Road Transport and Highways Government Departments Closing in 21 days TDR #58593033

Tender For Special Repairs (Sr) Works For Soil Stabilization Of Collapsed Hillock Along The Nh-748Aa Between Km 10.00 To Km 27.00 Along Chorla Ghat In The State Of Goa During Fy 2026-27.

Issued by Government Departments · goa, Goa
Tender Value
8.41 Crore
Estimated cost
Bid Submission
14 Dec 2026
21 days left
EMD
16.82 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Special Repairs (Sr) Works For Soil Stabilization Of Collapsed Hillock Along The Nh-748Aa Between Km 10.00 To Km 27.00 Along Chorla Ghat In The State Of Goa During Fy 2026-27.

BOQ

Name of Work:- Special Repairs (SR) works for Soil Stabilization of Collapsed hillock along the NH-748AA between Km 10.00 to Km 27.00 along Chorla Ghat in the State of Goa during FY 2026-27.
Sl. No. Item Description
1Supply and fixing 3D net including all cost of labour, material and T&P required for proper completion of work. 3D net is lightweight three dimensional mat made of continuous filaments. 3D net are made of three dimensional structure consisting of UV stabilized non degradable Polypropylene/ Polyethylene/ Nylon or similar polymer fibres that are extruded or heat bonded/tangled at the contact points to provide a dimensionally stable Matrix for soil erosion protection with minimum tensile strength 2 kN/m in length direction & 1 kN/m in cross direction having minimum thickness 6.5mm and minimum mass per unit area 450 gsm as per material specification of IRC-56:2011.
2Supply and Installation of Self driven rock anchor made of 40CR material (equivalient to 41Cr4 as per BS EN 10083-3) with outer dia of 32 mm and inner dia of 18.5 mm, Yield Load Carrying Capacity of Minimum 230 KN in soil / overburden /rock suitable for drilling placing and cement grouting. Installation with all accessories such as 51 mm dia drill bit, couplers, 200*200mm base plate with 10mm thick and nut and bolt complete in all respect.
3Supply and installation of Percussion Driven Zinc-Aluminium Alloy Anchors (Material specification as per BS EN 12844), comprising of minimum 3mm dia wire rope tendon and the tensile strength of wire of the cable should be 1770 N/sqmm having corrosion protection of Zn-Al Coating complete with Self-locking top termination plate made up of suitable corrosion resistant material.
4Supply and fixing of Double Twisted Mesh including all cost of material, labour and T&P required to complete the work in all respect with following properties:a. Mesh type : 10x12, Mesh opening : 100mm X 120mmb. Mesh Wire dia. 2.7/3.7mm (ID/OD), mechanically edged/selvedged with galvanization as perEN 10223-3, and shall have minimum 10 numbers of mesh openings per meter of meshperpendicular to twist.c. Tensile strength (500 Mpa) at a minimum elongation of 10%. The minimum tensile strength of themesh panel must be 32.0 kN/m (+/-5kN/m) in the parallel to the twist direction and 15.5 kN/m in theperpendicular to the twist direction in accordance with the requirements of IS 16014:2018.d. Zinc Coating: The coating weight shall be heavily coated and soft type confirming to therequirements of specifications IS 4826:1972. Adhesion of Zinc Coating: No flakes or crack shall beobserved while testing for adhesion of zinc coating as per IS 4826:1972.* ID/OD - Internal diameter/Outer diameter of Polymer coated wire as per material specification of IS-16014:2018.
5Providing and installing subsurface drainage ploes Semi Perforated PVC pipe (lined with Non-woven Geolextile) of 50mm internal dliameter as per the drawings etc. complete Including the cost of drilling and as directed by Engineer -In -Charge.
6Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. B) PCC Grade M20
7Excavation in Hilly Area in Ordinary Rock by Mechanical Means not Requiring Blasting. (Excavation in hilly area in ordinary rock not requiring ballasting by mechanical means including cutting and trimming of slopes and disposal of cut material with all lift and lead upto 1000 metres )
8Providing & fixing of cautionary sign board of Cautionary/Mandatory/Facility Information sign board made out of retro reflective sheeting conforming to Type XI standards of ASTM D4956 09 & as per IRC-67: 2012 specifications, fully covered over 4mm thick ACP/2mm thick Al supported with back support frame of 25x25x3 mm stainless steel angle of 304 grade. Board Shall be fixed to a vertical post of 80mm dia stainless steel pipe of 3.6 mtr height and firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm etc, 60 cm below ground level. 10 years warranty & a certified copy of three years outdoor exposure report from an independent lab as per IRC 67-2012 for Type XI retro reflective sheeting shall be submitted by the contractor. a)900mm Triangle - Cautionary Sign for Rumble Strip.
9f)300mm x 900mm Rectangle - Hazard Marker Sign for Box culverts/Pipe culverts
10Providing and fixing of standard Metal Delineators per IRC 79:2019 consisting of retro reflective area in white colour using Micro prismatic retro reflective sheeting on each side conforming with IRC 67-2012 and meeting the coefficient of retro reflection values as per Class C table specification. The delineator shall be painted with only black colour powder coat of minimum40 microns thickness, on top of retro reflective sheeting only in white colour shall be pasted on both sides. The structure shall have height not less than 800 mm above ground, width not less than 100 mm and shall extend not more than300 mm below ground while being installed. The delineator shall have grooves across the length to make the reflective sheet vandal proof. The delineator is meant for application on gaps in median, traffic islands, dangerous bends, round abouts, narrow bridges etc or as desired by site engineer. The product shall be provided with 3 year outdoor warranty report tested in India condition as per IRC 67: 2012 requirement. In case of soft ground, a proper foundation may be provided as per approved design. In case foundation is required to be provided, the items of excavation and foundation concrete are required to be measured and paid separately.
11Providing and fixing advance warning speed arrester stud made out of poly carbonate/ABS moulded body and highly reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face with retro reflectance and chromaticity values shall be as given in the detailed specifications and the product shall conform to minimum ASTM D4280 and also meet all the testing conditions of ASTM D4280 listed for RPM (Raised Pavement Marker). The testing and test report shall be as per IRC 35 clause 5.1.2. The speed arrester should be fixed to the road surface using the adhesive recommended by the manufacturer. The length , height and width of the body shall not be less than 150 mm, 9 mm and 90 mm with a tolerance of +/-1 mm. The marker shall support a load of 30000 Kg tested in accordance with ASTM D4280. The area of each side of micro prismatic reflective lens shall not be less than 15.0 sq.cm. The slope or retro – reflective surface shall be 25 + 2 degree to base. It should have one Shank of not less than 25 mm diameter and not less than 40 mm length moulded with the body for anchorage. The certificate confirming to initial CIL value for reflective lens not less than 125 for red lens, 250 for yellow lens & 400 for white lens at 0° entrance and 0.2° observation angle as per ASTM D4280 shall be provided for better visibility & improving road safety for commuters.
12Type - B, Providing and erecting a \\"Thrie\\" metal beam crash barrier \providing and erecting \\"Thrie Beam \\" Crash barrier comprising of following three factory made unites-viz. 1) Thrie Beam 2) Spacer Block 3) Vertical Post. The Thrie beam 3mm thick cold roll formed guard rail raw material Conforming to IS-5986-2011 with minimum Grade 255 & with minimum yield stress of 255 Mpa which is fixed by bolted connection to spacer block C channel of size 150mm* 75mm & 5mm thick, 54.6cm height spaced 2meter centre to centre, fixed to Vertical Post C-channel of size 150mm*75mm&5mm thick cold roll formed section made from HR coils raw material conforming to IS 5986-2011 with minimum Grade 255 & with minimum yield stress of 255MPa, with 85cms free height above road or Ground level, and embedded to 115cms deep in cement concrete block of size 35cm*35*115cm or as directed by Engineer Incharge, assembled & fixed as per drawings of MORTH&H Circular No.RW/NH/33022/1/94 DO/III, dated 24/6/1994 & construction operation as per 811 or revevant MORT&H specifications for Roads & Bridge Works (latest edition). All fittings (bolts, nuts, fasteners, washers etc.) shall be conforming to IS:1367 & IS:1364 & galvanished by hot dip zinc coated process @0.55kg/m2 conforming to relevent IS specifications all etc. complete
13Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.)
14Cautionary/Mandatory/Facility Information Sign Board with SS Structure Providing & fixing of cautionary sign board of Cautionary/Mandatory/Facility Information sign board made out of retro reflective sheeting conforming to Type XI standards of ASTM D4956 09 & as per IRC-67: 2012 specifications, fully covered over 4mm thick ACP/2mm thick Al supported with back support frame of 25x25x3 mm stainless steel angle of 304 grade. Board Shall be fixed to a vertical post of 80mm dia stainless steel pipe of 3.6 mtr height and firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm etc, 60 cm below ground level. 10 years warranty & a certified copy of three years outdoor exposure report from an independent lab as per IRC 67-2012 for Type XI retro reflective sheeting shall be submitted by the contractor. g)600mm x 500mm Rectangle - Chevron Sign
15Solar Blinker 300 mm axony Indian make size 300 mm 12vdc power polycarbonate body led 120 nos clr red/ yellow visibility 500 mtrs day and night 1000 mtrs Battery exide smf 12V 7 ah built in Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58593033
AUTHORITY Government Departments
TENDER VALUE 8.41 Crore
LAST DATE 14-12-2026
Authority
Authority Name Ministry Of Road Transport And Highways
Work Description Tender for Special Repairs (Sr) Works For Soil Stabilization Of Collapsed Hillock Along The Nh-748Aa Between Km 10.00 To Km 27.00 Along Chorla Ghat In The State Of Goa During Fy 2026-27.
Basic Detail
Tender No 2026-27/PWD/WDVII(NH)/ASW/13
Bidding Type Tender
Location
City goa
State Goa
Key Dates
Publish Date 18 Nov 2026
Submission Date 14 Dec 2026
Open Date 16 Dec 2026
Finance
Tender Value 8.41 Crore
Tender Fee 10000
EMD 16.82 Lakhs
Exemption Not Available
Document List
534c179a-6d79-472e-886d-6fc52d91544c.html
BOQ_982015.xls
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf
Tendernotice_4.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Dec 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

534c179a-6d79-472e-886d-6fc52d91544c.html

xls

BOQ_982015.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

pdf

Tendernotice_4.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender