Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #58593251

Tender For special Repair To Roof Treatment Of Bldg No. P-16, P-17, P-43 & P-02 And Provn Of Hard Standing For Heavy Vehs Near Mt (Bldg No P-21) Of Med Regt At Old Amritsar Cantt

Issued by Statutory Bodies & Commissions/Committees · Amritsar, Punjab
Tender Value
46.18 Lakhs
Estimated cost
Bid Submission
07 Dec 2026
16 days left
EMD
92500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Amritsar → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair To Roof Treatment Of Bldg No. P-16, P-17, P-43 & P-02 And Provn Of Hard Standing For Heavy Vehs Near Mt (Bldg No P-21) Of Med Regt At Old Amritsar Cantt

BOQ

Name of Work:- SPL REPAIR TO ROOF TREATMENT OF BLDG NO. P-16, P-17, P-43 & P-02 AND PROVN OF HARD STANDING FOR HEAVY VEHS NEAR MT (BLDG NO P-21) OF MED REGT AT OLD AMRITSAR CANTT
Sl. No. Item Description
1Taking down cement plaster on brick or concrete walls, ceiling etc, including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engineer-in-charge.
2M&L 15 mm thick cement plaster in CM 1:4 mixed with liquid water proofing compound @ of 3% as on other than fair face of brick or concrete surface of walls finished surface even and fair complete all as specified and as directed by Engineer-in-charge. Note : (i) Supply only water proofing liquid shall be measured and paid separately & upto the height of bldg upto 7.5 mtrs
3Supply only liquid water proofing compound to mixed with cement mortar etc, complete all as specified and as directed by Engineer-in-charge.
4M&L for preparing New plastered surfaces applying two or coats of 100% Premium acrylic emulsion paint having VOC less than 50 Gm/litre and UV resitance as per IS 15489: 2004, Alkali & fungal resisitance, dirt resitance extterior paint of required shade (Company Depot Tinted) withsilidon addiitives @ 1.43 litr/10 Sqm over and including priming coats of exterior priomer applied @ 0.90 litrs/10 Sqm over new surfaces all as specified upto the height of bldg 7.5mtrs complete all as specified and as directed by Engineer-in-charge.
5M&L for preparing old plastered surfaces applying two or coats of 100% Premium acrylic emulsion paint having VOC less than 50 Gm/litre and UV resitance as per IS 15489: 2004, Alkali & fungal resisitance, dirt resitance extterior paint of required shade (Company Depot Tinted) withsilidon addiitives @ 1.43 litr/10 Sqm over and including priming coats of exterior priomer applied @ 0.90 litrs/10 Sqm over new surfaces all as specified upto the height of bldg 7.5mtrs complete all as specified and as directed by Engineer-in-charge.
6Demolition of brick work built in cement mortar incl all quoins, arches, pillars etc, complete all as specified and as directed by Engineer-in-charge.
7M&L for brick work with sub class \\"B\\" bricks, straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and as directed by Engineer-in-charge.
8Dismantling of brick tiles or terracing tiles single layer on roof complete all as specified and as directed by Engineer-in-charge.
9Demolition of Mud in roof any thick ness including plastering and leeping (Whether full thickness removed or only a part thereof), Complete all as specified and as directed by Engineer-in-charge.
10M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) mixed with water proofing liquid as in padding, in roof kerb to amintain slop correction of the depressed undraution portion complete all as specified and as directed by Engineer-in-charge.
11M&L for APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric( weight not less than 150 gms/sqm) laid on primed surface by forced application with and including approved bitumen primer as per manufacturer's instructuions including cleaning the surfaces complete all as specified and as directed. Note : (i) Sheet shall be five layered prefabricated Atactic Polypropyleon Polymer (APP) modified 3mm thick membrane (weighing not less than 3 kg/sqm) reinforced with 150 gsm polyester non-woven fabric. (ii) Concrete of roof surface shall be scratched with scratched tool before finishing roof surface when the concrete surface is still green, 10mm thick 1:4 cement plaster shall be laid. (iii) The roof surfaces shall be throughly wire brushed, washed, dried up and cleaned to all foreign matter and dust prior to the appliction of primer. (iv) On the dried surface one coat of approved bituminous primer, having density in the range of 0.87 to 0.89 kg/litre at 25 degree centigrade and viscosity of 40 to 160 CPS, manufactured by same manufacturer @ 0.4 litre / sqm shall be applied. (v) APP membrane shall be laid on primed surface by torch application method after allowing 24 hours for primer to dry. (vi) Laying off APP membrane will normally be laid in length at right angle to the direction of slope. (vii) The overlaps shall be of minimum 100mm on longitudinal direction and 150 mm on the transverse direction. All overlaps shall be bonded with bitumen primer and levelled by heating the overlaps with butane torch the treatment shall be done by the approved authorised applications complete all as specified and as directed by Engineer-in-charge.
12M&L for 40mm thick brick tiles laid on concrete roof padding over and including 15 mm thick cement screed bed in CM (1:6) using grey cement, jointed and grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and as directed by Engineer-in-charge.
13All as per item No. 12.00 here in-before above but EXCEPT TILES Note :- Old dismantled serviceable bricks obtained from Srl item No. 8.00 shall be reused after necessary cleaning of mortar
14M&L for nominal mix concrete type 1:1.5:3 (20 mm graded aggregate) in roof Kerb or mud stops, rounded chamfered on edges after treatment of roof surface Complete all as specified and as directed by Engineer-in-charge.
15S&F 110mm PVC (SWR) pipe single socket in any length with rubber ring joints fixed in walls, complete all as specified and as directed by Engineer-in-charge.
16S&F 110 mm PVC (SWR) bend any radius joints fixed in walls complete all as specified and as directed by Engineer-in-charge.
17S&F in repair PVC T-Base for water tank capacity 1000Ltrs (Dimension 1100mm dia, leg height -80mm leg width 60mm and height 130mm complete all as specified and as directed by Engineer-in-charge. MAKE :- Vectus or equivalent make as approved by GE.
18S&F in repair PVC T-Base for water tank capacity 1000Ltrs (Dimension 1100mm dia, leg height -80mm leg width 60mm and height 130mm Complete all as specified and as directed by Engineer-in-charge. MAKE :- Vectus or equivalent make as approved by GE.
19Disconnecting existing tank of capcity 500 ltrs setting aside (or lowering if required) for repair, cleaining, etc and hosting if required reconnecting and re-fixing in postion complete all as specified and as directed by Engineer-in-charge.
20Disconnecting existing tank of capcity 1000 ltrs setting aside (or lowering if required) for repair, cleaining, etc and hosting if required reconnecting and re-fixing in postion complete all as specified and as directed by Engineer-in-charge.
21Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
22Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 Mtr in depth for foundation in soft/loose soil and getting out complete all as specified and as directed by Engineer-in-charge.
23M&L for hardcore broken stone or boulders of guage exc 63mm but not exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and as directed by Engineer-in-charge.
24M&L for plain cement concrete 1:4:8 Type D-2 using 40mm graded stone aggregate as in foundation fillings, mass concrete complete all as specified and as directed by Engineer-in-charge.
25M&L for plain cement concrete M-20 nominal mix using 20 mm graded aggregate as in top layer of hard standing and mass concrete etc complete all as specified and as directed by Engineer-in-charge.
26Finishing the surface of concrete, pavements by brooming complete all as specified and as directed by Engineer-in-charge.
27Forming 12 mm thick expansion joints filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound, Grade 'B' for 150mm thick slab complete all as specified and as directed by Engineer-in-charge.
28Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade 'B' complete all as specified and as directed by Engineer-in-charge.
29Forming construction joint 30mm deep x 10mm wide filled with sealing compound Grade 'B' complete all as specified and as directed by Engineer-in-charge.
30M&L for preparing of new plastered surface and applying two coats of colour wash over a coat of white wash complete all as specified and as directed by Engineer-in-charge.
31Removal of excavation material to a distance not exc 50m and where directed at a level not exc 1.50m above the starting point complete all as specified and as directed by Engineer-in-charge.
32Returning filling in including, spreading, leveling watering and well ramming in layer not exc 25 cm complete all as specified and as directed by Engineer-in-charge. Disconnecting existing tank capcity 500 ltrs setting aside (or lowering if required ) for repair , cleaining, etc and hosting if required reconnecting and re-fixing in postion. (Cleaning reparing etc measured sepratly) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58593251
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 46.18 Lakhs
LAST DATE 07-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair To Roof Treatment Of Bldg No. P-16, P-17, P-43 & P-02 And Provn Of Hard Standing For Heavy Vehs Near Mt (Bldg No P-21) Of Med Regt At Old Amritsar Cantt
Basic Detail
Tender No GE/ASR-83/2026-27
Bidding Type Tender
Location
City Amritsar
State Punjab
Key Dates
Publish Date 18 Nov 2026
Submission Date 07 Dec 2026
Open Date 14 Dec 2026
Finance
Tender Value 46.18 Lakhs
Tender Fee 500
EMD 92500
Exemption Available
Document List
1060d631-9b9a-4a8a-af59-f48ddfbfb1dc.html
BOQ_896830.xls
Tendernotice_1.pdf
TENDER_83.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Dec 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

1060d631-9b9a-4a8a-af59-f48ddfbfb1dc.html

xls

BOQ_896830.xls

pdf

Tendernotice_1.pdf

pdf

TENDER_83.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender