Tender For Construction Of Sports Hall In Ward 24 Mc Palwal (D-Plan 2026-27).
Tender Value
11.07 Lakhs
Estimated cost
Bid Submission
25 Nov 2026
2 days left
EMD
22147
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Faridabad → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Sports Hall In Ward 24 Mc Palwal (D-Plan 2026-27).
BOQ
| Sl. No. | Item Description |
| 1 | HSR Item 20.71.2-Supply, erection, testing of Ceiling fans ISmarked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 2. 56\\" (1400mm) |
| 2 | HSR Item 6.16-Reinforced cement concrete work in beams,suspended floors, roofs having slope up to 15° landings,balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level up to floorfour level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 3 | HSR Item 6.34.6-Steel reinforcement for R.C.C. work, wherenot included in the complete rate of RCC, includingstraightening, cutting, bending, placing in position, binding,wastage, overlaps, welded joints, spacer bars, chairs, stays,hangers and annealed steel wire etc. complete in all respectabove plinth level Note:- Reinforcement shall be measured inlength including hooks, if any, separately for differentdiameters as actually used in work , excluding overlaps.Wastage, overlaps, couplings, welded joints, spacer bars,chairs, stays, hangers and annealed steel wire or othermethods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of gradeFe-500D or more. |
| 4 | HSR Item 7.22.2-Brick work with common burnt clay nonmodular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 2. Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 5 | HSR Item 11.9.2-15 mm cement plaster on rough side ofsingle or half brick wall of mix: 2. 1:6 (1 cement: 6 coarsesand) |
| 6 | HSR Item 11.59-Providing and applying plaster of paris puttyof 2 mm thickness over plastered surface to prepare thesurface even and smooth complete. |
| 7 | HSR Item 11.60-Providing and applying white cement basedputty of average thickness 1 mm, of approved brand andmanufacturer, over the plastered wall surface to prepare thesurface even and smooth complete. |
| 8 | HSR Item 6.30.20-Centering and shuttering includingstrutting, propping etc. and removal of form for 20. Suspended floors, roofs, landings, balconies and access platform withwater proof ply 12 mm thick |
| 9 | HSR Item 9.14.1-Providing and laying brick tiles over mumtyroofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand)mixed with 2% of integral water proofing compound by weightof cement, over 12 mm layer of cement mortar 1:3 (1 cement :3 fine sand) and finished neat: 1. With common burnt clay non-modular brick tiles of class designation 10 |
| 10 | HSR Item 9.57.2-Providing and fixing on wall faceUnplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion, (i) Singlesocketed pipes. 2. 110 mm diameterHSR Rate(Rs.) 200.00 Through Rate |
| 11 | HSR Item 12.7.1.2-Providing and fixing panelled or panelledand glazed shutters for doors, windows and clerestorywindows, including ISI marked M.S. pressed butt hingesbright finished of required size with necessary screws,excluding panelling which will be paid for separately, allcomplete as per direction of Engineer-in-charge. (Note:- Butthinges and necessary screws shall be paid separately) 1.2.Second class teak wood30 mm thick shutters |
| 12 | HSR Item 12.3.3.1.2-Providing and fixing wooden mouldedbeading to door and window frames with iron screws, plugsand priming coat on unexposed surface etc. complete : 3.1.2. 2nd class teak wood 50 x 20 mmHSR Rate(Rs.) 154.00 Through Rate |
| 13 | HSR Item 23.2.1.2-COPPER WIRING WITH MODULARSWITCHES IN MS CONDUITS (SURFACE/RECESS) 1.2.Wiring for Light/Fan/call bell point with modular typeswitch/socket and GI box, Modular type face plate etc in 1.5sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group BHSR Rate(Rs.) 747.00 Through Rate |
| 14 | HSR Item 23.2.4.2-COPPER WIRING WITH MODULARSWITCHES IN MS CONDUITS (SURFACE/RECESS) 4.2.Wiring in MS conduit system for 3-pin 5amp. Plug point byusing 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 SqmmFRLS copper wire , including providing 1 no 5/6 Amp 3/5 pinModular type socket and 1 no 5/6 Amp Modular type switchrequired GI Box ,modular face plate etc complete as requiredGroup BHSR Rate(Rs.) 1179.00 Through Rate |
| 15 | HSR Item 10.51-Providing and fixing granite stone in allshades 15mm to 18 mm thick in skirting /dado, risers ofsteps, pillars and wall facing, laid in any pattern as specifiedover base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc.HSR Rate(Rs.) 2534.00 Through Rate |
| 16 | HSR Item 23.22.4.2-MCCB ,DISTRIBUTION BOARDS,MCB`s, RCCB`s, CHANGE OVER etc. 4.2. Supply anderection of double door sheet steel enclosure distributionboard suitable for MCBS and ELCBS etc. recessed in wallincluding bonding to earth with all labour and materialrequired to complete the job in all respect up to the entiresatisfaction of the Engineer-in-Charge of the work. SPN DBDouble Door 8 way ( 2 incoming and 6 outgoing)HSR Rate(Rs.) 1406.00 Through Rate |
| 17 | HSR Item 23.28.9.4-Supplying, installation, Testing andCommissioning of LED surface mounted Batten light offollowing body material and construction as per IS : 10322with driver (Replaceable) as per the requirement with Driverefficiency )85% ,Operating voltage AC 140-270 Volt, freq50/60 hz, Operating temp range -15 deg to 40 deg centigrade,internal surge protection of 2.5 KV with Short and Open circuitprotection ,THD ( 10% , P. F.=0.95, IP20, CRI )80, Flickerfree, (flicker should be below 5 %), life time (LED,Driver andelectrical circuitary), of minimum 50000 Burning Hours with ,70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (3, Maximum powerconsumption should not more than the specified rating andFixture shall be of relevant BIS standard and trade markcertificate ( T.C.). Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in allrespect i/c connections with 1.5 sq mm FRLS, PVC insulatedcopper conductor single core cable and earthing etc. asrequired with Minimum 5 year OEM warranty. System lumenefficacy =105 (120 lm/Watt output . LM79 and LM80 Testreport from NABL lab for all testing required for LED fixturesas per BIS shall be submitted. Shape size and CCT shall beas approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminum housing suchthat LED junction temperature shall not rise above 90°C). 4.Powder coated die cast / Extruded aluminium Body(Thickness >= 1.20 mm) 40 WattHSR Rate(Rs.) 580.00 Rate |
| 18 | HSR Item 12.50.2-Providing and fixing M.S. grills of requiredpattern in frames of windows etc. with M.S. flats, square orround bars etc. including priming coat with approved steelprimer all complete. 2. Fixed to openings /wooden frames withrawl plugs screws etc.HSR Rate(Rs.) 105.00 Through Rate |
| 19 | HSR Item 11.96.1-Finishing walls with Premium AcrylicSmooth exterior paint with Silicone additives of requiredshade: 1. New work (Two or more coats applied @ 1.43litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)HSR Rate(Rs.) 85.00 Through Rate |
| 20 | HSR Item 26.58.1-Supply and installation of garden bench 1.Chair type garden bench with L-shaped sides made ofreinforced concrete (M30), thickness 100 mm, overall height1000 mm, base width 620 mm. Back and seat shall consist of 5 Nos. reinforced concrete planks 1500 mm x 100 mm x 50 mm one plank 1500 mm x 200 mm x 50 mm. Seating height of the bench shall be 450 mm. The bench shall be fixed with nuts on concrete mount, all holes sealed after assembly and installation. All materials required to be as per BIS specifications. |
| 21 | HSR Item 13.29.2-Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer usingstructural steel etc. as required. 2. In gratings, frames, guardbar, ladder, railings, brackets, gates and similar works |
| 22 | HSR Item 13.41-Providing and fixing stainless steel ( Grade304) railing made of Hollow tubes, channels, plates etc.,including welding, grinding, buffing, polishing and makingcurvature (wherever required) and fitting the same withnecessary stainless steel nuts and bolts complete, i/c fixingthe railing with necessary accessories and stainless steeldash fasteners , stainless steel bolts etc., of required size, onthe top of the floor or the side of waist slab with suitablearrangement as per approval of Engineer-in-charge, (forpayment purpose only weight of stainless steel members shallbe considered excluding fixing accessories such as nuts,bolts, fasteners etc.) |
| 23 | HSR Item 23.28.20.4-Supplying, installation, Testing andCommissioning of Smart Street light LED fixture, powdercoated pressure die cast aluminum body with built in orseparate driver as per the requirement ( ( 700ma), Inputvoltage: 140-270 Volt AC, freq 50/60 hz, Operating temprange -15 deg to 50 deg centigrade, internal surge protectionof 5 KV L,N,E as per IEC 61000- 4-5, Driver efficiency)85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95,IP-66,IK-08, CRI )80 , under voltage and over voltageprotection, EMI- EMC as per CISPR-15, lenses for beamangle as per IESNA type I/II/III as per the width of the roadand the project requirement., suitable to fit in up to 65mm diapipe, life time of minimum 50000 Burning Hours with 70% ofinitial Lumen maintained till life ends as per LM80extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K /5700°K /6000°K/6500°K(As per ANSI Bin) , Maximum powerconsumption should not more than the specified rating andFixture shall be of relevant BIS standard complete in allrespect i/c connections with 1.5 sq mm FRLS, PVC insulatedcopper conductor single core cable and earthing etc. asrequired with Minimum 5 year OEM warranty. System lumenefficacy )135 lm/Watt output . LM79 and LM80 Test reportfrom NABL lab for all testing required for LED fixtures as perBIS shall be submitted. Shape size and CCT shall be asapproved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminum housing suchthat LED junction temperature shall not rise above 90°C).1. Control and monitor LED luminaries with bi directionalcontrol ( Status, Fault, Alarm, dimming level, wattage, energy)2. to measure voltage, current, power, power factor, apparentenergy, active energy, operating hours.3. Inbuilt ambient light sensor, motion sensor based onPassive Infra Red (PIR).4. Wi-Fi LoRA/Zigbee/Power line with Ethernet network basedIOT feature as per site requirement or engineer in charge.5. should be controlled through auto/ manual6. Programmable level of not less than 48 different lightintensity settings,7. Inbuilt repeater and relay signals function to othercontrollers 4. 90 WattHSR Rate(Rs.) 3710.00 Rate |
| 24 | HSR Item 24.4.2.2-STREET LIGHT 2.2. Supply and erectionof GI bracket made of 32 mm dia medium class GI pipe,having 15 deg angle from horizontal, suitable for fixing on topof Street Light pole 90 cm long, with 20 cm high suitable sizepole capHSR Rate(Rs.) 486.00 Through Rate |
| 25 | HSR Item 24.14.21-LT CABLES (Aluminium Conductor,Armoured and Unarmoured) PROVIDING& ERECTION/LAYING OF PVC/ XLPE INSULATED UNDERGROUNDALUMINIUM CONDUCTOR UNDERGROUND CABLEONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALLRESPECT WITH NECESSARY CONNECTION UPTO THEENTIRE SATISFACTION OF ENGINEER IN CHARGE OFTHE WORK 21. 16 Sq mm 3 core (UnArm.)HSR Rate(Rs.) 122.00 Through Rate |
| 26 | HSR Item 9.51.1-Providing and fixing false ceiling at all heightincluding providing and fixing of framework made of specialsection, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts and bolts of required size and other end of angle hanger fixed with intermediate G.I channels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with thehelp of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, includingj ointing and finishing to a flush finish of tapered and squareedges of the board with recommended jointing compounds,jointing tapes, finishing with jointing compounds in threelayers covering up to 150mm on both sides of joints and twocoats of primer suitable for boards, all as per manufacture`sspecification and also including the cost of making opening forlight fittings, grills, diffusers, cut outs made with frame ofperimeter channels suitably fixed, all complete as perdrawings, specification and direction of the Engineer in chargebut excluding the cost of painting with: 1. 8 mm thick CalciumSilicate Board made with Calcareous & Siliceous materialsreinforced with cellulose fibre manufactured throughautoclaving process |
| 27 | HSR Item 23.28.8.12-Supplying, installation, Testing andCommissioning of Panel light 2x2 ft., of following bodymaterial and construction as per IS : 10322 with driver as perthe requirement with Driver efficiency )85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KVwith Short and Open circuit protection,THD ( 10% , P.F.=0.95, IP20, CRI )80, UGR (Unified Glare Rating) ( 19,Flicker free, (flicker should be below 5 %), life time(LED,Driver and electrical circuitry), of minimum 50000Burning Hours with , 70% of initial Lumen maintained till lifeends ,CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (3,Maximum power consumption should not more than thespecified rating and Fixture shall be of relevant BIS standardand trade mark certificate (T.C.). Manufactures Word Mark/Name Engraved/ Embossing/Screen printing on housing.complete in all respect i/c connections with 1.5 sq mm FRLS,PVC insulated copper conductor single core cable andearthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy )135 lm/Watt output . LM79 and LM80Test report from NABL lab for all testing required for LEDfixtures as per BIS shall be submitted. Shape size and CCTshall be as approved by Engineer-in-Charge as perrequirement. (Thermal management: heat sink of aluminumhousing such that LED junction temperature shall not riseabove 90°C). 12. CRCA Sheet Body (Thickness >= 0.50 mm)45 wattHSR R Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysNov 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender