Tender For Work Of Renovation Of The Existing Lt Lines Covering 41 Nos. Of Distribution Transformer Centres At V.P. Kirlapal Dabal Under The Tribal Sub-Plan In Sanvordem Constituency, Under The Jurisdiction Of Electrical Sub Div-Iv, Division Vii, Cur
Tender Overview
Project Description
Tender for Work Of Renovation Of The Existing Lt Lines Covering 41 Nos. Of Distribution Transformer Centres At V.P. Kirlapal Dabal Under The Tribal Sub-Plan In Sanvordem Constituency, Under The Jurisdiction Of Electrical Sub Div-Iv, Division Vii, Curchorem
BOQ
| Sl. No. | Item Description |
| 1 | Supply |
| 2 | Supply of RCC pole 9mtrs long R.C.C. Pole as per drawing approved by CEE and conforming to IS standards as amended upto date. |
| 3 | Supply of RCC pole 7.5mtrs long R.C.C. Pole as per drawing approved by CEE and conforming to IS standards as amended upto date. |
| 4 | Providing of Cement concrete in the ratio 1:2:4(1 cement: 2 Sand, 4 graded granite/basaltic, aggregate 20mm nominal size) including cost of centering, shuttering & muffing 0.4mts above the ground & properly curved |
| 5 | Supply of Cross Arm Channel 4Pin .The cross arms shall be made of M.S. channel of ISMC-75 vide table 2 of IS: 8081 1964 . The cross arms shall be without any joints. The cross arms shall be hot dipped galvanized generally conforming to IS - 2633/72. The length of the 4pin cross arm shall be 1110mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm for clamping arrangement to the pole. The length of the 4pin side cross arm shall be 1410mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm 40 mm from the left edge of the X-arm for clamping arrangement to the pole & two holes of size 17mm dia at 355mm & 660mm from the slotted hole for arrangement to fix angle support. The angle support shall be of ISA 50x50x6mm G.I. with 17 mm dia holes at the two ends. The other end of the angle shall be clamps utilizing suitable G. I. stay clamps of length 312mm end to end [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas] |
| 6 | Supply of Cross Arm Channel 2Pin .The cross arms shall be made of M.S. channel of ISMC-75 vide table 2 of IS: 8081 1964 . The cross arms shall be without any joints. The cross arms shall be hot dipped galvanized generally conforming to IS - 2633/72. The length of the 4pin cross arm shall be 1110mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm for clamping arrangement to the pole. The length of the 4pin side cross arm shall be 1410mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm 40 mm from the left edge of the X-arm for clamping arrangement to the pole & two holes of size 17mm dia at 355mm & 660mm from the slotted hole for arrangement to fix angle support. The angle support shall be of ISA 50x50x6mm G.I. with 17 mm dia holes at the two ends. The other end of the angle shall be clamps utilizing suitable G. I. stay clamps of length 312mm end to end [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas] |
| 7 | Supply of HDGI 11KV V-Shape X arm [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas] |
| 8 | Supply of Cut point Channel 1.3 mtr long [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas] |
| 9 | Supply of HDGI Top fitting for 11KV [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas] |
| 10 | Supply of HDGI Top fitting cross arm ISMC channel,75x40mm,0.7mts long [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas] |
| 11 | Supply of 11KV guard cross arm, ISMC channel 75 x 40mm, 1.5mtr long [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas] |
| 12 | Supply of GI Xarm clamp LA for 9.0mts pole shall be hot dipped galvanized generally conforming to IS - 2633/72 [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas] |
| 13 | Supply of GI Xarm clamp SA for 9.0mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73 [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas] |
| 14 | Supply of GI stay clamp SA for 9.0mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73 [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas] |
| 15 | Supply of GI Xarm clamp LA for 7.5mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/74 [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas] |
| 16 | Supply of GI Xarm clamp SA for 7.5mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/75 [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas] |
| 17 | Supply of 11kv Pin insulators with GI pins |
| 18 | Supply of 11kv Disc insulators with metal parts 45KN |
| 19 | Supply of LT pin insulator with GI pin |
| 20 | Supply of Insulator -(LT) Shackle .L.T. brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN. Insulators shall have marking and packing as prescribed in IS |
| 21 | Supply of ACSR 'WEASEL' of size ( 6/1/2.59mm) for earthing and jumpering .Packing and marking of drum will be as per IS:Conductor length shall be 1500 mtr. with tolerance of +/- 5% |
| 22 | Supply of conductor-AA ANT, 2. 7/3.10 mm . |
| 23 | Supply of conductor -AA GNAT,1. 7/2.21 mm, |
| 24 | Supply of Anticlimbing device(barbed wire).Hot dip galvanized steel barbed wire type 4 conforming to IS:278/1962 as amended upto date and galvanization conforming to IS:4826/1979as amended upto date |
| 25 | Supply of 11KV Enamelled danger board of size 250mm x 200mm. |
| 26 | Supply of Earthing complete with 2.5mts long, 40mm GI earthing pipe, class B, 20kgs each of salt and charcoal, excvation, re-filling etc chamber with brick masonary..Earthing pipe made of Hot Dip galvanized steel tube of heavy class, 40mm nominal bore conforming to IS 1239 Part 1 1990 as amended upto date and Hot Dip zinc coating shall conform to IS 4736-1968 as amended upto date |
| 27 | Supply of Stay set complete for 9.0 mts RCC Pole.HDGI Stay Sets Complete Comprising of stay rod with plate, HDGI stay wire of size 7/10swg, Break insulator of 15KV/8KV,HDGI turn buckle with eye bolt, suitable HDGI stay clamps, HDGI nut bolts, . The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof and also as per the specifications enclosed. |
| 28 | Supply of Stay set complete for 7.5 mts RCC Pole.HDGI Stay Sets Complete Comprising of stay rod with plate, HDGI stay wire of size 7/10swg, Break insulator of 15KV/8KV,HDGI turn buckle with eye bolt, suitable HDGI stay clamps, HDGI nut bolts, . The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof and also as per the specifications enclosed. |
| 29 | Supply of HDGI D.P Structure Materials. All the materials shall be hot dipped galvanized [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas] |
| 30 | Supply of 11 KV GOAB switch with 200 A.12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part1 to V as amended upto date and detailed specifications enclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy |
| 31 | Supply of 11 KV HG fuse,200A, Horn gap type fuseI.TECHNICAL PARTICULARS:1. Highest System voltage : 12 KV (R.M.S)2. Impulse voltage withstand voltage : 75 KV (Peak)3. One minute power frequency withstand voltage : 35 KV (R.M.S.)4. Continuous current rating of the unit : 200 Amps |
| 32 | Supply of 9 KV, 5A Lightning Arrestor, pole mounted.9 KV, 5 KA nominal discharge current Metal Oxide gapless distribution class lightning arrestor conforming to IEC-60099-4 and IS 3070 Part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arrangements and connector suitable to connect ACSR conductor upto overall diameter 12.30 mm.The marking of the Lightning Arrestors shall be as per IS |
| 33 | Supply of MS Distribution box complete.M. S. distribution box MCCB of 400Amps capacity Kit Kat Porcelain fuse carrier and base with extended terminals. |
| 34 | Supply of Distribution Transformer metering unit |
| 35 | Supply of HDGI nuts & bolts.G.I. Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part 1 to 3 1992 as amended upto date.The bolts and nuts shall be hot dip galvanized as per IS: 2629-1985 as amended upto date |
| 36 | Supply of XLPE armoured cable 3 & 1/2 core 240 sq.mm.The armoured cable shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder |
| 37 | Supply of XLPE armoured cable 3 & 1/2core 120 sq.mm.The armoured cableshall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder |
| 38 | Supply of XLPE armoured cable 3 & 1/2 core 95 sq.mm(For Neutral).The armoured cable shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder |
| 39 | Supply of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes: 1)240Sq.mm |
| 40 | Supply of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes:1. 120 Sq.mm |
| 41 | Supply of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes:1. 95Sq.mm. |
| 42 | Supply of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes:1. 70Sq.mm. |
| 43 | Supply of FRP Fencing complete with Gate around every distribution sub-station containing , one distribution transformer and one LV switchboard including danger plate (Size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6 |
| 44 | Cost of Erection/ dismantling of old network |
| 45 | Erection of 9 mts. long RCC poles .The poles should be as per drawing approved by CEE and conforming to IS standards as amended upto date. The Component used for pole shall conform to following IS amended upto date. |
| 46 | Erection of 7.5mts. long RCC poles .The poles should be as per drawing approved by CEE and conforming to IS standards as amended upto date. The Component used for pole shall conform to following IS amended upto date |
| 47 | Fixing of Cross Arm Channel 4Pin .The cross arms shall be made of M.S. channel of ISMC-75 vide table 2 of IS: 8081 1964 . The cross arms shall be without any joints. The cross arms shall be hot dipped galvanized generally conforming to IS - 2633/72. The length of the 4pin cross arm shall be 1110mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm for clamping arrangement to the pole. The length of the 4pin side cross arm shall be 1410mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm 40 mm from the left edge of the X-arm for clamping arrangement to the pole & two holes of size 17mm dia at 355mm & 660mm from the slotted hole for arrangement to fix angle support. The angle support shall be of ISA 50x50x6mm G.I. with 17 mm dia holes at the two ends. The other end of the angle shall be clamps utilizing suitable G. I. stay clamps of length 312mm end to end |
| 48 | Fixing of Cross Arm Channel 2Pin .The cross arms shall be made of M.S. channel of ISMC-75 vide table 2 of IS: 8081 1964 . The cross arms shall be without any joints. The cross arms shall be hot dipped galvanized generally conforming to IS - 2633/72. The length of the 4pin cross arm shall be 1110mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm for clamping arrangement to the pole. The length of the 4pin side cross arm shall be 1410mm with 4 holes of 22 dia each on each flange section. In addition 2 holes of size 18mm x 40mm slotted holes shall be provided on the cross arm 40 mm from the left edge of the X-arm for clamping arrangement to the pole & two holes of size 17mm dia at 355mm & 660mm from the slotted hole for arrangement to fix angle support. The angle support shall be of ISA 50x50x6mm G.I. with 17 mm dia holes at the two ends. The other end of the angle shall be clamps utilizing suitable G. I. stay clamps of length 312mm end to end |
| 49 | Fixing of HDGI 11KV V-Shape X arm |
| 50 | Fixing of Cut point Channel 1.3 mtr long |
| 51 | Fixing of HDGI Top fitting for 11KV |
| 52 | Fixing of HDGI Top fitting cross arm ISMC channel,75x40mm,0.7mts long |
| 53 | Fixing of 11KV guard cross arm, ISMC channel 75 x 40mm, 1.5mtr long |
| 54 | Fixing of GI Xarm clamp LA for 9.0mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/72 |
| 55 | Fixing of GI Xarm clamp SA for 9.0mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73 |
| 56 | Fixing of GI stay clamp SA for 9.0mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/73 |
| 57 | Fixing of GI Xarm clamp LA for 7.5mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/74 |
| 58 | Fixing of GI Xarm clamp SA for 7.5mts pole.shall be hot dipped galvanized generally conforming to IS - 2633/75 |
| 59 | Fixing of 11kv Pin insulators with GI pins |
| 60 | Fixing of 11kv Disc insulators with metal parts 45KN |
| 61 | Erection of LT pin insulator with GI pin |
| 62 | Fixing of Insulator -(LT) Shackle .L.T. brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN. Insulators shall have marking and packing as prescribed in IS |
| 63 | Stringing of ACSR 'WEASEL' of size ( 6/1/2.59mm) for earthing and jumpering .Packing and marking of drum will be as per IS:Conductor length shall be 1500 mtr. with tolerance of +/- 5% |
| 64 | Stringing of conductor-AA ANT, 2. 7/3.10 mm . |
| 65 | Stringing of conductor -AA GNAT,1. 7/2.21 mm, |
| 66 | Fixing of Anticlimbing device(barbed wire).Hot dip galvanized steel barbed wire type 4 conforming to IS:278/1962 as amended upto date and galvanization conforming to IS:4826/1979as amended upto date |
| 67 | Fixing of Enamelled danger board of size 250mm x 200mm |
| 68 | Erection of Earthing complete with 2.5mts long, 40mm GI earthing pipe, class B, 20kgs each of salt and charcoal, excvation, re-filling etc Chamber with brick masonary. Earthing pipe made of Hot Dip galvanized steel tube of heavy class, 40mm nominal bore conforming to IS 1239 Part 1 1990 as amended upto date and Hot Dip zinc coating shall conform to IS 4736-1968 as amended upto date |
| 69 | Erection of Stay set complete for 9.0 mts RCC Pole.HDGI Stay Sets Complete Comprising of stay rod with plate, HDGI stay wire of size 7/10swg, Break insulator of 15KV/8KV,HDGI turn buckle with eye bolt, suitable HDGI stay clamps, HDGI nut bolts, conforming to drawings approved. The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof and also as per the specifications enclosed. |
| 70 | Erection of Stay set complete for 7.5 mts RCC Pole.HDGI Stay Sets Complete Comprising of stay rod with plate, HDGI stay wire of size 7/10swg, Break insulator of 15KV/8KV,HDGI turn buckle with eye bolt, suitable HDGI stay clamps, HDGI nut bolts, conforming to drawings approved. The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof and also as per the specifications enclosed. |
| 71 | Fixing of HDGI D.P Structure Materials. |
| 72 | Erection of 11 KV GOAB switch with 200 A.12 KV rated voltage GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming to IS: 9921-Part1 to V as amended upto date and detailed specifications enclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufactures of the insulators and have minimum 320mm creepage distance and AB switches contacts shall be of copper/copper alloy |
| 73 | Fixing of 11 KV HG fuse,200A, Horn gap type fuseI.TECHNICAL PARTICULARS:1. Highest System voltage : 12 KV (R.M.S)2. Impulse voltage withstand voltage : 75 KV (Peak)3. One minute power frequency withstand voltage : 35 KV (R.M.S.)4. Continuous current rating of the unit : 200 Amps |
| 74 | Erection of 9 KV, 5A Lightning Arrestor, pole mounted.9 KV, 5 KA nominal discharge current Metal Oxide gapless distribution class lightning arrestor conforming to IEC-60099-4 and IS 3070 Part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arrangements and connector suitable to connect ACSR conductor upto overall diameter 12.30 mm.The marking of the Lightning Arrestors shall be as per IS |
| 75 | Erection of MS Distribution box complete.M. S. distribution box MCCB of 400 Amps capacity Kit Kat Porcelain fuse carrier and base with extended terminals. |
| 76 | Removing & re-erection of 200KVA Distribution Transformer |
| 77 | Removing & re-erection of 100KVA Distribution Transformer |
| 78 | Erection of Distribution Transformer Metering Unit. |
| 79 | Providing of HDGI nuts & bolts.G.I. Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part 1 to 3 1992 as amended upto date.The bolts and nuts shall be hot dip galvanized as per IS: 2629-1985 as amended upto date |
| 80 | Erection of XLPE armoured cable 3 & 1/2 core 240 sq.mm.The armoured cable shall suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder |
| 81 | Erection of XLPE armoured cable 3 & 1/2 core 120 sq.mm.The armoured cable shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder |
| 82 | Erection of XLPE armoured cable 3 & 1/2core 95 sq.mm(for Neutral).The armoured cable shall be suitably terminated at both the ends with appropriate sizes of Aluminum lugs duly crimped using a crimping tool. Appropriate sizes of G.I / Brass nut / bolts / washers shall be used for firmly connecting the same to the MCCB’s/Transformer L.T. Bushings/Outgoing LT feeder |
| 83 | Providing of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes: 1)240Sq.mm |
| 84 | Providing of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes:1. 120 Sq.mm. |
| 85 | Providing of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes:1. 95Sq.mm. |
| 86 | Providing of Aluminum crimping lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade 1E of IS 5082-1969 suitable for aluminium cables of following sizes:1. 70Sq.mm. |
| 87 | Erection of FRP Fencing complete with Gate around every distribution sub-station containing RMU, one distribution transformer and one LV switchboard including danger plate (Size 4Mx3Mx2M) with Concreting for FRP Fencing supports with plinth (0.3x0.3x0.5) Cu.m. x 12 nos. Each ratio 1:3:6 |
| 88 | Removing of Rail poles 90 lb/yd 11 mtr long |
| 89 | Removing of RCC poles 9 mtr long |
| 90 | Removing of RCC poles 7.5 mtr long |
| 91 | Removing of 4 pin cross arm |
| 92 | Removing of 2 pin cross arm |
| 93 | Removing of HDGI 11KV V shape X-arm |
| 94 | Removing of cut point channel 1.3 mtr long |
| 95 | Removing of HDGI Top Fitting for 11KV. |
| 96 | Removing of HDGI Top Fitting cross arm ISMC Channel, 75x40mm,0.7mtrs long |
| 97 | Removing of Shackle insulator with metal parts |
| 98 | Removing of Pin insulator with GI Pin |
| 99 | Removing & restringing of ACSR of weasel conductor |
| 100 | Removing AA ANT conductor |
| 101 | Removing AA GNAT conductor |
| 102 | Removing of old Rail pole DP structure materials |
| 103 | Removing of 11 KV GOAB switch 200A |
| 104 | Removing 11 KV HG fuse set 200A |
| 105 | Removing of 11kv Disc insulators with metal parts 45KN |
| 106 | Removing of MS Distribution Box |
| 107 | Removing of lightning arrestor |
| 108 | Removing XLPE armoured cable 3 1/2 core 240sq.mm. |
| 109 | Removing XLPE armoured cable 3 1/2 core 120sq.mm. |
| 110 | Removing XLPE armoured cable 31/2 core 95sq.mm. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender