Tender For Repair To Rolling Shutter, Gates, Roof Truss, Repair/Maintenance Of Mes Installations And Complaint Cell At Af Stn Naraina Under Aor Of Ge (Af) Faridabad
Tender Value
25 Lakhs
Estimated cost
Bid Submission
09 Dec 2026
18 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair To Rolling Shutter, Gates, Roof Truss, Repair/Maintenance Of Mes Installations And Complaint Cell At Af Stn Naraina Under Aor Of Ge (Af) Faridabad
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed. |
| 2 | Taking down cement plaster including racking out joints, hacking for key and scrubbing down with water etc complete all as specified and directed. |
| 3 | M&L for 15 mm thick cement plastering in CM 1:4 on brick/concrete surfaces of roof and parapet, mixed with water proofing compound, finished even and smooth without using extra cement (Including 4 Story building) complete all as specified and directed. Note :- Water proofing compound shall be measured & paid separately. |
| 4 | Demolition of brick work built in cement mortar in any position including all quoins, arches & pillars etc complete all as specified and directed. |
| 5 | M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 6 | Taking down of old existing roof treatment of any description incl scrube and remove loose concrete, brick tiles, mud fuska, plaster, bitumen, oil grases and any other materials that might effect adhesion by wire brushing the surface and cleaning of the surface throughly with water and disposed off old materials from site complete all as specified and directed. |
| 7 | M&L for 50 mm thick cement concrete 1:2:4 type B-0 ( using 12.5 mm graded stone aggregate) as in padding/ base on roof complete all as specified and directed. |
| 8 | M&L for 20 mm thick plastering in CM 1:4 on RCC roof slab, finish even and smooth for receive water proofing APP membrane using WPC @ 3% by weight of cement, complete all as specified and directed.Note : WPC will be measured and paid separately. |
| 9 | Supply only Integral water proofing compound, complete all as specified and directed. |
| 10 | M&L for preparation of the plastered roof surfaces and fix the APP polymeric water proofing membrane of minimum 3 mm thickness & weighing not less than 3.0 kg / sqm of black finished reinforced with non-woven ployster 160 gsm matt with a thermofusible finish laid over primer conforming to IS:3384-1965 @ 0.5 kg/sqm and thereafter apply compitable hot blown bitumen 85/25 @ 1.20 kg/sqm torching overlaps with a propane or a butane gas torch with a overlap of 75 mm at the sides and 100 mm at the end sealing complete all as specified and directed. |
| 11 | Disconnecting existing PVC tanks of capacity exc 250 & n exc 500 ltrers, setting aside (or lowering if required) for repairs, Cleaning and removing all scale and dirt, etc. from tanks and form mouths of circulating pipes, etc. and hoisting if required reconnecting and re-fixing the same in position and restore water supply to accommodation complete all as specified and directed. |
| 12 | Disconnecting existing PVC tanks of capacity exc 500 & n exc 1000 ltrers, setting aside (or lowering if required) for repairs, Cleaning and removing all scale and dirt, etc. from tanks and form mouths of circulating pipes, etc. and hoisting if required reconnecting and re-fixing the same in position and restore water supply to accommodation complete all as specified and directed. |
| 13 | Supply and fixing for 15 mm bore steel water tubing galvanised 15mm bore, medium grade fixed to walls and ceiling or in floor including taking down of old GI lines complete all as specified and directed. |
| 14 | Supply and fixing in repair for 20mm bore steel water tubing galvanised, medium grade fixed to walls and ceiling or in floor including taking down of old GI lines complete all as specified and directed. |
| 15 | Supply and fixing in repair for 25 mm bore steel water tubing galvanised, medium grade fixed to walls and ceiling or in floor including taking down of old GI lines complete all as specified and directed. |
| 16 | M&L for preparation of newly plastered surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 17 | M&L for preparation of new or previously untreated plsatered or concrete surfaces and applying two coats of weather coat over a coat of primer complete all as specified and directed. |
| 18 | S&F 1.25mm thickness of laths steel rolling shutters, without ball bearing as specified including top cover, anchoring rod, hasp, staple and including gear operated type with bevel gear box and crank handle for rolling shutters and one shop coat of primer erected in position as indicated, complete all as specified and directed. |
| 19 | S&F Safety lever locks mild steel with 4 leavers for rolling shutters complete all as specified and directed. |
| 20 | M&L in applying two coats of synthetic enamel paint over a coat of red oxide primer to new steel and iron surfaces over 10cm in width or girth including preparation of surfaces complete all as specified and directed. |
| 21 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed. |
| 22 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm of an colour having tensile strength of 550 Mpa as in roof covering fixed on curved truss, fixed with self tapping screws complete all as specified and directed. |
| 23 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering fixed on curved truss, gutters etc fixed with self tapping screws complete all as specified and directed. |
| 24 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc) any thickness, including cover fillets and grid frame work, complete all as specified and directed. |
| 25 | M & L anodised aluminium snap grid frame work of size 605 x605mm for false ceiling including hanger 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5 mm dia 40mm long complete all as specified and directed. |
| 26 | M&L for 8 mm thick Exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid complete all as specified and directed. |
| 27 | M&L for providing PVDF aluminium composite panels with fire resistant mineral filled core material as in interior/exterior wall cladding upto G+2 storeyed external wall surface shall consist of following complete all as specified and directed. (I) Aluminium sheet making a total panel thickness of 3 mm with outer surface finished with PVDF based coating 0.25mm , inner surface finished with a thin coat of polyster paint. The thickness of aluminium cover sheet shall be 0.50 mm inner core shall be of LDPE (II) MS(Mild Steel ) tube framing of section 25 mmx50 mm x1.50mm thick , (III) MS (Mild steel) tube grid shall not be exceed 1.0 sqm each, the MS Tube grid not more than 1 m c/c shall be fixed with MS angle 30x30x5 mm projected 150mm from surface of wall, (IV) Colour shall be approved by GE. (V) Joint shall be sealed with silicon weather proof sealing compound with help of masking Tapes. Note: Canopy, borders, projections etc will be measured in sqm for payment purpose. |
| 28 | M&L for cut outs/ metal sign board of dogs Size 1.2m X 1.5m PVDF aluminium composite panels with fire resistent mineral filled core material printed with vinayl OR print with 3 M retro reflective tapes on ACP Sheet fixed on the ACP Sheet with the help of high bond double side taps Of 3M Grey VHB taps 2 mm thick including taking down of old sign board complete all as specified and directed Note: coloure and Type of dogs choice shall be approved by GE. |
| 29 | M&L for 3d Acrylic LED lighted letters OR print with 3 M retro reflective tapes on ACP Sheet above 12 inch including taking down of old ss letters complete all as specified and directed Note: Size shall be approved by GE. |
| 30 | M&L for Steel work in tubular trusses and purlins including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and directed. |
| 31 | M&L for Structural steel, rolled section such as joist, beam, channel, angle, tee, in available lengths Fe 410-W(Gde-E-250) quality-A complete all as specified and directed. |
| 32 | M/L for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed. |
| 33 | Dismantling of existing roof treatment of any description/thickness including dismantling of water proofing plaster etc complete all as specified and directed. |
| 34 | M&L for PCC 1:2:4, type B-0, using 12.5mm graded stone aggregate coping, benching, roof padding as levelling course complete all as specified and directed. |
| 35 | Supply only liquid water proofing compound complete all as specified and directed. |
| 36 | Cleaning top surfaces by brooming, wire brushing, removing grass, raking out joints to receive plaster and removing debris, grass etc outside the defence land complete all as specified and directed. Note :- 1. Plaster shall be measured and separately under appropriate item of Sch ‘A’. 2.Rate of this item is inclusive of diconnect fitment at water tank or solar heater etc and refixing in the same position after compeleting of roof treatment. |
| 37 | M&L for applying 3.00mm thick APP based polymer membrane over 85/25 industrial bituminous coat @ 3 Kg/Sqm over bituminous primer @ 0.30 Ltr/Sqm on newly plastered clean and dry roof surface. Top surface shall be finished with bituminous base Aluminium paint, all joint shall be Sealed by torch application complete all as specified and directed. |
| 38 | M&L for 5mm thick rendering in CM 1:3 on concrete/gunniting surface as in ceiling finished even and smooth w/o using extra incl taking down cement plaster or concrete, brick surface and raking out hacking for key scrubbing down with water to receive plaster complete all as specified and directed. |
| 39 | M&L for preparing old distempered surfaces of wall by complete removal of the existing treatment and applying two coats of oil bound distemper over a 1 mm thick uniform wall putty by using roller complete all as specified and directed. |
| 40 | M&L for preparing the old decorated plastered or un-plastered surfaces of ceiling by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spot and applying two coat of white wash by using roller complete all as specified and directed. |
| 41 | M&L for preparing the old decorated surfaces of wall, pillasters, cornices etc by complete removal of the existing treatment and applying one coat of apex exterior paint duly adding pigments to required colour filling all the holes and making uniform, smooth surfaceby using roller/ using smart periodical methodology complete all as specified and directed. |
| 42 | M&L for preparation of new painted wooden surfaces over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of white lead primer complete all as specified and directed. |
| 43 | M&L for preparing old distempered surfaces of wall/ceiling by complete removal of the existing treatment and applying two coats of oil bound distemper over a 1 mm thick uniform wall putty by using roller complete all as specified and directed by Engr-in-charge. |
| 44 | M&L for complete removal of existing treatment and applying two coats synthetic enamel paint over a coat of red oxide/zinc chrome primer including preparation of Old or new steel/iron surfaces exc 10cm in width or girth up to 4 storey building complete all as specified and directed. |
| 45 | M&L for two coat of Acrylic smooth exterior emulsion paint over one coat of acrlic primer for exterior/interior on old/New scraped wall/ceiling surfaces and obtain smooth finish using sand paper complete all as specified and directed.Note : Colour and make as approved by GE. |
| 46 | M&L for Cement concrete type D- 2,1:4:8 (40mm graded stone aggregate) and 75mm thick complete all as specified and directed. |
| 47 | Dismantling of floor, hearth or wall tiling including cement morter bedding (but not backing), removing serviceable tiles to the stores and rubbish off the premises, complete all as specified and directed. |
| 48 | M&L for Glazed ceramic coloured tiles in vertical surface 350 x250x 7 mm/ 450x 350x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15mm thick screed bed in cement mortar 1:4 Laid and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the shade of the Tiles, complete all as specified and as directed. |
| 49 | M&L Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.16 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match Laid on floor, over and including 15mm thick screed bed in cement mortar 1:4 Laid and Jointed in Neat Cement Slurry and pointed in White Cement with pigment to match the shade of the Tiles, complete all as specified and directed. |
| 50 | M&L Machine pressed precast concrete inter locking paver block any shape and size with Grey cement and no pigment conforming to IS 15658-2006 of 60mm thickness , M-35 Grade complete all as specified and as directed. |
| 51 | M&L rendering 15mm thick in cm 1:6 on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement incl taking down cement plaster or concrete, brick surface and raking out hacking for key scrubbing down with water to receive plaster, complete all as specified and directed. Note: The work to be executed at the hieght of 12 to 15 mtr the rate for necessary scaffolding deemed to be included in the qouted rate. |
| 52 | M & L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed. |
| 53 | Demolition of Cement Concrete (un-reinforced) of any description, not exc. 150mm thickness (above or below Ground Level) and removing the same from Site(s), complete all as specified and directed. |
| 54 | M&L for 25 mm thick PCC type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in laying of floor/sub base finishes complete all as specified and directed. |
| 55 | M& L for 2 mm thick dielectric epoxy flooring (Epoxy-cycloaliphatic amine) mixing resin to harderner in ratio 0f 2:1 by volume, drying time ASTM D 1640, theoretical coverage of 1 sq m/ litre/ coat @ 1000 microns, having compressive strength ASTM D 695. Lay the mix by a notched trowel to lay the desired thickness. De-aerate the layer by a spike roller and allow to cure for 24 hours with smooth glossy finish complete all as specified and directed. |
| 56 | S&F MS work as in post and strutt and fencing, drilled and countersunk for balusters running bars for doors balusters,noising to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts,posts and struts in fencing including cutting tops to shape as directed drilling hoes nothcing for wire etc flat iron fillets ( for securing wire mesh ) including all necessary drilling bolting or riveting etc. and similar work conforming to Fe - 290 Gde E - 165 complete all as specified and directed. |
| 57 | M&L in repair Vitreous China White Wash down Water Closet Pan (Pedestal Pattern) P & S type including Bolts, (excluding Flushing Cistern and Flushing Pipe) with white Plastic Seat cover, with Recessed Bottom closed pattern and Cover including Mild Steel Chromium Plated Aluminium Hanging Device and fixed-in-repairs, including Making Good disturbed Surfaces with Cement Mortar 1:3, complete all as specified and as directed. |
| 58 | S&F in repair PVC Flushing Cistern 10 LITRE capacity, Low Level Valve Less, Symphonic Action type, White, with Inlet, Ball Valve, Float and Handle including a Pair of Cast Iron Brackets duly Painted/Erecting Stand and PVC connection pipe 15mm size, PVC Flush Pipe of polythene 32mm dia for Low Level Flushing Cistern including Cutting and Pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3 and fixed including Taking down/out Unserviceable Flushing Cistern and connected Items, complete all as specified and as directed. |
| 59 | S&F in repair Vitreous China Wash Hand Basin 630X450mm in size, White (Flat Back Type) with 32mm dia Brass Chromium Plated Waste Fitting,UPVC Bottle trap, UPVC’ 32mm bore Waste Pipe, a Pair of Cast Iron Brackets duly Painted/ Erecting Stand including Cutting and Pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3 and fixed including Taking down Unserviceable Wash Hand Basin and connected Items, complete all as specified and as directed. |
| 60 | S&F in repair looking mirror 750x600x6mm thick selected quality glass mounted on 25mm size SS Stud fixed with CP brass screws complete all as specified and directed. |
| 61 | S&F in repair High pressure PVC connections pipe 600mm long suitable for 15mm size with Brass CP Check nut complete all as specified and directed. |
| 62 | S&F in repair SS Chromium Plated Towel Rail 600mm Long, as Approved, fixed including Taking down un serviceable Towel Rail of any description, complete all as specified and directed. |
| 63 | S&F in repair Angle Stop Cock 15mm Bore (dia), Chromium Plated, screwed down, screwed for Iron Pipe or for Brass Ferrule and fixed-in-repairs complete all as specified and directed. |
| 64 | S&F in repair Bib Cock 15mm Bore (dia), Chromium Plated Long Body Bib Cock, screwed down, screwed for Iron Pipe or for Brass Ferrule and fixed-in-repairs, complete all as specified and as directed. |
| 65 | S&F in repair brass CP fency Pillar Taps 15mm Bore, Cast Copper Alloy with Capstan Heads, screwed down high pressure with or without lettered ‘HOT’ or ‘COLD’ with long screwed Shanks and Fly-Nuts, screwed for Iron Pipe and fixed-in-repairs, complete all as specified and directed. |
| 66 | Taking down door/window frame with shutter of area n exc 1.50 sqm each and removing to store, complete all as specified and directed. |
| 67 | Taking down shutters only of size exc 1.00 Sqm but not exceeding 2.00 Sqm complete all as specified and as directed. |
| 68 | M&L for 35mm thick block board flush shutter with 0.90mm thick Sun Mica/lamination on both sides and 2nd class hard wood lipping alround including mortice Lock with Round Knob fixed in position and fixed to chowkats complete all as specified and directed. |
| 69 | S&F 150mm long Aluminium anodised handles, cast type, complete all as specified and directed. |
| 70 | S&F 200 mm long aluminium anodized barrel tower bolt of extruded section complete all as specified and directed. |
| 71 | S&F Mild Steel Butt Hinges 100mm, Medium Weight, Cold Rolled ISI Marked and fixed, complete all as specified and as directed. |
| 72 | Taking down existing steel rolling shutters size not exceeding 2.50m x 3.00m with all connecting items and repair/replace the lath of steel rolling shutters and locking arrangements, greasing, tightening of helical wire spring including welding wherever required, oiling, etc. complete to make in serviceable condition including gear box lock bearing etc and applying two coat of synthetic enamel paint including preparation of old painted surfaces and refixing in the same opening complete all as specified and directed. |
| 73 | M&L for Steel rolling shutters of thickness 1.25 mm, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified and directed. |
| 74 | Dismantling plain or corrugated steel sheeting,any guage, any thickness,including nainital or similar pattern roof coverings complete all as specified and directed. |
| 75 | M&L for 4.8 mm thick float glass ordinary quality' frosted glass and glazing with aluminum beeding and gasket to aluminum framework in square exc 0.50 sqm in each pane in repair complete all as specified and directed. |
| 76 | S & F for stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or wooden beads complete all as specified and directed. |
| 77 | S&F in repair 32mm Waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm-45gms/40mm-60 gms complete all as specified and directed. |
| 78 | Removing daberies/excavated material to a distance exceeding 1.5KM but not exceeding 5 KM and depositing where directed at a level n. exc 1.50 m above the starting point complete all as specified and directed. |
| 79 | Taking down carefully aluminum/copper point wiring (light, fan, switch, socket, power point, holder) complete includind fittings and fixtures and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified keeping aside serviceable items for reuse with in the same bldg and removing U/S items from site, complete all as specified and directed. Note : Refixing of serviceable fitting shall be measured and paid seperately. |
| 80 | Taking down carefully copper / aluminum two core sub main wiring of sizes 4/6 Sqmm cable any type and removing old material from site and making good disurbed surface complete all as specified and directed. |
| 81 | M&L in repairs,two single core PVC insulated cable with copper conductor multi stranded 4 Sqmm duly drawn through and including concealed PVC conduit suitable size as sub main with continuous earth wire 6 Sqmm size and connecting to common earth dolly complete all as specified and directed. (Flexible Copper Wire Used In FRLS) |
| 82 | M&L for point wiring in repairs complete with 1.5 sqmm single core multistranded copper conductor PVC insulated and unsheathed cable 1100 volts grade FRLS cable IS-694 marked drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, fixed in wall, on roof with GI saddles GI screws, rawal plugs (concealed conduit in wall wiring) with all fittings including Tee, junction boxes and provision of 2 mm thick pressed steel terminal box of suitable size with 3 mm thick hylam laminated white sheet cover for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with multistranded coper conductor of size 1.5 Sq mm (Nominal area) complete all as specified and directed for following (Color coding to be followed) |
| 83 | All as per item No 82 above but one three pin 5 Amps socket out let on the same board with other switches with 1.5 sq mm PVC insulated copper conductor for continuous earthing. |
| 84 | All as per item No 82 above but one three pin 5 Amps socket out let on independant board with 1.5 sq mm PVC insulated copper conductor for continuous earthing. |
| 85 | All as per item No 82 above but 15 Amps 3 pin socket outlet on independent board with 2.5 sq mm PVC insulated and sheathed copper conductor with 2.5 sq mm PVC insulated copper conductor single core for continuous earthing. |
| 86 | S&F Piano switch in repairs, flush button,single pole,one way 5/6 Amp, complete all as specified and directed. |
| 87 | S&F piano switch,in repairs, flush button single pole one way 15/16 Amp, complete all as specified and directed. |
| 88 | S&F socket outlet, in repairs,flush type 2 in 1, 2 pin and 3 pin 5 Amp complete all as specified and directed. |
| 89 | S&F socket outlet, in repairs,flush type 2 in 1, 3 pin and 6/16 Amp complete all as specified and directed. |
| 90 | S&F stepped type electronic fan regulator, in repairs, flush type on the existing phenolic laminated sheet etc, complete all as specified and directed. |
| 91 | S&F in repairs,ceiling rose surface backlight, 65 x 50 mm two to to three terminals complete all as specified and directed. |
| 92 | S & F flush type electronic fan regulator ,on the existing phenolic laminated sheet etc, complete all as specified and directed. |
| 93 | S&F in repairs,LED tube light batten,9/10W(+) 2% LED 6000K (2 ft.), 230 volts AC,Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver connector block,lamp etc complete with all accessories, internally pre-wired including twin core twisted flexible copper conductor of suitable size with PF -0.95,THD-10%,driver should be of same make as LED fitting,with in build over voltage ,under voltage and short circuit protection with operating range of 140 volst to 280 volts,isolation LED driver complete all as specified and directed. |
| 94 | Supply and fix flushed inside the wall MS sunken box more than 1mm thicknes of size 8\\"x10\\" complete all as specified and as directed. |
| 95 | S&F in repairs,sheet metal enclosure for MCB DB's SPN 240 volts, 4 way with neutral bus bar 200 Amp rated double door type regal grey complete all as specified and directed. |
| 96 | S&F in repairs MCB SP 6 to 32 Amps 240 Volts.\\"B\\" grade complete all as specified and directed. |
| 97 | S&F in repairs MCB SPN, 40 Amps, 240Volts .\\"B\\" grade complete all as specified and directed. |
| 98 | Supply and fixing in replacement of LED building security light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 99 | S& fixing LED flood light luminarie 120 W with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as specified and directed.Note : All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra cost to height upto 25 mtr |
| 100 | S&F in replacement street light GI pipe bracket 50 mm dia 1.50 metre length (ISI marked) light grade bend to shape with two Nos MS clamp duly painted nuts and bolts etc complete all as specified and directed. |
| 101 | M&L for earthing complete for pole with galvanized mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtr below ground level connected by using galvanised iron strip 25 X 4mm as earthing lead size by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber) 1:2:4 type B-1 using 20mm graded stone aggregate copy shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 funnel wiht wire gauge of 22 gauge (0.68mm) 8 mesh per liner inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm four MS bars @ 80mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 40mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, all excavation and earth work & connectiing the earthing to an earthing test point as specified and testing on complete all as specified and directed. |
| 102 | Supply and fix aluminium strip 25 mm x 3 mm complete with saddles and fixing screws etc for roof conductors and down conductors above ground level including removing u/s strips complete all as specified and directed. |
| 103 | Supply and fix single pointed air termination aluminium rod,12 mm dia, 300 mm long complete all as specified and directed. |
| 104 | S&F porcelain strip holder on wall and roof of suitable size including removing broken u/s one complete all as specified and directed. |
| 105 | M&L 32 mm GI pipe light grade of 1.3 mtr piece fixing in PCC cubical and complete connection of existing air termination rod complete all as specified and directed. |
| 106 | M&L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in coping and necessary form work, weathering slightly rounded or chamfered angles and throating etc complete all as specified and directed. |
| 107 | M&L for CI plate triangular with 500 mm long spike for writing earthing name and value complete all as specified and directed. |
| 108 | Supply and fixing in replacement of Retro reflective sign board of size 900 mm X 1200 mm made of ACP sheet of 3 mm thick. ACP Sheet will be fixed on SS (Stainless Steel ) frame of with legs of Stainless steel (SS) on PCC 1:3:6 type 2.10 m above The ground level and 750 mm below the ground level. The background of board to be provided with blue colour, letters and border with white retro reflective tape. Same description will be mentioned on both side of ACP Sheet.The size of letters and description will be as per directed by Engr-in-charge, board will be complete fixing/grouting with nut/bolts/Anchor fastener with washers. |
| 109 | Supply and fixing in replacement of Retro reflective sign board of size 600mmx1800mm made of ACP sheet of 3 mm thick. ACP Sheet will be fixed on wall , The background of board to be provided with blue colour, letters and border with white retro reflective tape. Same description will be mentioned on one side of ACP Sheet.The size of letters and description will be as per directed by Engr-in-charge, board will be fixed on Wall complete fixing/grouting with nut/bolts/Anchor fastener with washers complete all as specified and directed. |
| 110 | M&L for providing Display board of size 1m x 1m x1 cm madeup with acrylic sheet material consisting of \\"First Aid discription with pictures \\" in Capital Letter at the Top complete with fixing arrangements to the wall complete all as specified and directed. |
| 111 | M&L for providing Display board of size 1m x 1m x1 cm madeup with acrylic sheet material consisting of \\"First safety instruction with fire extenguishing methods with pictures \\" in Capital Letter at the Top complete with fixing arrangements to the wall complete all as specified and directed. |
| 112 | M&L for providing Display board of size 1m x 1m x1 cm madeup with acrylic sheet material consisting of \\"Safety instruction in case of electric shock with fire extenguishing methods with pictures \\" in Capital Letter at the Top complete with fixing arrangements to the wall complete all as specified and directed. |
| 113 | M& L for preparation of trench for cable laying of size 300mm x 450 x 10 m long including excavation & earth work in any type of soil brick work in CM 1:4, PCC work in 1:2:4 type B-1 using 20mm graded stone aggregate, plaster in CM 1:4 finished even & fair complete all as specified and directed. |
| 114 | Supply and fix cable duct cover made of MS of size 320mm x 800 mm of thickness 3.0 mm complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysDec 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender