Tender For Srs/Replacement To Water Supply Distribution At Chitralekha Complex At Hq Sac(U) Under Ge (Af) Trivandrum
Tender Value
43.64 Lakhs
Estimated cost
Bid Submission
09 Dec 2026
19 days left
EMD
87300
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvananthapuram → Kerala
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Srs/Replacement To Water Supply Distribution At Chitralekha Complex At Hq Sac(U) Under Ge (Af) Trivandrum
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for laying UG cable/steel tubing etc and getting out in hard/dense soil complete all as specified and directed. |
| 2 | Returning, filling in, including spreading levelling, watering and well ramming in layers not exc 25 cm thick with soil complete all as specified and directed. |
| 3 | Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. |
| 4 | Taking up or down steel tubing and connections of size 40mm dia bore including cleaning for refixing or removal to store complete all as specified and directed.Note: Excavation and earth work shall be measured and paid separately |
| 5 | All as per item No. 4 here in above but of size 50mm dia bore |
| 6 | All as per item No. 4 here in above but of size 80mm dia bore |
| 7 | All as per item No. 4 here in above but of size 100mm dia bore |
| 8 | All as per item No. 4 here in above but of size 150mm dia bore |
| 9 | Supply and laying and testing of medium grade galvanised iron steel tubing of size 40mm dia bore, ISI marked, including GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tees, checknuts, caps, plugs etc complete laid in trenches/floors etc complete all as specified and directed. Make : Jindal/Tata/Prakash |
| 10 | All as per item No. 9 here in above but of size 50mm dia bore |
| 11 | All as per item No. 9 here in above but of size 80mm dia bore |
| 12 | All as per item No. 9 here in above but of size 100mm dia bore |
| 13 | All as per item No. 9 here in above but of size 150mm dia bore |
| 14 | Taking up or down CPVC pipe and connections of size 25mm dia bore complete all as specified and directed. |
| 15 | All as per item No. 14 here in above but of size 32mm dia bore |
| 16 | Supply and fix in replacement of 3-layer CPVC concealed pipes SDR 11 and Plain CPVC SDR 11 for hot and cold water supply including all CPVC plain and brass threaded polypropylene random fittings fixed of size 25 mm dia bore complete to walls,ceillings or in floors or in trenches complete all as specified and directed |
| 17 | All as per item No. 16 here in above but of size 32mm dia bore |
| 18 | Taking up or down UPVC pipe and connections of size 25mm dia bore including cleaning for refixing or removal to store complete all as specified and directed. Note :Excavation and earth work shall be measured and paid separately |
| 19 | All as per item No. 18 here in above but of size 32mm dia bore |
| 20 | All as per item No. 18 here in above but of size 50mm dia bore |
| 21 | Supply and fix in replacement of 3-layer UPVC(ASTM Sch-80) pipes of pressure rating 10 kgf/sqr cm having thermal stability including all UPVC plain and brass threaded polypropylene random fittings fixed for size 25mm dia bore complete to walls,ceillings or in floors complete all as specified and directed |
| 22 | All as per item No. 21 here in above but of size 32mm dia bore |
| 23 | All as per item No. 21 here in above but of size 50mm dia bore |
| 24 | S & F in replacement of Gun metal/Bronze globe or gate valve with iron wheel head, screwed both ends for iron pipe of size 25mm dia bore and conforming to IS 778 of 1984 complete all as specified and directed. Make : Leader/Kirloskar/Zoloto |
| 25 | All as per item No. 24 here in above but of size 32mm dia bore |
| 26 | All as per item No. 24 here in above but of size 40mm dia bore |
| 27 | All as per item No. 24 here in above but of size 50mm dia bore |
| 28 | S & F in replacement of CI sluice valves of size 80mm dia bore, flanged, heavy duty, class PN 1.6, as per IS-14856 including brass spindle, with hand wheel, nuts bolts and gaskets complete all as specified and directed. Make Leader/Kirloskar/ Bir |
| 29 | All as per item No. 28 here in above but of size 100mm dia bore |
| 30 | All as per item No. 28 here in above but of size 150mm dia bore |
| 31 | All as per item No. 28 here in above but of size 200mm dia bore |
| 32 | S & F in replacement of Non return (Reflux)(Dual plate check valve) Valve, cast iron, of size 80mm dia bore, flanged, with GM working parts as per IS - 5312, with nuts bolts and gaskets complete all as specified and directed. Make Leader/Kirloskar/Normax |
| 33 | All as per item No. 32 here in above but of size 100mm dia bore |
| 34 | S & F in replacement of gun metal non return valve of 50 mm dia bore, screwed complete all as specified and directed.Make:leader/ Kirloskar/ zoloto |
| 35 | S & F in replacement of CI foot valve Ball type flanged end of size 50mm dia bore, flanged/as per IS - 4038 with nuts, bolts and gaskets etc complete all as specified and directed. Make Normax,/Kirloskar/ Leader |
| 36 | All as per item No. 35 here in above but of size 80mm dia bore |
| 37 | All as per item No. 35 here in above but of size 100mm dia bore |
| 38 | All as per item No. 35 here in above but of size 150mm dia bore |
| 39 | Supply and fix in replacement of Pressure gauge 25 mm dia with ball valve of pressure 25 Kg/Sqcm complete all as specified and directed.(MAKE: H GURU,GLYCERINE FIELD,FIEG/ any command approved make) |
| 40 | S & F in repairs gun metal non return valve of 25 mm dia bore, screwed, ISI marked complete all as specified and directed. |
| 41 | S & F in repairs gun metal non return valve of 32 mm dia bore, screwed, ISI marked complete all as specified and directed. |
| 42 | M & L for plain cement concrete 1:3:6 type C1 using 20mm graded aggregate laid in foundations/ valve chamber filling, support of pipe laying and mass concrete etc complete all as specified and directed. |
| 43 | S&F in repairs UPVC flat submersible, water proof cable, 3 core 10 Sqmm copper conductor, multi stranded 1100V grade complete all as specified and directed.Make:Finolex/Plaza/ Polycap |
| 44 | All as per item No. 43 here in above but of size 16 sqmm |
| 45 | M&L for road cutting including excavation , returning filling in, spreading, levelling, well ramming in layers, hardcore with store aggregates received from dismantling the road for 100mm thick and finishing with PCC 1:2:4 with 20mm aggregate for 100mm thick and compacted complete all as directed and match to the existing finish at site complete all as specified and directed. |
| 46 | S & F in replacement of Air release Valve, cast iron, of size 100mm dia bore, flanged, with GM working parts as per IS - 5312, with nuts bolts and gaskets complete all as specified and directed. Make Leader/Kirloskar/Normax |
| 47 | M&L for Masonry valve chamber 1500 x 1200 x 900 mm including excavation and earth work in any type of soil and 100 mm thick PCC 1:4:8 type D2 foundation, brick work in CM (1:4), plastering internal, top and external surfaces (15cm below GL only) with 15 mm thick CM (1:4), PCC (1:3:6) type C1 coping, incl provn of 5 mm thick MS sheet with frame work of 40 x 40 x 6 mm angle iron complete with locking arrangement, painting steel and iron surface with two coat of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and directed. |
| 48 | M&L for iron removal plant of 50 cum/hr capacity by removing existing filter media completely and supply and lay the media as per manufacturer recommendation in layers vertically from bottom to top as recommendation by OEM and testing complete with back wash of iron removal plant Iron removal filter to function to the entire satisfaction of Engineer in Charge complete all as specified and directed. |
| 49 | M&L for activated carbon filtration plant of 50 cum/hr capacity by removing existing filter media completely and supply and lay the media as per manufacturer recommendation in layers vertically from bottom to top as recommendation by OEM and testing complete with back wash of carbon filtration plant to function to the entire satisfaction of Engineer in Charge complete all as specified and directed. |
| 50 | M&L for dual media filtration plant of 50 cum/hr capacity by removing existing filter media completely and supply and lay the media as per manufacturer recommendation in layers vertically from bottom to top as recommendation by OEM and testing complete with back wash of dual media filtration plant to function to the entire satisfaction of Engineer in Charge complete all as specified and directed. |
| 51 | Supply and fix in replacement of on load change over switch 4 pole 415 volt AC, 50/60 Hz, 250 A complete all as specified and directed.Make:LT or Havells/Schneider |
| 52 | M& L for taking our old valve pit covers and M& L for valve pit cover with MS sheet cover 5 mm thick surrounded by MS angle iron of size 40 x 40 x 6 mm framework embedded in PCC coping of 1:3:6 type C2, painted with two coats of synthetic enamel paint over one coat of red oxide primer on steel surface including earth work and excavation complete all as specified and directed. Note : PCC and angle iron will be measured and paid separately. |
| 53 | S & F in replacement of DOL starter suitable for induction motor of current rating 2 to 8 A, 3 Phase 415 Volts, 50 Hz AC complete all as specified and directed. Make: L&T/ siemens/Schneider |
| 54 | S & F in replacement of fully automatic Star Delta Starter suitable for induction motors of current rating 6 to 20 A, 3 Phase 415 Volts 50 Hz AC, with single phase protection complete all as specified and directed. |
| 55 | All as per item No.54 here in above but current rating 17 to 24 A complete all as specified and directed. Make Type of ML 1.5F of L&T or M Contactor or equivalent in/Seimens/Schneider. |
| 56 | All as per item No.54 here in above but current rating 26 to 40 A complete all as specified and directed. Make Type of ML 3F of L&T or M Contactor or equivalent in/Seimens/Schineder. |
| 57 | S & F in replacement of CI Butterfly valves of size 100mm dia bore, flanged, heavy duty, class PN 1.6, as per IS-14856 including brass spindle, with hand wheel, nuts bolts and gaskets complete all as specified and directed.Make Leader/Kirloskar/ Bir |
| 58 | Supply, Install, testing & commissioning in replacement of factory made indoor type IP 55 ,Heavy duty CRCA mild steel powder coated panel of thickness 2mm designed strictly in accordance with NFPA 20 in fire fighting pipelines consisting of Automatic Fire Fighting Pump Panel for monitoring pressure Jockey pump of capacity 40HP & Main pump of capacity 75HP consisting of following :-HQ Pump house complete all as specified and directed. |
| 59 | Item no: 58 ctd...(i) in coming On load change over switch four pole 400 Amp,50 KA - 01 Nos(ii) Auto starter for 75 HP ,Integrated with pressure switch of main water line - 01 Nos(iii) Auto starter for 40 HP ,Integrated with pressure switch of main water line - 01 Nos(iv) Digital multifunctional meter at incoming and outgoing(v) Incoming MCCB 400Amps,50KA,4 pole 415 Volts Microprocessor based release-1 No(vi) Outgoing MCCB 200Amps,36KA,4 pole 415 Volts Microprocessor based release-1 No(viii)Outgoing MCCB 125 Amps,25KA,4 pole 415 Volts Microprocessor based release-1 No(ix) Outgoing MCCB 160 Amps,36KA,4 pole 415 Volts Microprocessor based release-1 No (x)R,Y&B Phase indicator neon lamps for 3 Ph -01 Set(xi) Aluminium bus bar for 3 Ph & Neutral 400 Amp (25MMX9MM) 6-WAY for switch gear inter connection of sufficient length (xii) Digital Volt meter and ammeter of suitable rating in each incoming & out going feeders & including internal wirings (xiii)Space for fixing of Auto starter of 10HP connection for outgoing feederNote:1- The design of the panel dependent on as site requirement 2- Cost for foundation as per manufacturers dimensions is included in rate quoted / item rate includes civil works, all materials, labor, equipment, testing, and commissioning. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysDec 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender