Tender for Refurbishment/Reconstruction Of Rooms At New Purnima Building And Allied Civil Works At Sea Side Buildings, North Site, Barc, Trombay, Mumbai.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work excavation by mechanical means (Hydraulic excavator) / manual means in foundation, in all types of soil other than soft and hard rock, dressing the sides of foundation,ramming of bottom of foundations etc. including shoring and dewatering (if necessary) and refilling around foundations and plinth with selected excavated earth in layers of not more than 500 mm thick, each layer well rammed and consolidated including disposing the surplus earth within a distance of 200 m all as per specifications and as directed by the Engineer-in-charge. From 0.00 to 1.50 m depth from Average Ground Level. |
| 2 | Dismantling old plaster / skirting, raking out joints & cleaning, the surfaces for plaster including scaffolding, disposal of debris to the dumping ground within 100 metres lead. |
| 3 | Dismantling Aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplaus material and stacking of serviceable materials within 100 m lead as directed by the Engineer-in-Charge. |
| 4 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including scaffolding, dismantling and stacking within 100 m lead. |
| 5 | Dismantling brick work in Cement mortar carefully without damaging adjecent structures including scaffolding, stacking of materials and disposal of unserviceable materials within 100 m lead as per direction of Engineer-in-charge. |
| 6 | Dismantling Plain Cement concrete manually / by mechanical means carefully with out damaging adjecent structures including disposal of debris within 200 m lead as per direction of Engineer-in-charge. |
| 7 | Dismantling of RCC works including Cutting and stacking of steel reinforcement bars and disposal of unserviceable materials within 100 m lead as per direction of Engineer-in-charge. |
| 8 | Providing and constructing Half brick masonry using Flyash/ Flyash Lime bricks in substructure with minimum 70 kg / Sq.cm strength of approved make and size in partition walls in C.M 1:4 using crushed sand including scaffolding, raking out joints, curing etc. complete and with stiffners of RCC 1:2:4 (105 X 75 mm size) at every 900 mm height including form work curing etc. complete as per specifications but excluding reinforcement. (Reinforcement will be paid under relevant item) |
| 9 | Providing and constructing brickwork in cement mortar 1:4 using crushed sand with Flyash/ Flyash Lime bricks with minimum 70 kg/ Sq.cm strength of approved make and size in super structure above plinth up to and including Floor II level including, scaffolding, raking out joints, curing, cleaning complete all as per specifications and drawings. |
| 10 | Providing 20 mm thick plastering using Ready mix external plastering compound of approved make for external faces of brickwork / concrete surfaces including preparation of the surface, curing, cleaning scaffolding up to 10 metres height complete. all as per specifications including forming drip moulds wherever necessary and as directed by the Engineer-in-charge. |
| 11 | Providing 15 mm thick plastering using Ready mix Internal Plastering compound of approved make for internal faces of brickwork / concrete surfaces including preparation of the surface, hacking of surface, curing, cleaning, scaffolding complete all as per specifications and as directed at site by the Engineer-in-charge. |
| 12 | Providing and laying in position Reinforced Cement Concrete (RCC) of grade M-30 using 20mm maximum size aggregates and crushed sand of approved quality including admixtures of approved brand and quality (plasticiser or super plasticiser) if required, including weigh batching, mechanical mixing, transporting, placing, vibrating, consolidation, finishing, curing etc. complete but excluding the cost of centering, shuttering and reinforcement complete as per specifications up to Plinth Level. Note: The minimum cement content for RCC works should be as per the latest revision of the relevant IS code. |
| 13 | Providing and laying in position Reinforced Cement Concrete (RCC) of grade M-20 using 20mm maximum size aggregates and crushed sand of approved quality including admixtures of approved brand and quality (plasticisers / super plasticisers), weigh batching, mechanical mixing, transporting, placing, vibrating, consolidation, finishing, curing etc. complete but excluding the cost of centering, shuttering and reinforcement complete as per specifications up to Plinth Level. Note: The minimum cement content for RCC works should be as per the latest revision of the relevant IS code. |
| 14 | Providing and laying in position cement concrete of 1:3:6 (1cement, 3 crushed sand, 6 graded stone aggregate of maximum size 20 mm) including consolidation, finishing, curing etc. complete as per specifications and drawings but excluding the cost of Form work shuttering, centering Complete at all levels. Note: The minimum cement content for RCC works should be as per the latest revision of the relevant IS code. |
| 15 | Extra for PCC, RCC Using Ready Mix Concrete from outside Project area including transporting and pumping from approved batching plants . |
| 16 | Providing, centering, shuttering Form work using steel plates, timber planks for all types of structures including necessary strutting, proping, staging, supports, bracing etc and deshuttering the same after the specified time all as per drawings and specifications and as directed by the Engineer-in-charge at all levels. |
| 17 | For Sub Structure. |
| 18 | For Super Structure. |
| 19 | Supplying, stacking and laying of 230 mm thick rubble soling stones as under floor base including packing with smaller stone and compacting, ramming including spreading and consolidation of blinding material, moorum etc. complete all as per specifications and as directed by the Engineer-in-charge. |
| 20 | Providing and laying minimum 25 mm thick uniform shade Kotah stone flooring over 20 mm thick (Avearge) base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing in minimum three levels to obtain mirror polish complete with base cement mortar 1:4 (using crushed sand) all as per specifications, patterns and drawings complete. |
| 21 | Providing and Laying Minimum 25 mm thick uniform shade Kotah stone treads and risers of steps, skirting,window sills in single length up to 2.00 metres length slab dado and pillars laid on 12 mm thick (average) cement mortar 1:3 (using crushed sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing to obtain mirror finish complete as per specifications, drawings and as directed by the Engineer-in-charge. |
| 22 | Providing and fixing Minimum 15-17 mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut Granite of Jet Black colour for kitchen platforms, vanitiy counters, wash basin Counters, door Frames, window sills, facias and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (using crushed sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing the edges to give high gloss finish, scaffolding etc., complete at all levels. |
| 23 | Providing and fixing double tubular scaffolding system using H frames with cup lock type on the exterior side upto seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S clamps and M.S staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and as approved by the Engineer -in - charge. The elevational area of the scaffolding shall be measured for payment purposes. The payment shall be made once irrespective of duration of scaffolding. NOTE: The payment shall be made once, irrespective of duration of scaffolding. |
| 24 | Providing and fixing Lay in False Ceiling 600 x600mm unperforated corrosion resistant aluminium magnesium alloy metal panel fixed in 24 mm 'T' Frame work of Module 600 x 600 mm. Panels shall be manufactured of size 575 mm x 575 mm of approved colour in 0.70 mm thick Aluminium Alloy 3105 with square edges Tiles to be stove enamelled on a continuous application for pre-treatment. The coils to be go through 4 stages of pre treatment Three times of oven baked through conversion coating , priming and finish coat ensuring superior adhesion, high corrosion resistance and good colour stability.The coils to be painted on both sides after degreasing. Inside surface to have a primer of 5 microns and a coat of natural colour of 5 microns, exposed surface to have a primer of 5 microns, binder of 5 microns and a topcoat of approved colour 15 microns. Grid system for fixing ceiling tiles shall comprise of tees.The 24 mm main tee runers shall be suspended at an interval of 1200 mm centre to centre. The 24 mm cross tee runner shall be suspended at an interval of 600 mm centre to centre and further supported with 24 mm cross tee with inter locking arrangements to form a Grid of 600 mm x 600 mm. The main tee shall be supported by means of 4 mm G.I.rod from slab / roof. The suspension shall be provided at 1200 to 1500 mm centre to centre.provision for lights, diffusers etc to be made including extra supports wherever necessary. Measurements shall be as per actual area of false ceiling with out deductions for lights and diffusers. |
| 25 | Providing structural repairs in old damaged concrete structures /surfaces with approved Polymer with following operations 1) Removal of loose/Spalled or damaged concrete by chipping and cleaning the concrete surface and reinforcement steel with wire brush and with water 2) Cleaning the re bars with Acetone for complete rust removal and washing with water to make the surface clean. 3) Applying protective coat / bond coat using polymer and cement in the proportion of 1; 1.5 (1 part of polymer and 1.5 parts of cement in synthetic enamal paint like consistancy with brush 4) Reinstate the area with polymer modified mortar in layers of maximum 20 mm with the proportion of Cement 50 Kg : washed and dried river sand 87.50 kg ; silica sand 37.50 Kg. mixed with 10 litres of Polymer (or 1 Kg cement : 1.75 kg washed and dried river sand ; 0.75 Kg silica sand : 200 ml polymer). 5) If thickness of repair exceeds 20mm , after every 20 mm thick repair, bond coat as per 2 above to be applied and further thick of repair to be continued for each layer. This work is inclusive of all materials, labour, complete all as directed at site using approved polymer suitable for structural repair shall be used).Note: Scaffolding will be paid separately under relevant item. |
| 26 | Providing and Fixing 3.00 mm thick Homogeneous PVC sheet / tile in flooring and skirting of aproved make in approved pattern on a smooth and damp proof base using rubber based adhesive of approved quality and manufacturer including levelling small undulations with plasterof paris if required, rolling with light wooden roller weighing about 5 kg all complete as directed by Engineer-incharge in approved colour and shade. |
| 27 | Providing and fixing IS: 3564 marked aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. in wooden doors / steel doors with necessary bolts & nuts of approved make complete as per specifications and as directed by the Engineer-in-charge. |
| 28 | Providing and fixing mortice latch and lock of approved make with 6 levers and a pair of handles Inside opening LEFT / Right with necessary screws etc complete suitable for fixing in wooden / steel/ FRP/ doors as per specifications. |
| 29 | Providing and Painting two coats of synthetic enamel paint on steel surfaces of approved brand and manufacture to give an even shade over a primer coat including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge. |
| 30 | Providing and applying wall painting two coats on new work with premium plastic emulsion paint of approved brand to give an even shade, including a coat of approved cement primer, including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge. |
| 31 | Providing and applying white cement based wall putty of approved make over concrete or Plastered surface up to 3 mm thick to get uniform surface free from undulation including cleaning complete all as directed by the Engineer-in-charge. |
| 32 | Providing and fixing in position at 6 mm thick solid Polycarbonate sheet of approved make in aluminium framework and sealing the joints with sealant etc. including making necessary holes screws and other fixtures as required complete in all respect with EPDM gaskets as per drawings and specifications. The rate inclusive of all materials, consumables, scaffolding and labour charges etc.( Note: End to end portion measurement will be considered for payment & shop drawing to be submitted by contractor before execution of work). Note: The required frame work for the supporting structure will be paid under relevant item. |
| 33 | Providing Reinforcement Steel for reinforced cement concrete at all levels including supplying, preparation of bar bending schedules, cutting, bending, transporting, fixing, tieing in position with PVC coated with 1.6 mm dia soft drawn annealed G.I binding wire, all labour charges, cost of cover blocks in specified grade of concrete etc. etc. complete including cost of binding wire, complete as per specifications and drawings. - Steel supplied by the contractor.Notes : 1. The contractor shall supply documentary evidence of purchase of steel, Test certificate from approved manufacturers and also testing third party from approved laboratories with out any extra cost. 2. Binding wire required for the work will have to be supplied by the contractor at their own cost and will not be measured for payment. 3. Cover blocks shall be of same grade of concrete. |
| 34 | Using TMT bars of specified grades all dia bars confirming to IS 1786. All test reports to be provided along with the supply of the materials. |
| 35 | Providing Structural steel work in M.S Plain Plates and chequrred Plates for Embedded Parts, Trench Covers, Connection plates etc.including cutting, hoisting, fixing in position and applying a priming coat of approved zinc chromate steel primer etc. including cost of structural steel Plates, welding all labour charges etc. complete as per drawings and specifications. Using materials manufactured by approved brands of BARC only All test reports to be provided along with the supply of the materials.Notes: 1) Structural steel required for the work shall not be supplied by the Department and the contractor has to procure the same. 2)Welding weights, connections, bolts and nuts, anchor bolts shall not be measured for payment, but the cost of which shall be deemed to have been included in the rate.(3) All holes will be made by drilling only. Gas cutting of holes will not be permitted. (4) Edges of plates shall be grinded to uniform smooth finish. (5) Full length welding shall be carried out as directed by the EIC. |
| 36 | Using materials of approved manufacturers confirming to IS 2062. All test reports to be provided along with the supply of the materials. |
| 37 | Providing Structural steel work using angles, channels, joists and other sections, welded and / or bolted in built up sections for trusses , structural steel floors, frame works, monorails and other structures including supplying, cutting, welding, fabricating, hoisting, fixing in position, applying a priming coat of approved steel primer etc. complete all as per specifications, drawings and as directed by the Engineer in charge.Note: 1) Structural steel required for the work shall not be supplied by the Department and the contractor has to procure the same. 2)Welding weights, connections, bolts and nuts, anchor bolts shall not be measured for payment, but the cost of which shall be deemed to have been included in the rate.(3) All holes will be made by drilling only. Gas cutting of holes will not be permitted. (4) Edges of plates shall be grinded to uniform smooth finish. (5) Full length welding shall be carried out as directed by the EIC. |
| 38 | Up to and including 300 mm Joists, 350 mm channels, and below sections using materials of approved manufacturers confirming to IS 2062. All test reports to be provided along with the supply of the materials. |
| 39 | Providing, supplying, cutting, welding, fabricating, hoisting and fixing in position structural steel members like pergolas, trusses, purlins, posts etc. using MS hollow / circular / square / rectangular tubular sections including applying a coat of Zinc chromate primer of approved make or approved equivalent meeting all the technical specifications as per relevant codes and standards; all as per specifications, drawings and as directed by the Engineer in charge. Note: 1. Yst 310 conforming to latest revision of IS 4923:1997(Reaffirmed in 2009) with yield strength of 310 N/sq. mm(For all rectangular Box sections Grade of steel to be used).2. The contractor shall supply documentary evidence of purchase of steel, Test certificate from approved manufacturers and also third party testing from approved laboratories with out any extra cost. 3. Welding weights, connections, bolts and nuts shall not be measured for payment but the cost of which shall be deemed to have been included in the rates. 4. Welding Electrodes from approved manufacturers or approved equivalent meeting the technical specifications as per relevant codes and standards shall be used (the electrode gives smooth radiographic quality weld with low spatter and smoke). 5. Holes to be drilled only by Drilling machines and gas cutting of holes are not permitted. 6. Rate inclusive of all consumables like GAS, welding electrodes and tools and tackles etc. |
| 40 | Providing and fixing at all levels MS bolts including nuts and washers of approved size, quality and make as per requirements and as per specifications, drawings complete all as directed at site by the Engineer in charge. |
| 41 | Providing and Fixing Anchor Fastner 12 mm dia & 145 mm long including cost of all materials, drilling charges, hirecharges for drilling machines and loabour charges etc. complete. Tentative suggested make of anchor fasterner: M/s Hilti or equivalent complying to the tecnical specification of suitable HST/HSL sa per design provision or as per latest provision of IS 1946. |
| 42 | Providing and fixing in position 50 mm thick Thermocole Board heavy density min. 18.00 kg/m3 at ceiling using rubber based adhesive of approved quality all complete as directed by Engineer-In- Charge. |
| 43 | Providing and fixing anodized aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / Z Sections and other sections of approved make confirming to IS 733 and IS 1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically whereever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P brass / stainless screws all complete as per architectural drawings and and directions of Engineer-in-charge including scaffolding, providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required filling the gaps using silicon sealent etc. (fittings glazing and panelling shall be paid for separately). Notes : 1) The rates for aluminium is inclusive of all fastners required for fabrication and fixing in the walls. 2) All joints shall be of mittered Joints. 3) A long M.S rod threaded at both ends to be provided in all aluminium door shutters in Top & bottom Horizontal members internally connecting Vertical members and fixed with M.S washers & nuts. 4) Only Aluminium members alone shall be measured and paid for relevant item. |
| 44 | Anodised Aluminium sections (Minimum anodizing thickness of 15 micron). |
| 45 | Extra for colour Anodizing |
| 46 | Providing, supplying and fixing hollow metal flush steel doors 40 mm thick of approved make consisting of door frame and shutters and all hardware fittings, frame made out of 14g thick G.I sheets and shutters made of 16g thick sheets, hollow portion filled with puff, including necessary stiffners in shutters and frame, vision panel of specified size with 4 mm glass and clip on pressed steel frame for vision panels, fixing 4 nos heavy duty stainless steel 304 grade ball bearing hinges, mortise / dead lock of approved make, a pair of 200 mm long stainless steel handles, 250 mm long stailless steel tower bolt, etc. frame hollow portion filled with PCC 1:2:4, necessary hold fast embedded in concrete, fixing in concrete with anchor fastners. finished with Polyurethane painting of approved colour complete all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 47 | Providing and fixing glazing in aluminium doors, window, ventilator shutters and partitions etc with PVC / Neoprene gasket etc. complete as per the architectural drawings and directions of the Engineer-in-Charge (Cost of snap beading shall be paid in basic item). |
| 48 | With clear float glass panes of 6.0 mm thickness |
| 49 | With tinted colour float glass panes of 6.0 mm thickness |
| 50 | Providing and fixing 4 Lever Mortice Lock of approved make suitable for aluminium sections. |
| 51 | Providing and fixing double action hydraulic floor spring of approved brand and manufacturer (confirming to relevant Indian Standard) for doors including cost of cutting floors as required, embedding in floors and cover plates with M.S. pivot and single piece of M.S Sheet outer box with slide plate etc. complete as per directions of Engineer-in-Charge with brass cover plate. |
| 52 | Providing and fixing Approved Quality and shape star locks cum Handle of approved make for sliding shutters. |
| 53 | Providing and fixing approved quality stain less steel body roller wheels of approved make for Sliding shutters. |
| 54 | Lead charges for lead Exceeding 1 KM but not exceeding 2 KM, by mechanical transport including loading, unloading,stacking / levelling etc. Note: The rates in respect of Item No. 45.1 & 45.2 are applicable for the net quantity arrived at after making deductions for voids at 20% and 30% for soil and debries respectively from the corresponding stack/truck measurements. |
| 55 | Soil. |
| 56 | Debris Beyond 1 Km but up to and including 2 km. |
| 57 | Providing and fixing 1 hour fire rated metal framed partions of non load bearing type (98 mm over all thickness) using floor / ceiling channels of 50 x 32 x 32 x 0.55 mm size at top & bottom perimeter of the partition and studs of 48 x 50 x 48 x 0.55 mm vertically at maximum of 610 mm centre to centre and bracing members of 45 x 15 x 15 x 0.90 mm at horizondal at all board joints with 10 mm thick calcium silicate board on both sides with self drilling screws to metal frame at 200 mm C/C over fillet of 12 mm metal frames & studs . All cavities in the partition shall be filled with mineral wool of 50 mm thick of densisty 48 Kg / Cu.M. All joints shall be filled & finished with joining compound and 48 mm wide fiber tape to get seamless finish. A coat of cement primer, putty and finished with 2 coats of acrylic emulsion paint of approved make complete all as per the drawings / fabrication drawings as per manufacturer's specification and as directed at site by the Engineer-in-charge. |
| 58 | Carrying out Civil Engineering works like surveying & leveling, checking of formwork fabrication, reinforcement fabrication as per drawings, witnessing sample retrieval & testing for various construction materials, ensuring concrete ingredient ratio at batching plant and pouring of appropriate grade of concrete in plain and reinforced concrete works, ensuring proper mixing of approved ingredients & waterproofing admixtures for mortars and brickwork, plaster, flooring & waterproofing works, and other civil & PH works including supervision of construction safety as per BARC specifications & relevant documentation, compiling, binding and preparation of tender documents & Agreements overall as directed by Engineer-in-Charge. Notes : (1) Each Job shall be carried out by one qualified Technician having minimum SSC with Trade certificate in Masonry/Plumber/Carpenter/ Painter Trade of not less than one year duration from ITI/Government Recognised Vocational Training Institute or experienced Technician retired from Government service. (2) Deployment: The contractor shall deploy one Technician for each job as Single Day work for 6 working days per week for minimum 8 ½ hours per day with 30 minutes of break, in General (Ist / IInd) or on Round the clock shift including Saturdays, Sundays & holidays whenever necessary as per the discretion of the Engineer-in-Charge during the contract period. In case of emergency works like continuous pouring of concrete or shutdown/maintainance work, the Technician will have to stay longer occasionally as per the instruction of the Engineer in-charge. No additional payment will be made on this account. (3) Period of work: The contractor shall carry out number of Jobs per day as directed by Engineer-in -Charge. (4) Mode of measurement : Measurement will be per job basis per day. A single job shall be carried out by deploying one Technician exclusively for the particular job. (5) The Technician should be engaged after scrutiny by EIC of CED, BARC and approved by Competent authority and the deployed Technician will report to BARC Engineer/ EIC. (6) The minimum notice period before change of technician is 1 (One) month; failing which a compensation, for not providing technical support, of Rs. 1249/- per day of shortfall in notice period will be levied on the contractor. |
| 59 | Providing and Fixing Anchor Fastner of approved make including drilling in concrete as per requirement for fixing Eps or other structures all as specified by the manufacturer complete all as per specifications and drawings. |
| 60 | 20 mm diameter 100 mm Long |
| 61 | Providing and applying / injecting general purpose, high flow, Class A, non-shrink grout having high flowability through voids, bottom of base plate, tie rod hole and/or gap of min. 10 mm up to 100 mm, by mixing potable water, in a controlled manner by forced-action mixer, in the range of min. 2.9kg to max. 4.1kg per 20 kg bag of grout depending on the required consistency including cost of materials, labour, equipment, tools & tackles and consumables etc. all as per manufacturer's specification and as directed by Engineer-in-charge. Technical parameters: (i) Compressive strength (as per AS 1478.2) in the range of min. 60 MPa to 75 MPa at 28 days depending upon consistency of the grout mix. (ii) Flexural strength (as per AS 1012.11) min. 13 MPa at 28 days, (iii) Indirect tensile strength (as per AS 1012.10) min. 6 MPa at 28 days, (iv) setting time (as per AS 1012.18) - Initial Setting Time min. 5.5 hours and Final Setting Time max. 7.5 hours (v) Flow characteristics (as per AS 1478.2): 400-600mm (Flow Trough) and 25-30 seconds(Flow cone). Rate will be inclusive of mixing, pouring, curing as per manufacture's specification, including scaffolding, complete all as per specifications and as directed by Engineer-in-charge. |
| 62 | Design, manufacture, supply, installation, testing and commissioning of LT PCC panel as per TSS 1 of electrical specification |
| 63 | SITC of Light point wiring as per TSS 2 of electrical specification |
| 64 | Primary switch box points with 2.5sqmm FRLS wire |
| 65 | Secondary switch box points with 2.5Sqmm FRLS wire |
| 66 | Primary lighting points with 1.5Sqmm FRLS wire |
| 67 | Secondary lighting points with 1.5Sqmm FRLS wire |
| 68 | Fan point wiring 1.5Sqmm FRLS wire |
| 69 | Exhaust fan point With 1.5Sqmm FRLS wire with 2P MCB and metal socket |
| 70 | SITC of Power point wiring as per TSS 3 of electrical specification |
| 71 | Primary power points with 2.5sqmm FRLS wire |
| 72 | Power point for A/C and geyser with 4.0sqmm FRLS wire |
| 73 | Secondary power points with 2.5sqmm FRLS wire 6+6 A |
| 74 | SITC of Distribution Boards as per TSS 4 of electrical specification |
| 75 | TPN LDB, 12 Way, with 63A MCB as incomer + 2P RCCB as PPI. |
| 76 | TPN PDB, 12 Way,with 63A MCB as incomer + 2P RCCB as PPI. |
| 77 | TPN ACDB, 6 Way, with 63A MCB as incomer + 2P RCCB as PPI. |
| 78 | VTPN DB, 12 way, 125A MCCB as incomer |
| 79 | TPN L/PDB, 12 Way, with 63A MCB as incomer + 2P RCCB as PPI. |
| 80 | SITC of Lighting fixtures as per TSS 5 of electrical specification |
| 81 | 36 Watts 2 x 2 ft LED lighting fixtures Recess type. |
| 82 | 20 watts 4 ft LED lighting fixture batten type. |
| 83 | 12W Surface light for entrance |
| 84 | SITC of fans as per TSS 6 of electrical specification |
| 85 | 1200 Sweep Ceiling fan powered by BLDC motor with remote |
| 86 | Exhaust fans, Sweep 450 mm(approx) |
| 87 | SITC of Earthing strip/wire as per TSS 7 of electrical specification |
| 88 | 8 SWG copper wire |
| 89 | 25mm x3 mm copper strip |
| 90 | SITC of MCB with MS enclosure as per TSS 8 of electrical specification |
| 91 | 32A 4P MCB, D-curve |
| 92 | 10A 4P MCB, D-curve |
| 93 | SITC of 4 way FRP Junction Box(approx 100mmx100mmx50mm) with 4 no elemex connector as per TSS 9 of electrical specification |
| 94 | SITC of DLP trunking, double partition size 150*50mm with all accessories as per TSS 10 of electrical specification |
| 95 | SITC of 300mm width perforated cable Tray as per TSS 11 of electrical specification |
| 96 | SITC of conduits and casing as per TSS 12 of electrical specification |
| 97 | SITC of 32mm X 12mm Casing capping |
| 98 | SITC of 25mm PVC rigid conduit |
| 99 | SITC of 50mm PVC Flexible conduits |
| 100 | SITC of cables as per TSS 13 of electrical specification |
| 101 | SITC of of 4 C X 2.5 Sq.mm. Cu conductor cable |
| 102 | SITC of of 4 C X 25 Sq.mm. Al conductor cable |
| 103 | Only Installation of 3.5 C X 120 Sq.mm. Al conductor cable |
| 104 | Only Installation on Surface of 3.5 C X 50/70 Sq.mm. Al conductor cable |
| 105 | SITC of end termination as per TSS 14 of electrical specification |
| 106 | SITC of end termination for 4 C x 2.5 Sq.mm cable |
| 107 | SITC of end termination for 4 C x 25 Sq.mm cable |
| 108 | SITC of end termination for 3.5 C x 120 Sq.mm cable |
| 109 | SITC of end termination for 4 C x 50/70 Sq.mm cable |
| 110 | MS supports as per TSS 15 of electrical specification |
| 111 | Removal of Electrical Items cable/conduit/Lighting fixtures/RI as per TSS 16 of electrical specification |
| 112 | Removal of Electrical Items cable/conduit/Lighting fixtures/RI/fans etc |
| 113 | Removal of Lighting fixtures/switch box/MS box/power point/D.B remova/fans/networking points |
| 114 | Removal of wall fan/Exhaust fan height approx 6 meter |
| 115 | Removal of High Bay light Height approx 9 meter |
| 116 | Removal of Electrical LT PCC panel as per TSS 17 of electrical specification |
| 117 | Supply, installation, testing and commissioning of FA cable 1 pair x 1.5 sq.mm multistranded shielded twisted pair cable to be laid wall/column/false ceiling (on surface) etc as per TSS 18 of electrical specification |
| 118 | Removal and reinstallation of existing Fire detector/mcp/hooter/RI as per TSS 19 of electrical specification |
| 119 | SITC of end Termination of Fire Alarm cable (End jointing - End jointing of following multistranded copper multistranded conductor armoured cables with copper lugs duly crimped to the leads and connected to respective terminals. Supply and installation of all jointing materials such as copper lugs/single compression siemens type brass cable glands, cable tag, nuts bolts etc. are within the scope of this item as per specification.) TSS 20 of electrical specification |
| 120 | SITC of 3ft (1m) CAT 6 Patch cord as per TSS 21 of electrical specification |
| 121 | SITC of triple RJ 45 Network points as per TSS 22 of electrical specification |
| 122 | Split Air Conditioners:Supply, installation, testing and commissioning of Air Conditioning equipments of following nominal capacities as per Technical Specification Sheet No. 1 (TSS-01) of tender technical specification. |
| 123 | High wall mounted Inverter type BEE 5 star rated Split Air Conditioners of 2 TR Nominal capacity |
| 124 | High wall mounted Inverter type BEE 5 star rated Split Air Conditioners of 1.5 TR Nominal capacity |
| 125 | Copper tubing:Supply and installation of refrigeration quality copper tubing of minimum 24 gauge thick along with 19 mm thick sleeve type insulation (Closed Cell Elastomeric Nitrile Rubber Foam Insulation) wrapped with mansoon tape required for installation of split air conditioners of following capacities at site as per Technical Specification Sheet No. 2 (TSS-02) of technical specification. Please note that control cable and power cable required for indoor and outdoor unit also included in this item. NB: Each running meter of copper tubes will consists of one meter each of suction & discharge line along with insulation, control cable and power cable required between indoor and outdoor unit. |
| 126 | Copper tubing for Split type air conditioners of 2TR Nominal capacity |
| 127 | Copper tubing for Split type air conditioners of 1.5TR Nominal capacity |
| 128 | Condensate Drain Piping: Supply and lying of 40 mm PVC condensate drain pipe long with 6 mm sleeve type insulation wrapped with monsoon tape as per Technical Specification Sheet No. 3 (TSS-03) of technical specification. |
| 129 | PVC Trunking: Supply and installation of casing - capping (PVC trunking) of 100 x 65 mm size for enclosing refrigeration tubing, condensate drain piping and electrical cable as per Technical Specification Sheet No. 4 (TSS-04) of technical specification. |
| 130 | MS Structure: Supply, Fabrication and installation of MS structure, as per Technical Specification Sheet No. 5 (TSS-05) of technical specification. |
| 131 | Supply and installation of heavy duty 12\\" dia propeller exhaust fans of 900 rpm complete with gravity back-draft damper, suitable for minimum 1100 CMH free air delivery capacity on single phase power supply as per Technical Specification Sheet No. 6 (TSS-06) of technical specification. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysDec 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender