Housing Urban and Rular Development Government Departments Closing in 5 days TDR #58600398

Tender For Installation Of Ac Machines And Led Lights And Wall Fan Including The Electrical Wirings In The Guest Room 6Th Floor A Wing Of Honble Mic Of This Department At The Office Building Of Shilpa Sadan ,4 An Tagore Sarani,Kol-16.

Issued by Government Departments · Kolkata, West Bengal
Tender Value
2.11 Lakhs
Estimated cost
Bid Submission
04 Dec 2026
5 days left
EMD
4231
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Installation Of Ac Machines And Led Lights And Wall Fan Including The Electrical Wirings In The Guest Room 6Th Floor A Wing Of Honble Mic Of This Department At The Office Building Of Shilpa Sadan ,4 An Tagore Sarani,Kol-16.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 27-Nov-2026 DATE CORRIGENDUM Date 04-Dec-2026

BOQ

Name of Work:- Installation of AC machines and LED lights and wall fan including the Electrical wirings in the Guest room 6th floor A wing of Honble MIC of this department at the office building of Shilpa Sadan ,4 An Tagore Sarani,Kol-16.
Sl. No. Item Description
1S & F 240V, OLP-3+, 27A Digital A.C. machine Starter as required including S&F of 4 module GI box including necessary connections (Voltcheck, Amp Check & Timecheck & 3 digit display). (Make: Electron)/as per direction of EIC
2S & F 2(+1) Module IP-65 rated waterproof cabinet on wall including necessary accessories with S&F 240V, 40 A isolator complete with connections, testing and commissioning etc. as required. (Make: Legrand)/L&T/ABB
3Wiring for circuit / submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable (Make: Polycab / KEI / Gloster / Havells) in surface / recessed medium class PVC conduit as required.
42 X 4 sq. mm + 1 X 4 sq. mm earth wire
5Finishing of the PVC insulated 2 X 4 sq. mm + 1 X 4 sq. mm wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
6Supplying, installation, Testing & Commissioning of 36 W Panel light 2x2 ft., of Powder coated die cast / Extruded aluminium Body (Thickness > 1.20 mm) material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (Make: Philips / Crompton)
7Supply & Delivery of 230 V, 50 Hz, single phase, 85 watts, 18\\" (450mm), speed 1325 rpm (minimum), Bracket Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body with metal back cover. Power Factor not less than 0.9 and minimum air delivery 110 cu.m/min (minimum), including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required.
8Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length.
9Supply & delivery of 230 V, 50 Hz, single phase, 40 watts , 9\\" (230 mm) Sweep, speed 1350 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 650 cmh (minimum) including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor singlecore cable and earthing etc. as required.
10Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
11Upto 450 mm sweep
12Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
13Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box / wooden block including connections etc. as required.
14Wiring for light point/ fan point/ exhaust fan point / call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
15Group C
16Dismantling the old damaged cassette type indoor unit including drainage lines, refrigerant pipe lines properly and keeping the same in safe place as per direction of the EIC.
17Supplying, Installation, Testing and Commissioning of Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), R-32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, 50 Hz ,1 /3 phase AC supply, including surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 Mtr (IDU to ODU), copper power and control cable upto 5.5 Mtr (IDU to ODU) including drain pipe, the system shall be capable of performing cooling, dehumidification, Air circulation, filteration & ventilation of following capacity with Scroll/rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS: 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electrotechnical Commission (IEC) 17025 standards/Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA) with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS: 1391 as required.Inverter Type- Cooling only (Make -Mistubirshi electric /O general/Daikin/as per direction of EIC.
183.0 TR with 5 Star BEE Rating
19Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing / brazing including accessories, insulated with XPLE Class-O tubular insulation / with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
209.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
2115.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
22S & F of additional following items for length exceeding 5.5 mtr for complete installation and commissioning of aboove AC machines.
23(i) 2.5 sqmm, 3/4 core copper cable (FRLS type)
24Supply & Laying of 25 mm dia PVC drain pipe with 6mm thick nitrile rubber insulation incl. necy. Accessories. (Make: Supreme / Oriplast)
25Making Iron Structure after supply 2\\"x2\\" (9 ft.), 12\\"x 1½\\" (10 ft), 1\\"x1\\"(28 ft) Iron angel and 3/4\\" (26 ft) flat after cutting the same fixing on outside flat wall, cutting the wall fitting the angels and stinting by sand & cement muter electric welding the angels for fitting outdoor and standing ground also making safety railing by welding iron Angel & flats and painting the structure enamel primer & paint. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58600398
AUTHORITY Government Departments
TENDER VALUE 2.11 Lakhs
LAST DATE 04-12-2026
Authority
Authority Name Public Works Department
Work Description Tender for Installation Of Ac Machines And Led Lights And Wall Fan Including The Electrical Wirings In The Guest Room 6Th Floor A Wing Of Honble Mic Of This Department At The Office Building Of Shilpa Sadan ,4 An Tagore Sarani,Kol-16.
Basic Detail
Tender No WBPWD/AE/72/PR/T/KCESD/I of 2026-27
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 27 Nov 2026
Submission Date 04 Dec 2026
Open Date 07 Dec 2026
Finance
Tender Value 2.11 Lakhs
Tender Fee Ref. Documents
EMD 4231
Exemption Not Available
Document List
2911.pdf
32335e85-af71-470c-a407-c5161619ac7f.html
BOQ_5213861.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 27, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 04, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 5 days
Dec 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Dec 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
pdf

2911.pdf

html

32335e85-af71-470c-a407-c5161619ac7f.html

xls

BOQ_5213861.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender