Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #58593269

Tender For Special Repairs To Building No P-121 (Dsc Living Accommodation) At installation Dronacharya Under Ge Fort Kochi

Issued by Statutory Bodies & Commissions/Committees · Ernakulam, Kerala
Tender Value
40.35 Lakhs
Estimated cost
Bid Submission
09 Dec 2026
18 days left
EMD
80700
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repairs To Building No P-121 (Dsc Living Accommodation) At installation Dronacharya Under Ge Fort Kochi

BOQ

Name of Work:- SPECIAL REPAIRS TO BUILDING NO P-121 (DSC LIVING ACCOMMODATION) AT INS DRONACHARYA UNDER GE FORT KOCHI
Sl. No. Item Description
1Dismantling floor, hearth or wall tiling including cement screed mortar and wall plaster for any number of layers up to brick surface and removing and rubbish out of defence land etc. complete all as specified and as directed.
2Material and labour for 15 mm thick screed bedding layers in cement mortar 1:6 for laying floor finishes tiles etc. complete all as specified and as directed.
3Material and labour for non-skid ceramic-coloured tiles 7 to 8 mm thick with spacers area of each tile exceeding 0.09 sqm but not exceeding 0.11 sqm, as in floors installation and fixed with neat cement slurry and joints filled with epoxy joint sealant matching colour to match with tile colour, complete all as specified and as directed.
4Material and labour for Non-skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors, and shall be jointed in neat cement slurry and pointed in paste pigmented to tile shade etc. complete all as specified and as directed.
5All as per item No 4 above but as in skirting including necessary cutting etc. complete all as specified and as directed.
6Material and labour for Rendering 10 mm thick in cement mortar 1:4 on brick or concrete surfaces, finished fair and even for receiving wall tiles etc. complete all as specified and as directed.
7Material and labour for glazed ceramic tiles, coloured of size 7 mm thick area of each tile exceeding 0.12 sqm but not exceeding 0.18 sqm as in dado/skirting and riser to steps and jointed in neat cement slurry and pointed in white or coloured cement to match etc. complete all as specified and as directed.
8Material and labour for Dubbing out average 10mm thick in cement mortar 1:4 on irregular face of walls, complete all as specified and as directed.
9Demolition of cement concrete (reinforced) of any description (like Roof projection facia /fins, chajja, RCC water tanks etc and in any position not otherwise specifically provided for, complete all as specified and as directed.
10Material and labour for RCC 1:1.5:3 nominal mix, type B1 (using 20mm graded stone aggregates) for Slabs supported on walls, beams and columns in floors, roofs projection facia, landings, balconies, chajja, kitchen platforms & shelves etc complete all as specified and as directed.
11Formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc for flat rough finished surface of concrete also splays between floors and beams, etc, complete all as specified and as directed.
12Material and labour for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, slab, shelves etc, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.
13Demolition of Stone slabs and tiles of any description or thickness in platforms, floors, aprons laid in cement mortar etc. and rubbish off the premises etc. complete all as specified and as directed.
14Material and labour for 20 mm thick screed bedding layers in cement mortar 1:4 for laying topping layer of etc. complete all as specified and as directed.
15Material and labour for Granite 18mm thick (of any type) work (Rounded at edges and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite as approved by GE, (including providing of one hole 20mm dia to each Granite cooking platform for LPG Gas pipe) fixed with neat cement slurry including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade, complete all as specified and as directed.
16Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of Roofs (Fin wall/ Roof projection), floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, complete all as specified and as directed.
17Material and labour for Reinforced cement concrete M30 design Mix as in chajja, roof projections, fins, facias, slab, parapets, and railings etc. and the like complete all as specified and as directed.
18Formwork to chajja, roof projections, fins, facias, slab, parapets, and railings etc. troughs and similar items including edges, complete all as specified and as directed
19Material and labour for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, slab, shelves etc. hooking ends and binding/ welding with existing reinforcement bars including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.
20Material and labour for drilling holes 12mm dia, minimum 75mm deep and fix reinforcement bars using Lok-Fix (Manufactured by M/s Fosroc Chemicals India Ltd or equivalent) complete all as specified and as directed. Note: Reinforcement bars shall be measured and paid separately under respective item of BoQ.
21Taking down cement plaster of any description on walls including raking out joints, hacking for key scrubbing down with water etc. complete all as specified and as directed. (Note - water proofing compound shall be measured and paid separately).
22Material and labour for rendering 15 mm thick in two coats (5 mm thick in cement mortar 1:4 with water proofing compound over 10 mm thick plaster in cement mortar 1:4) on fair faces of brick work or concrete blocks surfaces finished even and smooth without using extra cement, complete all as specified and as directed.
23Material and labour for applying two or more coats of Weather coat premium exterior acrylic anti-fungal emulsion paint, UV resistance, alkali, fungal, and dirt resistance, of required shade, over and including a priming coat of exterior primer, including filling cracks with crack seal and filling depressions with exterior wall putty, over new and old prepared surfaces complete, all as specified and directed.
24Material and labour for 12 mm thick plastering in cement mortar 1:6, on internal walls finished even and smooth w/o using extra cement etc. complete all as specified and as directed.
25Supply and fix 1000 Ltr Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position connecting up pipes and tank nipple, securing access covers etc complete all as specified and as directed.
26Disconnecting existing PVC tanks (exc 500 Ltr), setting aside (or lowering if required), cleaning (removing all scale and dirt, etc) for roof treatment work /repairs, etc. and reconnecting and re-fixing in same position with new CPVC tank connector & union after completion of roof repair work complete all as specified and as directed.
27Taking down chowkats or frames not exc. 1.5 Sqm each with shutters (without taking off shutters from the frame) etc. complete all as specified and directed.
28Taking down chowkats or frames exc. 1.5 Sqm and not exc 4.00 sqm each with shutters (without taking off shutters from the frame) etc. complete all as specified and as directed.
29Supply and fix Factory made single extruded WPC (Wood Polymer Composite) solid door Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and nontoxic additives, fabricated with mitre joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with lugs/SS dash fasteners of required dia and length complete all as specified and as directed.
30Supply and fix 30mm thick factory made single extruded WPC (Wood Polymer Composite) solid decorative type (laminated wood grains) door shutter of size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and nontoxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and as directed.
31Supply and fix Factory made single extruded WPC (Wood Polymer Composite) solid door Frames/ Chowkhat of size 65x 125mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and nontoxic additives (maximum toxicity index of 12 for 100 gms) fabricated with mitre joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and as directed. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).
32Supply and fix Factory made single extruded WPC (Wood Polymer Composite) solid door Frames/ Chowkhat of size 65x 100mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and nontoxic additives (maximum toxicity index of 12 for 100 gms) fabricated with mitre joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and as directed. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).
33Supply and fix 35mm thick Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type (laminated wood grains) door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and nontoxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and as directed. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
34Supply and fix 35mm thick WPC Skeleton Decorative finish (prelaminated /wood grains) Gauzed Door Shutter with top panel and Both Vertical panels (left & Right Side ) with stiles100 mm wide, Top rail 150mm , Middle rail and bottom rail 200mm wide with and including fixing of Stainless steel (Grade 304 grade) wire cloth of 0.36mm nominal dia and width of aperture 1.40mm including WPC beading to fix the wire mesh inside the door panel and fixing with complete all as specified and as directed. (Note: The rate quoted is inclusive of wire mesh).
35Supply and fix stainless steel butt hinges 100mm size medium weight etc. including SS screws complete all as specified and as directed.
36Supply and fix anodised aluminium extruded handles 150 mm size etc. complete all as specified and as directed.
37Supply and fix aluminium anodised barrel tower bolts of extruded section 200 mm size etc. complete all as specified and directed.
38Supply and fix aluminium alloy, anodised sliding door bolt 250 mm long with hasp, staple (bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy etc. complete all as specified and as directed.
39Providing and fixing factory made UPVC white colour casement (Openable) window, Area not exceeding 1.00 sqm each made of extruded profiles with wall thickness of 2.3mm (+ – 0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 73mm), T profile (One vertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x 20mm) will be metered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 +– 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27.5mm). T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners and sealed with silicon sealant all around the frame internal and external side. Hardware: [casement handle made of zinc alloyed (white powder coated), But Hinges of' zinc alloyed (white powder coated), transmission gear made of mild steel with multi point locking system] and glazing with selected quality glass, complete all as specified and as directed. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories)
40Supply and fix 5 mm thick Sheet glass, ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane etc. complete all as specified and as directed.
41Supply and fix Stainless steel wire cloth (Grade 304) 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc. complete all as specified and as directed.
42Material and labour for powder coated aluminium deco grill of approved colour, design & pattern, with approved standard section fixed to window frame with 'F' channels & stainless-steel screws @ 200 mm centre to centre, complete all as specified and as directed.
43Material and labour for 18mm thick solid WPC (wood polymer composite) boards one side prelaminated with wood grains with having density not less than 650Kg/cum and having good screw holding capacity, fixed with SS screws as in cupboard & Kitchen cabinets complete all as specified and as directed.
44Supply and fix SS clip-on soft close concealed cabinet hinges fixed with SS screws of Make: Hettich, Godrej or equivalent in approved make etc. complete all as specified and as directed.
45Supply and fix 30 mm wide Continuous (piano) hinges, bright finish or electro galvanised mild steel ISI Marked etc. complete all as specified and as directed.
46Supply and fix anodised aluminium extruded handles 100 mm size etc. complete all as specified and as directed.
47Supply and fix magnetic door catcher with ABS body, strong magnet, SS plate, dual mounted etc for cupboards shutters fixed with screws complete all as specified and as directed.
48Supply and fixing in repairs 140mm floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed.
49Supply and fixing in repairs 200 mm, Mild steel ordinary rat tail rod pattern springs including roller and roller plate complete
50Supply only 4 mm thick Figured glass, pin head type not exc 0.5 sq. m in each pane square/ rectangular in shape complete all as specified and as directed.
51Supply and fixing in repairs drapery curtain rods stainless steel of dia 25 mm and thickness not less than 18 gauge including ornamental brackets & designer dooms complete all as specified and as directed.
52Demolition of brick masonry built in cement mortar or cement lime mortar etc. complete all as specified and as directed.
53Material and labour for precast cement concrete 1:3:6, type C1 (using 20 mm graded stone aggregate) block masonry with solid blocks, 10 cm thick or above in width and setting in cement mortar 1:6 etc. complete all as specified and as directed.
54Supply and fixing in repairs vitreous China wash down water closet (Pedestal pattern) white with 'P' trap complete including plastic seat cover white closed pattern with flat bottom, and cover with plastic hinges complete all as specified and as directed.
55Supply and fixing in repairs PVC low level flushing cistern 10 Ltr capacity including float valve and flush pipe etc complete all as specified and as directed.
56Supply and fixing in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25m long flexible tube and ABS wall hook, fixed in position complete.
57Supply and fixing in repairs vitreous China wash basin, white oval type size 550 X 400 mm excluding taps, fixed over RCC shelf and Granite platform, finished with white cement including 32 mm brass CP waste coupling, waste pipe etc complete all as specified and as directed.
58Supply and fixing 450mm long Shelf of PTMT fixed with and including Chromium plated brass screws and plastic cleats (Minimum weight 300gms) complete all as specified and as directed.
59Supply and fixing in repairs quarter turn pillar taps long body, fancy type 15mm bore cast copper alloy, with capstan head, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe and fixed, complete all as specified and as directed.
60Supply and fix in repairs long body bib cock, fancy type, Brass CP 15mm bore cast copper alloy with crutch or butterfly handle, screwed down complete all as specified and as directed.
61Supply and fix in repairs angle stop valve, fancy type, Brass CP 15mm bore cast copper alloy with crutch or butterfly handle, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and as directed.
62Supply and fixing in repairs 125mm dia Brass CP shower roses with or without swivel joints, including fixing with shower arm 15 mm size, 195 mm long with bend of 45 degrees with flange, complete all as specified and as directed.
63Supply and fixing in repairs 15mm Stop valves, cast copper alloy, screwed down, high pressure, fancy type, chromium plated with long shank and cup (concealed type), screwed both ends for iron pipe or for unions and fixed to plumbing pipe complete all as specified and as directed.
64Supply and fixing in repairs PVC inlet connections 450mm long, 15 mm bore with PTMT nuts etc complete all as specified and as directed.
65Supply and fixing in repairs 600mm x 600mm bevelled edge mirror of selected quality glass (frameless) with stainless steel bracket and screws complete all as specified and as directed.
66Supply and fixing in repairs 600mm long tubular towel rail, brass chromium plated, etc. complete all as specified and as directed.
67Supply and fixing in repairs Stainless steel soap dish fixed with SS screws etc. complete all as specified and as directed.
68Supply and fixing in repairs sink with drainage boards made of stainless steel 1 mm thick kitchen with plugs, washers and waste; including bedding in cement mortar to dwarf wall/Granite or including fixing and connecting union to pipe overall size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete (sink counter sunk into granite platform) etc. complete all as specified and as directed.
69Demolition of cement concrete (unreinforced) not exc 15 cm thickness (below or above ground floors) complete all as specified and as directed.
70Material and labour for PCC 1:2:4 type B0 (using 12.50 mm graded crushed stone aggregate) as in kerbs, coving, coping mud stops, rounded or chamfered on edges complete all as specified and as directed.
71Material and labour for PCC thick, PCC 1:2:4, Type B1 (using 20mm graded crushed stone aggregate) as in plinth protection finished even and smooth etc. complete all as specified and as directed.
72Material and labour for PCC 1:3:6 (Type C2) using 40mm graded crushed stone aggregate as in surface channels and drain etc. complete all as specified and as directed.
73Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed.
74Supply and fixing in repairs for PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to wall with GI Cradles complete all as specified and as directed. (The portion of pipe inserted to the masonry /slab shall be fixed with water proofing bath seal tape two way to the entire width of masonry/slab.). Note: - Pipe are to be fixed away from the wall using suitable GI Cradles, nuts and bolts etc. complete all as specified and directed.
75`-Dito- all as per item No 74 above but 75 mm dia etc. complete all as specified and as directed.
76`-Dito- all as per item No 74 above but 50 mm dia etc. complete all as specified and as directed.
77Supply and fix PVC SWR bends 110 mm dia bend of any radius with access door etc. complete all as specified and as directed.
78Supply and fix PVC SWR bends 75 mm dia bend of any radius with access door etc. complete all as specified and as directed.
79Supply and fix 110 mm dia PVC SWR junction single, (Single T) equal or unequal or 'Y' junction of any radius with access door etc. complete all as specified and as directed.
80Supply and fix 75 mm dia PVC SWR junction single, (Single T) equal or unequal or 'Y' junction of any radius with access door etc. complete all as specified and as directed.
81Supply and fix PVC vent cowl 110 mm dia etc. complete all as specified and as directed.
82Supply and fix PVC vent cowl 75 mm dia etc. complete all as specified and as directed.
83Supply and fix 75 mm PVC (SWR) floor trap with grating including jointing with solvent cement complete all as specified and as directed.
84Supply and fix 75 mm PVC (SWR) Multi floor trap with grating including jointing with solvent cement complete all as specified and as directed.
85Taking up or down 20mm dia steel / UPVC pipe tubing and connections, including cleaning for refixing, complete all as specified and as directed.
86Supplying and laying 20mm (Outer dia) of CPVC pipes SDR 11 & CPVC SDR 11 fittings with solvent on walls/ ceiling or laying in floors complete all as specified and as directed.
87Taking up or down 25/40mm dia steel/ UPVC pipe tubing and connections, including cleaning for refixing, complete all as specified and as directed.
88Supplying and laying 25mm (Outer dia) of CPVC pipes SDR 11 & CPVC SDR 11 fittings with solvent on walls/ceiling or laying in floors complete all as specified and as directed.
89Supplying and laying 40mm (Outer dia) of CPVC pipes SDR 13.5 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors complete all as specified and as directed.
90Supply and fix 25 mm Stop/Gate valve of PTMT any colour high pressure screwed for CPVC pipe and fixed, complete all as specified and as directed.
91Supply and fix 40mm Stop/Gate valve of PTMT any colour high pressure screwed for CPVC pipe and fixed, complete all as specified and as directed.
92Complete removal of existing treatment on wall surfaces any description, washing using water pressure jet, rubbing down and stopping of old painted surface, complete all as specified and as directed.
93Material and labour for applying 1.5mm thick wall care putty in two layers (first layer 1 mm thick second layer 0.5mm thick) over newly plastered surface/old prepared surface complete all as specified and as directed.
94Material and labour for applying a coat of internal acrylic primer over prepared surface complete all as specified and as directed.
95Material and labour for preparation of new or old plastered surface of wall and applying two coats of oil bound distemper complete all as specified and as directed.
96Material and labour for preparation of surfaces of ceiling and applying two coats of distemper oil emulsion on ceiling complete tall as specified and as directed
97Complete removal of existing treatment by scrapping external wall surfaces and Finishing walls with Acrylic Smooth exterior paint of required shade work (Two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) new or old prepared plastered external surfaces and including scaffoldings and cradles including hoisting and lowering as required with bracing, support complete all as specified and as directed. Note: Height of the Bldg is approx 10.00 m.
98Cleaning and removing all scale and dirt, etc, from RCC tanks (exc 1000 not exc 2000 ltr) and from mouths of circulating pipes, etc. complete all as specified and as directed.
99Material and labour for plastering with Nitobond SBR (Styrene butadin polymer bonding agent cum cement mortar/concrete modifier Manufactured by M/s Fosroc Chemicals India Ltd or equivalent) modified cement mortar (1:4) under the RCC water tank/slab to an average thickness of 30 mm (applied in two layers not exceeding 15mm each) , including the cost of all materials rent of tools and labour charges etc. complete all as specified and as directed.
100Taking down existing water proofing treatment of any thickness from the roof /parapet including cement mortar bedding, PCC tiles, padding concrete if any, up to the RCC slab, removing debris out of the premises and cleaning the roof complete all as specified and as directed.
101Cutting the Groove 5mm wide and 10mm deep on the terrace mother slab top and bottom wherever cracks are observed, cleaned with blower and providing and applying low viscous epoxy grout Fosroc Nitofill EPLV or equivalent into the grooves and fillig the crack from below (soffit of slab) with Fosroc Nito seal PU40N/PU50N or equivalent complete all as specified and as directed.
102Material and labour for 40 mm thick levelling course of cement concrete type B-0, 1:2:4, using 20 mm stone aggregate, 40 mm thick by adding a water proof admixture @ 200 ml per bag of cement. Note: - Admixture shall be measured and paid separately.
103Material and labour for rendering with cement mortar 1:3, 10 mm thick mixed with water proofing admixture of Fosroc/ Pidilite or equivalent, complete all as specified and as directed. Note :-Admixture shall be measured and paid separately.
104Supply only liquid water proofing admixture etc. complete all as specified and as directed.
105Material and labour for application of High-Performance Solar Reflective Elastomeric Liquid-Applied Roof Waterproofing System complete all as specified and as directed: -(a) Thorough cleaning work, removal of loose screed, and filling minor cracks with PU sealant.(b) Applying one coat of water base primer WB (water base at a ratio 1:2) on a well-prepared as per manufacturer-recommendation.(c) Once primer is fully dry, apply a coat of one-component Acrylic Polyurethane (PU) Modified, Elastomeric, Solar Reflective Cum Waterproof Coating by roller and brush.(d) A layer of Fibre Mesh Reinforcement of 45 gsm embedded with first coat.(e) Over fibre mesh, applying second and third one-component Acrylic Polyurethane (PU) Modified, Elastomeric, Solar Reflective Cum Waterproof Coating by roller and brush to fully cover the fibre mesh and make the surface even.(f) Waterproofing membrane system continued to be applied on the parapet wall up to 300mm height or as per manufacturer's instructions.Make : Asian Paints(SmartCare Damp Proof Ultra)/ Dr. Fixit (Newcoat Cool /Roofseal Flex)/ SIKA (SikaFill-100/Sikalastic-560/ Sikalastic Cool Roof)/ Fosroc (Brush bond Roofguard Premium)/ Bostik (Boscoseal PU-X).
106Material and labour for 5 mm thick plain embossed PVC false ceiling boards of size 595mmx595mm of density 600 Kg/Cum, plain colour decorative type fixed with and including pre powder coated white GI snap grid frame work of size, main runner 24x38x0.32mm, cross tee 24x28x0.3mm and wall angle 19x22x0.4mm to be placed at desired level fixed with 4mm dia GI suspender wire @1.20 centre to centre with wooden rafter/ perlins including dismantling of old existing false ceiling with grid complete all as specified and as directed by Engr-in-Charge. Make:- SMP Emplex Magma/ Sintex Industries/ Madhu Industries etc
107Material and labour for 75 mm thick PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in sub base lean concrete, complete all as specified and as directed.
108Material and labour for 60mm thick Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, complete all as specified and as directed. Note: Colour , pattern and size will be approved by GE.
109Material and labour for 50 mm thick cushion of coarse aggregate of size 6.3 mm and below, spread, rammed and levelled to receive paver blocks complete all as specified and as directed.
110Material and Labour for preparation of old painted steel surfaces of any description, not otherwise described, over 10cm width or girth and applying a coat of synthetic enamel anti corrosive paint of required shade complete all as specified and as directed.
111Taking down copper / aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or taking credit and making good the disturbed surfaces of walls, floors, etc, complete all as specified and as directed.
112Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and as directed.
113Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and as directed.
114Material and labour for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC conduit of white/ ivory colour including all accessories heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly including cutting wall/PCC, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and as directed for the following :-
115One light/fan/exhaust point controlled by one switch.
116One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board.
117One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
118Description all as per item No 114 here in before but using 2.5 sq mm single core copper conductor cable of multistranded FRLS PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of 2.5 sq mm copper conductor FRLS PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly.
119Supply and fix modular type Fan step regulator, 120W - 2 module all as specified and as directed
120Supply and fix Modular switch 06 Amp, single pole, one way, 230 Volt complete all as specified and as directed.
121Supply and fix Modular switch 16 Amp, single pole, one way, 230 Volt complete all as specified and as directed.
122Supply and fix ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified and as directed.
123Supply and fix Modular socket outlet 2 in 1, 3 pin, 06 Amp flush type, 230 volt, complete all as specified and as directed
124Supply and fix modular socket outlet multipurpose 2 in 1, 3 pin, 06 Amp and 16 Amp flush type, 230 volts, complete all as specified and as directed.
125Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB,240 volt, 20 Amps complete all as specified and as directed. Make: Havells, L& T, ABB
126Disconnection of electrical wire from ceiling fan 1200/1400mm sweep any make, dismantling the ceiling fan from existing position, and reassembling the repaired ceiling fan and testing to the entire satisfaction of engineer in charge and hanging at position with nut, bolts washers etc, connection with point wiring & testing complete all as specified and as directed. Note: - (Rewinding of ceiling fan will be measured and paid separately under respective item for material and labour cost.)
127Material and labour for rewinding of ceiling fan 1200/1400mm sweep any make by dismantling of fan motor, cutting and removing of burnt windings, cleaning the motor slots, rewinding the motor with supper enamelled copper wire of appropriate gauge, provision of insulation paper, applying of varnish, heating/ baking the motor to achieve the proper insulation resistance cleaning and removing of old bearing/bush and replacing with new bearing and bushes, capacitor and carrying out fresh lubrication using grease including replacing capacitor 2.5 mfd and to make free for smooth functioning complete all as specified and as directed.
128Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 300m, complete all as specified and as directed.
129Disconnection of electrical wire from exhaust fan 250/300mm sweep any make dismantling the exhaust fan from existing position, and reassembling the repaired exhaust fan and testing to the entire satisfaction of engineer in charge and hanging at position with nut, bolts, washers etc, connection with point wiring & testing complete all as specified and as directed. Note: - (Rewinding of exhaust fan shall be measured and paid separately under respective item.)
130Material and labour for rewinding of exhaust fan 250/300 MM sweep any make by dismantling of fan motor, cutting and removing of burnt windings, cleaning the motor slots, rewinding the motor with supper enamelled copper wire of appropriate gauge, provision of insulation paper, applying of varnish, heating/ baking the motor to achieve the proper insulation resistance cleaning and removing of old bearing/bush and replacing with new bearing and bushes, painting ,carrying out fresh outer louver cover to make free for smooth functioning complete all as specified and as directed.
131Supply and fix LED building security light fitting 35Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket of suitable dia up to 1.5 m length & necessary arrangements to fix it on wall/building with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed
132Supply and fix in replacement of surface mounted LED tube light fitting four feet long, 20 Watt with IP 20 protection comprises of aluminium extruded channel, extruded aluminium body, integrated electronic driver etc. and all accessories pre-wired including connecting up complete all as specified and as directed.
133Material and labour for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sqm nominal area and drawing into suitable size of PVC non-metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessories ISI marked heavy duty of suitable size including concealed in wall etc two runs of PVC insulated with 6 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note: - Four runs of 6 sqmm cable, two runs of 6 sqmm cable and one run of PVC conduit will be measured as one unit
134Material and labour for sub main wiring with 2 single core PVC insulated unsheathed 1100 Volt grade multistranded FRLS copper conductor of size 4 Sq mm drawn through existing conduit and accessories and 4 sq mm FRLS copper conductor cable as earth continuity conductor and connected to common earth dolly, complete all as specified and as directed.
135Supply and fixing in repairs of sheet metal enclosure distribution board, triple pole and neutral, vertical type, AC, 415-volt, 08 way with 200 Amp rated copper bus bar and double door complete all as specified and as directed.
136MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA rupturing capacity, C-curve type including taking down of existing unserviceable complete all as specified and as directed.
137Supply and fixing in repairs MCB SP 40 Amp, 240 volts of 10 KA rupturing capacity, C-curve type including taking down of existing unserviceable complete all as specified and as directed.
138Supply, install, testing and commissioning of factory made vermin proof Main LT panel Outdoor Feeder Pillar type, self-supported, CPRI Approved make, front and rear openable, double door hinged type with locking arrangement and slopping top canopy, suitable protection with dust and vermin proof etc, fabricated out of 3mm thick CRCA sheet duly powder coated with 7 tank chemical process, mounted fixed on and included MS angle section 50 x 50 x 6 mm on PCC 1:2:4 type B-1, platform 60 CM above the ground level and 45 CM below the ground level, factory fabricated with front and back openable double door system with and lock openable by keys, having chromium plated 19 mm dia fancy lock, louvers and air vent, gasket including following:a) Copper bus bar 600 Amps cap 4 wire fixed on insulator not less than 1.0 mtr long bus bar -1 set Incomer (a) Incoming MCCB 250 Amps, 4 pole, 415 Volts AC having rupturing capacity 36 KA - 01 NosOutgoing (a) Outgoing MCCB 160 Amps, 3 pole, 415 Volts AC having rupturing capacity 25 KA - 03 Nos (b) Digital Voltmeter 0 - 500 volt of size 96 x 96 mm square with selector switch -01 Nos.(c) Indicator Lamp LED type(R-Y-B) with holder-01 set of three. (d) CT's Coils of suitable ratio - 01 Set (e) Electronic timer switch FM/1 quarts of L & T or equivalent with Contactor of type MNX 40 3 pole contactor of Cat Part No CS94190 of make L & T or equivalent & all controls pre-wired.
139Material and labour for XLPE insulated PVC sheathed armoured with multistranded aluminium conductor cable having cross sectional area 120 Sqmm 3.5 core, 1100-volt grade, Heavy duty conforming to IS :7098 (Part 2) laid in trenches/Ducts or passing through pipes or fixing on poles etc complete all as specified and as directed.
140Material and labour for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.3mm thick, buried directly in Set ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel Gl protection pipe 15mm bore light grade all as shown in electrical plate No 3 on serial page No 497 of SSR part 2009 and connected to main switch board / Main DB's including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, Gl pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm centre to centre both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58593269
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40.35 Lakhs
LAST DATE 09-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repairs To Building No P-121 (Dsc Living Accommodation) At installation Dronacharya Under Ge Fort Kochi
Basic Detail
Tender No 8437/E8_GE_FORT_KOCHI
Bidding Type Tender
Location
City Ernakulam
State Kerala
Key Dates
Publish Date 18 Nov 2026
Submission Date 09 Dec 2026
Open Date 16 Dec 2026
Finance
Tender Value 40.35 Lakhs
Tender Fee 500
EMD 80700
Exemption Available
Document List
53a2ee10-5142-4f81-9b71-8b7a4f0ea90e.html
8437Tenderdocu.pdf
BOQ_896785.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Dec 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
html

53a2ee10-5142-4f81-9b71-8b7a4f0ea90e.html

pdf

8437Tenderdocu.pdf

xls

BOQ_896785.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender