Tender For State Plan-State Plan 2026-27- Construction/Renovation Of Civil Structures By Kwa-Construction Of Office Building For P H Section Kottakkal Under Neath The Newly Constructed 16 Ll Capacity Ohsr At Parappur -General Civil Work
Tender Overview
Project Description
Tender for State Plan-State Plan 2026-27- Construction/Renovation Of Civil Structures By Kwa-Construction Of Office Building For P H Section Kottakkal Under Neath The Newly Constructed 16 Ll Capacity Ohsr At Parappur -General Civil Work
BOQ
| Sl. No. | Item Description |
| 1 | Structural Work Flooring and Painting |
| 2 | 50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. |
| 3 | 50.6.1.7:Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15 cm in : CM 1:6 ( 1 cement : 6 coarse sand ) etc complete |
| 4 | 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 5 | 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 6 | 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 7 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 8 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 9 | 9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood |
| 10 | 11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 11 | 11.38:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of Ist quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete. |
| 12 | 8.31:Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 13 | 9.117.1:Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm |
| 14 | 9.118.3:Providing and fixing to existing door frames25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762 mm x 25 mm or less as per requirement with and average wall thickness of 1 mm ( ± 0.3 mm). PVC foam end cap of size 23x10 mm area provided on both vertical edges to ensure the overall thickness of 25 mm. An M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end -cap of the size 25 mm x 11 mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufacturer,s specification and direction of Engineer-in-charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places. |
| 15 | 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 16 | 7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 17 | 2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 18 | 4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 19 | 17.9.1:Providing and fixing kitchen sink with C. I brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required:White glazed fire clay kitchen sink of size 600x450x250 mm |
| 20 | 9.5.1.1:Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.Second class teak wood35 mm thick shutters |
| 21 | 9.103:Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc . complete. |
| 22 | 9.53:Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 23 | 50.9.15.1:Supplying and fixing 200 mm Aluminium aldrop |
| 24 | 50.9.15.2:Supplying and fixing 300 mm Aluminium aldrop |
| 25 | 9.97.1:Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm |
| 26 | 9.97.2:Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:250x10 mm |
| 27 | 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 28 | 13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 29 | Steel tress work |
| 30 | 10.16.3:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes |
| 31 | 12.1.3:Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/m2 |
| 32 | Electrical Work |
| 33 | OD72116/2026-2027:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B (Data from DAR E&M 1.10.2) |
| 34 | OD72128/2026-2027:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) (Data from DAR E&M 1.27.2) |
| 35 | OD72169/2026-2027:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm) (Data from DAR E&M 1.27.3) |
| 36 | OD72170/2026-2027:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) (Data from DAR E&M 1.27.4) |
| 37 | OD72171/2026-2027:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet (Data from DAR E&M 1.24.4) |
| 38 | OD72173/2026-2027:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch (Data from DAR E&M 1.24.1) |
| 39 | OD72174/2026-2027:1 or 2 Module (75mmX75mm) Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. (Data from DAR E&M 1.27.1) |
| 40 | OD72175/2026-2027:Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asvrequired.15/16 amp switch (Data from DAR E&M 1.24.3) |
| 41 | OD72176/2026-2027:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet (Data from DAR ELE 1.24.5) |
| 42 | OD72177/2026-2027:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (Data from DAR ELE 1.25) |
| 43 | OD72179/2026-2027:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm (Data from DAR ELE 1.21.1) |
| 44 | OD72180/2026-2027:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm (Data from DAR ELE 1.21.2) |
| 45 | OD72182/2026-2027:Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x2.5 sq.mm (Data from DAR ELE 1.17.12) |
| 46 | OD72183/2026-2027:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x4 sq.mm (Data from DAR ELE 1.17.21) |
| 47 | OD72184/2026-2027:Single pole Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Data from DAR ELE 2.10.1) |
| 48 | OD72668/2026-2027: 40 amps Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Data from DAR ELE 2.12.1) |
| 49 | OD72669/2026-2027:63 amps Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Data from DAR ELE 2.15.3) |
| 50 | OD72673/2026-2027:63 amps Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.. (Data from DAR ELE 2.13.2) |
| 51 | OD72672/2026-2027:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. (Data from DAR ELE 2.1.2) |
| 52 | OD72675/2026-2027:Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way (4+36), Double door (Data from DAR ELE 2.5.3) |
| 53 | OD72679/2026-2027:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.(Data from DAR ELE 5.4) |
| 54 | OD72678/2026-2027:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/coke and salt) as required. (Data from DAR ELE 5.1) |
| 55 | OD72680/2026-2027:3.15 mm copper conductor ( 10 SWG) Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required. (Data from DAR ELE 90.16.1.3) |
| 56 | OD72681/2026-2027:1200 mm 1X20W LED Lamp with box type fixture Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down rod Supply, conveyance, installation, testing and commissioning the light fittings of following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required. (Data from DAR ELE 90.3.24.3) |
| 57 | OD72686/2026-2027:Supplying and fixing 20-Watt LED light fitting, energy-efficient and long-lasting, suitable for decorative applications. The luminaire shall operate on 240 Volts AC supply and produce cool white light with a luminous efficacy conforming to BIS/IEC standards. The fitting shall be compact in design with a body length of approximately 120 mm and constructed using high-grade thermoplastic or aluminium housing with adequate heat dissipation. The LED chip shall have a minimum rated life of 25,000 hours with power factor ? 0.90 and total harmonic distortion (THD) ? 10%. The fixture shall include necessary mounting brackets, and accessories for surface/concealed installation, complete as per manufacturer?s specifications and the direction of the Engineer-in-charge |
| 58 | OD72688/2026-2027:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) (Data from DAR ELE 90.15.4.2) |
| 59 | OD72696/2026-2027:Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 starrated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class ofinsulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit,safety rope, copper winding, Power Factor not less than 0.9, Service Value(CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (toleranceas per IS : 374-2019), THD less than 10%, remote or electronic regulator unit forspeed control and all remaining accessories including safety pin, nut bolts,washers, temperature rise=75 degree C (max.), insulation resistance more than 2mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc.complete as required. (Data from DAR ELE 19.1) |
| 60 | OD72697/2026-2027:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. (Data from ELE 90.15.4.2) |
| 61 | OD72700/2026-2027:Conveyance, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan |
| 62 | OD72703/2026-2027:Supplying and fixing 63, HRC Fuse with HRC Fuse link with connections, in existing meter board |
| 63 | Plumbing and Sanitation Works |
| 64 | 17.7.8:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers |
| 65 | 18.53.1:Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore |
| 66 | 17.2.1:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid |
| 67 | 50.17.1.4:Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. |
| 68 | 50.17.1.1:Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 69 | 50.17.1.3:Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 70 | 18.50.1:Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore |
| 71 | OD70593/2026-2027:Providing and fixing 15mm PVC tap |
| 72 | 17.29:Providing and fixing 100 mm sand cast Iron grating for gully trap. |
| 73 | 50.18.8.2.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chased and making good the wall etc. 20 mm pipe 12 Kgf/cm2 |
| 74 | 50.18.8.3.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2 |
| 75 | 50.18.8.5.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2 |
| 76 | 50.18.8.7.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc 63 mm pipe 4 kgf/ cm2 |
| 77 | 50.18.8.9.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC Solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 110 mm pipe 4 kgf/cm2 |
| 78 | 18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 79 | OD70599/2026-2027:Supply and installation of submersible pump set working in single-phase/three phase, suitable for vertical installation in open wells, borewells, or sumps, and shall operate efficiently under submerged conditions. The pump set shall be capable of delivering a discharge of not less than 30 to 50 litres per minute with a total head up 30 metres, depending on site conditions. The pump shall be equipped with a water-cooled, copper-wound motor with built-in thermal overload protection. The pump construction shall include a corrosion-resistant stainless steel or cast iron body, non-return valve, and durable impellers made of thermoplastic or metal as per IS standards. The pump shall be suitable for connection with a 1" to 1.25" delivery pipe and shall include all necessary accessories for complete installation and operation. The unit must conform to relevant IS specifications, and the bidder shall provide product catalogues, test certificates, warranty details ,and manufacturer?s compliance certificate. The pump set shall be suitable for domestic water supply, overhead tank filling, including cost of pumpset, starter, cable and HDPE delivery pipe up to 15 mtr. as per the site condition |
| 80 | 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 81 | 50.6.7.1:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc. |
| 82 | 4.3.2:Centering and shuttering including strutting, propping etc. and removal of form work for:Retaining walls, return walls, (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. |
| 83 | 5.22.1:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars |
| 84 | 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 85 | 9.97.5:Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm |
| 86 | Cement concrete Interlock Arrangement |
| 87 | 16.68:Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 88 | Furnishing and interior |
| 89 | 9.168:Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge.(Payment of providing and fixing auto closing hinges shall be paid separately) |
| 90 | 9.114.1:Providing and fixing magnetic catcher of approved quality in cupboard/ward robe shutters, including fixing with necessary screws etc. complete.Triple strip vertical type |
| 91 | 9.172:Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per directions of Engineer- in-charge. |
| 92 | 9.79.1:Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete.40 mm |
| 93 | 9.80:Providing and fixing 50 mm bright finished brass cup board or wardrobe knob of approved quality with necessary screws. |
| 94 | 9.81.1:Providing and fixing bright finished brass handles with screws etc. complete:125 mm |
| 95 | 9.171:Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge. |
| 96 | OD92228/2026-2027:Executive high back revolving chair (spl. type) (Neck support) |
| 97 | OD92229/2026-2027:Revolving chair medium back with push back |
| 98 | OD92227/2026-2027:Plastic Moulded Armed Chair Good Quality-Nilkamal |
| 99 | Aluminium Doors and window |
| 100 | 21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) |
| 101 | 21.12.2:Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0mm thick & 2100 mm long with S.S. screws etc. complete as per direction of Engineer -in-Charge.Powder coated minimum thickness 50 micron aluminium tubular handle bar |
| 102 | 21.17:Providing and fixing anodised aluminium grill ( anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.(Only weight of grill to be measured for payment ). |
| 103 | 21.19.2:Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structuralnon sag elastomeric PU sealant over backer rod of approved quality as perarchitectural drawings and direction of Engineer-in-charge complete,complying to ASTM C920, DIN 18540-F & ISO 11600Upto 10 mm depth and 10 mm width |
| 104 | 21.2.2:Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides |
| 105 | 21.3.2:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm) |
| 106 | 21.4.1:Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors, embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer -in- Charge.With stainless steel cover plate minimum 1.25 mm thickness |
| 107 | 21.16.3:Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-Charge.Polyester powder coated minimum thickness 50 micron aluminium |
| 108 | Inverter and battery |
| 109 | OD71932/2026-2027:Providing and fixing 3000VA/25.6 V- 2400 watts, of approved make, suitable for uninterrupted power supply applications. support pure sine wave output, and include advanced microprocessor-based control, automatic changeover, overload protection, short-circuit protection, and battery deep-discharge protection. The unit shall have LED/LCD indicators for status and fault display. Installation shall include transporting to site, mounting in the designated location, connecting to the existing battery bank and load circuits, and testing for proper operation as per manufacturer?s guidelines. The rate shall include the cost of the UPS, all accessories, cables, connectors, tools, consumables, and all labour charges required for complete installation and commissioning to the satisfaction of the Engineer-in-Charge. |
| 110 | OD71933/2026-2027:Providing and fixing 100AH / 25.6V LiFePO (Lithium Iron Phosphate) battery, designed for energy storage applications, with a nominal capacity of 2.5 units (kWh) per battery. The battery shall have high cycle life, deep discharge capability, inbuilt Battery Management System (BMS) for overcharge, over-discharge, short-circuit, and temperature protection, and be housed in a robust casing suitable for indoor installation. The rate shall be inclusive of the cost of the battery, all necessary interconnecting cables, lugs, terminals, tools, accessories, consumables, and all labour charges required for complete installation and testing to the satisfaction of the Engineer-in-Charge. |
| 111 | Networking |
| 112 | OD71943/2026-2027:Providing and fixing D-Link Cat6 cable in suitable lengths for data networking, laid through 25 mm medium class PVC conduit conforming to ISI standards, including all necessary bends, junction boxes, couplers, saddles, and other required accessories. The rate shall be inclusive of the cost of all materials, accessories, tools, consumables, and all labour charges required for complete execution of the work to the satisfaction of the Engineer-in-Charge. |
| 113 | OD71949/2026-2027:Providing and fixing network wall mount box of approved make and size, suitable for housing networking equipment.The rate shall include the cost of the wall mount box, all accessories, tools, fasteners, consumables, and all labour charges for complete installation to the satisfaction of the Engineer-in-Charge. |
| 114 | OD71944/2026-2027:Providing and fixing TP-Link Gigabit 24-Port Network Switch of approved model, suitable for high-speed Ethernet networking, conforming to IEEE 802.3 standards.The rate shall include the cost of the switch, all necessary accessories, tools, consumables, and all labour charges required for complete installation to the satisfaction of the Engineer-in-Charge. |
| 115 | OD71946/2026-2027:Providing and fixing factory-made patch cord of 1.5 metre length, Cat6, of approved make.The rate shall include the cost of the patch cord, all accessories, tools, consumables, and all labour charges required for complete connection and testing to the satisfaction of the Engineer-in-Charge. |
| 116 | OD71948/2026-2027:Providing and fixing RJ-45 connectors of D-Link make, Cat6 type, suitable for use with Cat6 UTP cables, conforming to relevant ISO/IEC and TIA/EIA standards. The rate shall be inclusive of the cost of connectors, all necessary tools, accessories, consumables, and all labour charges required for complete installation to the satisfaction of the Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender