Rural Development Government Departments Closing in 12 days TDR #58602651

Tender For Construction Of 24X7 Phc Building At Mandibisi Of Kashipur In The District Of Rayagada For The Year 2025-2026.

Issued by Government Departments · Rayagada, Odisha
Tender Value
1.92 Crore
Estimated cost
Bid Submission
04 Dec 2026
12 days left
EMD
1.92 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Rayagada → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of 24X7 Phc Building At Mandibisi Of Kashipur In The District Of Rayagada For The Year 2025-2026.

BOQ

Name of Work:- Construction of 24x7 PHC Building at Mandibisi of Kashipur in the district of Rayagada for the year 2025-2026.
Sl. No. Item Description
1Earth work in excavation in foundation in hard soil including hard moorum, stoney earth mixed with boulders (except sheet rock & builders requiring blasting) with all leads and lifts including dressing and leveling the bed and depositing the excavated earth at places away from work site with all leads and lifts including cost of all labour, Cess and T&P and dewatering if required for the work etc. complete and directed by the Engineer-in-charge.a) Ground Floor
2b) Approach Road
3Excavation of founation in hard rock (granite) removed by chiselling including dressing and levelling the bed not exceeding 1.5m in depth and depositing the soil within initial lead of 50m and as per specification approved by the DepartmentGround Floor
4Providing & filling mannually with excavated earth materials including watering ramming to proper density with all leads and lifts including cost of all labour T & P& Cess required for the work etc complete as per specification & direction of Engineer-in-charge.a) Approach Road
5Supplying and filling in foundation & plinth with sand in 23.5 cm (9\\") thick layers including watering and ramming with cost, conveyance, Royalty, DMF, EMF & Additional Charges of all materials, and labour with T&P required for the work including Cess etc complete. (Measurement will be taken on finished compacted section only) as per direction of Engineer-in-Charge.a) Ground Floor
6b) Approach Road
7Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment).Ground Floor
8Providing cement concrete of proportion (1:3:6) in foundation and floors using 4cm (3/2\\") size clean hard black hand broken granite stone metal of approved quality and from approved quarry including hoisting lowering and laying concrete in layers not exceeding 15cm (6\\") thick to the required level ramming, watering & Curing etc. complete including cost & conveyance of all materials with all Royalty, DMF, EMF & Additional Charges and all labour with T&P required for the work with Cess etc, complete including dewatering if required as per direction of Engineer In Charge. a) Ground Floor
9First class Fly ash Brick masonry using bricks of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge.a) Ground Floor
10Fly Ash. brick masonry of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:6) with approved grade cement and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Superstructure including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-chargeGround Floor
11Fly Ash. brick masonry of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:6) with approved grade cement and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Superstructure including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge Terrace Floor
12Half brick work with Fly Ash brick masonry in cement mortar (1:4) in super structure having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.Ground Floor
13RCC work of grade M-20 having a minimum compressivestrength in work text of 200Kg/cm2 in15cm cubesat 28daysafter mixing and tests conducted using 10mm to 20mm size (20mm not to exceed 25 percent) crusher black broken granite stone chips of approved quality and from approved quarry including hoisting,lowering and laying concrete by using vibrators watering and curing for four weeks centering and shuttering and finishing the exposed surface smooth to receive painting or white or clour wasing providing grooves or beads where neCessary including cost, conveyance and Royalty, DMF, EMF & Additional Charges of all materials and labour required for the worketc, complete with all T&P and Cessin all respect but execludingcost of reinforcement MS rods or tor steel and binding wires of 18 to 20 guage and labour charges etc, complete as per specification and direction of Engineer-in-charge. Footinga)Ground Floor
14Column up to plinth & above plinth upto Roof levelGround Floor
15Plinth BeamGround Floor
16Column in super structureTerrace Floor
17Lintela)Ground Floor
18b)Terrace Floor
19Chajjaa)Ground Floor
20b)Terrace Floor
21Roof Beama)Ground Floor
22b)Terrace Floor
23Roof Slaba)Ground Floor
24b)Terrace Floor
25Stair caseGround Floor
26Supplying ,fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specificationa)Ground Floor
27b)Terrace Floor
2812mm (1/2\\") thick cement plaster in C.M (1:6) finsihed smooth to out side brick walls after racking out the joints including watering & curing for seven days with cost and conveyance of all materials and laobur with T&P required for the work with all , Royalty, DMF, EMF & Additional Charges & Cess etc, complete in all floors as per direction of Engineer-in-charge. a)Ground Floor
29b)Terrace Floor
3016mm (5/8\\") thick cement plaster in C.M. (1:6)finished smooth to inside surface of 9\\" thick brick wall after racking out the joints including watering & curing for seven days with cost and conveyance of all materials and labour with T&P required for the work with all , Royalty, DMF, EMF & Additional Charges & Cess etc, complete in all floor as per direction of Engineer-in-charge. a)Ground Floor
31b)Terrace Floor
326mm thick cement plaster in cement mortar (1:4) to ceilling of roof lintel and chajjas after chipping and chiselling the same and clearing the surface by wire brush finished smooth watering and curing for 7 days including cost,conveyance of all materials and labour with T&P & Cess required for the work withand Royalty, DMF, EMF & Additional Charges etc complete in all respects in all floors as per direction of Engineer-in-Charge. Ground Floor
33Supplying, fitting & fixing of Granite Tiles of minimum Above 0.40 sqm. (20mm thick) of approved make in floors laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with slurry including cost of all materials, labour T&P etc. required for the work all complete incl. rubbing as per direction of the Engineer-in-chargeGround Floor
34Fixing Vitrified tiles in dados skirting and risers of steps on 12mm thick CP (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including cost, carriage, cost of all labour etc. complete.Ground Floor
35Supplying,fitting & fixing vetrified tile in floors of size 600mm x 600mm of approved make conforming to IS:13755laid on 20 mm thick cement mortar 91:4) (1 cement:4 course sand) and filling joints with white cement of approved quality including with cost, conveyance,Royalty, DMF, EMF & Additional Charges ,of all materials & labour T&P and Cess required for the work all complete as per direction ofEngineer-In-Charge.Ground Floor
36Supplying and fitting,fixing of Un-plasticised poly vinyl Choloride (UPVC) (FENESTA / NCL VEKA LTD) Cashment Door- 60 series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mm x 2.5mm for outer frames,102 mm x 60 mm x 2.25 mm case ment door sash profile and 74 mm x 60 mm x 2.5 mm mullion profile capable of mounting single glazing system,structurally reinforced with hot dip galavanised up to 50 microns of minimum thickness of 2.0 mm prefabricated & welded through fusion welding the door sash shall be fitted with 12 mm thick WPC board of greenply make duly fixed with EPDM weathering seal resistant accessories like clippinglocking system made of aluminium 1 No. per set of sashes and the system is to be installed at the site using anchor fasteners,silicon rubber sealant ,easy glazing / deglazing at site etc. including cost and conveyance of all materials,accessories,labour charges,materials and product conforming to ASTM D 638-14 ,EN-477-95 and other applicable codes and standards.Ground Floor
37Supplying and fitting-fixing of Un plasticised Poly Vinyl Chloride(UPVC) ( FENESTA / NCL VEKA LTD.) Three Track Three Panel sliding window60Series duly manufactured using UPVC reinforced profiles of 108mm x 45 mm x 2.5 mm for outer frames and Window Sash of 39 mm x 58 mm x 2.5 mm capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window frame shall be fitted with 6 mm thick clear toughened glass of SAINT GOBAIN make duly fixed with EPDM weathering seal resistant and the system is to be installed using Reinforced Large Coupler at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges, materials and product conforming to ASTM D 638-14,EN 477 95 and other applicable codes and standards.a) Ground Floor
38b)Terrace Floor
39Supplying & providing, of M.S. window grill made out of M.S flat conforming to IS No -1977/1996 as per the design approved with cost, conveyance &of all materials & labour with T&P & Cess in all respects as directed by the Engineer-in-Charge.a) Ground Floor
40b)Terrace Floor
41Supplying fitting of Stainless steel of 304 garde in hand railing using 50 mm dia of 2 mm thick circular pipe with balustarade of size 32mm X 32 mm X X2 mm in 3 rows in stair case as per approved design and specification buffering polisging etc. including cost conveyance of all materials complete as per direction of the Engineer- in - Charge.Ground Floor
42Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, taxes of all materials, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge.a)Ground Floor
43b)Terrace Floor
44Finishing wall surface of walls with Acrylic wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materialslabour T&P with Cess etc complete as per direction of Engineer-in-Charge. a)Ground Floor
45b)Terrace Floor
46Painting two coats with approved plastic emulsion paint over a coat of wall primer of make Dulux / Berger / Asian to inside surface of walls finished with Acrylic Wall putty (water based) of make (Birla / JK) and finished smooth & even surface to receive painting using roller to the final coat including cost of scaffolding staging charges with cost, conveyances, taxes of all materials, cost of labour, T&P required for the work etc. complete for all floors as per specification & direction of the Engineer-in-charge. Ground Floor
47Painting two coats with approved plastic emulsion paint over a coat of wall primer of make Dulux / Berger / Asian to inside surface of walls finished with Acrylic Wall putty (water based) of make (Birla / JK) and finished smooth & even surface to receive painting using roller to the final coat including cost of scaffolding staging charges with cost, conveyances, taxes of all materials, cost of labour, T&P required for the work etc. complete for all floors as per specification & direction of the Engineer-in-charge. Terrace Floor
48Painting two coats with approved anti-fungal weather seal paints (ISI) of approved colour, shade on wall surface over a coat of wall primer(ISI) water bound including sand papering, polishing the surface, cost, conveyances of all materials and cost of all labour,labour cess with T&P etc, complete as per specification & direction of Engineer-in-charge.a)Ground Floor
49b)Terrace Floor
50Priming one coat with any approved primmer (To Receive Enamel paint) including cost of primmer & labour to give an even shade excluding cost of primer. (As per A.R. 93/1)a) Ground Floor
51b) Terrace Floor
52Painting two coats with any approved paint over a coat of priming to Iron work including cost of the primer and paint sand papering polishing the surface with cost conveyance andof all materials and labour with T&P required for the work with Cess etc, complete as per the direction of the Engineer-In-Charge. a)Ground Floor
53b)Terrace Floor
54Providing 2.5Cm. thick grading concrete (1:2:2) on roof slab with 6mm size hard broken granite chips including cost conveyance Royalty, DMF, EMF & Additional Charges of all materials, labour T&P, Cess etc. complete as per direction of EIC.Terrace Floor
55Providing cement concrete of proportion (1:3:6) in foundation and floors using 4cm (3/2\\") size clean hard black hand broken granite stone metal of approved quality and from approved quarry including hoisting lowering and laying concrete in layers not exceeding 15cm (6\\") thick to the required level ramming, watering & Curing etc. complete including cost & conveyance of all materials with all Royalty, DMF, EMF & Additional Charges and all labour with T&P required for the work with Cess etc, complete including dewatering if required as per direction of Engineer In Charge. Approach Road
56Providing and laying 80 mm thick factory made cement concrete interlocking paver block of M-35 grade made by block making machine with storng vibratory compaction of approved size, design & shape, laid in required colour and pattern over and including 75mm thick sand filling.as per drawing, specification and direction of Engineer-In-charge.Approach Road
57Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150mm thick, foundation having 50mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408 Approach Road
58Electrical WorkWiringRecessed wiring to light point with 1.5 sq.mm FR PVC insulatedsingle core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5Amp, 250 V piano type modular switch ISI marked and ceiling rose ISI marked mounted on MS box having front Modular base & cover of suitable size , MS box with 1 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels /HPL/ V Guard ) -do- Group A
59-do- Group B
60-do- Group C
61Recessed wiring to Fan Point in... -do- Group B
62-do- Group C
63Recessed wiring to Call Bell Point in... -do- Group B
64Recessed wiring to Exhaust Fan Point indo Group B
65-do- Group C
66S/F of Angle holder replacing Ceilling Rose
67S/F of fan hook 'S' type made of 16 mm MS rod for fixing in the Existing RCC Roof.
68Switch BoardS/F of 5A. Modular Switch & 5A. Modular Socket outlet of ISI marked on existing board (1.25.1+1.25.4)
69S/F of extension board of 6 modular Metal box with modular base & cover in recess including providing and fixing of 2 nos of 3pin 5/6amp modular socket out let & 2 nos of 5/6 amp piano type modular switch, connection, painting etc as required.
70S/F of Power point with 4 modular metal box with modular base & cover in recess including providing and fixing of 6 pin 15/16 amp. piano type Modular switch & Socket, connection, painting etc as required
71S/F of Power point with 4 modular & 2 modular metal box with modular base & cover in recess including providing and fixing of 5 pin 15/16 amp. piano type Modular switch & Socket & 20Amp AC Starter , connection, painting etc as required for AC
72S/F of computer board consisting of 3 nos of 5amp modular plug and modular switch & 1 no of Mini MCB complete with wiring on 12 modular M.S. box with modular cover.
73S/F of 1 no of 5 pin 15/16 amp. Socket , 1 no of switch & 1 no of 15/16A top with modular mini MCB, in 6 modular box with cover with connection, painting etc as required for Inverter connection.
74S/F of 18 SWG Modular metal box of following sizes (Nominal size) in recess with suitable size of Modular base & cover in front including cutting the wall and making good the same in case of recessed conduit as required. 2 Modular box with base & cover
754 Modular box with base & cover
766 Modular box with base & cover
778 Modular box with base & cover
7812 Modular box with base & cover
79Sub- MainWiring for circuit / sub-main wiring along with earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20mm dia non metalic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required (Make of wire - Finolex/L&T/Anchor/Havels/V-guard) 2x1.5+1x1.5 (1.8.1)2x1.5+1x1.5 (1.8.1)
802x2.5+1x1.5 (1.8.2)
812x4+1x1.5 (1.8.3)
824x6+2x2.5(1:8:10)
83Inverter wiring (1x2.5smm) Copper wire (1.19.11A)
84Circuit Breakers & BDBS/F of 'B/C/D' series SP MCB of 5 - 32A amp rating (As per direction of engineer in charge) 240Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required single pole (SP) (2.6.1)
85S/F of 'B/C/D' series DP MCB of 5 - 32A amp rating (As per direction of engineer in charge) 240Volt for lighting and other loads in the existing Distribution board ISI marked complete with connection, testing and commissioning etc. as required (2.6.2a)+(2.3.1b)
86S/F of 'C' series 4 Pole MCB of 63A amp rating (As per direction of engineer in charge) 440Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required without MCB box.
87Supply, Installation testing & commissioning of Main Switches (IS13940 part 3/1993) of following coopacity on existing surface/wall mounting & complete with H.R.C fuse links, inter connections earthing etc as required as per direction of Engineer Incharge (Make-Seimens/HPL/Anchor/L&T /Havels/C&S/R. K.) S/F of MCB 4 way Double Door (2.3.5 )
88S/F of MCB 12 way Double door (2.3.7)
89S/F of 4 way (4+12) TPN MCB DB Single door (2.5.1)
90S/F of 6 way (6+18) TPN MCB DB double door (2.5.6)
91EarthingSupply & laying 8 SWG Cu wire in recess for loop earthing as required (3.18)
92S/F of Cu .Earth Plate Earthing 600 mm x600mmx3.15mm with Salt & Charcoal for Earth electrode (3:5)+(3.6)
93FittingsS/F of 300 Exhaust fan with all accessoriesand connections (Make Usha-Aero Clean Plus DBB/ Polycab-Fresh on DBB/ Cropmton-Trans Air12\\" reversible/ Havells-Ventil Air DS(HS)/ Anchor-Anmol Delus R/ Orient-Power Flow DBB)
94S/F of Call bell/Buzzer(Ding dong type) ISI marked suitable for DC/AC single phase 230 volts complete as required. (1.30)
95S/F of 18-25 wt. LED single strip tube. Light fittingwith all accessories & connection (make Havels/HPL/Crompton/Polycab/PAC)
96S/F of 1200mm A.C. Ceiling fan (1Star) with all accessories and connections with out fan regulator (Make:Usha-Striker One/Neo/Crompton- highspeed/Havells-Samrat ES/Anchor- Turbo Speed Star/Orient-Summer Breeze Pro/ Great White-ALDOUS/Pollycab-Vital HS)
97Fixing /I.T.C. of stepped type Modular regulator (1.25a)
98S/F of 20mm dia down rod with all accessories (1.39+1.41)
99Supply & fixing of superior type C.I bulk head fitting with 9W Led Bulb for general domestic use ISI marked square / oval type with premetallic glass cover provided with galvanized steel wire guard including necessary connections. ( M-5 )
100S/F of 60 wt. LED St. Light fitting with LED Electronic driver with all accessories & connection( Make- Crompton/Phillips/HPL/Polycab/Havells )
101S/F of 12w Watt LED Bulb
102S/F of Stabilizer (110-300V) 4KVA with 16A Delux plug Top(Make- V-Guard/Microtek)
103S/F of 12W LeD Squre (10\\"×10\\") LSDSMN-12W-WW with surface Panel rings (Havels/crompton/philips/panasonic)
104S/F of 18W LeD Squre (12\\"×12\\") LSDSMN-12W-WW with surface Panel rings (Havels/crompton/philips/panasonic)
105S/F of 2000VA/24V Invertor machine,Make-Heavy duty V-Turbo UPS-23509 (microtek)/PRIME 2250(V-GUARD)/EVO S 2300(LUMINOUS) and 180Ah tall tubular BatteryMake-Luminous /microtek/v-guard and 16A Delux plug Top with Luminous single Trolley for Inveryor Battery,2nos
106S/F of 1.5T ,5Star,Inverter model, Split A.C Machine (Make- Hitachi(V518PCBISH1)/Blue star(V518PCBISH1C)/Carrier(CAI19CE5R35F0)/Daikin/LG/Mitsubishi/O-General)
107Portable Fire Extinguisher System Supplying, installation, testing and commissioning of CO2 type Fire Extinguisher 4.5 kg capacity confirming to IS: 2878 made from ISI marked seamless cylinder confirming to IS: 7285, fitted with ISI marked controlled valve confirming to IS: 3224, high pressure 1mtr discharge hose & horn complete with initial gas charged with carrying handle & wall mounting bracket as per direction of Engineer-in-charge. (Make:CS-FIRE/SUNMAX/CANEXE or equievalant )
108CablesProvision of Armoured cable size 3 1/2 x70sqmm (27)
109Laying of MV cable above 25sqmm to 120 sqmm in ground (5.1.2)
110Laying of MV cable above 25sqmm to 120 sqmm on surface (Horizontally)(5.5.2)
111S/M of end termination of LV/MV cable size 3 1/2 x70 sqmm (5.8.23)
112Supply & fixing of 100 A TPN Panel board 1. 100A MCCB (Make- Legrand/Seimens/L&T/C&S/) & 100A kitkat & bus bar2. 32 A TPN MCB (Make- Legrand/Seimens/L&T/C&S/)- 2nos 3. 32A DP MCB (Make- Legrand/Seimens/L&T/C&S/)- 5 nos 4. 100 A 4P Manual changeover (Make- Legrand/Seimens/L&T/C&S/)- 1nos5. Digital Volt meter & Ameter three phase 6. All accesories & Connection (Rating & Danger borad)
113PH Work50 User Septic tank 2 NosEarthwork in all kinds of soil in excavation of foundation trenches within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth etc all complete as per direction of the E.I.C. Initial lift upto 1.5 mtr 1x 5.80 m x 3.20 m x 1.50 m=27.84 cum 2 Nos
114From 1.5 mtr to 3.0 mtr depth 1 x 5.80 m x 3.20 m x 1.50 m=27.84 cum 2 Nos
115Supplying all materials, labour, T&P and filling in foundation and plinth with river sand well watered and rammed including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per the direction of the E.I.C.1 x 5.80 m x 3.20 m x 0.15 m=2.784 cum 2 Nos
116Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 40mm H.G metal including watering, curing and conveyance of all materials to site payment of royalry, taxes etc all complete as per P.H specification and direction of the E.I.C.1 x 5.80 m x 3.20 m x 0.15 m=2.784 cum 2 Nos
117Supplying all materials, labour, T&P and providing plain cement concrete (1:1.5:3) with 12mm size H.G chips including watering, curing and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.1 x 5.80 m x 3.20 m x 0.10 m=1.856 cum + 1 x 4.00 m x 1.40 m x 0.038 m = 0.212 Cum 2 Nos
118Supplying all materials,labour, T&P and providing Brick work with K.B.Brick having crushing strength not less than 75 Kg/CM2 with dimensional tolerence of +/- 8% in C.M including watering, curring, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.In Foundation and Plinth in C:M (1:4) 2 x ( 5.50 + 1.40 ) m x 0.75 m x 0.75 m = 7.762 cum + 2 x ( 5.26 + 1.40 ) m x 0.63 m x 0.75 m = 6.293 cum + 2 x ( 5.00 + 1.40 ) m x 0.50 m x 0.75 m = 4.80cum +2 x ( 4.70 + 1.40 ) m x 0.35 m x 0.75 m = 3.202cum 2 Nos
119In Superstructure in C:M (1:6) 1 x 0.50 m x 0.50 m x 0.50 m = 0.125cum 2 Nos
120Supplying all materials, labour, T&P and providing cement plaster on brick/stone work including watering,curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. 20 mm thick C.P in C:M (1:3) 2 x ( 4.00 + 1.40 ) m x 3.00 m =32.40sqm + 1 x 4.00 x 1.40 m = 5.60 sqm+ 2 x ( 4.70 + 2.10 ) m x 0.75 m =10.20sqm + 4 x 0.50 x 0.50 m = 1.00 sqm 2 Nos
121Supplying all materials, labour, T&P and providing cement punning on plastered surface including watering,curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. Same as item 20mm C.P in 1:3 = 2 Nos
122Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. 2 x ( 4.70 + 2.10 ) m x 0.15 m = 2.04 sqm + 1 x 4.00 m x 1.40 m = 5.60 sqm 2 Nos
123Supplying all materials, labour, T&P and providing M.S.reinforcements for RCC work including cutting, bending, binding, straightening and tying the grills and placing in position including cost of binding wire 18 to 20 gauge conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. 2 Nos
124Supplying all materials, labour, T&P and providing reinforced cement concrete (1:1.5:3) with 12mm size H.G chips including watering, curing and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.1 x 4.70 m x 2.10 m x 0.15 m =1.48 Cum 2 Nos
125Supplying all materials, labour, T&P and making M.S. Step Iron in 20mm Dia M.S Steel bars and fixing into walls of Manhole/ Septic Tanks duly embeded in C.C(1:2:4) etc all complete as per P.H specification and direction of the E.I.C. 2nos
126Supplying all materials, labour, T&P and providing 50mm thick pre-cast R.C.C. baffle wall in R.C.C(1:1.5:3) including reinforcement cage using 12mm size HG chips fitted and fixed in position, finished smooth etc. complete including cutting grooves and mending good the damages etc all complete as per P.H specification and direction of the E.I.C.2 x 1.80 m x 0.45 m 2nos
127Supplying all materials, labour, T&P and providing 160mm dia P.V.C Tee inside the septic tank including cutting holes and duly embeded in P.C.C(1:1.5:3) using 12mm size HG chips fitted and fixed in position and mending good the damages etc all complete as per P.H specification and direction of the E.I.C. 2Nos
128Supplying all materials, labour,T&P and providing 12mm thick cement flush pointing in C:M (1:3) to Brick Masonry works including watering curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.2 x ( 5.50 + 2.90 ) m x 0.75 m = 12.60 Sqm + 2 x ( 5.26 + 2.66 ) m x 0.75 m =11.88Sqm + 2 x ( 5.00 + 2.40 ) m x 0.75 m =11.10Sqm + 2 x ( 5.50 + 2.66 ) m x 0.12 m =1.95Sqm + 2 x ( 5.26 + 2.40 ) m x 0.13 m =1.99Sqm + 2 x ( 5.00 + 2.10 ) m x 0.15 m =2.13Sqm 2 Nos
129Supplying all materials, labour,T&P and filling Foundation and Plinth with excavated earth including watering, ramming etc all complete as per direction of the E.I.C. 2 Nos
130Supplying all materials, labour, T&P and fixing porcelain glazed tiles in floors, on 25mm thick bed of cement mortar 1:1 joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. all complete as per specification and direction of the E.I.C. G.F 1x2.50x4.57m = 11.425 sqm+ 1x1.80x1.50m = 2.70 sqm + 1x7.62x5.25m = 40.00 sqm + 1 x 3.04m x 3.04m= 9.24 sqm + 1 x 1.20m x 1.95m= 2.34 sqm + 5x0.75mx0.30 m = 1.125sqm
131Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados/skirtings on 12mm thick cement plaster (1:3) joined with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing etc. all complete as per direction of the E.I.C.G.F 1x13.54mx2.10m =28.43 sqm+ 1 x6.0m x 2.10m = 12.60 sqm + 1 x25.14m x 2.10m = 52.794 sqm + 1 x11.56m x 2.10m = 24.27 sqm + 1 x5.70m x 2.10m = 11.97 sqm + 1 x 7.0m x 0.90= 6.30m + 1 x 2.50m x 2.10m=5.25 sqm + 6 x 1.80m x 2.10m= 22.68 sqm + 8 x 1.20m x 2.10m= 20.16 sqm+ 4 x2.30 x 2.10 m = 19.32sqm
132Supplying all materials, labour, T&P and fixing wash down water closet(E.W.C) with integral 'S' or 'P' trap(Hindware,Parryware,Cera) to the floor with wooden plug and C.P screw including jointing the trap with soil waste pipe in C.M(1:1) etc all complete as per specification and direction of the E.I.C. Single unit
133Wall mounted grab Bar
134Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing etc all complete as per P.H specification and direction of the E.I.C. 110mm diameter U-PVC SWR pipes
135110mm U-PVC SWR P-trap
136110mm U-PVC SWR single junction door
137110mm U-PVC SWR door bend
138110mm U-PVC SWR Offset
139110mm U-PVC SWR plain bend
140110mm U-PVC SWR vent cowl
14175 mm diameter U-PVC SWR pipes
14275mm U-PVC SWR door bend
14375 mm U-PVC SWR plain bend
144125 mm dia C.P Grating
145supplying all materials, labour, T&P and cutting holes through existing brick/stone masonry walls for taking HCI/PVC pipes and fittings including making good the damages in cement mortar (1:4) etc. all complete as per P.H. specification and direction of E.I.C.375 mm thick wall
146250 mm thick wall
147Supplying all materials, labour, T&P and laying in trenches U-PVC SWR/4kg/cm2 soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and providing bed concrete in P:C:C (1:4:8) using 40 mm size metal and haunch top the pipe with refilling of trenches etc all complete as per P.H specification and direction of the E.I.C.110 mm dia PVC Pipe haunch top
148Supplying all materials, labour, T&P and laying in trenches 4kg/cm2 U-PVC SWR soil waste ventilating pipes for sewer line of following dia in trenches (to slope or level)and jointing with supply of approved solvent cement by non-heat application method C.C (1:3:6) using 40mm size hard granite metal on bed of the trenches and all round concrete encashing with C:C (1:4:8) using 40 mm size H.G. metal, earthwork in excavation in trenches in all kinds of soil, refilling the same in a layer of 0.30mtr with watering, ramming and removing of surplus earth, testing the S.W. pipeline etc. all complete as per approved drawing, specification and direction of the E.I.C. 160 mm dia PVC Pipe all round
149Supplying all materials, labour, T&P and providing, laying soakway gallary with SW/PVC pipes, jointing lead loose packed allround with stone boulders 50mm to 150mm other than granite, covered at top with a layer of flat tiles 300mmx300mmx25mm including earthwork in excavation of trenches in all kinds of soil to an average depth of 1.5 mtr, covering of earth at the gallary top etc. all complete as per approved drawing and direction of the E.I.C.160 mm dia PVC gallary
150Supplying all materials, labour, T&P and constructing Inspection Chamber of the following sizes with cement concrete (1:3:6) using 40 mm size HG metal on bed, 1st class KB Brick work in CM (1:6) moulding and shaping the channel inside and benching with C:C (1:1.5:3) using 12 mm size H.G chips, 12 mm thick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in C.C(1:1.5:3) using 12 mm size H.G chips with RCC man hole cover, earth work excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per approved specification and direction of E.I.CInside size 760mm x 760mm x 460mm
151Supplying all materials, labour, T&P and constructing Gully Trap chamber of the following inside size with 8 cm thick precast cover slab in CC (1:2:4) mix using 12 mm size H.G chips, foundation concrete (1:4:8) using 40 mm size HG metal on bed and around trap , !st class KB Brick work in CM (1:6) in F & P and inside 12 mm thick cement plaster (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap 150mmx150mm size C.I grating etc. all completed as per approved drawing, specification and direction of E.I.C.
152Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class KB brick work in CM (1:6) for the remaining height at top, 12mm thick Cement Plaster (1:4) inside and outside over masonry brick work, gravel packing in the rear of well steining, RCC cover slab in CC (1:1.5:3) using 12mm HG chips, fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per approved specification and direction of the E.I.C. 1.20 m dia x 2.00 m deep Soakway pit
1531.40 m dia x 2.00 m deep Soakway pit
154Supplying all materials, labour, T&P and Fitting and Fixing of Rotational moulded polythene cylindrical vertical water storage tank conforming to 15701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jamnuts, including hoisting upto a height of 5 mtr above G.Land placing the tank in required position including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. 2000 lits capacity on the roof of G. floor
155Supplying all materials, labour, T&P and construction of masonry staging with providing 1st class K.B. Brick work in C.M.(1:6) of 0.46mtr height in staging, 12 mm cement plaster in C.M (1:6), R.C.C. Beam of 0.25mx0.30mx2.60m & roof slab of 1.40mx1.40m in C.C (1:1.5:3) using 12mm size H.G.Chips including centering, shuttering, bending and binding of rod etc watering, curring, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. 2000 lits capacity on the roof of G.floor
156supplying all materials, labour, T&P and cutting grooves in pucca Floors, and walls for taking G.I/PVC pipes and fittings and repairing the holes after insertion of pipes etc with C.C (1:3:6) including finishing with 12mm C.P (1:3) complete so as to make it leak proof etc. all complete as per P.H. specification and direction of E.I.C.
157Supplying all materials, labour, T&P and providing and fixing to wall or ceiling or floor G.I. pipes and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling,and floor, testing all complete as per specification and the direction of the E.I.C. 20mm dia PVC pipes
15825mm dia PVC pipes
15932mm dia PVC pipes
160Supplying all materials, labour T&P and fitting and fixing of C.P Shower(Jaquar) with 15mm or 20mm inlet with C.P Shower arm including polishing etc all complete as per specification and direction of the E.I.C. 15 mm x 150mm dia C.P Shower with arm
16115 mm dia C.P Health Faucet
162Supplying all materials, labour, T&P and fitting and fixing Brass/CP fittings(Jaquar) of the following nominal bore with supply of all jointing materials etc. all complete as per specification and the direction of the E.I.C.15mm dia CP Bib Cock
16315mm dia CP Bib Cock with long nose elbow action
16415mm dia CP long body Bib Cock
16515mm dia CP Pillar Cock Elbow action
16615mm dia CP Two way angle/Bib Cock
16715 mm dia CP Angle cock
16815mm dia CP Concealed Stop Cock
16915mm dia CP Pillar Cock
17015mm dia CP spreader
17115mm dia CP nipple
17215mm dia CP Flange
17325mm dia Metal Full Way Valve
174Supplying all materials, labour T&P and fixing wash basins(Hindware,Parryware,Cera) with C.I. or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the E.I.C.550mmx400mm W.H.basin
175Counter basin 560 x 455
176Supplying all materials, labour T&P and fitting and fixing Acraylic shelf including polishing all complete as per P.H. specification and direction of EIC. 450mmx125mm size Plate Acraylic Shelf with heavy good quality
177Supplying all materials, labour, T&P and fixing pedestrial for wash hand basin complete recessed at the back for the reception of pipes and fittings etc all complete as per specification and direction of the E.I.C.Porcelain Pedestal
178Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C.sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the E.I.C.Mirror with plastic moulded frame
179Supplying all materials,labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the E.I.C20mmx450mm long CP towel rail
180CP towel ring
181Supplying all materials, labour, T&P and fixing Stainless Steel kitchen sink/laboratory sink with C.I/M.S brackets paintedwhite including holes in walls and making good the damages fixing PVC waste pipe of 32mm nominal diameter including brass check nut complete, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the E.I.C. stainless steel kitchen sink(450x 400x200mm)
182Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the E.I.C CP soap holder
183CP liquid soap holder
184Providing fitting fixing Al door with anodized Al door section of 9202 as vertical member, 9201 as top, 9200 as bottom and middle member with frame section as 9221 with tapered clip no 4660 and frame to be completed by means of jointing angle no 1855 including cost of labour T&P hire charges of drilling machine labour charges etc complete with cost of laminated board. and as per direction of the Engineer in charge. 13x 0.70 m x 1.90m = 17.29sqm
185Supplying all materials, labour T&P and fitting and fixing 10 Ltrs capacity PVC low level flushing cistern(Hindware,Parryware,Cera) with a pair of C.I. or M.S.brackets complete with fittings such as syphonic arrangement, 15mm nominal size Brass/PVC ball valve with polythene float, CP/Brass handle, unions and couplings for connection with inlet, outlet, overflow pipes, 32mm dia PVC flush bend, 15mm dia PVC connection pipes including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting inlet pipe with supply main with etc all complete as per specification and direction of the E.I.C10 lit PVC L/L Cistern
186Supplying all materials, labour, T&P and fixing bowl pattern urinal(Hindware,Parryware,Cera) including connecting the urinal with waste pipeby means of white lead mixed with chopped hemp etc all complete as per specification and direction of the E.I.C.Half stall urinal
187Supplying all materials,labour, T&P and providing marble slab in urinal partition wall including cutting grooves in wall and making good the damages including watering curing etc as per specification and direction of the E.I.C2 x 0.60m x 0.90m = 1.08 sqm
188Earthwork in all kinds of soil in excavation of foundation trenches within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth etc all complete as per direction of the E.I.C.1x50x0.45x0.45m=10.125
189Supplying all materials, labour ,T&P and laying in trenches HDPE of the following nominal bore and pipe fittings including testing etc all complete as per direction of the E.I.C. 32mm dia HDPE pipes
190Supplying and fitting & fixing of I.S.I make 1.00 H.P single phase Submersible Pump set to give discharge of 3000 ltr/hour at a head of 40 mtr etc all complete as direction of EIC.
191Supplying all labour,T&P and fitting & fixing of I.S.I make 1.00 H.P single phase Submersible Pump set with commissioning and testing etc all complete as direction of EIC.
192Supplying and fitting & fixing of D.O.L starter for1.0 H.P single phase Submersible Pump etc all complete as per direction of Engineer-in-charge.
193Supplying and fitting & fixing of suitable cable and connecting the pump and starter etc all complete as per direction of Engineer-in-charge.
194Supplying and fitting & fixing of Plastic rope, M.S well cover, M.S clamp, etc all complete as per direction of Engineer-in-charge.
195Supplying and fitting & fixing of HDPE pipes and pipe fittings with C.P Nippling and lowering to bore well, making connection to pumpset & testing etc all complete as per specification and the direction of the E.I.C.32 mm dia HDPE Pipe
196Supplying all materials, labour, T&P and constructing Bore Protection Chamber of the following sizes with cement concrete (1:3:6) using 40 mm size HG metal on bed, 1st class KB Brick work in CM (1:6) moulding and shaping the channel inside and benching with C:C (1:1.5:3) using 12 mm size H.G chips, 12 mm thick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in C.C(1:1.5:3) using 12 mm size H.G chips with RCC man hole cover, earth work excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per approved specification and direction of E.I.CInside size 760mm x 760mm x 460mm
197BORE WELL (200MM X 150 MM DIA)Labour for drilling a perfectly vertical bore hole at specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rigs or combination rigs as required to suit the site condition as per the direction of the Engineer-in-charge including use of own rigs with its accessories, tools and plants and consumables etc for lowering of 200 mm dia P.V.C/G.I/MS pipes for housing fitted socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/P.V.C/M.S casing pipes if required to prevent collapse of over burden is to be provided by the contractor including lowering and withdrawing after completion of the tubewell)Drilling of 200mm dia bore :-00 mtr to 30.00 mtr
198Drilling of 150mm dia bore :-30.01 mtr to 80.00 mtr
199Lowering of the following size G.I/P.V.C pipes with or without slotted pipes as per the necessary from ground level upto 30 mtrs depth and fitted and fixed up in perfectly vertical position including cutting and threading pipes and slotted pipe and supplying and fixing all jointing materials, tools and plants complete and keeping the top of the casing pipe threaded including plugging tubewell to prevent entry of foreign materials from above. Lowering of 200 mm dia PVC pipes :- 00mtr to 30.00 mtr
200Cost of 200 mm dia PVC pipes :- 00mtr to 30.30 mtr
201Cleaning and developing the tube well using their own compressor continuously worked till clean and adequate discharge is obtained from the tubewell including supply and use of all necessary equipments and labour as per the direction of Engineer-in-charge.
202Sinking of T.W (125mm x 100mm dia)Labour for drilling a perfectly vertical bore hole at specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rigs or combination rigs as required to suit the site condition as per the direction of the Engineer-in-charge including use of own rigs with its accessories, tools and plants and consumables etc for lowering of 200 mm dia P.V.C/G.I/MS pipes for housing fitted socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/P.V.C/M.S casing pipes if required to prevent collapse of over burden is to be provided by the contractor including lowering and withdrawing after completion of the tubewell)Drilling of 125mm dia bore :-00 mtr to 30.00 mtr
203Drilling of 100mm dia bore :-30.01 mtr to 80.00 mtr
204Lowering of the following size G.I/P.V.C pipes with or without slotted pipes as per the necessary from ground level upto 30 mtrs depth and fitted and fixed up in perfectly vertical position including cutting and threading pipes and slotted pipe and supplying and fixing all jointing materials, tools and plants complete and keeping the top of the casing pipe threaded including plugging tubewell to prevent entry of foreign materials from above. Lowering of 125 mm dia PVC pipes :- 00mtr to 30.00 mtr
205Cost of 125 mm dia PVC pipes :- 00mtr to 30.30 mtr
206Cleaning and developing the tube well using their own compressor continuously worked till clean and adequate discharge is obtained from the tubewell including supply and use of all necessary equipments and labour as per the direction of Engineer-in-charge.
207Supplying, all materials, labour, T&P and providing and fixing ISI marked Deep Well Hand Pump Standard HWDP conforming to IS-15500/04 Part-II complete with accessories alongwith 8 nos of connecting rod made of bright bar electro galvanized of 12mm dia of 3 mtr long with coupler and fitted with stand assembly including fitting and fixing and lowering of Hand Pump set at the Tube well with necessary length of riser pipes including carriage and conveyance of all materials and T&P etc all complete as direction of E.I.C.
208Supplying all materials, labour, T&P and constructing tubewell Platform as per UNICEF design with drain and specification with C.C (1:2:4)using 12 mm size C.B H.G chips embedding pedestal base concrete of 76x76x40cm size, outer and inner diaplatform 1.85m and 1.65 m respectively with 0.10m, height walling, footrest size1.0mx1.0m including earthwork in all kinds of soil, centering and shuttering, laying concrete, plastering and punning, watering and curing finished smooth including cost, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per approved specification and direction of the E.I.C.1.85 m dia tubewell platform Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58602651
AUTHORITY Government Departments
TENDER VALUE 1.92 Crore
LAST DATE 04-12-2026
Authority
Authority Name Rural Works Department
Work Description Tender for Construction Of 24X7 Phc Building At Mandibisi Of Kashipur In The District Of Rayagada For The Year 2025-2026.
Basic Detail
Tender No NCB 17 RWC RGDA 2026 27
Bidding Type Tender
Location
City Rayagada
State Odisha
Key Dates
Publish Date 18 Nov 2026
Submission Date 04 Dec 2026
Open Date 05 Dec 2026
Finance
Tender Value 1.92 Crore
Tender Fee 10000
EMD 1.92 Lakhs
Exemption Available
Document List
77a222fd-b7a8-48f2-8c60-57fbb7b9db10.html
BOQ_622105.xls
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Dec 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

77a222fd-b7a8-48f2-8c60-57fbb7b9db10.html

xls

BOQ_622105.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf