Tender for Special Repair Of Firefighting System, Connected Allied Works At ‘B Area Of 2 Asd At Beas Under Ge Kapurthala
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Garrison Engineer Kapurthala Name of Work : Special repair of firefighting system, connected allied works at ‘B’ area of 2 ASD at Beas under GE Kapurthala Contract No : GE KPT- /2026-27 Bidder Name : SCHEDULE OF WORKS(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # S.No Description of work Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for taking out and laying CI/GI pipe complete all as specified and directed. |
| 3 | Returing, filling in, including spreading, leveling watering and well ramming inlayers not exceeding 25 cms thick each layer complete all as specified and directed. |
| 4 | Removal of surplus spoil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 5 | Taking down existing rusted CI/ GI pipe outer dia upto 80 mm bore line from trench/wall/floor/roof stacking it for re-use or issued to contrctroctor as credit. |
| 6 | - ditto - all as per item No 4 above here in before but pipe of outer dia 100mm bore complete all as specified and directed. |
| 7 | - ditto - all as per item No 4 above here in before but pipe of outer dia 150mm bore complete all as specified and directed. |
| 8 | - ditto - all as per item No 4 above here in before but pipe of outer dia 200mm bore complete all as specified and directed. |
| 9 | - ditto - all as per item No 4 above here in before but pipe of outer dia 250mm bore complete all as specified and directed. |
| 10 | Supply, laying, jointing and testing GI tubing 50mm bore Heavy Class grade in any length with all fitting laid in trench/wall/floor/roof and connecting up with water supply main complete all as specified and directed.Note:- Qooted rate deemed to be including all GI fittings and joint materials). |
| 11 | - ditto - all as per item No 9 above here in before but GI pipe of 65mm bore complete all as specified and directed. |
| 12 | - ditto - all as per item No 9 above here in before but GI pipe of 80mm bore complete all as specified and directed. |
| 13 | - ditto - all as per item No 9 above here in before but GI pipe of 100mm bore complete all as specified and directed. |
| 14 | Supply, laying, jointing and testing of MS ERW pipe (as per IS:1239 (Part-I) or IS 3589: 1981) of nominal dia 80 mm bore (thickness minimum 4.5 mm) including specials/fitting laid in trench/wall/floor/roof and connecting up with supply mains complete all as specified and directed. Note:- Qouted rate deemed to be including all MS fittings viz elbow/bend/sockets/couplings/gaskets/ring/flange/tee etc; including joint materials and complete pipe including fittings will be measured in running meter. |
| 15 | - ditto - all as per item No 13 above here in before but MS ERW pipe of nominal dia 100 mm bore complete all as specified and directed. |
| 16 | - ditto - all as per item No 13 above here in before but MS ERW pipe of nominal dia 150 mm bore complete all as specified and directed. |
| 17 | - ditto - all as per item No 13 above here in before but MS ERW pipe of nominal dia 200 mm bore complete all as specified and directed. |
| 18 | - ditto - all as per item No 13 above here in before but MS ERW pipe of nominal dia 250 mm bore complete all as specified and directed. |
| 19 | Supply, laying, jointing and testing new DI (K-7) pipe 80 mm bore centrifugally cast class K-7 confirming to IS : 8329 - 2000 spigot and socketed ends in any length laid in trenches complete all as specified and directed. Note:- Quoted rate deemed to be including DI fitting viz elbow/bend/sockets/couplings/gaskets/ring/flange/tee etc; and new run lead joint/ rubber Joint). |
| 20 | - ditto - all as per item No 18 above here in before but DI (K-7)100 mm bore |
| 21 | - ditto - all as per item No 18 above here in before but DI (K-7)150 mm bore |
| 22 | Supply and fixing in replacment cast iron sluice valve 80 mm bore with flanged ends, ISI mark with Gun metal/ steel spindle, CI gate with brass ring and iron wheel handle with jointing material such as nuts /bolts washers and rubber insertion sheet etc including taking out old U/S sluice valvecomplete all as specified and directed. |
| 23 | - ditto - all as per item No 21 here in before but 100 mm dia. |
| 24 | - ditto - all as per item No 21 above here in before but 150 mm bore complete all as specified and directed. |
| 25 | - ditto - all as per item No 21 above here in before but 200 mm bore complete all as specified and directed. |
| 26 | M&L for repair of valve pits of internal dimensions 90cm x 90 cm x 90 cm making good disturbed/dismantled brick work in cement mortar (1:4) plastering surfaces in cement mortar 1:6, 15mm thick and PCC coping in cement concrete 1:2:4 type B-1 and providing MS cover in replacement made out of MS sheet 3 mm thick duly welded to MS angle iron frame 35x35x5mm including frame work as per existing size with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.(a) M&L for brick work using sub class 'B' (old size bricks) in cement mortar 1:4 (b) M&L for rendering 15 mm thick in cement mortar 1:4 finishing even and fair (c) M&L for PCC 1:2:4 type B-0 (using cum 12.5 mm graded stone aggregate ) as in coping (d) M&L for any type of mild steel work such as frame sheet 3 mm thick including welding (e) M&L for painting two coats of synthetic enamel paint over a coat of red oxide primer to untreated steel surface & prep of surface. |
| 27 | S&F of yard hydrant post/ stand post 80 mm Dia GI/ MS both flanged type 1.5 m height including taking down unsv existing hydrant post and making the good distrubed plinth area. (Note : PCC for repair of plinth area of the hydrant post shall be measured and paid separtely under relevent item of Schedule) |
| 28 | S&F of fire hose cabinet box of 18 gauge MS Sheet 800mmx 600mmx 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS Sheet painted fire red out side and red/ brilliant white inside yard and fixing on the exisitng plinth by using welding/ fasteners complete including dismantling existing unsv/ rusted hose box all as specified and directed. |
| 29 | Supply installation testing and commissioning 100% synthetic flex canvas non percolating type confirming to IS 636 RRL hose (type A) ISI marked 63 mm dia x 15 m long with stainless steel male and female coupling (ISI marked) bound and riveted to hose pipes with copper rivets and copper wire as required . |
| 30 | Supply and fixing 63mm dia,15 mtr long rubberised fabric reinforced rubber lined hose including gun metal/steel male and female instantaneous coupling hose conforming to IS:636 type II and coupling conforming to IS 903-1975 complete all as specified. |
| 31 | S&F of male female coupling 63mm gun metal/ steel for fixing on fire hydrant including taking out unsv complete all as specified and as directed. |
| 32 | Taking out old defective underground cable from trenches/ floors/road/wall /pipe/ pole LT cable of any size/ description including Note:- Excavation and earth work will be measured separately under respective item. |
| 33 | Supply, Laying, jointing and testing XLPE PVC insulated & PVC sheathed LT cable, 1100 volts grade (heavy duty )with stranded aluminium conductor, cross sectional area 240 Sqmm 3.5 core fixed along the poles or passing through pipes or laid under floors or through walls complete all as specified.Note:- Earthwork, sand cushioning, brick protection and GI pipe to be measured and paid for separately under respective items. |
| 34 | M&L for sand cushioning with a layer of sand 8cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified. |
| 35 | M&L for old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed. |
| 36 | M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate for foundation of poles, stay, valve chambers/ hydrant post plinth etc. |
| 37 | M&L for PCC 1:3:6 type C1 using 20mm graded for padestal coping incl necessary formwork finished fair using extra cement. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysDec 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender