Tender For Renovation Of Conference Room (3Rd Floor), Discussion Room (2Nd Floor) And Staircase For Design Department
Tender Value
6.85 Lakhs
Estimated cost
Bid Submission
30 Nov 2026
8 days left
EMD
13720
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Renovation Of Conference Room (3Rd Floor), Discussion Room (2Nd Floor) And Staircase For Design Department
BOQ
| Sl. No. | Item Description |
| 1 | PART-A ( ELECTRICAL-SUPPLY PART) |
| 2 | Supply of 230VAC, 1Ø, 6-10 Watts LED as per the scope of work |
| 3 | Supply of 230VAC, 1Ø, 12-15 Watts LED modularrecess Down light fitting as per the scope of work |
| 4 | Supply of 600X600 mm, 34-36W 230VAC, 1Ø, LED light fitting as per the scope of work |
| 5 | Supply of picture light 10-12W as per the scope of work |
| 6 | Supply of 1x24 W LED Hanging profile lights as per the scope of work |
| 7 | Supply of track light 8-12W as per the scope of work |
| 8 | Supply of channel for track light as per the scope of work |
| 9 | Wiring for light point/ fan point/ exhaust fan point/ call bell point as per the scope of work |
| 10 | Wiring for circuit/ submain wiring alongwith earth wirewith the 2x1.5 sq.mm + 1x1.5 sq.mm earth as per the scope of work |
| 11 | Wiring for circuit/ submain wiring alongwith earth wirewith the 2x2.5sq.mm + 1x2.5 sq.mm earth as per the scope of work |
| 12 | Supply of 4 way TPN DB as per the scope of work |
| 13 | Supply of 4 pole 63A 30mA RCCB as per the scope of work |
| 14 | Supply of 4pole 63A MCB as per the scope of work |
| 15 | Supply of 1P 6/10/16/20/25A MCB as per the scope of work |
| 16 | Supply of 2M plate with frame as per the scope of work |
| 17 | Supply of 2M metal box as per the scope of work |
| 18 | Supply of 3M plate with frame as per the scope of work |
| 19 | Supply of 3M metal box as per the scope of work |
| 20 | Supply of 4M plate with frame as per the scope of work |
| 21 | Supply of 4M Metal box as per the scope of work |
| 22 | Supply of 6M plate with frame as per the scope of work |
| 23 | Supply of 6M Metal box as per the scope of work |
| 24 | Supply of 8M plate with frame as per the scope of work |
| 25 | Supply of 8M Metal box as per the scope of work |
| 26 | Supply of 1module 1way switch 6A as per the scope of work |
| 27 | Supply of 1module 1way switch 16A as per the scope of work |
| 28 | Supply of 2 module 6A socket as per the scope of work |
| 29 | Supply of 2 module 16A socket as per the scope of work |
| 30 | PART -A (ELECTRICAL INSTALLATION PART) |
| 31 | Installation of 230VAC, 1Ø, 6-10 Watts LED as per the scope of work |
| 32 | Installation of 230VAC, 1Ø, 12-15 Watts LED modularrecess Down light fitting as per the scope of work |
| 33 | Installation of 600X600 mm, 34-36W 230VAC, 1Ø, LED light fitting as per the scope of work |
| 34 | Installation of picture light 10-12W as per the scope |
| 35 | Installation of 1x24 W LED Hanging profile lights |
| 36 | Installation of track light 8-12W as per the scope of work |
| 37 | Installation of chanel for track light as per the scope of work |
| 38 | Wiring for light point/ fan point/ exhaust fan point/ call bell point as per the scope of work |
| 39 | Wiring for circuit/ submain wiring alongwith earth wirewith the 2x1.5 sq.mm + 1x1.5 sq.mm earth as per the scope of work |
| 40 | Wiring for circuit/ submain wiring alongwith earth wirewith the 2x2.5sq.mm + 1x2.5 sq.mm earthas per the scope of work |
| 41 | Installation of 4 way TPN DB as per the scope of work |
| 42 | Installation of 4 pole 40A 30mA RCCB as per the scope of work |
| 43 | Installation of 4 pole 63A 30mA RCCB as per the scope of work |
| 44 | Installation of 4pole 40A MCB as per the scope of work |
| 45 | Installation of 4pole 63A MCB as per the scope of work |
| 46 | Installation of 1P 6A/10/16/20/25A MCB as per the scope of work |
| 47 | Installation of 2M plate with frame as per the scope of work |
| 48 | Installation of 2M metal box as per the scope of work |
| 49 | Fixing of 3M plate with frame as per the scope of work |
| 50 | Fixing of 3M metal box as per the scope of work |
| 51 | Fixing of 4M plate with frame as per the scope of work |
| 52 | Fixing of 4M Metal box as per the scope of work |
| 53 | Installation of 6M plate with frame as per the scope of work |
| 54 | Installation of 6M Metal box as per the scope of work |
| 55 | Installation of 8M plate with frame as per the scope of work |
| 56 | Installation of 8M Metal box as per the scope of work |
| 57 | Fixing of 1module 1way switch 6A as per the scope of work |
| 58 | Fixing of 1module 1way switch 16A as per the scope of work |
| 59 | Fixing of 2 module 6A socket as per the scope of work |
| 60 | Fixing of 2 module 16A socket as per the scope of work |
| 61 | Dismantling of existing switch boards, disconnection of all cables with all accessories |
| 62 | PART -B ( SUPPLY AND INSTALLATION OF SPLIT AC ) |
| 63 | Supply of 5 STAR 2TR inverter split type AC Units as per the scope of work |
| 64 | Installation of 5 STAR 2TR inverter split type AC Units as per the scope of work Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysDec 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender