Drinking Water Supply and Sanitation Government Departments Closing in 5 days TDR #58582470

Tender For Repairing Of Leakages / Bursts And Interconnection Works Of Ac/Ci/Di/Pvc Pipe Lines Of Various Sizes In Uwss Gangapur (Annual Rate Contract)

Issued by Government Departments · Bhilwara, Rajasthan
Tender Value
8 Lakhs
Estimated cost
Bid Submission
27 Nov 2026
5 days left
EMD
16000
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bhilwara → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repairing Of Leakages / Bursts And Interconnection Works Of Ac/Ci/Di/Pvc Pipe Lines Of Various Sizes In Uwss Gangapur (Annual Rate Contract)

BOQ

Name of Work:- Repairing of leakages / bursts and interconnection works of AC/CI/DI/PVC pipe lines of various sizes in UWSS Gangapur (Annual rate contract)
Sl. No. Item Description
1Repairing of leakage in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including taking out the burst pipe from trench, dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material, tightening of CID Joints to make repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of material required from Jen store. (Required material such as pipe piece, CID Joints shall be provided by Department free of cost)
2In all type Soil AC/PVC/HDPE pipe
350/63/75mm
480/90mm
5100/110mm
6125/140mm
7150/160/180mm
8200/225mm
9Add 5% EXTRA on above item no. 1 for B.T. Road
10Add 15% EXTRA on above item no.1 for CC Road. Pit in CC Road shall be cut in optimum size through CC Cutter machine only
11Add 20% EXTRA on above no. 1 item if depth of pipeline is above 1.5 mtr and up to 3.0 mtr.
12Repairing of leakage in existing Distribution/Rising Main/Transmission Main CI/MS/DI pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at at site of work including taking out the burst pipe from trench, dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material, tightening of CID Joints to make repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of material required from Jen store. (Required material such as pipe piece, CID Joints shall be provided by Department free of cost)
13In all type Soil
14100mm
15125mm
16150mm
17200mm
18Add 5% EXTRA on above item no. 2 for B.T. Road
19Add 15% EXTRA on above item no.2 for CC Road. Pit in CC Road shall be cut in optimum size through CC Cutter machine only
20Add 20% EXTRA on above no. 2 item if depth of pipeline is above 1.5 mtr and up to 3.0 mtr.
21Minor repair of leakages such as lead caulking, plugging, clamping and ring fixing in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE/CI/MS/DI pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site to make repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as lead wool, white hump, plugs, clamps etc. shall be provided by Department free of cost)
22In all type Soil
2350/63/75mm
2480/90mm
25100/110mm
26125/140mm
27150/160/180mm
28200/225mm
29Add 5% EXTRA on above item no. 3 for B.T. Road
30Add 15% EXTRA on above item no.3 for CC Road. Pit in CC Road shall be cut in optimum size through CC Cutter machine only
31Add 20% EXTRA on above no.3 item if depth of pipeline is above 1.5 mtr and up to 3.0 mtr.
32Replacement of CI/ DI Double flange sluice valves,non return valves,butter fly valves etc. in existing Distribution/Rising Main/Transmission Main pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including providing and fixing MS Nut and Bolt and rubber gasket, dewatering and providing adequate safety arrangement at site and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as Valve, Tail piece, CID Joints etc. shall be provided by Department free of cost)
33In all type Soil
3480 mm
35100 mm
36125 mm
37150 mm
38200 mm
39Add 5% EXTRA on above item no. 4 for B.T. Road
40Add 15% EXTRA on above item no.4 for CC Road. Pit in CC Road shall be cut in optimum size through CC Cutter machine only
41Add 20% EXTRA on above item no. 4 if depth of pipe line is above 1.5 mtr to 3.0 mtr
42Deduct 20% on above item no. 4 if valve is fixed at plinth level / platform i.e. no excavation is required
43Removal of Choking from pipe line, including tree roots, malba, sand and other by manually or other means, cleaning of line and testing in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE/uPVC pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as pipe piece CID Joints shall be provided by Department free of cost)as per satisfaction of EIC. Rates for per pit.
44In all type Soil
4575 mm
4690/80 mm
47110/100 mm
48140/125 mm
49180/160/150 mm
50225/200 mm
51Add 5% EXTRA on above item no. 1.5 for B.T. Road
52Add 15% EXTRA on above item no.1.5 for CC Road. Pit in CC Road shall be cut in optimum size through CC Cutter machine only
53Add 20% EXTRA on above item no. 1.5 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr.
54Removal of Choking from pipe line, including tree roots, malba, sand and other by manually or other means, cleaning of line and testing in existing Distribution/Rising Main/Transmission Main CI/MS/DI pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as pipe piece CID Joints shall be provided by Department free of cost)as per satisfaction of EIC. Rates for per pit.
55In all type Soil
5680 mm
57100 mm
58125 mm
59150 mm
60225/200 mm
61Add 5% EXTRA on above item no. 6 for B.T. Road
62Add 15% EXTRA on above item no.6 for CC Road. Pit in CC Road shall be cut in optimum size through CC Cutter machine only
63Add 20% EXTRA on above item no. 6 if depth of pipe line is above 1.5 mtr up to 3.0 mtr.
64Disconnection of water connection from existing pipe line in all type of soils up to 1.5 mtr depth by digging out suitable size of pit at site of work, with cutting of service line and refixing of clamp revolving it 180 degree refill the pit from excavated sand by ramming it & upto ground level for entire job contractor will use his own T&P & labour.
65Add 5% EXTRA on above item no. 7 for B.T. Road
66Add 15% EXTRA on above item no.7 for CC Road. Pit in CC Road shall be cut in optimum size through CC Cutter machine only
67Add 20% EXTRA on above item no. 7 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr
68Removal of sluice valve in existing pipe line up to 1.5 mtr depth by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material to make repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as pipe piece CID Joints shall be provided by Department free of cost)
69In all type Soil
7080 mm dia pipe to 100mm
71125 mm dia pipe to 150mm
72200 mm dia pipe to 250mm
73Add 5% EXTRA on above item no. 8 for B.T. Road
74Add 15% EXTRA on above item no.8 for CC Road. Pit in CC Road shall be cut in optimum size through CC Cutter machine only
75Add 20% EXTRA on above item no. 8 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr
76Work of Inter Connection in AC/PVC/HDPE pipe line up to 1.5 mtr depth by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site, cutting of existing pipeline, jointing of Tee (complete) and other specials to make inter connection repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of material required from store. (Material such as Tee/ Tee Clamp/rubber sheet/ CID joints required for inter connection shall be provided by the department free of cost).
77In all type Soil
7880 mm to 110 mm
79125 mm to 165 mm
80200 mm to 300 mm
81Add 5% EXTRA on above item no. 9 for B.T. Road
82Add 15% EXTRA on above item no.9 for CC Road. Pit in CC Road shall be cut in optimum size through CC Cutter machine only
83Add 20% EXTRA on above item no.9 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr
84Work of Inter Connection in CI/DI/MS pipe line up to 1.5 mtr depth by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site, cutting of existing pipeline, jointing of Tee (complete) and other specials to make inter connection repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of material required from store. (Material such as Tee/ Tee Clamp/rubber sheet/ CID joints required for inter connection shall be provided by the department free of cost).
85In all type Soil
8680 mm to 100 mm
87125 mm to 150 mm
88200 mm to 300 mm
89Add 5% EXTRA on above item no.10 for B.T. Road
90Add 15% EXTRA on above item no.10 for CC Road. Pit in CC Road shall be cut in optimum size through CC Cutter machine only
91Add 20% EXTRA on above item no.10 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr
92Labour charges for removal of complaint of polluted water supply to the consumers
93Survey of the locality of polluted water supply for preliminary assessment of source of pollution during supply hours
94Labour charges for digging of pit of suitable size for removal of water pollution on existing distribution AC/PVC/uPVC/HDPE pipe lines up to 1.5 mtr depth including cutting of pipe and assessment of direction of flow of polluted water during non supply hours, identifying the source of pollution and repairing of fault in pipe line by fixing of pipe piece with jointing material (pipe and jointing material shall be supplied by department) to make it leak proof and then refilling the pit from excavated sand by ramming it at site of pipe upto ground level. The rate includes all labour charges to complete the work for pipe size
95In all type Soil
9650 to 75 mm
9780-110 mm
98125 to 165 mm
99200 to 300 mm
100Add 5% EXTRA on above item no.12 for B.T. Road
101Add 15% EXTRA on above item no.12 for CC Road. Pit in CC Road shall be cut in optimum size through CC Cutter machine only
102Add 20% EXTRA on above item no. 12 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr.
103Labour charges for digging of pit of suitable size for removal of water pollution on existing distribution CI/DI/MS pipe lines up to 1.5 mtr depth including cutting of pipe and assessment of direction of flow of polluted water during non supply hours, identifying the source of pollution and repairing of fault pipe line by fixing of pipe piece with jointing material (pipe and jointing material shall be supplied by department) to make it leak proof and then refilling the pit from excavated sand by ramming it at site of pipe upto ground level. The rate includes all labour charges to complete the work for pipe size
104In all type Soil
10580-100 mm
106125 to 150 mm
107200 to 300 mm
108Add 5% EXTRA on above item 13 for B.T. Road
109Add 15% EXTRA on above item no.13 for CC Road. Pit in CC Road shall be cut in optimum size through CC Cutter machine only
110Add 20% EXTRA on above item no.13 if depth of pipe line is above 1.5 mtr and up to 3.0 mtr.
111Restoration of bitumen road by patch work of WBM using crushed / broken aggregate as per the standard specification and consolidation with hand rammer spreading and consolidation of binding material , cleaning of surface of WBM and providing of seal & tack coat as per site condition by using ready cold mix up to the satisfaction of engineer in charge. The rate includes the making of pit in regular shape, all labour, material and T&P charge complete job.
112Restoration of cement concrete road including making of pit in regular shape, ramming and consolidation of surface, laying, positioning and compacting cement concrete ( M-20 ) minimum thickness 200 mm upto the satisfaction of engineer incharge. The rate includes the making of pit in regular shape, all labour, material and T&P charge complete job.
113Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended up to date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M.
114HDPE PE-80 PN-6
11575 mm dia
11690 mm dia
117110 mm dia
118125 mm dia
119140 mm dia
120160 mm dia
121180 mm dia
122200 mm dia
123Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil
124Ordinary rock
125Hard rock(blasting prohibited)
126Providing, Fabrication of Mild Steel Plane Ended/ Flanged Specials like Tees, Bends, Reducers, Enlargers, Plugs, Tail Pieces and Blank Flange made from MS pipes, MS sheet strip and MS Sheet of required sizes by welding, cutting and treading as per site conditions and as directed by the Engineer- In- Charge complete in all respect. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58582470
AUTHORITY Government Departments
TENDER VALUE 8 Lakhs
LAST DATE 27-11-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Repairing Of Leakages / Bursts And Interconnection Works Of Ac/Ci/Di/Pvc Pipe Lines Of Various Sizes In Uwss Gangapur (Annual Rate Contract)
Basic Detail
Tender No 37-38/26-27 City Div Bhilwra
Bidding Type Tender
Location
City Bhilwara
State Rajasthan
Key Dates
Publish Date 18 Nov 2026
Submission Date 27 Nov 2026
Open Date 27 Nov 2026
Finance
Tender Value 8 Lakhs
Tender Fee 1000
EMD 16000
Exemption Available
Document List
38.pdf
aa305f0c-7b76-4642-b1b1-700b2f592ae9.html
BOQ_1074938.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Nov 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
pdf

38.pdf

html

aa305f0c-7b76-4642-b1b1-700b2f592ae9.html

xls

BOQ_1074938.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender