Housing Urban and Rular Development Government Departments Closing in 3 days TDR #58580800

Tender For Maintenance And Payment Of Electrical Consumption Charges Of Street Lighting On Pwd Roads Under North Zone, Delhi. (Sh: Supply Installation Testing and Commissioning of Storm Water Management System At Madhuban Chowk Underpass And Prembari

Issued by Government Departments · Delhi, Delhi
Tender Value
88.74 Lakhs
Estimated cost
Bid Submission
25 Nov 2026
3 days left
EMD
1.77 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Maintenance And Payment Of Electrical Consumption Charges Of Street Lighting On Pwd Roads Under North Zone, Delhi. (Sh: Supply Installation Testing and Commissioning of Storm Water Management System At Madhuban Chowk Underpass And Prembari Pul Underpass)

BOQ

Name of Work:- Maintenance and Payment of electrical consumption charges of street lighting on PWD Roads under North Zone, Delhi. (SH: SITC of Storm Water Management System at Madhuban Chowk Underpass and Prembari Pul Underpass)
Sl. No. Item Description
1Fabrication, supplying, installing, testing and commissioning of indoor type free standing weather and vermin proof flush compartmentalized modular, totally enclosed type electrical starter panel (as per general arrangement size not less than 4 sq. mtr. and 0.45m deep made out of 2.0mm thick sheet steel with front and back hinged openable double leaf doors with panel lock including supplying and fixing following accessories inside the panel, drilling, welding, providing detachable gland plate / knock outs plate, connections, as required. The cubical board shall be provided with base channel of (ISMV 100 designation) of size 50*50mm including painting the base channel with primer and finish paint, complete as per general arrangement drawing approved by Engineer-in-charge. The LT panel shall generally confirm to CPWD General Specifications for Electrical works, Part-1,Internal 2005, Part-2 External 1994 and Part-4 substation equipment-2007 as amended upto date.a) 6 Amps SP CONTROL MCB = 15 Nos.b) 10 Amps DP CONTROL MCB = 4 Nos.c) 400 A, 50KA FPMCCB = 1 No.d) 100 A, 36KA TPMCCB = 3 Nos. e) 125A, 36KA TPMCCB = 1 No.f) Spreader Terminal 4 Poleg) Spreader Terminal 3 Poleh) Direct ROM = 4 Nos.i) R-Y-B Indication Lampj) VAF+PF METERk) CT COIL 400/5l) CT COIL 100/5m) PUSH BUTTON WITH ELIMENTn) 230/24V, DC 8.2A SMPS = 1 No.o) 4 CHANNEL RELAY CARD = 1 No.p) AUTO/MANUAL SELECTER SWITCH = 4 Nos.q) 400 A Changeover = 1 Nos.r) 30 HP VFD = 4 Nos.s) 75 HP VFD = 1 Nos.t) 4\\" Cooling Fan = 4 Nos.
2Supplying, installation, testing & Commissioning of ultrasonic sensor in each water storage tank with measuring range upto 5 meters measurement accuracy of 0.5% - 1.0%, Resolution ratio of 3mm or 0.1% (whichever is greater) with LCD digital Display, Analog output of - 4-line system with 4-20mA current, 510 Ù load, 2-line system, 4- 20mA, 250 Ù load with Relay output - 2 group (i.e. AC 250V/8A or DC 30V/5A) with 24VDC supply, Ambient temperature Display instrument - 20~+60°C with IP66 protection etc complete as reqd.
3SITC of Microprocessor Unit DIN mounted hardware having a Cortex-M3 core microcontroller operating at up to 72 MHz on 3.3 V logic (2.0 V to 3.6 V), with minimum 64 KB on-chip Flash and 20 KB SRAM for firmware, settings and data buffers, minimum 3 nos. USART (used for RS485 and debug), 2 nos. I2C, 2 nos. SPI, general purpose timers, a 12-bit ADC and minimum 30 nos. programmable GPIO for inputs, relay driving and indication. An SWD debug interface, real time clock support and a watchdog timer for automatic recovery from hang-up, programmed in-circuit through SWD. Having built-in Wi-Fi module with 32-bit processor core running at 80 MHz (up to 160 MHz), an integrated TCP/IP protocol stack and minimum 4 MB Flash memory. IEEE 802.11 b/g/n standard in the 2.4 GHz band with a data rate of up to 72.2 Mbps, supports WPA / WPA2 personal security, and operates in station mode, connecting to the site Wi-Fi router with a configurable IP address. Transmit power of up to +20 dBm, receiver sensitivity better than -90 dBm, interfaced to the microcontroller through UART with automatic reconnection to the Wi-Fi network on loss of connection. The unit communicates with the site software through TCP based command / response messages, and any loss of communication is detected and reported to the software.Having 3 nos. opto-isolated inputs and an RS485 interface. A SWD port and I2C Having port. 3 nos. power relays rated 10 A at 250 VAC and 10 A at 24 VDC. Having LED indication for power and relay status.Including common Android based touch screen display with Site Automation Software - Storm Automation for online monitoring and automatic control of pump house of site, having following display features, settings and logic for each piece :-Overview: The display shall run the site automation software continuously and shall act as the local gateway between the field controller units and the server. It shall be connected to the same local Wi-Fi network as the controller units, communicate with all controller units, execute the automatic control logic, and upload all data to the server, from where it shall be displayed, controlled and reported through the web based SCADA software. The site shall continue to operate automatically even if the internet connection is lost.➢ Wi-Fi and SIM status shall be shown on the dashboard, and the internet status shall be reported to the server with the health data.Dashboard: The dashboard shall display:➢ Live time, Wi-Fi connection status with network name, SIM / mobile data status, and battery percentage with charging status.Service status with start time, Loop status with start time and loop count, Command panel with executed / pending command count and last command status, Operating mode indicator (Auto / Manual), Menu for Start Service, Stop Service, Lock / Un-Lock Device, App Setting, System Setting, Log View, Site Design, Switch System Mode, Upgrade Application and Restart Application.Security: All settings screens shall be password protected. The display shall provide change password, reset application data and device lock / unlock facility.SETTINGSThe display shall provide the following settings:Hardware setting - connection timeout and read timeout for pump, valve and tank, and pump ON command, Tank level setup - tank IP and multiple level sets, each defining which pumps run at that level, Pump naming setup - pump IP, pump name and pump rated current (Amp). The rated current shall be used by the software to detect dry run of the pump, Pump priming time - priming time for each valve, Debug mode, single service run, upload data to server, start service with application. Stop all pumps at base level, stop all pumps at service start, stop pump at maximum pump run time, Maximum pump run time, pump priming duration, pump priming minimum tank level, pump delay on tank low, and Location ID.Automatic Control: The software shall contain the following control logics: Pump Rotation Logic, Pump Trip Logic, Base Tank Logic, Valve Logic, Auto Pump OFF, Dry run protection using pump current (pump stopped and next pump in rotation started), Auto and Manual mode of operation, Commands received from SCADA shall be executed and the response sent back to the server.
4Design , Supply & installation of SCADA software for online monitoring and control of pump house of site with following specification:-Overview: The SCADA software shall provide comprehensive real-time monitoring, control, and data management for the water distribution system. It will enable users to remotely view and manage the system from anywhere using a web browser, with secure user login and a multi-site dashboard.SCADA Software with Server Validity of 3 YearsKey Features:Secure Access & Multi-Site Dashboard: Secure username/password login with change-password facility. The home dashboard shall display Total, Online and Offline devices and a Pump House Location List showing Location ID, Location Name, Last Data Received time and Online/Offline status for every site. From the list the user can open the Live UI, Live Data, Reports and Settings of each site. Dashboard and data pages shall auto-refresh with a configurable refresh time, and shall support search, sorting and pagination.Real-Time Data Monitoring: Displays real-time status and parameters of all system components, including pumps, sensors, flow meters and valves.User Interface (UI): A user-friendly, customizable live UI that shows the current status of all system components.The UI shall provide basic functions for supervision and control of the system.The UI shall give the user access to alarms and events displayed on the screen. Aside from these lists on the screen, there shall be a printout of alarms or events in an event log.The following standard pictures shall be available from the UI.➢ Graphical process diagram showing the Hardware status - pumps (colour-coded by running / stopped / fault state), valves, flow meters, sensors and tank with live water level in percentage, along with the last command and last update time.➢ Pop up box to display pump details like Update Time, IP, Name, Status, Voltage (V1/V2/V3), Current (I1/I2/I3), Power, Frequency, Power Factor, Power consumption (Unit) and Error.➢ Alarm list, station➢ Event list, station➢ System status (controller health).Alarm List: The software shall generate and display alarms on screen in real time, with the alarm type, hardware name, IP, status and time of occurrence, including:➢ Pump fault / trip / error.➢ Loss of communication with pump, valve, sensor, flow meter or controller.➢ Tank level low / high.➢ Valve fault or abnormal position.➢ Flow meter abnormal reading or no-flow condition.➢ Sensor failure or out-of-range value.➢ Controller health alarms such as WiFi / internet disconnected, service stopped or low battery.Alarms shall be available as a printable / downloadable log and shall be filterable by date and time, hardware and status.Flow Meters, Valves and Sensors: The software shall monitor and display:➢ Flow meters - live flow rate and totalised flow.➢ Valves - Open / Close status, with remote Open and Close commands.➢ Tank level sensor - live level shown as percentage and graphically on the tank.➢ Other sensors installed in the system - live values with status.Pump, valve, tank and sensor connection timeout and read timeout shall be configurable from the Hardware Settings page.Remote Command Execution: Enables users to issue remote commands for controlling pumps, sensors and valves (ON, OFF, OPEN, CLOSE, STATUS, AUTO, MANUAL, SERVICE START and SERVICE STOP). In order to ensure a high degree of security against undesired operation, a \\"select-before-execute\\" command procedure shall be provided. The operator selects the hardware type, then the device IP, then the command, with a configurable command timeout. After the \\"selection\\" of a hardware, the operator shall be able to recognize the selected device on the screen and all other hardware shall be blocked. As communication between control centre and device to be controlled is established, the operator shall be prompted to confirm the control action and only then final execute command shall be accepted. After command execution the user shall receive a confirmation that the command is executed, and the device response shall be shown in the Command List with command time, response time and response received time. The system shall support AUTO and MANUAL application modes. In the selected object picture, all attributes like➢ Authority➢ Local / remote control➢ Errors etc. shall be displayed.Live Data & Controller Health Monitoring: The Live Data page shall show the incoming and outgoing communication of each site in real time (IP, control, hardware, command and status). The Live Health Data page shall show the on-site controller's App Status, App Mode, Service Status, Service Loop Count, Battery Charging Status, Battery Percentage, WiFi Status, WiFi Name and Internet Status.Automation & Settings: The software shall provide settings for automatic pump operation, including:➢ Maximum pump run time, pump priming duration and pump priming minimum tank level.➢ Pump delay on tank low level.➢ Stop all pumps at base level, at service start and at maximum service runtime.➢ Start service with application, upload data to server and debug mode.➢ Pump ON command and client ID configuration.➢ Data refresh time for web pages.Event Data Management: Allows users to download and analyse historical event data logs.The Report page shall contain all the commands that are executed for the control and monitoring of the water distribution system.The event and associated time of its occurrence has to be displayed for each event. The event page shall be automatically updating at real time within maximum of 10sec duration. The operator shall be able to call up the event list on the monitor at any time for the whole water distribution system or sections of it. The events shall be registered in a chronological event list in which the type of event and its time of occurrence are specified. It shall be possible to store all events in the computer for at least one year. The Report page shall be download in pdf and excel format. The Report can be viewed/download in web browser by selection of date and time in From and to format between 1-year period.The following reports shall be available:➢ Event Report - filtered by hardware, IP address and status.➢ Command Report - filtered by hardware, IP address and command.➢ Health Report - controller health history.➢ Alarm Report.The chronological event list shall contain:➢ All Hardware of system like - pumps, sensor, valve, flow meter.➢ All Pumps parameter like Voltage, Current, Power Factor, Power consumption etc installed in the system.➢ All sensor values installed in the system.➢ All Valve status installed in the system.➢ All Flow meter readings installed in the system.➢ Loss of communication.➢ Filters for selection of a certain type or group of events shall be available. The filters shall be designed to enable viewing of events grouped per:➢ Date and time.➢ Hardware➢ Status
5Providing & Fixing of WiFi router for monitoring of pumps with the following specifications:-A) External Power Supply: 9VDC/0.6AB) Interface:-i) 4 10/100Mbps LAN Ports: ii) 1 10/100 Mbps WAN Portsiii) Dimension: 7.6 x 5.3 x 1.3 in. (193 x 134 x 33mm)iv) Antenna: 2.5dBi Fixed Omni Directional Antennav) Wireless Function: Enable/Disable Wireless Radio, WDS Bridge, WMMvi) Wireless security: 64/128/ 152-bit WEP/ WPA/ WPA2,WPA-PSK/WPA2-PSKvii) Freequency: 2.4-2.4835GHz
6Providing, Installing, Testing & Commissioning of Storm Water SCADA Software Integration with existing centralized PWD headquaters, including supply and configuration of SCADA server, workstation, communication gateways, industrial networking equipment, VPN and firewall setup, creation of centralized SCADA database, tag mapping of field instruments, microprocessor communication programming through Modbus TCP/IP, OPC and Ethernet protocols, development of graphical HMI mimic screens, real-time data acquisition, alarm and event management, historical data logging, trend analysis, report generation, remote operation and control of pumps, motorized valves and field devices, integration of level sensors, flow meters, and electrical parameters, configuration of user access levels, cybersecurity implementation, redundancy and backup setup, server commissioning, communication testing, FAT/SAT, system validation, operator training and all associated hardware, software, engineering services, cabling and accessories required for complete centralized monitoring and control of the Storm Water System from MSO Building Headquarters
7Supplying and drawing of following size FR PVC insulated single core & multi core sheathed/unsheathed industrial flexible copper conductor cable of 1100V grade complete as required.a) 4 x 1 sq. mm
8Supplying and Laying of XLPE, Copper armored conductor cable in the existing pipe as reqd i/c termination of cable with suitable size thimble at both end etc as required complete at site. a) 3 x 16 sq.mm
9Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.a) Above 35 sq. mm and upto 95 sq. mm
10Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required
11Supplying and laying 6 SWG G.I. wire at 0.50 Meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58580800
AUTHORITY Government Departments
TENDER VALUE 88.74 Lakhs
LAST DATE 25-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Maintenance And Payment Of Electrical Consumption Charges Of Street Lighting On Pwd Roads Under North Zone, Delhi. (Sh: Supply Installation Testing and Commissioning of Storm Water Management System At Madhuban Chowk Underpass And Prembari Pul Underpass)
Basic Detail
Tender No 73/EE(E)/NWED/PWD/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 17 Nov 2026
Submission Date 25 Nov 2026
Open Date 25 Nov 2026
Finance
Tender Value 88.74 Lakhs
Tender Fee Ref. Documents
EMD 1.77 Lakhs
Exemption Available
Document List
2f6fd0d2-f4b9-4364-bc86-27a0dd4a42fa.html
BOQ_402405.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Nov 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

2f6fd0d2-f4b9-4364-bc86-27a0dd4a42fa.html

xls

BOQ_402405.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender