 415 V is ≥ the motor's full-load current suitable for 150HP |
| 53 | Contactor 135–150 A motor current, use a 150 A AC-3 contactor, provided the manufacturer's AC-3 rating at 415 V is ≥ the motor's full-load current suitable for 120HP |
| 54 | Contactor 85–95 A motor current, use a 95 A AC-3 contactor, provided the manufacturer's AC-3 rating at 415 V is ≥ the motor's full-load current suitable for 75HP |
| 55 | Contactor 45–50 A motor current, use a 50 A AC-3 contactor, provided the manufacturer's AC-3 rating at 415 V is ≥ the motor's full-load current suitable for 40HP |
| 56 | Contactor 28–32 A motor current, use a 32 A AC-3 contactor, provided the manufacturer's AC-3 rating at 415 V is ≥ the motor's full-load current suitable for 25HP |
| 57 | Contactor 22–25 A motor current, use a 25 A AC-3 contactor, provided the manufacturer's AC-3 rating at 415 V is ≥ the motor's full-load current suitable for 20HP |
| 58 | Contactor 17–20 A motor current, use a 20 A AC-3 contactor, provided the manufacturer's AC-3 rating at 415 V is ≥ the motor's full-load current suitable for 15HP |
| 59 | Supply and fixing in repair thermal over load relay with adjustable setting with integrated auxillary or Add on block contacts with 1 or 2 NO and NC including connection of control wiring to OLR and testing of starter after repairing . |
| 60 | OLR of capacity I Min of 135 to I max 225 A with CT Make: L&T/Havells/C&S/Legrand or equivalent of approved make. |
| 61 | OLR of capacity I Min of 90 to I max 150A Make: L&T/Havells/C&S/Legrand or equivalent of approved make. |
| 62 | OLR of capacity I Min of 60 to I max 100A Make: L&T/Havells/C&S/Legrand or equivalent of approved make. |
| 63 | OLR of capacity I Min of 42 to I max 70A Make: L&T/Havells/C&S/Legrand or equivalent of approved make. |
| 64 | OLR of capacity I Min of 28 to I max 46.5A Make: L&T/Havells/C&S/Legrand |
| 65 | Supply, installation, testing and commissioning of LT Panel board indoor type in repair wit IP54 Protection panel manufacturer made out of of 2mm CRCA sheet cubical totally enclosed with frame made out of 50mm x 50mm x 6mm angle iron door front and back openable with locking arrangement indoor type vermin and weather proof floor mounting type, suitable for 3 phase 4 wire, 50 HZ, 415 Volt AC supply with 600A of high conductvityelectrolytic copper bus bar (4 Nos) All MCCB shall be connected with suitable size of copper strip from main bus & with terminate point, with adequately supported with high-quality SMC/DMC insulators. Suitable shrouding/barriers to prevent accidental contact. Earth busbar throughout the panel. and complete wiring of panel board with suitable size PVC insulated multistranded copper conductor including lugs/thimbles etc with suitable cable alley for provn of cable entries at bottom with cable glands including the following :-(a) MCCB 4 pole, 415V, AC, 400 Amps 50 KA - 02 No (incoming) (Main+DG) thermo magnetic adjustable release type,ICS=ICU=100% (b) MCCB 3 pole, 415V, AC, 100 Amps 36 KA - 05 Nos (4 Nos for starter 40 HP + 01 Standby) thermo magnetic adjustable release type, ICS=ICU=100% Make: L&T/ABB/Siemens/legrand/IndoAsian/Havells/ HPL/ Schneider/ Standard(c) Automatic star/Delta starters with all accessories mounting suitable for 40 HP-04 Nos. (d) On load Change over Switch 400A, 415V, AC, 50Hz, 3 terminal - 01 No(e) Single phase preventor for for each motor(f) Overload protection for each motor(g) Phase failure protection and Phase sequence protection. |
| 66 | (h) Short-circuit protection through MCCBs.(j) Emergency stop provision(k) Motor ON/OFF/TRIP indication.(l) Individual motor run-hour indication(m) Auto/Manual operation facility.(n) Interlocking provision between pumps, (o) Provision for remote/SCADA start-stop and status feedbackNote:- Size of the planel (LxBxH) shall be match with existing panel installed at installation |
| 67 | Supply, installation, testing and commissioning of LT Panel board indoor type in repair wit IP54 Protection panel manufacturer made out of of 2mm CRCA sheet cubical totally enclosed with frame made out of 50mm x 50mm x 6mm angle iron door front and back openable with locking arrangement indoor type vermin and weather proof floor mounting type, suitable for 3 phase 4 wire, 50 HZ, 415 Volt AC supply with 800A of high conductvityelectrolytic copper bus bar (4 Nos) All MCCB shall be connected with suitable size of copper strip from main bus & with terminate point, with adequately supported with high-quality SMC/DMC insulators. Suitable shrouding/barriers to prevent accidental contact. Earth busbar throughout the panel. and complete wiring of panel board with suitable size PVC insulated multistranded copper conductor including lugs/thimbles etc with suitable cable alley for provn of cable entries at bottom with cable glands including the following :-(a) MCCB 4 pole, 415V, AC, 630 Amps 50 KA - 01 No (incoming) thermo magnetic adjustable release type,ICS=ICU=100% (b) MCCB 3 pole, 415V, AC, 400 Amps 36 KA - 03 Nos (3 Nos for starter 150 HP ) thermo magnetic adjustable release type, ICS=ICU=100% Make: L&T/ABB/Siemens/legrand/IndoAsian/Havells/ HPL/ Schneider/ Standard/C&S(c) Automatic star/Delta starters with all accessories mounting suitable for 150 HP-03 Nos. (d) Single phase preventor for for each motor(e) Overload protection for each motor(f) Phase failure protection and Phase sequence protection. |
| 68 | (g) Short-circuit protection through MCCBs.(h) Emergency stop provision(j) Motor ON/OFF/TRIP indication.(k) Individual motor run-hour indication(l) Auto/Manual operation facility.(m) Interlocking provision between pumps, Note:- Size of the planel (LxBxH) shall be match with existing panel installed at installation Please Enable Macros to View BoQ information |
| 69 | (g) Short-circuit protection through MCCBs.(h) Emergency stop provision(j) Motor ON/OFF/TRIP indication.(k) Individual motor run-hour indication(l) Auto/Manual operation facility.(m) Interlocking provision between pumps, Note:- Size of the planel (LxBxH) shall be match with existing panel installed at installation Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender