Tender For Renovation Of Old Tai Building At Tnsamb Head Quarters, Chennai
Tender Value
1.47 Crore
Estimated cost
Bid Submission
26 Nov 2026
5 days left
EMD
1.80 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Renovation Of Old Tai Building At Tnsamb Head Quarters, Chennai
BOQ
| Sl. No. | Item Description |
| 1 | Earth work excavation for foundation by Mechanical means for Isolated & Combined Footing etc in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers.- Upto 2.40m Footing Depth. Data worked out for 48 m3 per day/8 hrs. |
| 2 | Earth work excavation for foundation by manual means for Isolated, Combined and Other type foundations in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers. |
| 3 | Supplying and filling in foundation, basement, etc with filling Crushed Stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 4 | Supply and filling in foundation and basement with Gravel in layers of not more than 15cm.thick well rammed watered and compacted with surface vibrator, watered and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 5 | Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers - Mixing by mechanical means |
| 6 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner, vertical stiffener, side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). |
| 7 | Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 8 | Foundation and Basement |
| 9 | For Ground floor |
| 10 | For First floor |
| 11 | Second floor |
| 12 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) |
| 13 | For 1 Qtl - upto plinth/Basement level: |
| 14 | Add additional labour for works above plinth/Basement level in every upper floor over the preceding floor or Below Ground level of every 3.50m depth. |
| 15 | Brick work in following Cement Mortar 1:5 using best quality Fly ash Brick of size 230x110x70mm with class designation of 10 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge. |
| 16 | For foundation & basement |
| 17 | In Ground floor |
| 18 | For First Floor |
| 19 | Second Floor |
| 20 | Damp proof course as per IS 3067:1988 with Cement Mortar 1:4 (One Cement and Four crushed stone sand) 12mm thick mixed with best approved quality Integral liquid water proofing compound conforming to Indian Standard specification as specified by the de- partmental officers at 2% by weight of cement used, finishing and curing etc. complete complying with standard specification - Manual Mixing |
| 21 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 22 | Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used, hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers. |
| 23 | Painting two coats of newly plastered wall surface with ready mixed plastic Interior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed by the departmental officers. |
| 24 | Painting two coats of newly plastered wall surface with ready mixed plastic Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed by the departmental officers. |
| 25 | Finishing the top of roof with one course of machine pressed tiles of following size of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers. |
| 26 | Paving the floor with best quality vitrified Tiles of following size and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 27 | Dadooing walls with following best approved quality, white / colour glazed tiles conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 28 | Flooring with ceramic tiles of following size and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 29 | Supplying and fixing Teak wood scantlings for door and windows and any other joinery works using teak wood scantlings below 4m in lengh and complete it in all floors including labour charges for the manufacture of frames as per standard specification. |
| 30 | Supplying, fabricating and fixing in position of steel frame without bottom frame, of size 100X60mm rectangular section with necessary rebate 30mmX15mm, to host the shutter,using 1.25mm thick (18 guage) CRCA cold rolled frame steel plate confirming to ISI specified ensured of right butt joint riveted hold assembly with nylon insert,not be welded with special purpose hard ware.Proclaimed including phopating as per ISI with rust preventive primer ready to assemble condition for easy installation at site including dismantling,making necessary chipping and holes in RCC columns, walls with power drills to the extent required ,including providing concrete 1:2:4 inside the box curing etc... complete complying with standard specification and as directed by the departmental officers. |
| 31 | Supplying and fixing solid core flush shutter of following type with thickness with necessary T.W. internal lipping alround conforming to IS 2202-1(1999) including cost of wind appliances and furniture fittings such as 3 Nos of SS 304 Grade Parliament Hinges of Size (125mm x 150mm) , 2 Nos 300x12mm aluminium tower bolt 1 No. 200x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 2 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete complying with standard specification and as directed by the departmental officers - |
| 32 | UPVC Window Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work |
| 33 | UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all-round the frames. The ventilator should be got approved from the Executive Engineer before use on work |
| 34 | Providing and fixing of Aluminium Composite Panel (ACP) 4 sided having 50 x 25 x 1.50mm frame work vertical and horizontals out of specially designed extruded sections withstand wind pressure of 180 Kg/sq.m and fabricated fixed at all level elevation and heights. The extruded section cutting and fixing required space extruded section shall be of 6063 and alloy of BSH 9 confirming T is – 63400 rate shall included to fix the main frame with necessary clamps, fasteners, bolt nuts etc. The main frame of extruded section shall be of 22843 & 22739 (H9) grade conforming to BS 4174 (or) IS 8147. Rate shall included 4mm thick ACP sheet (0.25 + 3.5 + 0.25) fixing with spacer tape and the ACP sheet bounded with special type structural sealant of dow corning 789 or equivalent in dust free conditions the gaps between ACP sheet to be filed with whether sealant and backer rod or 12mm foam sheet to ensure water and air tightness in all complete complying with standard specification as directed by the departmental officer |
| 35 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels… |
| 36 | Designing the Semi Unitised Structural Glazing System with open groove joint as per design intent, preparation of shop drawings for approval, supply, fabricate, erect as per approved shop drawings at all floor levels and all floor heights including conducting field test as per the test criteria set out in the particular specification... |
| 37 | Providing, assembling and Supplying of Double Glazed Performance glass, heat Strengthened clear Glass (IGUs) of size and shape as required and specified of approved, comprising of an outer heat strengthened clear glass of following thick of approved colour and shade with reflective soft coating on surface #2 and an inner heat strengthened clear glass of following thick , spacer tube 12mm wide , dessicants, including primary seal and secondary seal ( structural silicon sealant ) etc. all complete for the required performance, as directed by the engineer -in - charge. The heat strengthened clear glass having properties as visible Light transmittance (VLT) of 25 to 35 %, Solar heat gain coefficient less than or equal to 0.27 and U value of 3.0 to 3.3 W/m2 or lower degree K etc. The IGUs shall be assembled in the factory/ workshop of the glass processor. For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm |
| 38 | Providing, assembling and supplying of laminated glass panels for SKYLIGHT using heat Strengthened clear Glass and toughened glass sandwiched using 1.52PVB layer. The Glass of approved colour, size and shade all complete for the required performance, as directed by the Engineer in Charge. (6mm clear glass + 1.52mm PVB + 6mm performance glass) |
| 39 | Supplying fixing and errecting of steel roof trusses and roof truss purlins fixing for G.I. sheet roofing using MS. L. angle of size 50x50x6 mm raffter, Tie angles and MS angle of size 50x50x6mm for sturts and MS plat of size 12 mm thick for fixing G.I. sheet. The purlins using MS L. angle of size 50x50x6 mm shall be properly anchored to the supporting super structure and fixed in concrete at wall and spacing of purlins are to be arranged to use the standard size or sheet and spacing should not execeed 1680 mm and free over hang at eves should not be more than 400 mm, the cleats shall be wellded to the trusses firmly and fixed on the down stream side of purlins. The ridge purlins fixed at 77 to 115 mm away the apex of the roof. The trusses shall have welded joints only at all guessets plate junctions except gussets at bottom chords to have bolts and nuts to permit transportation of trusses as directed. The foundation anchor bolts of trusses will be fixed in concrete at wall in bed blocks and well cured, labour for erection of trusses of approved quality transportation, priming coat for all members, cutting, bending, and welding etc., The trusses should be connected at bottom 1 / 3 part by steel tie angles and with top and bottom wind bracings as per design given. The chord of the trusses of bottom channel should suitablely cambered. The truss and purlins should be given priming coat of Rex Oxide primer of approved quality including labour for erection, transportation, wellding etc., complete complying with standard specification. |
| 40 | Corrugated Metal Sheets waterproofing cum Heat reflective coating - Providing and applying heat reflective environmental friendly, 100% Pure Acrylic elastomeric waterproof coating on metal sheets. Replace roof fasteners, as required and needed. Sealing up of all lapping joints, gaps, flashing and capping with 2 component PMMA base waterproof Coating @3kg/ m2 including metal primer @.1L/m2 and fleece at a 150mm wide strip. Preparing the surface by cleaning with a brush and removing the rust using a chloride free chemical. Apply one coat of anti-corrosive primer at 0.15L/m² for GI/ Metal surfaces and apply one coat of solvent-free, medium-viscous, epoxy primer at 0.15L/ m² for powder- coated surfaces. Apply 2 coats of 100% Pure Acrylic waterproofing coating @ 0.8L/m2 having Elongation 190% as per ASTM D 412, tensile strength 1.5 N/mm2, SRI Index 108 as per ASTM E 1980-01. The finished cost to include surface preparation completely as per specification |
| 41 | waterproofing with TPO membrane - Providing and laying 1.5 mm thick TPO Membrane over old terrace having week surface/Lime mortar. The membrane is manufactured using hot-melt extrusion process for complete scrim encapsulation. It is reinforced with a strong, polyester reinforced fabric center (scrim) and a tough thermoplastic polyolefin compounded top ply and the bottom. It should have UV resistant top white colour which has a very high resistance to weather agents and UV rays. TPO membrane shall be plasticizer, chlorine & pthalate free, and should exceed/meet specifications of ASTM D6878. Membrane should be mechanically fixed to the substrate by independent plates and fasteners. TPO Roof Membrane should be lapped and seamed using hot air heat welding equipment after mechanically fastening the overlaps. Membrane should have following minimum properties, Breaking Strength min. 220lbf (976N) as per ASTM D751, Elongation break of reinforcement > 15 % as per ASTM D751, and Tear Strength 55lbf (245N) as per ASTM D751. The finished cost including surface preparation, application of TPO membrane over the 200GSM Geo- textile and termination of TPO membrane using 2mm thick aluminium strip sealing with PU sealant at the top of strip completely as per specification. |
| 42 | Treating Active leakage from Concrete walls Providing and grouting with single component Polyurethane Foam injection grout at dripping leakage locations, grout mixed at ratio of 10:1 (10 parts of Resin: 1 part accelerator) at the rate of 0.40kg/nozzle which will foam after reaction with water/ moisture, cream time <20 seconds, rise time <30 seconds, foam expansion more than 30 times. It has a mixed viscosity of <350 cP as per ASTM D 2196. Allow the PU foam grout to cure for 5 -10 mins. Providing and grouting with two component Polyurethane based resin injection grout mixed at ratio of 2:1 (2 parts of Base: 1 part Hardener) which will injected through same nozzle at the rate of 0.30kg/nozzel which gives Adhesion strength >2.5 MPa, Adhesion in wet concrete >1.5MPa, Elongation >80%. It has a mixed viscosity of <350 cP as per ASTM D 2196. The finished cost to include surface preparation, fixing of non-return valve injection packers at dripping leakage locations and damp patch locations, seal the nozzles with polyester resin anchor grout Instant leak plug 0.2kg/nozzle. All the application procedure shall be as per the direction of the Engineer In charge. |
| 43 | Structural Strengthening with Epoxy Injection Grout - Providing and grouting with two component low viscous Moisture Insensitive Epoxy Injection Grout to strengthen the structure at concrete cracks. The material having mixing ratio - (Base: Hardener) - 100:60 (by weight) at the rate of 0.50kg/nozzle, which gives compressive strength of 70N/mm2 in 7days as per BS6319:part 2, Flexural strength of 30N/mm2 in 7days as per BS6319:part 3, Tensile strength of 15N/mm2 in 7days as per BS6319:part 7, epoxy resin-based injection grout meets the requirement of BS 6319 & ASTM C 881. The finished cost to include surface preparation, fixing of non-return valve injection packers at concrete cracks, seal the nozzles with polyester resin anchor grout Instant leak plug 0.2kg/nozzle. All the application procedure shall be as per the direction of the Engineer In charge. |
| 44 | Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 45 | Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of \\"U\\" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification and as directed by the departmental officers. |
| 46 | Wiringwith2x1.5sq.mm. PVC insulated single core unsheathed FRLS copper conductor cable of 1100Vgrade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A FT switch with painting of Suitable colour with continuous earth wire connection of 1.5sq.mm copper wire for open PVC light point /fan point (for electronic regulator) |
| 47 | Wiring with 2x1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet cover for 5A3 pin non interlocking wall socket with 5Aflush type switch with cotinuous earth wire connection of1.5sq.mm copper wire and making good of the concealed portion with suitable colour for concealed PVC plug point |
| 48 | Wiring with 2 x 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet for 15A 3 pin non inter locking wall socket with 15A flush type switch with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed portion with suitable colour for concealed power plug point |
| 49 | Supply and run of 2 of 6 sq.mm.PVC insulated Sc unsheathed FRLS copper conductor of 1100V grade insuitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 6sq.mm copper wire with painting of suitable colour |
| 50 | Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting |
| 51 | Supply and fixing of single box type 4'36 W fluorescent fitting complete with electronic ballast with TW round block son wall or ceiling with flu tube with PVC unsheathed FRLS Copper leads from terminals to the fitting. |
| 52 | Supply and fixing of 300mm (12\\") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall |
| 53 | Supply and fixing of 1200mm (48\\") AC ceiling fan complete with stepped electronic 300W regulator with 300mm down rod on the existing clamp |
| 54 | Supply and fixing of fancy glass shade and 15 W LED Bulb etc., complete complying with standard specification and as directed by the departmental officer |
| 55 | Manufacturing, supplying, assembling, and placing in position modular office workstation tables of finished size 1500mm (Length)} x 600 mm (Width) x 900 mm (Total Height) with an integrated under-desk 3-drawer pedestal unit of finished size 400mm (W) x 500mm (D) x 700 mm (H). The main table top, side gable leg support panel, modesty panel (400 m depth), and outer pedestal carcass/drawer fronts shall be fabricated using 19 mm thick Boiling Water Proof (BWP) grade plywood conforming to IS 303 / IS 710 . All exposed outer surfaces shall be factory-pressed with 1.0 mm thick high-pressure decorative laminate conforming to IS 2046 of approved colour and texture, and unexposed/inner surfaces with 0.8 mm balancing laminate using phenol formaldehyde synthetic resin adhesive. All exposed plywood edges shall be neatly lipped with machine-pressed 2 mm thick matching PVC edge banding tape using hot-melt adhesive under high temperature and pressure. The internal 3-drawer boxes (sides, front inner, rear, and base bottom) shall be fabricated using 12 mm commercial grade plywood, mounted on heavy-duty 450 mm full-extension telescopic ball-bearing slides (minimum load capacity 35 kg). The pedestal shall be fitted with 1 No. multipurpose/central cylinder lock with master key arrangement and 3 Nos. 200 mm 'D' type stainless steel grade 304 handles. The entire table shall be supported on heavy-duty M8 nylon levelling buffer studs for floor alignment and provided with 1 No. 65 mm circular wire manager/cable grommet on the table top. Scope of supply includes providing 1 No. ergonomic mid-back revolving chair conforming to IS 3478 / BIFMA standards featuring breathable nylon mesh back, high-density PU moulded seat cushion, pneumatic Class 4 gas lift for height adjustment, 360° swivel with tilt lock mechanism, and nylon 5-star base with twin-wheel castors. Complete in all respects including materials, fabrication, transit packing, conveyance, loading, unloading, handling, site assembly, and cleaning as per standard specifications and as directed by the Engineer-in-Charge Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysNov 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender