Tender For Supplying And Installation Of Street Light Along With Pole At The Road A) From Starting Point Of Entrance Of Hostel 9 To Entrance Of Hostel 6 B) At The Road Between 33Kv Substation And New Guest House Upto The Junction Point Of Childrens P
Tender Overview
Project Description
Tender for Supplying And Installation Of Street Light Along With Pole At The Road A) From Starting Point Of Entrance Of Hostel 9 To Entrance Of Hostel 6 B) At The Road Between 33Kv Substation And New Guest House Upto The Junction Point Of Childrens Park And Repairing Of Street Lights At The Road Of Sports Complex Area At Nit Silchar. (Re- Tender)
BOQ
| Sl. No. | Item Description |
| 1 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required Above 8.0 metre and upto 10.0 metre |
| 2 | Supplying and embedding following dia hose pipe (medium class as approved by the department) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.32mm |
| 3 | Providing and making steel pole collar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20mm) of specifiedsize and shape including form work,plastering if required,curing etc as required. (volume of pole/ pipe not to bededucted) |
| 4 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required upto 35 sq mm |
| 5 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.upto 35 sq mm cable |
| 6 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with RCC cover plate etc. with charcoal/ coke and salt as required |
| 7 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 A,30KA,FPMCCB |
| 8 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.single pole |
| 9 | single pole and neutral |
| 10 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required100mm dia |
| 11 | Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required. |
| 12 | Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) : 400 mm dia piles |
| 13 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 14 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 16 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. |
| 17 | Supplying and stacking at site: Good earth |
| 18 | Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). |
| 19 | Supplying including fitting and fixing of following size LED Street lights including connection with three core 1.5 sq mm copper wire from the street light junction box where necessarycomplete with all accessories as required.LED street light 90W as approved by the department |
| 20 | Supply of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium f1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable as specified and directed by the deptt. ( Havells/ RPG/CCI/Polycab/ Finolex make) 2 Core A2XWaY A2XFaY 16.00 Sq.mm 3 Core armoured U.G. cable |
| 21 | Supplying the following specification as per IS:2713 : 410 SP hot dip Galvanized Steel tubular pole manufacturing out from electrically welded in 3 (three section having a base plate including providing all required building materials as directed and specified by the deptt.410 SP 23, Length of pole = 8.50 metre., Length of sections, Bottom = 5.00 M, Middle = 1.75 M, Top = 1.75 M, Out side dia. & Thickness Bottom = 165.10 x 4.85 mm, Middle =138.70 x 4.50 mm, Top =114.30 x 3.61 mm |
| 22 | Supply and installation of polycarbonate street light termal box having provision for installation of one DP two SP MCB and having provision for incoming and outgoing cable with necessary clamps nut voltes etc at the street light pole |
| 23 | Supplying including fitting and fixing of Hot Dip galvanised arm bracket for installation of luminaries. Header with top cap 300 mm long pipe of thickness 3 with arrangement to fix on pole top with 3 Nos. of bolts. i Armed of required length size : Single arm bracket 1000mm long . |
| 24 | Supplying and fixing including connections of the Aluminium Lugs for following size of PVC insulated and PVC sheathed/XLPE Aluminium conductor cable of 1.1 KV grade as required.a) 16 Sqmm Three core cable |
| 25 | Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical outdoor type double door, floor mounting compartmentalize panel board for street lights of appropriate size made of 16 SWG1.66 m thick C.R. sheet and 35mm X 35mm X 5mm size angle having 4 no legs at the bottom and C.R. sheet roofing on the top complete painting with 2 coats of Red Oxide metal primer and 2 coats of enamel paint. The panel board is to be erected in 1 : 3 : 6 PCC foundation including excavation of trench and brick soling etc. complete neatly Wiring done with provision for one no 100A 4pole MCCB as incomer and provision for 6nos DP as out going ,one no timer switch,one no 40 amps contractor as specified and directed by the deptt. confirming to IP 65 protection comprising of the following electrical items:1. copper Bus-Bar for carrying 100 Amps 2. Digital 3 Phase Voltmeter - 1 no 3. Digital 3 Phase Ammeter - 1 no4. Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 no 5. Voltmeter & Ammeter Selector Switch - 2 no 6. 2 A Slide fuse unit - 3nos |
| 26 | Supplying and laying of 6SWG GI wire at 0.5 m below at ground level for conductor earth electrode including connection/termination with GI thimble etc as required |
| 27 | Providing and fixing following rating and capacity andpole contractor in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.40 Amps 4 pole contractor |
| 28 | Providing and fixing timer switch in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.for street light Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender