Tender For Providing Replacement Of Electric Traction 8 Passanger One Lift (U.G + G.F.+ F.F + S.F + T.F + F.F) With Necessary Eelctrical Installation For Zilla Parishad Building At Parbhai. Tq And Dist. Parbhani.
Tender Value
18.82 Lakhs
Estimated cost
Bid Submission
23 Nov 2026
2 days left
EMD
18829
Bank guarantee accepted
Document Fee
5200
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Parbhani → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing Replacement Of Electric Traction 8 Passanger One Lift (U.G + G.F.+ F.F + S.F + T.F + F.F) With Necessary Eelctrical Installation For Zilla Parishad Building At Parbhai. Tq And Dist. Parbhani.
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and erecting 20mm dia. corrugated flexible polypropylene conduit . DSR I.No. 1.2.1 (new). |
| 2 | Supplying and erecting HMS PVC conduit 25 mm dia.withPVC accessories on wall /ceiling as per specification No: WGMA/ CON, para no. 1.1.1. DSR I.No. 1.2.7. |
| 3 | Supplying & erecting mains with 2x1.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/BW. DSR I.No. 1.3.1 |
| 4 | Supplying & erecting mains with 1 x1.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/BW. DSR I.No. 1.3.1 |
| 5 | Supplying and erecting Ceiling rose / Batten holder / Slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6A. erected on filled polypropylene board or polished double wooden block/ PVC junction box. DSR I.No. 1.5.7. |
| 6 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. DSR I.no. 1.6.1. |
| 7 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete . DSR I.No. 1.6.10 |
| 8 | Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. DSR I.no. 1.6.23. |
| 9 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected. DSR I.No. 1.6.29 |
| 10 | Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW. DSR I.No. 1.7.19 |
| 11 | Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing andrequired accessories as per specification No: WG-PW/SW. DSR I.No. 1.7.20 (NEW). |
| 12 | Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/ CW. DSR I.no.1.7.26. |
| 13 | Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. DSR.I.No. 2.1.15 |
| 14 | Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life ofminimum 25000 hrs. with overheating protection with 2 years warranty. DSR I.No. 2.1.22.(NEW) |
| 15 | Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22 / E-27 base. DSR I.No. 2.8.11. |
| 16 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete. DSR I.No. 2.10.14. |
| 17 | Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF. DSR I.No. 2.10.21. |
| 18 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB. DSR I.No. 5.3.3. |
| 19 | Supplying, erecting & marking DPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB. DSR I.No. 5.3.7 |
| 20 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB. DSR I.No. 5.3.11. |
| 21 | Supplying, erecting and marking double pole isolator only switch version of miniature circuit breaker of 40A with required wiring connections and lugs etc. in provided distribution board. DSR I.No. 5.3.14. |
| 22 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB. DSR I.No. 5.4.8. |
| 23 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB /RCCB /RCBO complete erected on angle iron/GI frame. DSR I.no. 5.4.13. |
| 24 | Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB. DSR I.No. 5.6.1 |
| 25 | Supplying, erecting & commissioning 4 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB. DSR I.No. 5.6.5. |
| 26 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU DSR I.No. 7.2.8. |
| 27 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU. DSR I.No. 7.2.33. |
| 28 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materils, testing & recording the results as per specification no. EA-EP. DSR I.No. 9.1.1. |
| 29 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EA-EP. DSR I.No. 9.2.8. |
| 30 | SITC of Electric Traction Passenger Lift with -DSR I.No. 17.1.3· Rated capacity :- 8 Passenger/544Kg · Floors :- G+1 floor (2 Stops/2 Landings) · Travel :- 3 to 4.2 mtrs· Location of Lift Machine:- MR/MRL · Rated speed :- 1.0 mps VS Car/Landing door clear opening of 800 mm wide x 2000 mm high· Clear Car size of ......mm wide x ......mm deep x 2250mm high · Lift shaft available having clear size of ......mm wide x ......mm deep,......mm Pit depth, ………mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade olid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of dequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.ace plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.· Lift controller based on microprocessor/ PLC with VVVF Drive havingclosed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle ofminimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. ther mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.· Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.· General: - Job includes entire procedure of obtaining all necessary erection permissions & \\"License to Work the Lift\\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. A2 For Lift having 800 mm wide x 2000 mm high clear entrance in 1.5 mm thick SS 304 solid (non cladded) landing door (two panel). this includes all necesary accessories like LOP's with UP/DN buttons-arrows - indicators, extension of guide rails, shaft wiring with trunking, trvelling cables, main hoisting ropes/belts and OSG rope landing doors with all accessories etc necessary for the normal safe functioning of lift installation complete. B1 For Full Collective control system, add as below. 1. For Lift travelling above First floor & up to Sixth floor. DSR I.no. 17.1.3 |
| 31 | Dismantling the existing 4 to 7 Passenger lift of all types travelling G+1 floors (2 Landings/2Stops) having with auto/manual operated doors for lift car & all landings with door frames, guide rails, controller, wiring buffers, Lift Machine, ropes complete with all allied accessories of Lift and making the site clear in all respect complete with refilling the holes with cement mortar & making the site as original this job includes transportation of the dismantled material up to division/section store and handing over to the section engineer/store keeper incharge complete. DSR I.No. 17.2.1. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysNov 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender