Housing Urban and Rular Development Local Bodies Closing in 3 days TDR #58592925

Tender For annual maintenance Of Internal Water Supply Scheme In Sector- 6,7,8,9,10,11,11 Extn. Pwd Bandr Store And Workshop Land, Diwankhana District Shopping Centre At Jind (2026-27). Repairing The Main Sewerage Rising Line With New 400Mm And 1200M

Issued by Local Bodies · Jind, Haryana
Tender Value
6.44 Lakhs
Estimated cost
Bid Submission
24 Nov 2026
3 days left
EMD
14000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jind → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for annual maintenance Of Internal Water Supply Scheme In Sector- 6,7,8,9,10,11,11 Extn. Pwd Bandr Store And Workshop Land, Diwankhana District Shopping Centre At Jind (2026-27). Repairing The Main Sewerage Rising Line With New 400Mm And 1200Mm Dia Reinforced Cement Concrete Np3 Pipes Of Sector-6, 7, 8 And 9 At Disposal Sector-9, Jind And All Other Works Contingent Thereto. (Including One Year Maintenance And Defect Liability Period Free Of Cost)

BOQ

Name of Work:- A/MTC. OF INTERNAL WATER SUPPLY SCHEME IN SECTOR- 6,7,8,9,10,11,11 EXTN. PWD BandR STORE AND WORKSHOP LAND, DIWANKHANA DISTRICT SHOPPING CENTRE AT JIND (2026-27). `Repairing the main sewerage Rising line with new 400mm and 1200mm dia RCC NP3 pipes of Sector-6, 7, 8 and 9 at Disposal Sector-9, Jind and all other works contingent thereto`. (Including One year maintenance and defect liability period free of cost)
Sl. No. Item Description
1[11.5.1]12 mm cement plaster of mix : 1. 1:2 (1 cement: 2 fine sand)
2[11.52]Cement rendering on plaster 1 mm thick
3[15.1.2.1]Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material as per clause 304 of MORTandH specifications Ordinary soil 2.1. Mechanical Means Depth up to 3 m
4[15.1.2.2]Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material as per clause 304 of MORTandH specifications Ordinary soil 2.2. Mechanical Means Depth 3 m to 6 m
5[15.1.2.3]Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material as per clause 304 of MORTandH specifications Ordinary soil 2.3. Mechanical Means Depth above 6m
6[21.28]Providing and fixing steel bar embedded plastic steps of size 263mm x 165mm of orange colour, confirming to specification in pump chambers, manholes etc., having minimum 3mm thick polypropylene polymer confirming to is:10910 encapsulated on 12mm dia ribbed steel bars per IS :1786. The rate include cost of setting the same to correct lines and levels duly embedded in 1:2:4 cement concrete including carriage, loading, uploading, stacking, handling, re-handling etc., complete in all respect to the satisfaction of Engineer-in-charge
7[21.93.2]Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 2. Type:- Extra Heavy Duty Set (EHD-20) 560MM Clear Opening
8[21.95.10]Providing lowering cutting jointing and testing RCC pipe class NP3 as per IS-458-2003 with spigot and socketed joints manufactured with ISI marked sulphate resistance cement as per ISI 12330 with rubber rings ISI marked antiternmite as required at site in to trenches for all depths and laying out the same to correct alignment gradients and levels including dressing and trimming and cutting of concrete beds and side of trenches, if required jointing with rubber rings in trenches and jointing with 1:3/2 cement sand mortar and with end dowels filled with 1:3/2 cement sand mortar and finishing the joints at an angle of 45 degree with faces of spigot of socket joints cutting and finishing the cut surface to a uniform finish etc. as fully described in item No. 21.38, item 21.44, item 21.45, and item 21.46 including cartage loading and unloading complete in all respects. the internal diametric of the sewer being: 10. 1200 mm
9[21.95.2]Providing lowering cutting jointing and testing RCC pipe class NP3 as per IS-458-2003 with spigot and socketed joints manufactured with ISI marked sulphate resistance cement as per ISI 12330 with rubber rings ISI marked antiternmite as required at site in to trenches for all depths and laying out the same to correct alignment gradients and levels including dressing and trimming and cutting of concrete beds and side of trenches, if required jointing with rubber rings in trenches and jointing with 1:3/2 cement sand mortar and with end dowels filled with 1:3/2 cement sand mortar and finishing the joints at an angle of 45 degree with faces of spigot of socket joints cutting and finishing the cut surface to a uniform finish etc. as fully described in item No. 21.38, item 21.44, item 21.45, and item 21.46 including cartage loading and unloading complete in all respects. the internal diametric of the sewer being: 2. 400 mm
10[6.1.6]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
11[6.1.7]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 7. 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size)
12[6.14.1]Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
13[6.29.2]Centering and shuttering including strutting, propping etc. and removal of form work for : 2. Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
14[6.30.2]Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
15[6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more
16[7.20.1]Brick work with common burnt clay modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand)
17[7.20.2]Brick work with common burnt clay modular bricks of class designation 10.5 in foundation and plinth in: 2. Cement Mortar 1:6 (1 cement : 6 coarse sand)
18Hiring of tractor with burma including cost of services of operating staff, lubricating oil, diesel/Petrol, other consumables for running the Tractor with burma set complete in all respect for sucking and disposal of sewerage water complete in all respect including cost of material, labor, carriage, loading-unloading, excluding GST, other charges etc. as per the satisfaction of Engineer-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58592925
AUTHORITY Local Bodies
TENDER VALUE 6.44 Lakhs
LAST DATE 24-11-2026
Authority
Authority Name Haryana Urban Development Authority
Work Description Tender for annual maintenance Of Internal Water Supply Scheme In Sector- 6,7,8,9,10,11,11 Extn. Pwd Bandr Store And Workshop Land, Diwankhana District Shopping Centre At Jind (2026-27). Repairing The Main Sewerage Rising Line With New 400Mm And 1200Mm Dia Reinforced Cement Concrete Np3 Pipes Of Sector-6, 7, 8 And 9 At Disposal Sector-9, Jind And All Other Works Contingent Thereto. (Including One Year Maintenance And Defect Liability Period Free Of Cost)
Basic Detail
Tender No 20264E339A6B 07D9 43BC A234 20A10EE098DB259HSV
Bidding Type Tender
Location
City Jind
State Haryana
Key Dates
Publish Date 18 Nov 2026
Submission Date 24 Nov 2026
Open Date 25 Nov 2026
Finance
Tender Value 6.44 Lakhs
Tender Fee 500
EMD 14000
Exemption Available
Document List
BOQ_641271.xls
de58535c-fc3b-4130-a327-429000a803cf.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Nov 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_641271.xls

html

de58535c-fc3b-4130-a327-429000a803cf.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender