Tender For Maintenance Of Lt Panel,Cables,Solar Lights And Connected Items Under Ge (North) Akhnoor
Tender Value
30 Lakhs
Estimated cost
Bid Submission
09 Dec 2026
18 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Maintenance Of Lt Panel,Cables,Solar Lights And Connected Items Under Ge (North) Akhnoor
BOQ
| Sl. No. | Item Description |
| 1 | Supply, and fixing feeder pillar box in replacement x of size 500x 450x500 mm made out of MS sheet of 2.0mm thick bent to shape & size factory made with welding, bending works suitable for and including 200 Amps rated aluminium bus bars ( length of bus bar not less than 40 cm) 4no's ,making holes of any size and mounted on porcelain/epoxy based post insulators of appropriate size with suitable size of nuts, bolts and washers complete with mounting leg of size 40x40x5 mm and length of angle iron not less than 1 mtr, 0.5 mtr to be embeded in PCC below G.L and 0.5 mtr above ground including painting of complete structure with two coats of super enamelled synthetic paint over a coat of red oxide and incoming/out going cable connections with required size of cable lugs with proper crimping. Make :- DVEPL, Siemen,JAIMA ELECTRICALS ,ELECTRICFIELD as Approved |
| 2 | Taking down and Supply and Fixing of ACB 4 pole 630 Amps, 4 Pole, 415 V, with Thermal Magnetic Release manual draw out type complete all as specified & directed. |
| 3 | Ditto All as per item srl No 02 above but here in ACB 4 pole 800 Amps, 4 Pole, 415 V, with Thermal Magnetic Release manual draw out type complete all as specified & directed. |
| 4 | Taking down and S&F MCCB 4 Pole 100 Amp rating, 16 KA breaking capacity with adjustable magnetic setting, 415 Volt complete all as directed. |
| 5 | Taking down and S&F MCCB 4pole 125 Amp rating, 16 KA breaking capacity with adjustable magnetic setting with spreader at both side complete all as directed. |
| 6 | Taking down and S&F MCCB 4 pole160 Amp rating,36 KA breaking capacity with adjustable magnetic setting with spreader at both side complete all as directed. |
| 7 | S&F MCCB 4 pole 200 Amp rating, 36 KA breaking capacity with adjustable magnetic setting with adjustable magnetic setting with spreader at both side complete all as directed. |
| 8 | S&F MCCB 4 pole 250 Amp rating, 36 KA breaking capacity with adjustable magnetic setting with spreader at both side complete all as directed. |
| 9 | S&F Microprocessor based MCCB 4pole 250 Amp rating, 36 KA breaking capacity with adjustable magnetic setting with spreader at both side. |
| 10 | S&F Microprocessor based MCCB 4 Pole 400 Amp rating, 36 KA breaking capacity with spreader at both side complete all as directed. |
| 11 | S&F MCCB 630 Amp rating, 50 KA breaking capacity with adjustable magnetic setting with both side spreader for cable connection complete all as directed. |
| 12 | S&F MCB TPN 40 Amp to 100 Amp, 10 KA 'C' series, 415 volt complete all as directed. |
| 13 | S&F MCB SP 06 Amp to 32 Amp, 10 KA 'C' series, 240 volt, complete all as directed. |
| 14 | S&F MCB SPN 40 Amp to 63 Amp, 10 KA, 'C' series, 240 volt complete all as directed. |
| 15 | Taking down of old U/S LT panel & Supply, installation, commissioning and testing new LT Panel Board CPRI Approved of minimum size 1.2Mtr(height) x1.0Mtr (breadth) x 0.4 Mtr (depth) factory made, weather, dust & vermin proof outdoor cubical compartmental type, Double door, front and back side openable, with providing rubber/PVC gasket of suitable size all sides of door, with Aluminium busbar wrapped with PVC tape/sleeves with maintained the colour code and Aluminium strip busbar of suitable size to MCCB input and MCCB output of suitable length for connection of cable from main busbar, made out of 2.00 mm thick mild steel CRCA sheet with 40 x 40 x 6mm size angle iron supporting frame and MC 75 channel base including applying two coats of Powder coated paint over exposed external & internal surfaces suitable for 3 phase 4 wire system 415/440 volts grade including complete connections of all outgoing / incomming existing cable of any size drawing / digging out cable from loops in trenches outside the substation building inclusive of necessary excavation and earthwork as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size of lugs and cable gland for all cable terminal connections of cables and fixed with suitable size nuts and botls of size as directed and embedded in PCC 1:2:4 as in foundation of size as required in cement mortar 1:6 and plastering the same in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed comprising of the following fitment accessories :- |
| 16 | Busbar |
| 17 | (a) Aluminium busbar of capacity 800 Amps wrapped with PVC sleeves having with maintained the colour code and provision of making holes with brass nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos. |
| 18 | INCOMING(a) ACB TPN 800 Amps, 4 Pole, 415 V, with Thermal Magnetic Release manual draw out including all fixing accessories with both ends spreader links - 01 No. (Make :- Legrand /Indoasian/ Havells) |
| 19 | OUTGOING:(a) MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 36 KA breaking capacity, rating 400 Amps including all fixing accessories with both ends spreader links -02 No. (Make :- Legrand /Indoasian/ Havells)(d) MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 36 KA breaking capacity, rating 250 Amps-01 nos and 200 Amp 4 pole 25 kA- 02 Nos including all fixing accessories with both ends spreader links -04 No. (Make :- Legrand /Indoasian/ Havells)(h) Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No. |
| 20 | Supply, installation, Testing and commissioning and testing LT Busbar Panel Board CPRI Approved of minimum size 1.2Mtr (height) x1.0Mtr (breadth) x 0.4 Mtr (depth) factory made, weather, dust & vermin proof outdoor cubical compartmental type, Double door, front and back side openable, with providing rubber/PVC gasket of suitable size all sides of door, with Aluminium busbar wrapped with PVC tape/sleeves with maintained the colour code and Aluminium strip busbar of suitable size to MCCB input and MCCB output of suitable length for connection of cable from main busbar, made out of 2.00 mm thick mild steel CRCA sheet with 40 x 40 x 6mm size angle iron supporting frame and MC 75 channel base including applying two coats of Powder coated paint over exposed external & internal surfaces suitable for 3 phase 4 wire system 415/440 volts grade including complete connections of all outgoing / incomming existing cable of any size drawing / digging out cable from loops in trenches outside the substation building inclusive of necessary excavation and earthwork as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size of lugs and cable gland forall cable terminal connections of cables and fixed with suitable size nuts and botls of size as directed and embedded in PCC 1:2:4 as in foundation of size as required in cement mortar 1:6 and plastering the same in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed comprising of the following fitment accessories :-Busbar (a) Aluminium busbar size 100 mmx 10 mm of capacity 240 Amps wrapped with PVC sleeves having with maintained the colour code and provision of making holes with brass nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos. |
| 21 | Material and labour for repair to any type of existing LT Panel board (indoor/ outdoor) with cutting necessary rusted portion of MS Sheet Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment with riveted, bolted or welded attachment providing MS Sheet of 2mm/3/15 mm of existing size and hinges to broken doors etc fixed with welding complete all as directed. |
| 22 | Material and labour for repair to any type of LT Panel board with Joist, channel, Hinges, (kabza) angle, or tee sections, fixed independently, without connecting plates, etc fixed with welding for panel maint for smooth opening /closing complete all as directed. |
| 23 | Material and labour for preparation of existing surface of Feeder pillar box /Junction Box/LT Panel and apply two coat of synthetic enamel paint all as specified and directed |
| 24 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 70 Sqmm 3.5 core with all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. (NOTE: Earthwork & Excavation, GI pipe brick protection etc shall be measured and paid separately under relevant items of this schedule 'A' part). |
| 25 | Ditto All as per ser item No 24 above but of cross sectional area 95 sqmm 3.50 core |
| 26 | Ditto All as per ser item No 24 above but of cross sectional area 120 sqmm 3.50 core |
| 27 | Ditto All as per ser item No 24 above but of cross sectional area 150 sqmm 3.50 core |
| 28 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out in any type soil complete all as specified and directed. |
| 29 | Returning, filling in including, spreading, levilling,watering and well ramming in layers not exe 25 cm thick each complete all as specified and directed. |
| 30 | Removing excavated material to a distence not exc 50m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 31 | Supply and laying dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (Note : only punned thckness will be measured) |
| 32 | Supply and laying for sub class B brick common burnt clay of size 230mm x 115mm x 75 mm for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed. |
| 33 | M & L for horizontal boring across the existing road by mechanical machinery without disturbing the road surface for inserting 80 mm bore GI pipe all complete all as specified and as directed. ( Note :- GI pipe will be measured and paid respective item of sch 'A'). |
| 34 | M&L 80 mm bore steel tubing medium grade ISI marked for protection of cable in trench including necessary joints complete all as specified and as directed. |
| 35 | Supply and fixing of LT indoor/out door Heat Shrink type 1100 Volt Jointing kit 70-120 Sqmm, 3.5 core after taking down old one.All as Specifed and directed |
| 36 | Supply and fixing of LT straight through Heat Shrink type 1100 Volt Jointing kit 70-120 sq mm,3.5 core after taking down old one. All as Specifed and directed |
| 37 | Supply and fixing of LT indoor/out door Heat Shrink type 1100 Volt Jointing kit 150-185 Sqmm, 3.5 core after taking down old one. All as Specifed and directed |
| 38 | Supply and fixing of LT straight through Heat Shrink type 1100 Volt Jointing kit 150-185 sq mm, 3.5 core after taking down old one. All as Specifed and directed |
| 39 | Material and labour for earthing complete with galvanised steel plate electrodes of size 600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised 25x4 mm earth strip by means of nuts bolts check nuts GI washers earth wire protected by galvanised iron pipe 25 mm bore (Medium grade) for poles/lightening arrestors/GO Switch/transformer/ panel including connecting to HToverhead lines all as directed including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm diameter MS bar finnel wire mesh 20 mm bore galvanised iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 5 of SSR Part I including testing on completion all as specified and directed. |
| 40 | S&F GI Strip 32x6 mm burried underground/ fixing along wall/ roof etc including with insulators, screw, saddle, for roof conductor /down conductor and connecting with test point properly on existing Accn incl dismantling and taking down unsv one complete all as specified and directed |
| 41 | M & L for PCC 1:4:8 type D2( using 40mm graded and waste of necessary formwork as required. All as specified and as directed. |
| 42 | M & L for PCC 1:3:6 type C1 (using 20mm graded crushed stone aggregate) for coping of poles including use of formwork. All as specified and as directed. |
| 43 | Supply and fix cable route indicator made out of RCC/PRECAST COCREATE ROUTE INDICATOR OF SIZE 900mmx150mmx100 mm (As approved by Engr-in-charge) and writing cable direction, Nature of cable (i.e HT/ LT MRS,Sub station etc.), size of cable (in SQMM) ,type of cable (HT/LT cable) with including fixing in PCC 1:4:8 type D2 ( using 20 mm graged stone aggregate) in ground all as specified and as directed |
| 44 | S&F in replacement weather proof flat twin Core PVC insulated & sheathed Aluminium stranded conductor cables 6 sqmm 2 core of length 90 mtr each roll complete all as specified and directed. |
| 45 | S&F in replacement PVC Insulated Single Core Unsheathed Industrial Flexible Cable 2.5 Sqmm (RYB and Black) conforming to IS 694:2010 with Bright Annealed Copper Conductor for Voltage Grade 1100 VoltsFRL S 100 mtr Roll to use as control cable for breaker/ CT PT Panel Complete all as specified and directed, |
| 46 | Routine periodical maintenance/servicing as and when required and testing of UPS 5 KVA to 30 KVA capacity single phase/ three phase complete including all consumables items like cotton, waste cloth, kerosene oil etc.Maintenance will be carried out as all directed by Engr-in-Charge and comprising of the following :-(a) Cleaning all parts and card.(b) Cleaning cooling fan.(c) Top up battery distil water |
| 47 | Supply and fix in replacement of Batteries (VRLA / Li-ion / Tubular, depending on model) of capacity 12 Volt 180/200Ah as per existing make and model as in approved complete all as specified and directed. Please Enable Macros to View BoQ information |
| 48 | Supply and fix in replacement of Batteries (VRLA / Li-ion / Tubular, depending on model) of capacity 12 Volt 180/200Ah as per existing make and model as in approved complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 18, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysDec 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓