Tender For Construction Of Assistant Labour Officer Building At R.Udayagiri Block In The District Of Gajapati For The Year 2026-27
Tender Value
1.72 Crore
Estimated cost
Bid Submission
04 Dec 2026
12 days left
EMD
1.72 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gajapati → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Assistant Labour Officer Building At R.Udayagiri Block In The District Of Gajapati For The Year 2026-27
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORKDiluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment) including cost of all materials, labour, T&P etc complete in all respect and as per direction of the Engineer-in-charge.Ground Floor |
| 2 | Watchman Shed |
| 3 | Earth work in excavation of foundation trenches in hard soil including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site within 50m initial lead & 1.5m initial lifts with sundries & T&P required for the work complete including cost of all labour,labour cess,T&P,sundries etc. as directed by the Engineer in charge.Ground Floor |
| 4 | Compound wall |
| 5 | Watchman Shed |
| 6 | Supplying and filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-chargeGround Floor |
| 7 | Compound wall |
| 8 | Watchman Shed |
| 9 | Cement Concrete (1:3:6) using 40mm size hard granite C.B. metal approved quality from approved quarry including cost, carriage, royalty, cost of all labour. etc complete and as directed by E.I.C.Ground Floor |
| 10 | Compound wall |
| 11 | Watchman Shed |
| 12 | Plain cement concrete (1:2:4) using 12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concrete in layers, watering, curing etc. complete including cost, conveyance, royalties and taxes of all materials with labour,labour cess and T&P etc. required for the work complete as per the direction of the Engineer-in-charge.Ground Floor |
| 13 | Compound wall |
| 14 | Watchman Shed |
| 15 | Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, and royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-ChargeGround Floor |
| 16 | Compound wall |
| 17 | Watchman Shed |
| 18 | Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.Ground Floor |
| 19 | First Floor |
| 20 | Head Room |
| 21 | Compound wall |
| 22 | Watchman Shed |
| 23 | Fly Ash brick masonry in cement mortar (1:4) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.Ground Floor |
| 24 | First Floor |
| 25 | Watchman Shed |
| 26 | R.C.C. M-25 grade with 20mm and down grade C.B. chips of approved quality from approved quarry including hoisting, laying hire charges of concrete mixture, vibrator, watering, curing and cost of all materials and labour, centering shuttering etc complete but excluding cost of reinforcement.Ground FloorFooting |
| 27 | Column |
| 28 | Plinth Beam |
| 29 | Lintel |
| 30 | Roof Beam |
| 31 | Roof Slab |
| 32 | Chajja |
| 33 | StairCase |
| 34 | Shelves |
| 35 | First FloorColumn |
| 36 | Lintel |
| 37 | Roof Beam |
| 38 | Roof Slab |
| 39 | Chajja |
| 40 | StairCase |
| 41 | Head RoomColumn |
| 42 | Chajja |
| 43 | Roof Slab |
| 44 | Watchman ShedFooting |
| 45 | Column |
| 46 | Plinth Beam |
| 47 | Lintel |
| 48 | Roof Beam |
| 49 | Roof Slab |
| 50 | Chajja |
| 51 | Shelves |
| 52 | Compound wallFooting |
| 53 | Column |
| 54 | Plinth Beam |
| 55 | Roof Beam |
| 56 | Providing 25 mm thick grading concrete (1:2:2) on roof slab with 6.7mm & down grades size hard granite crusher broken chips using 2% water proofing cement compound (Make -sika/fosroc/Equivalent) on new workGround Floor |
| 57 | First Floor |
| 58 | Head Room |
| 59 | Watchman Shed |
| 60 | Straightening, cutting, bending bent up or coiled rods, including cranking, hooking, welding or jointing the M.S. rods or tor confirming to I.S. 432 (Plain) and 1785 (Tor) steel and binding, tying the grills, hoisting, lowering and placing in proper position required for R.C.C. works including cost, conveyance and taxes of M.S. rods or tor steel and binding wires of 18 to 20 gauge and cost of all labour etc.complete in all respect.Ground Floor |
| 61 | First Floor |
| 62 | Head Room |
| 63 | Compound wall |
| 64 | Watchman Shed |
| 65 | 12mm thick C.P.(1:6) on brick masonary to the smooth surface including watering, curing, cost, carriage, royalty of all materials, cost of all labour, etc complete as per the direction of E.I.C.Ground Floor |
| 66 | First Floor |
| 67 | Head Room |
| 68 | Compound wall |
| 69 | Watchman Shed |
| 70 | 16mm thick C.P. (1:6) over brick masonary to the smooth surface including watering, curing cost, carriage, royalty, and taxes of all materials, cost of all labour, etc complete as per the direction of E.I.C.Ground Floor |
| 71 | First Floor |
| 72 | Head Room |
| 73 | Watchman Shed |
| 74 | 6 mm thick cement plaster (1:4) to RCC surfaces finished smooth including closed deep chiping and slury treatment including watering, curing cost, carriage, royalty of all materials, cost of all labour, etc complete as per the direction of E.I.C.Ground Floor |
| 75 | First Floor |
| 76 | Head Room |
| 77 | Watchman Shed |
| 78 | Supplying, fitting and fixing Vitrified tile in floors of approved make confirmating to IS:13755 laid on 20 mm thick cement mortar (1:4) and filling joints with white cement of approved quality including cost of all materials, etc. required for the work all complete as per direction of E.I.C. Ground Floor |
| 79 | First Floor |
| 80 | Watchman Shed |
| 81 | Fixing Vitrified tiles in dados skirting and risers of steps on 12mm thick CP (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including cost, carriage, cost of all labour etc. complete.Ground Floor |
| 82 | First Floor |
| 83 | Watchman Shed |
| 84 | Supplying, fitting & fixing of Granite Tiles of minimum Above 0.40 sqm. (20mm thick) of approved make in floors laid on 20 mm thick cement mortar (1:4) and filling joints with slurry including cost of all materials, labour T&P etc. required for the work all complete incl. rubbing as per direction of the Engineer-in-chargeGround floor |
| 85 | First Floor |
| 86 | Watchman Shed |
| 87 | Supplying, fitting & fixing of Chequered tiles in floors of approved make laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with slurry including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge Ground Floor |
| 88 | Finishing surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials labour T & P etc. as per direction of Engineer -In -chargeGround Floor |
| 89 | First Floor |
| 90 | Watchman Shed |
| 91 | Priming 1 coat with wall primer water bond cement primer including all labour, materials etc. complete. Ground Floor |
| 92 | First FloorExternal Wall |
| 93 | Internal Wall |
| 94 | Head RoomExternal Wall |
| 95 | Internal Wall |
| 96 | Watchman Shed |
| 97 | Compound wall |
| 98 | Wall Painting two coats with approved Plastic Emulsion Paint including all labour, materials etc. complete.Ground Floor |
| 99 | First Floor |
| 100 | Head Room |
| 101 | Watchman Shed |
| 102 | Wall painting two coat with any approved weather coat paint including cost of all materials, labour and T&P require for the work etc. complete as directed by the E.I.C. Ground Floor |
| 103 | First Floor |
| 104 | Head Room |
| 105 | Watchman Shed |
| 106 | Compound wall |
| 107 | Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, taxes, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-ChargeGround floor |
| 108 | First Floor |
| 109 | Head Room |
| 110 | Watchman Shed |
| 111 | Compound wall |
| 112 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance of all materials, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. Ground Floor |
| 113 | First Floor |
| 114 | Priming one coat with any approved primmer (To Receive Enamel paint) including cost of primer & labour to give an even shade etc. complete.Ground Floor |
| 115 | First Floor |
| 116 | Head Room |
| 117 | Watchman Shed |
| 118 | Compound wall |
| 119 | Painting two coats with approved enamel paints of approved colour, shade including sand papering, polishing the surface, cost, conveyances of all materials and cost of all labour etc, complete as per specification & direction of E.I.C.Ground Floor |
| 120 | First Floor |
| 121 | Head Room |
| 122 | Watchman Shed |
| 123 | Compound wall |
| 124 | Supplying, fiting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fitting and fixture etc. complete Ground Floor |
| 125 | First Floor |
| 126 | Watchman Shed |
| 127 | Dressed seasoned sal wood work framed and fixed (wrought and put up) in frames of doors, windows & ventilabours Ground Floor |
| 128 | First Floor |
| 129 | Watchman Shed |
| 130 | Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride (UPVC) ( FENESTA / NCL VEKA LTD.) Ventilator/ Top Hung-60-Series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mmx2.5 mm for outer frames, 75 mm x 60 mm x 2.25 mm for casement Window Sash Profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges, materials and product conforming to ASTM D 638-14,EN-477-95 and other applicable codes and standards.Ground Floor |
| 131 | First Floor |
| 132 | Watchman Shed |
| 133 | Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.Ground Floor |
| 134 | First Floor |
| 135 | Watchman Shed |
| 136 | Supplying , fitting and fixing of grid mineral fibre ceiling board having size 600 mm x 600 mm x 16mm of approved design and quality complete with frame and all fitting and fixtures.Ground Floor |
| 137 | First Floor |
| 138 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 5000 m as per Technical Specification Clause 301.5 and as per the direction of EIC.Ground Floor |
| 139 | Construction of Granular Sub-base by providing coarsed graded materials,spreading in uniform layer by mortar grader on prepared surface mixing by mix in place method with rotavator at OMC and compacting with vibratory roller to achieve the density, complete as per Clause - 401. |
| 140 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with pave (AR, P-166/42) |
| 141 | Supplying and fixing of Pre cast kerb stone of size 300mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984. |
| 142 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP - 63:2018. |
| 143 | P.H Works:-Supplying all materials,labour,T&P and fitting & fixing of 4.0kgf/cm2 U-PVC soil waste ventilating pipes and fitting of the following O.D conforming to ISI No. 13592/1992 to walls with nails bobbins and wooden plugs or earth work in excavation in all kinds of soil for laying in trenche including jointing with supply of approved rubber lubricant by non-heat application method as per manufactures specification including tasting and refilling and trenches as per direction of E.I.C.110mm dia PVC pipe |
| 144 | 110mm dia PVC Pair P trap |
| 145 | 110mm dia Pair Nahani Trap |
| 146 | 110mm dia PVC S/J/D |
| 147 | 110mm dia PVC Door Tee |
| 148 | 110mm dia PVC D/J/D |
| 149 | 110mm dia PVC Door Bend |
| 150 | 110mm dia PVC Plain bend |
| 151 | 110mm dia PVC offset |
| 152 | 110mm dia PVC cowl |
| 153 | 125mm dia CP Grating |
| 154 | Supplying all materials,labour,T&P and cutting holes through brick/stone masonry walls for taking PVC pipes and fittings including making good the damages etc all complete as per the PH specification and direction of E.I.C.375mm thick wall |
| 155 | 250mm thick wall |
| 156 | Roof cutting |
| 157 | Supplying all materials labour T&P and fixing wash down water closet(Anglo Indian water closet)with integral S or P trap to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cm(1:1) etc. all complete as per specification and direction of E.I.C. EWC with S inch Trap with sheet cover(make-Parryware,Hindware) |
| 158 | Supplying & fixing of Matrix Set-1 (WB 46X36 with one pair mounting brackets, EWC & cistern complete with fittings & seat cover, one no hinged rail 76 cm and 4 nos of grab rail 60cm complete with all as per specification & direction of the Engineer in charge. |
| 159 | Supplying all materials,labour,T&P and fixing Wall Mounted Grab Bar including all complete as per specification and direction of the E.I.C. Wall Mounted Grab Bar 600m long |
| 160 | Supplying all materials,labour,T&P and fixing wash basin with hole for pillar taps with CI/MS brackets painted white including holes in walls and making good the damages etc.all complete as per PH specification and direction of E.I.C. (a)550mmx400mm WHB with 32mm dia cp west,west pipe,brackets and connection pipe(make- parryware) |
| 161 | Pedestrial for basin(make- parryware) |
| 162 | Supplying all materials,labour T&P and fixing mirror of superior glass mounted on 6mm thick AC sheet or plywood sheet and fixing to wooden plugs with CP screws and washers complete as per PH specification and direction of E.I.C.Glass mirror 600mmx450mm size(fixed type) |
| 163 | Supplying all materials,labour T&P and fixing standard size glass shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per PH specification and direction of E.I.C.450mmx125mm size plate Acrylic shelf |
| 164 | Supplying all materials,labour T&P and fixing standard size CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per PH specification and direction of E.I.C.CP towel ring(make -Parryware) |
| 165 | Supplying all materials, labour, T&P and fixing standard sized Soap Dispensor of Hindware/Jaquar/Parryware complete with all as per specification and direction of the Engineer in charge. Soap dispense with Glass Bottle. |
| 166 | Supplying all materials,labour T&P and fixing standard size CP soap holder complete with CP Brass brackets fixed to wooden plug with CP screws as per P.H. specification and direction of E.I.C. |
| 167 | CP Double coat hook |
| 168 | Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink with C.I/M.S brackets paintedwhite including holes in walls and making good the damages etc all complete as per specification and direction of the E.I.C.600x450x200 mm stainless steel kitchen sink (Mousumi make) 40mm dia CP waste ,pvc waste pipe |
| 169 | Supplying all materials labour T&P and fixing Ciramic tiles/marble tiles/kota tiles/ kodapa tiles/chequered tiles in floors,threads,landing on 25mm thick bed of cm(1:1)jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing & polishing complete including cost of precast tiles etc. all complete as per specification and directiof E.I.C. In GF |
| 170 | In FF |
| 171 | Supplying all materials labour T&P and fixing porcelain glazed tiles/marble tiles/ Kota tiles/Kodapa tiles in dados skirting and risers of steps on 12mm thick CP(1:3)jointed with neat cement slurry mixed with pigments to match the shade of tiles including rubbing & polishing complete including cost of tiles etc. all complete as per spcificaiton and direction of E.I.C.In GF |
| 172 | In FF |
| 173 | Providing fitting fixing Al door with anodized Al door section of 9202 as vertical member,9201 as top,9200 as bottom and middle member with frame section as 9221with tapered clip no 4660 & frame to be completed by means of jointing angle no 1855 including cost of labour T&P hire charges of drilling machine labour charges etc complete with cost of laminated board.and as per direction of the E.I.C. |
| 174 | Earth work in all kinds of soil in excavation of foundation trenches within 50m initial lead including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth as per direction of E.I.C.Initial lift upto 1.50m |
| 175 | From 1.50m to 3.00m depth |
| 176 | Supplying all materials labour T&P and filling foundation & plinth with river sand well watered and rammed including conveyance of all materials to work site, payment of royality,taxes etc. all complete as per the direction of E.I.C. |
| 177 | Supplying all materials labour T&P and providing cc(1:3:6)using 4cm hg metal including watering,curing,conveyance of all materials to work site,payment of royality,taxes etc.all complete as per specification and direction of E.I.C. |
| 178 | Supplying all materials labour T&P and providing cc(1:1.5:3)using 12mm hg chips including watering,curing,conveyance of all materials to worksite,payment of royality,taxes etc. all complete as per specification and direction of E.I.C. |
| 179 | Supplying all materials labour T&P and providing Flyash brickwork in cm(1:4) F&P having crushing strength not less than 75kg/cm2 with dimensional tolerance +/-8%including watering,curing conveyance all material to worksite payment of royality taxes etc.all complete as per specification direction of E.I.C. |
| 180 | Supplying all materials labour T&P and providing rigid and smooth centering & shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite,payment of royality, taxes etc. all complete as per specification and direction of E.I.C. |
| 181 | Supplying all materials labour T&P and providing MS reinforcement for RCC works including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge conveyance of all materials to worksite,payment of royality,taxes etc. all complete as per specification and direction of E.I.C. |
| 182 | Supplying all materials labour T&P and providing RCC(1:1.5:3)using 12mm hg chips for RCC works including hoisting,laying,watering,curing,conveyance of all materials to work site,payment of royality,taxes etc. all complete as per specification and direction of E.I.C. |
| 183 | Supplying all materials,labour T&P and providing 12mm thicks CP(1:3)with punning on brick/stone work including watering,curing conveyance of all materials to work site,payment of royality,taxes etc. all complete as per specification and direction of E.I.C. |
| 184 | Supplying all materials labour T&P and fixing MS step iron in 12mm dia MS steel bar and fixing into walls of septic tank duly embedded in cc(1:3:6)all complete as per PH specification and direction E.I.C. |
| 185 | Supplying all materials labour T&P and fixing of RCC baffle wall precast with cc(1:1.5:3)using 12mm bhg chips and fitted to septic tank as per P.H. specification and direction E.I.C. |
| 186 | Supplying all materials,labour,T&P and providing fitting&fixing PVC Tee in wall including fitting the necessary with cc(1:1.5:3)with 12mm size hg chips all complete including watering,curing,conveyance of all materials to worksite, payment of royality,taxes etc. all complete as per specification and direction of E.I.C.(a)110mmx110mmx110mm PVC Tee |
| 187 | Supplying all materials labour T&P and Providing cement flush pointing(1:3)to brick masonary including watering,curing,conveyance of all materials to work site etc. all complete as per specification and direction of E.I.C. |
| 188 | Supplying all materials labour T&P and providing 500x500x100mm thick RCC precast MH cover in cc(1:1.5:3)using 12mm hg chips placing the cover on the MH/S tank & finishing smooth all complete as per specification and direction of E.I.C. |
| 189 | Filling in F&P with excavated materials including watering and ramming as per direction of E.I.C. |
| 190 | Supplying all materials labour T&P and constructing inspection chamber of the following sizes with cc(1:3:6)using 40mm size hg metal on bed,1st class KB brickwork in cm(1:6)moulding&shaping the channel inside&benching with cc(1: 1.5:3)using 12mm size hg chips,12mm thick CP(1:3)with punning to inside, cement flush pointing(1:3)to outside,RCC cover slab in cc(1:1.5:3)using 12mm size hg chips with RCC manhole cover,e.w in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,conveyance of all materials to site,payment of royality,taxes etc. all complete as per approved specification and direction of E.I.C.Inside size 760mmx760mmx460mm |
| 191 | Supplying all materials labour T&P and laying PVC pipe sewer line Grade-A of the following internal dia in trenches(to level or slope)and jointing with gasket & stiff mixture or cm(1:1),cc(1:3:6)with 40mm size hg metal on bed of the trench and hunching or allround concrete encasing with cc(1:4:8)using 40mm size hg metal including curing,conveyance to worksite,payment of royality,taxes etc and testing all complete as per approved drawing,specification and direction of E.I.C.110mm dia PVC pipe with allround Hunch top |
| 192 | Supplying all labour T&P and constructing soakwaypit of the following sizes with dry brick walling from bottom upto invert of inlet pipe & 1st class KB brick work in cm(1:6)for the remaining height at top,12mm thick CP(1:4)inside & outside over masonary brickwork,gravel packing in the rear of well steining RCC coverslab in cc(1:1.5:3)using 12mm size hg chips fitted handles including ew in open well excavation in all kinds of soil and refilling the cavity around the pit & painting the iron work,watering,curing,conveyance of all meterails to worksite,payment of royality,taxes etc. all complete as per approved drawing specification and direction of E.I.C.20m dia x 2.00m deep |
| 193 | Supplying all materials, labour, T&P and constructing Leach pit of the following size with 1st class KB brick work in CM (1:4), 12mm thick Cement Plaster (1:4) inside and outside over masonry brick work upto 0.60 mtr deep, RCC cover slab in CC (1:1.5:3) using 12mm HG chips, including earthwork in open well escavation in all kinds of soil and refilling of cavity around the pit, watering, curing, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per approved specification and direction of the E.I.C.0.60m dia and 1.00 m deep circular Leach pit |
| 194 | W/S SUPPLY PORTION:-Supplying all materials,labour,T&P and Fitting&Fixing of Rotational moulded polythene cylindrical vertical water storage tank conforming to 12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jamnuts, including hoisting upto a height of 5mtr above GL and placing the tank in required position including conveyance of all materials to work site,payment of royalty,taxes etc all complete as per P.H specification and direction of the E.I.C.(a)2000ltr water storage tank(1st Floor) |
| 195 | Supplying all materials,labour,T&P and Fitting&Fixing of Rotational moulded polythene cylindrical vertical water storage tank conforming to 12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jamnuts, including hoisting upto a height of 5mtr above GL and placing the tank in required position including conveyance of all materials to work site,payment of royalty,taxes etc all complete as per P.H specification and direction of the E.I.C.(a)2000ltr water storage tank(1st Floor) |
| 196 | Supplying all materials,labour,T&P and fitting&fixing 10ltr capacity low level flushing cystern with a pair of cast iron or ms brackets complete with fittings such as syphonic arrangements 15mm nominal size brass/PVC ball valve with polythene float,CP brass handle,union and couplings for connection with inlet, outlet and overflow pipes,32mm dia c.p. flush bend,15mm dia. PVC inlet connection pipe including cutting holes and making good the same and connecting the flushbend with cystern and closet and connecting inlet pipe with supply main etc. all connecting inlet pipe with supply main etc. all complete as per specification and direction of E.I.C. 10Ltr.Capacity low level cistern |
| 197 | Supplying all materials,labour,T&P providing and fixing to wall or ceiling and floor PVC pipe conforming to ASTM-D-1785/89(sch-80) and pipe fitting of the following nominal bore with clamps including making good the wall,ceiling and floor testing all complete as per specification and direction of E.I.C.40mm dia C-PVC pipe |
| 198 | 32mm dia C-PVC pipe |
| 199 | 25mm dia C-PVC pipe |
| 200 | 20mm dia C-PVC pipe |
| 201 | Supplying all materials,labour,T&P cutting holes through brick/stone masonry works including making good the damages in cm(1:4)for taking GI/PVC pipe & fitting etc. all complete as per PH specification and direction of E.I.C.In GF |
| 202 | In FF |
| 203 | Supplying all materials,labour,T&P cutting holes in RCC floors,roofs etc.up to 19cm thick for passing GI/PVC pipes fittings and reparing the holes after insertion of pipe etc. with cc(1:1.5:3)including finishing so as to make it leak proof as per direction of E.I.C. |
| 204 | Supplying all materials,labour,T&P and cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per direction of E.I.C.In GF |
| 205 | In FF |
| 206 | Supplying all materials,labour,T&P and fitting & brass/CP fittings of the following nominal bore with supply of all jointing materials etc. complete as per P.H. specification and direction of E.I.C.(make-Jaguar)15mm dia CP(SB)Bib cock |
| 207 | 15mm dia CP Two way Bib cock |
| 208 | 15mm dia CP Pillar cock swan neck |
| 209 | 15mm dia CP Angle Stop cock |
| 210 | 15mm dia CP Concealed Stop cock |
| 211 | 15mm dia Health Faucet & 1.0m long Flexible pipe |
| 212 | 25mm dia PVC FWV |
| 213 | 15mm dia CP Flange |
| 214 | 15mm dia CP Extension piece |
| 215 | Provision for Aquaguard hot and cold RO + UU water puirifier Cooler PC1530SS plain & cold water 15 lter capacity with Traspotation charges. |
| 216 | 1.00HP Single Phase Submersible Pump Set:-Supplying of ISI mark 1.00HP single phase vertical submersible pump set with discharge of 900-1000ltr/hour and a head of 55-70m of reputed make like KSB/ Texmo & equivalent including all cost,conveyance and taxes etc all complete as per direction of E.I.C. |
| 217 | Supplying all labour,T&P and fitting and fixing of 1.00HP single phase vetrical submersible pump set with commissioning and testing etc.all complete as per direction of E.I.C. |
| 218 | Supplying fitting & fixing of ISI mark DOL starter of reputed make like BCH or equivalent for 1.00HP single phase submersible pump including all cost, conveyance of all taxes etc all complete as per direction of the E.I.C. |
| 219 | Supplying all materials labour T&Pand fitting & fixing of 2.5mm2 3core copper flat suitable cable having ISI mark of reputed company like BCH/Finolex or equivalent & connecting the pump starter including cost conveyance & taxes etc. all completes as per P.H. Specification and direction of E.I.C. |
| 220 | Supplying fitting and fixing of plastic rope MS Well cover,MS Clamp,Stainless steel short piece,bend & socket including all cost,taxes etc all complete as per direction of the E.I.C. |
| 221 | Supplying fitting and fixing of HDPE Pipes & pipe fittings with making connection to pump set including all cost conveyance and taxes etc all complete as per direction of the E.I.C. |
| 222 | 200mmx150mm Size Bore WellL Through DTH MethodLabour for drilling of perfactly vertical bore holes as specified dia.For a specified depth below GL through consolidated & uncosolidated rock with down the hole hammer drilling rigs or combination drilling rigs(600cfm/200psi) as required to suit the site conditions as per the direction of E.I.C.including use of own rigs with its accessories,tools & plants and consumable etc. for lowering 200mm dia PVC/GI pipes for house fitted with socket and with or without well screen as per the necessity for the soft,medium,hard & boulder formation(PCV/GI)casing pipes if required to prevent collapse of over burden is to be provided by the contractor including lowering and with drawing after complete of tube well.(Tube well-1No)Drilling of 200mm. dia. Bore-0.00mtr to 44.40mtr |
| 223 | Drilling 150mm dia. Bore-44.40mtr to 200.00mtr |
| 224 | Lowering the following GI/PVC pipe with or without soltted pipes as per necessity from GL upto 30.00mtr depth and fitted and fixed in perfecty vertical position including cutting and threading pipes and soltted pipes and supplying and fixing of all jointing materials,T&P etc the top of the casing pipe threaded including piping tubewell to prevent entry of foreign materials from above(PVC/ GI)supplied by the contractor(including cost of pipe)Lowring of 200mm dia pipes-0.00mtr to 44.40mtr |
| 225 | Cost of 200mm dia PVC casing pipes-0.00m to 45.00m |
| 226 | Cleaning & developing the tube well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per the direction of E.I.C. |
| 227 | ELECTRICAL WORK :-Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/Vguard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.GROUP-A |
| 228 | GROUP-B |
| 229 | GROUP-C |
| 230 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 231 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 232 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 233 | Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/-Schneider(Zencelo)/PANASONIC(VISION) |
| 234 | Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius-NEXT GEN)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 235 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 236 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI V Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 237 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEIV Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 238 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 nos of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit.(2X6+1X2.5) |
| 239 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 2.5 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(4X6+2X2.5) |
| 240 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 1 nos single core 2.5 sq. mm copper wire for Inverter Wiring. |
| 241 | Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 year against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 242 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 243 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 244 | Sub-Head II (Light fitting Fixture & Fan)Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 245 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery greater than or equal to 215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(With fan Regulator) |
| 246 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 247 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 248 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 249 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 250 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 251 | Supplying and fixing 32 amps, 240 volts, SPN, industrial type socket outlet, with 2 pole+E-DP plug & socket DB with 32A DP MCB,C series,10ka as per IEC-61439-3 ,suitable for flush & surface mounting,supplied with neutral link with provission for mounting modular devices as per direction of Engg.-in-Charge. Make-Legrand/ Siemens/Schneider/ABB |
| 252 | BDBS,DB,AC DB,FLOOR PANELS,MCBSSupplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years. |
| 253 | Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years . |
| 254 | Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 240 volts, MCB . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 years.. |
| 255 | Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 415 volts, RCCB 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year |
| 256 | Supplying and fixing 63Amps 4P 415 volts MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on MCB is 1 years. |
| 257 | (Earthing) INSTALLATIONSupplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 258 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 259 | Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 260 | CABLING AND END TERMINATION MAIN AREASupplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5core x 35 sq mm |
| 261 | 4core x 16 sq mm |
| 262 | LAYING OF CABLELaying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 263 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 264 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 265 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 266 | Supplying and making end termination with double brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5 core x35 sq mm |
| 267 | 4 core x16sq mm |
| 268 | Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 50 mm dia |
| 269 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 200 mm dia |
| 270 | PANELS MAIN CONTROL PANEL AT GF S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) )as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 years & compelete test certificate must be submitted along with panel board including component list.50x10mm Separate Aluminium Earth bus bar should be installed.All the feeders shall have ON/OFF/TRIP indication. |
| 271 | 25 KVA DGSupply, Transportation, erection, testing and commissioning of 3 Phase, 415V, 50Hz, water cooled multi cylinder diesel generator set with alternator of prime rated 25KVA ( Make -Kirloskar / Jakson/Mahindra/TMTL/CAPTIVA/Sterling) out put contineous rating directly coupled Engine and Alternator with guard and mounted on a common base plate of Robust construction and complete with AMF panel having IP-52 protection, Acoustic Enclosure as per CPCB IV+ norms , sound absorbing material, to restrict sound level up to 75 dB up to 1 mtr distance and as per CPCB IV+ norms etc as per following specifications mentioned below. Warrentee period must be 2 years FOUNDATION: Suitable size Cement Concrete (1:2:4) foundation duly plastered and finished with neat coat Cement as required along with smoke exhaust system piping including base frame of structure & lightening protection system. *It also includes control cable of 15mtr 2.5sqmm 6core , civil foundation work. (The Manufacturing of DG set shall not in any case be more than six months old from the date of award of work) |
| 272 | FIRE FIGHTINGPUMPS AND APPURTENANCESSupplying, installation, testing and commissioning of Electric Motor Driven Pressurization Terrace Pump having discharge of 450 LPM at 35 Mtr head complete with Pump Set, Electric Motor suitable for operation on 415 V ,3 ph, 50 c/s AC supply , Base Frame.Make-Wilo/KSB/Kirloskar/Grundfoss |
| 273 | Supply, installation, testing and commissioning of Floor/Wall mounted sectionalised, front operated top entry dust and vermin proof M.V.Panel Boards suitable for operation at 415V, 3 phase, 4 wire, 50Hz distribution system fabricated out of 2.0 mm thick CRCA sheet, insulated busbar with heat shrienkable PVC sleeve, base frame, complete with all accessories including interconnections, earth bus etc as required comprising of One (1)- 63 Amp, 10 KA,TPN (Class-C) MCB with 3 Nos Phase indicating lamps with control fuse/ MCB, Digital Voltmeter with selector switch. DOL starter with O/L and Single Phasing Preventor suitable for 7.5 HP motor. ON/OFF indication lamps, Auto manual switch and ON/OFF push button.as per direction of engineer in charge Control panel for fire pumps for auto action.make-Legrand/schneider/Siemens/eq. Model of ABB/L&T/Hager/C&S/Havells |
| 274 | 1100 V GRADE POWER/CONTROL CABLES :SITC of FRLS,PVC outer sheateh, steel armoured, aluminium, 1100v grade power cables with glands etc. The minimum size of the cables shall as mentioned below as per direction of engineer in charge.Make-Polycab/Havels/KEIRR KABEL/FINOLEX/GLOSTER 3.5C x 16 mmsq |
| 275 | 2 C x 1.5 mmsq |
| 276 | PIPE & VALVES ETC.Supply,Installation,Testing & Commissioning of 'C' Class heavy duty MS pipe (as per IS 1239 upto 100 mm NB and IS 3589 for above 100 mm 6.33mm thick) with flanges and fitting such as bends, tees, reducers, rubber insertions and galvanized nuts and bolts of following size on surface along wall / shaft with MS bracket, suspended from ceiling/ beam with suspenders duly painted with two coats of primer and finished with enamel paint of approved colour laid through pipe or in trench after wrapping with hassen cloth after applying coal tar primer as required as per direction of Engineer-in- charge.Make-TATA/SAIL/JINDAL100mm NB |
| 277 | 80mm NB |
| 278 | 25mm nb |
| 279 | Providing, fixing, testing and commissioning of following size manually operated hand lever type cast iron double flanged slim seal wafer type Butterfly valves with EPDM iron disc as per IS-13095 having pressure ratting PN -1.60 including fixing the same with supply of required jointing materials like rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of E.I.C. Make-Zoloto/AUDCO/Leader100mm NB |
| 280 | Providing, fitting & fixing of following size cast iron double flanged type dual plate Non return Valve as per IS- 5312 (Part 1): 2004 with ISI mark of pressure ratting PN-1.60 including fixing the same with supply of required jointing materials like flanges, rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of Engineer-in-charge. Make-Zoloto/AUDCO/Leader100mm NB |
| 281 | Supply,Installation,Testing & Commissioning of Pressure gauge of 0-16 Kgf/sq.cm. range with cut-off bronze ball valves of suitable size with all accessories as per direction of Engineer-in-charge.Make-H.Guru/G.Guru |
| 282 | Supply,Installation,Testing & Commissioning of Pressure Switch with cut-off bronze ball valves with integral strainer & flare nut (mixed ends) of suitable size with all accessories as per direction of Engineer-in-charge.Make-Danfoss/Indfoss/Grundfoss |
| 283 | Supply,Installation,Testing & Commissioning of stainless steel strainer fabricated out of 1.6 mm thick stainless steel sheet Y Stainer with 3 mm dia hloes with stainless steel flange as required. Make-Zoloto/AUDCO/Leader100mm NB |
| 284 | DOWN COMER SYSTEMSupply,Installation,Testing & Commissioning of Stainless steel Hydrant Valve / Landing valve, of 63 mm NB size, type-A, single headed , oblique type, as per IS :5290/93 and as per direction of Engineer-in-charge.Make-Newage/Minimax/Fireshield |
| 285 | Supply,Installation,Testing & Commissioning of SS short branch pipe with 63 mm male inlet and 19 mm outlet nozzle, as per IS:903 and as per direction of Engineer-in-charge. Make-Newage/Minimax/Fireshield |
| 286 | Supply,Installation,Testing & Commissioning of 63 mm NB and 15meter long RRL Fire Hose fitted with 63mm intstantaneous stainless steel male & female SS coupling, complete by GI wire binding for Internal Hydrant as per direction of Engineer-in-charge. Make-Newage/Minimax/Fireshield |
| 287 | Providing supply & fixing of MS Hose Box for of suitable size(750X600X250mm) to accomodate 2 nos. of 15/ 1 no of 30 mtr long fire hose and a branch pipe, wall mounted type as per direction of Engineer-in-charge. Make-Newage/Minimax/Fireshield |
| 288 | Supply,Installation,Testing & Commissioning of Swinging pattern wall fixing first aid hose reel made from MS sheet and waterways and moving parts with rubber hose of 20 mm dia. and 30 mtrs. long with ABS(Plastic) shut-off nozzle as per IS: 444/IS: 12585 Type-I., complete with all accessories as per direction of Engineer-in-charge. Make-Newage/Minimax/Fireshield |
| 289 | Providing, fitting and fixing of C.I. 25 MM single air relief valve with stop cock confirming to IS:14845/2000 with ISI mark for water works purpose including fixing the same with hydrant riser including testing & commissioning the system etc. all complete as per approved specification & direction of Engineer-in-charge. |
| 290 | Providing, fitting & fixing of 2-Way GM fire brigade connection consisting of 63 mm dia instantaneous type male couplings with built-in check valves, 150mm dia flanged outlet complete with bolts, nuts and rubber insertions confirming to IS:904 with ISI mark including testing & commissioning the system etc. all complete as per apporoved specification & direction of EIC. Make-Zoloto/Kirloskar |
| 291 | EXTINGUISHER SYSTEMSupply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,Carbon di-oxide type capacity 4.5kg with all accessories (Ever safe/Fire shield/Ceasefire/Safex/Flameklog) |
| 292 | Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,ABC type capacity 6kg with all accessories (Ever safe/Fire shield/Ceasefire/Safex/Flameklog) |
| 293 | Fire buckets (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter \\"FIRE\\" in black out side and handle with mounting bracket. |
| 294 | SIGNAGES:-Providing and installing in position the following type of sign boards made out of 3mm thick flexyle photoluminescent based glow in dark sheeting with luminous properties enclosed in a weather proof Uvstabilized film with UV screen printing by imported links pasted over3 mm thick cast acrylic from front side with 6 mm thick acrylic, -20 to+80 deg C, Suitablefor indoor use, greenish yellow, glow visible upto 4-6 hr in total darkness.Make-Prolite/Bajaj |
| 295 | Illumination Glow light for Exit Indication with Battery Back-up. |
| 296 | MANUAL FIRE DETECTION AND ALARM SYSTEMManual Fire AlarmSystem-:Supply, installation, testing and commissioning of Conventional type Main Fire Alarm Control Panel (FACP), the panel shall be conventional type fire detection and alarm system with capacity of 4 zone complete with all accessories and battery back up for 48 hours in standby mode and 15 minutes in alarm condition. The panel shall have minimum of 80 character display complete accessories.Make- System sensor by Honeywell/Ravel/Bosch. |
| 297 | Supplying, installing, testing and commissioning of conventional type Manual call point with all accessories complete. The device Make-System sensor by Honeywell/Ravel/Bosch. |
| 298 | Supplying, installing, testing and commissioning of conventional type Hooter at 85 dBA @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication with all accessories etc., complete. Make-System sensor byHoneywell/Ravel/Bosch.. |
| 299 | Supplying, installing, testing and commissioning of 2C x 1.5 sq. mm, Twisted Pair PVC insulated FRLS unarmored Cable with Accessories confirming to IS standards and specifications. The quoted rate shall includes of Acrylic Fire stop Sealant in the opening for cables passing through fire compartment walls of RCC floors, masonry walls to provide up to 2 hours fire rating. |
| 300 | 10 PASSENGER LIFT WITH WIRRING(1.1)Supply,Installation, Testing & Commissioning of of 10 Passenger lift gearless with Machine room Capacity(680 Kg), Shaft size (2130mm(Left to right)x2130mm(Front to back))Elevator G+1 Floors with ACVVVF drive/Control with ARD 1.25 MPS, SS honeycomb interior ,2hr fire rated door with simplex operation without attendant car position indicators,battery operated alarm bell & emegency light,SS honeycomb finish door finished car interior, recess Granite flooring ,power operated centre opening automatic sliding SS honeycomb finish doors for car entrance & hoist way entrance etc . . All the SS material shall be of SS-304 Grade and thickness not les than 1.2mm. Machine beams,buffer support channels,facia plate including sills pit ladder metal screen in Elevator pit etc.as per specifiaction including cost of (i)Overload detection,(ii)Voice announcement,(iii) Intercom,(iv)Braille Buttons v) Provision of flat cat 6 cable for cctv with all Civil & Electrical works required for installation of Elevator in the existing lift well and machine room,scaffolding ,floor cutting including Fireman's switch complete in all respect.The Elevator should be suitable for physically handicapped person. make:OTIS/Mitsubishi/Johnson/Schindler Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysDec 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender