Tender For Servicing/Maintenance Of Ht Vcbs, Lt Panels & Transformer And Other Miscellaneous Works At Slipway And Degaussing Bay At Sbc Under Naval Dockyard Visakhapatnam Under Ge (I) (Dm) Visakhapatnam

Issued by Statutory Bodies & Commissions/Committees · Visakhapatanam, Andhra Pradesh
Tender Value
42.65 Lakhs
Estimated cost
Bid Submission
09 Dec 2026
17 days left
EMD
85300
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Visakhapatanam → Andhra Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Servicing/Maintenance Of Ht Vcbs, Lt Panels & Transformer And Other Miscellaneous Works At Slipway And Degaussing Bay At Sbc Under Naval Dockyard Visakhapatnam Under Ge (I) (Dm) Visakhapatnam

BOQ

Name of Work:- SERVICING/MAINTENANCE OF HT VCBS, LT PANELS & TRANSFORMER AND OTHER MISCELLANEOUS WORKS AT SLIPWAY AND DEGAUSSING BAY AT SBC UNDER NAVAL DOCKYARD VISAKHAPATNAM UNDER GE (I) (DM) VISAKHAPATNAM
Sl. No. Item Description
1Overhauling and servicing of 400 Amp to 800 Amp 11 KV HT breakers for proper functionalling including/ repairs, replacement of defective worn out components and refixing back including testing and commissioning with comprising the following:-(a) Disconnecting form socket contacts, cleaning and adjustment of gap, replacement of rings etc. (b) Checking the brekaer bushing of bus bar and circuit side, inspection/ servicing of internal surface for any arcing/ tracks.(c) Checking the epoxy body completely for any cracks, any sign of arcs/ tracks, cleaning thorougly with CTC including applying bectrol red varnish if necessary.(d) Checking the drive rod & drive beam insulator assembly and inspect for chocking/ tracks/ arcing.(e) Checking the condition of the spring charging motor along with gear box including servicing the motor & replacement of motor bearings if required.(f) Checking/ servicing of ratchet wheel assembly, driving and charging parts.(g) Chekcing the auxiliary switch, its contacts for proper functional operation.
2(i) Checking & servicing of raising/ lowering mechanisim and its locking system for proper functioning.(j) Checking & servicing of shutter assembly for its automatic opening/ closing(k) Testing of VCB to confirm healthiness up to satisfactory results before reinserting in VCB panel. (i) Insulation Resistance test with 5000V digital insulation tester.(ii) Timing test at 70%, 100%, of rated control voltage.(iii) Contact Resistance Measurement test.(l) Replace both the closing & tripping buffers and if required adjust VCB timing up to satisfactory limit.Note :- (i) Test results should be submitted to Engineer in-Charge to keep on record duly signed by all concerened complete all as specified and as directed.Submission of latest and valid calibration certifcate of all used testing kits and equipment from reputed laboratories approved by NABL. Calibration should be carried out through authorised CEIG Licenced agency only. (ii) Any abnormality found during testing, same shall be brought to the notice of Engineer in -Charge. (iii) The items like testing equipment, nuts, bolts, spring washers, petroleum jelly, CTC etc. Required to put the breaker in serviceable condition shall be supplied by the contractor and rate shall be deemed to be included in the unit rate quoted.
3Supply only Resin Cast CT dual core, CT ratio - 100/50/5A-5A for 800A to 2500A Schneider make 11 KV VCB all as specified and directed.
4Supply and fix space heater, 230V, 100 Watt inside cable chamber including necessary connection, testing complete all as specified and directed.Make: Schneider, Part No. EHT-A-AA000-001
5Supply and fix including dismantling taking out unserviceable thermostat for space heater for 800 A to 1600 A Schneider make 11 KV VCB compete all as specified and directed.Make: Schneider only, Part No ETH-E-B000-001
6Supply and fix including dismantling taking out unserviceable Buffer (For Opening Spring ) For 630A to 800A Schneider make 11 KV VCB complete all as specified and as directed. Make-Schneider only, Part No- MVIJ00098-01
7Supply and fix including dismantling taking out unserviceable Buffer (For Closing Spring ) For 630A to 800A Schneider make 11 KV VCB complete all as specified and as directed. Make-Schneider only, Part No- MVIJ00056-01
8Supply and fix including dismantling taking out unserviceable single (Read-Blue) phase busbar spout suitable for 630A to 800A VCB complete all as specified and as directed. Make-Schneider only, Part No- MEP-39-32185
9Supply and fix including dismantling taking out unserviceable single (Y) phase busbar spout for 630A to 800A 11 KV VCB complete all as specified and as directed. Make :- Schneider Model No MEP-39-32186
10Supply and fix including dismantling taking out unserviceable CT Spout suitable for VCB 630A to 800A complete all as specified and as directed.Make :- Schneider Model No MEP-39-32187
11Supply & fixing closing coil assembly 110 V DC to Schneider make 11KV VCB incl necessary connection testing complete incl dismantling taking down unsv one complete all as specified and as directed.. Make- Schneider, Part No- ECO39SN134900FN
12Supply and fixing tripping coil 110 V DC to Schneider make 11KV VCB incl necessary connection testing complete incl dismantling taking down unsv one complete all as specified and as directed.. Make- Schneider, Part No- ECO39SN134100FN
13Supply and fix including dismantling taking out unserviceable Breaker Wheel - CAST IRON, For 630A to 800A 11 KV VCB complete all as specified and as directed. Make-Schneider only, Part No-MVIA00025-01
14Supply and fix including dismantling taking out unserviceable spring charging Universal motor with gear box 220V AC For 630A to 800A 11 KV VCB complete all as specified and as directed. Make :- Schneider only, Part No-MVIJOO157-02
15Supply and fix including dismantling taking out unserviceable busbar supporting insulator For 630A to 800A Schneider make 11 KV VCB complete all as specified and as directed. Make :- Schneider only , Part No- MEP-39-A0147901
16Supply and fix including dismantling taking out unserviceable Drive Beam suitable for 11 KV VCB 630A to 800A complete all as specified and as directed. Make :- Schneider only Model No MSM3950118600FN
17Supply and fix Epoxy Body suitable for 11 KV VCB up to 630 Amps complete all as specified and as directed. Make :- Schneider only Model No MEP3953022000FN-22
18Supply and fix including dismantling taking out unserviceable Shutter assembly for busbar / circuit spout suitable for 11 KV VCB up to 630A to 800A all as specified and directed.Make:- Schneider only Model No SPP0009-04.
19Supply only Busbar anodised aluminium off sizes including required drilling holes for fixing with other bus / cable connections all as specified and directed.
20Supply only Busbar anodised copper off sizes including drilling holes for fixing with other bus / cable connections all as specified and directed.
21M&L for maintenence/servicing of PT unit 11KV / 110V by disconneting and taking out from panel mounted position, checking & cleaning of fixed and moving contact points, cleaning/ decarbonising of busbar connections, resin cast PTs using hot blower, CTC solution to the epoxy PT body, tightening of all nuts, bolts, washers, and refixing the same PT to original position, testing complete all as specified and directed.
22Taking out old UNSV LT UG cable of any size and any description including GI pipe of any dia and bricks for cable protection where ever appeared and all as directed by Engineer-in -charge. Note:-(1) Excavation and earth work shall bemeasured and paid separately.(2) Serviceable cable obtained shall be stacked properly for re use. Please Enable Macros to View BoQ information
23Taking out old UNSV LT UG cable of any size and any description including GI pipe of any dia and bricks for cable protection where ever appeared and all as directed by Engineer-in -charge. Note:-(1) Excavation and earth work shall bemeasured and paid separately.(2) Serviceable cable obtained shall be stacked properly for re use. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58602938
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 42.65 Lakhs
LAST DATE 09-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Servicing/Maintenance Of Ht Vcbs, Lt Panels & Transformer And Other Miscellaneous Works At Slipway And Degaussing Bay At Sbc Under Naval Dockyard Visakhapatnam Under Ge (I) (Dm) Visakhapatnam
Basic Detail
Tender No 8735/C/E8
Bidding Type Tender
Location
City Visakhapatanam
State Andhra Pradesh
Key Dates
Publish Date 18 Nov 2026
Submission Date 09 Dec 2026
Open Date 11 Dec 2026
Finance
Tender Value 42.65 Lakhs
Tender Fee 500
EMD 85300
Exemption Available
Document List
7166d041-e419-404e-98ba-e5e9f748f61e.html
8735Tender.pdf
BOQ_896758.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Dec 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

7166d041-e419-404e-98ba-e5e9f748f61e.html

pdf

8735Tender.pdf

xls

BOQ_896758.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender