Tender For Supply Installation Testing and Commissioning of Fire Detection & Alarm System Of Remaining Ac Zone & Non Ac Zone And Fire Damper At Mch Building, Under Medical College; Kolkata.
Tender Value
18.50 Lakhs
Estimated cost
Bid Submission
03 Dec 2026
14 days left
EMD
37000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply Installation Testing and Commissioning of Fire Detection & Alarm System Of Remaining Ac Zone & Non Ac Zone And Fire Damper At Mch Building, Under Medical College; Kolkata.
BOQ
| Sl. No. | Item Description |
| 1 | (Part III)... Fire Detection Installation Work.Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. a)Two Loop Panel. (Approved Make : Honeywell-Esser/ Johnson Controls/ Siemens/BOSCH) |
| 2 | Supply, Installation, Testing & Commissioning of EN Standard, VDS approved Analog Addressable Intelligent multi sensor detector with decentralise intelligence, soft addressable Photo thermal type with inbuilt fault isolator as per NFPA style & wiring complete with base as required following VDS;EN54 (Approved Make : Honeywell-Esser/ Johnson Controls/ Siemens/BOSCH) |
| 3 | Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed temperature thermistor complete with inbuilt fault isolator as per NFPA style & wiring complete with base as required following VDS; EN54. (Approved Make : Honeywell-Esser/ Johnson Controls/ Siemens/BOSCH) |
| 4 | Supplying, installation, testing & commissioning ofaddressable manual call point within built fault isolators per NFPA style & wiring complete as required following VDS; EN54. (Approved Make : Honeywell-Esser/ Johnson Controls/ Siemens/BOSCH) |
| 5 | Supplying, installation, testing & commissioning ofaddressable horn cum strobe complete as required. (Approved Make : Honeywell-Esser/ Johnson Controls/ Siemens/BOSCH) |
| 6 | Supplying, installation, testing & commissioning ofaddressable fire control module within built fault isolators per NFPA style complete as required. (Approved Make : Honeywell-Esser/ Johnson Controls/ Siemens/BOSCH) |
| 7 | Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.(Approved Make : Honeywell-Esser/ Johnson Controls/ Siemens/BOSCH) |
| 8 | Supplying and fixing of following sizes of mediumclass PVC conduit along with accessories insurface/recess including cutting the wall and makinggood the same in case of recessed conduit asrequired. A) 20 mm (Make: Precisson/Polycab) |
| 9 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required. (Make: KEI/Gloster/Precisson/Polycab) |
| 10 | Through Checking of existing Fire Detection system installed at MCH building under MCHES-II/ PWD by deputing requisite technicians and engineers as per requirement & rectified the all fault. Software commissioning charge in case of any software issue / Device Removing from Detection line / Re-Commissioning after adding new devices. This is including all necessary tools, tackles, ladder etc. & issue of fit certificate. |
| 11 | S&F of MS box of suitable size of fire panel with locking arrangement with front acrylic door incl. necy. Painting and locking arrangement as per direction of EIC. |
| 12 | Supply, fixing, testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. ( MK: Airmaster/ Systemair/Premire/ Air Enerprise)a) Fire Damper |
| 13 | b) Actuator with controlling unit and detector |
| 14 | Dismantle the existing Fire detectors, MCP, Hooters, RI, Wrings & cables etc. without damage as per direction of EIC & submit the same in section office. Rewiring & re-fixing the same one (detectors, MCP, Hooters, RI , Wrings & cables etc ) in different location of MCH Building after completion of wiring as per direction of EIC & connect this system with the existing panel. This is including all necessary tools, tackles, ladder etc |
| 15 | One time rectification/cleaning contract of following types of Addressable type fire detection system(Make- siemens) as mentioned below. (Labour Cost). This is including all necessary tools, tackles, ladder etci) Multi Detector/Heat detector |
| 16 | ii) MCP |
| 17 | iii) Hooter |
| 18 | iv) Repeter Panel / main panel |
| 19 | v) Module |
| 20 | vi) RI |
| 21 | [ Rate should be quoted inclusive of all taxes, cess, duties. ] Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysDec 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender