Housing Urban and Rular Development Government Departments Closing in 10 days TDR #58579571

Tender For Construction Of Bar Association And Facility Centre At Dhenkanal (G+2) Buildings.

Issued by Government Departments · Dhenkanal, Odisha
Tender Value
6.51 Crore
Estimated cost
Bid Submission
02 Dec 2026
10 days left
EMD
6.51 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dhenkanal → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Bar Association And Facility Centre At Dhenkanal (G+2) Buildings.

BOQ

Name of Work:- Construction of Bar Association and Facility centre at Dhenkanal (G+2) Buildings.
Sl. No. Item Description
1CIVIL WORKS:-Providing 375mm dia single under reamed bored compaction RCC pile with M-25 grade concrete including cost of boring to required dia meter and depth to plumb and taking precautionary measure against collapsing of side soil due to presence of water table using bentonite powder etc. concreting and driving the cage made of M.S. / T.S. steel as per approved drawing into the freshly laid concrete vertically by means of power winch to required depth but excluding cost of M.S / T.S. steel and labour charges for cutting ,bending and binding of steel etc. complete confirming to IS -2911 specification including necessary routine tests including cost ,conveyance,royalties and taxes of al+B220l materials with labour with labour ,labour cess and T&P etc. required for the work complete as per the specification and instruction of Engineer-in-Charge.
2For each additional depth 0.50mt beyond initial depth 6mt.Add extra to the rate
3Earth work in excavation in foundation in ordinary soil, with all leads and lifts including dressing and leveling the bed and depositing the excavated earth at place away from work site with all leads and lifts including cost of all labour and T&P and dewatering if required for the work etc. complete and as directed by the Engineer-in-charge.
4Back filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.
5Carriage / disposal of excavated surplus earth from the worksite by mechanical means within a lead of 5Km including loading and unloading etc. complete. in all respect as per direction of Engineer-in-Charge.
6Supplying and filling in foundation trenches and plinth with sand, well watered and rammed in layers not exceeding 23cm in depth with all lead and lift including cost, conveyance, loading, unloading, royalties and , materials, cost of all labour, sundries, T&P required for the work etc. complete in all respect as directed by the Engineer-in-Charge.
7Providing and lying Plain Cement Concrete of proportion (1:3:6) in foundation and floors using 4cm (1 1/2\\") 0 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading,cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge.
8R.C.C. (M 25) using 20mm and 10mm size crusher broken Chips including cost, conveyance, royalty taxesof all materials, labour and T&P require for the work etc. complete with cost of centring & shutterign etc. (GROUND FLOOR) Foundation & bases of column
9Plinth Beam
10Pedestal & Columns
11Roof Beam
12Lintel
13Chajja
14R.C.C. floor and roof slab
15R.C.C. staircase
16R.C.C. Wall
17FIRST FLOOR (Columns)
18Roof Beam
19Lintel
20Chajja
21R.C.C. floor and roof slab
22R.C.C. staircase
23SECOND FLOOR (Columns)
24Roof Beam
25Lintel
26Chajja
27R.C.C. floor and roof slab
28R.C.C. staircase
29HEADROOM (Columns)
30Roof Beam
31Lintel
32Chajja
33R.C.C. floor and roof slabs
34Cutting, straightening coiled or bent up M.S. rods, HYSD steel or Tor Steel welding or jointing if necessary, bending, binding, tying the grills as required for RCC works, and hoisting, lowering and placing in proper position according to approved designs and drawings including cost, conveyance, loading, unloading, M.S. rods, HYSD steel or Tor steel and binding wires of 18 to 20 gauge required for the work and cost of all labour, sundries, T&P and scaffolding complete in all respect as directed by the Engineer-in-Charge (payment will be made according to the actual weight of M.S. rod, HYSD steel or Tor steel consumed in the work and no separate payment will be made towards weight of binding wires which is to be borne by the contractor at his own cost).GROUND FLOOR
35FIRST FLOOR
36SECOND FLOOR
37HEADROOM
38Fly Ash brick masonry using fly ash bricks of size 25 cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:6) with ordinary portland cement (OPC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge (Foundation & Plinth)
39GROUND FLOOR
40FIRST FLOOR
41SECOND FLOOR
42HEADROOM
43Providing 16 mm. thick cement plaster (1:6) finished smooth to inside brick walls after racking out the joints including watering and curing with cost, conveyance, loading, unloading, royalties of all materials, cost of all labour, T&P, sundries and scaffolding required for the work etc. with providing grooves as directed by the Engineer in charge. (Ground Floor)
44FIRST FLOOR
45SECOND FLOOR
46HEADROOM
47Providing 6mm thick cement plaster in cement mortar of (1:4) to RCC surfaces such as ceilings of roof slabs, stairs, landings, chajja, shelves, columns, beams and lofts etc. including roughening/chipping, scraping and cleaning and finishing the plastered surface smooth using wooden floats, bars, etc. only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawing including cost of all materials, conveyance, loading and unloading, royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge. (Ground Floor)
48FIRST FLOOR
49SECOND FLOOR
50HEADROOM
51Providing 12 mm. thick cement plaster (1:6) finished smooth to inside brick walls after racking out the joints including watering and curing with cost, conveyance, loading, unloading, royalties of all materials, cost of all labour, T&P, sundries and scaffolding required for the work etc. with providing grooves as directed by the Engineer in charge.(Ground Floor)
52FIRST FLOOR
53SECOND FLOOR
54HEADROOM
55Providing vitrified tile flooring using premium grade Vitrified tiles having thickness of 8mm to 10mm conforming to IS 13756 of size 600mm x 600mmColour & Printed Series (homogeneous) of approved quality of Somany / Kajaria / Asian / Johnson or equivalent in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the vitrified tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge.(Ground Floor)
56FIRST FLOOR
57SECOND FLOOR
58Supplying , fitting and Fixing Premium grade vitrified tile in dado /skirting of 10MM thick, size 600mm x 600mm with water absorption less than 0.3 % of somany / Kajaria of approved make having base price of the tile Rs. 90 / sqft confirming to I.S.15622 laid on 12mm thick cement mortar (1:3) (1 cement : 3 coarse sand) and filling joints with white cement of approved quality including cost of all materials, labour, T&P etc. required for the work all complete as per direction of Architect. (Ground Floor)
59FIRST FLOOR
60SECOND FLOOR
61Providing Granite stone prepolished 20mm thick of area above 0.40 Sqm in flooring of approved quality, colour and size in floors, treads on steps and landings in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge.(Ground Floor)
62FIRST FLOOR
63SECOND FLOOR
64Providing Granite stone prepolished 10mm thick in dado of approved quality, colour and size in dado, riser of steps and dado of landings in all floors at all height on 12mm thick bed of cement mortar of mix (1:3) with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge.(Ground Floor)
65FIRST FLOOR
66SECOND FLOOR
67Supplying , fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. (Ground Floor)
68FIRST FLOOR
69SECOND FLOOR
70HEAD ROOM
71Supplying, fitting and fixing of M.S grills, Grill window ( as per I.S. specification and as per approved drawings ) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damaged walls/ structures with cement concrete (1:2:4) with black hard crusher broken granite stone chips of 12mm to 20mm size ( 20mm size not to exceeds 25% ) including watering and curing etc. complete in all respect as directed by the Engineer in charge ( W.I. / M.S. windows grills, grill gates, collapsible gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows, staircase and parapet railings square bar along with required nos. of nails and screws and other required materials of approved quality and approved size shall be supplied by the contractor at his own cost.) (Ground Floor)
72FIRST FLOOR
73SECOND FLOOR
74Finishing wall surface of walls with wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials, labour T&P etc. complete the work as per the direction of engineer incharge.(Ground Floor)
75FIRST FLOOR
76SECOND FLOOR
77HEADROOM
78Providing Wall painting with cement primer(water bound )one coat to the internal wall surface including cost of all materials, labour, Tools & Plant, Brushes etc. complete in all respects as per the direction of engineer incharge.(Ground Floor)
79FIRST FLOOR
80SECOND FLOOR
81HEADROOM
82Painting 2(Two) coats with any approved Plastic Emulsion paint to wall surface after cleaning the surface including cost of P.E Paint Cost,Coneyance, of all materials and labour with T&P required for the work etc. comple te in all floors.(Ground Floor)
83FIRST FLOOR
84SECOND FLOOR
85HEADROOM
86Painting to external surface of building with two coats of weather seal coat of approved shade and quality of approved design after cleaning by watering & removing the dirts etc. to the surface to be painted including watering, curing, cost, conveyance of all materials, cost of all labour, brushes, T&P etc. and necessary scaffolding work complete as directed by the Engineer-in-charge.(Ground Floor)
87FIRST FLOOR
88SECOND FLOOR
89HEADROOM
90Providing Wall painting with cement primer(water bound) one coat to the external wall surface including cost of all materials, labour, Tools & Plant, Brushes etc. complete in all respects. (Ground Floor)
91FIRST FLOOR
92SECOND FLOOR
93HEADROOM
94Providing and painting two coats with synthetic enamel paint of approved quality and approved shade confirmming to ISI on steel work to give an even shade in all floors at all height over a coat of primer of approved quality and shade including sand papering and making the surface smooth with cost, coveyance, loading and unloading, of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by Engineer-in-charge. (Ground Floor)
95FIRST FLOOR
96SECOND FLOOR
97Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. (Ground Floor)
98FIRST FLOOR
99SECOND FLOOR
100Providing 2.5 cm thick grading concrete(1:2:2) on roof slab using 6mm size hard granite chips including hoisting, lowering, laying, concrete with watering, curing in all floors with cost, conveyances, royality of all materials, all labour, labour cess, T&P etc. complete as per direction of the Engineer in charge.(Second Floor)
101Providing & applying of pre constructional anti-termite treatment by drilling 12mm dia holes at distance of 30cm @ junction of wall & floor about 300mm apart deep enough to reach the soil below & chemical emulsion (PREMISE, IMIDACHLOPRIED 30.5SC OF BAYER MAKE mixed with 47.5ltr water) pumped these holes to soak the soil @ 1 ltr solution of each hole as per manufactures specification & the holes should be pluged the filling materials including cost of all materials, labour,conveyance, T&P , all taxes and hire charges of machinaries as per direction of Engineer-in-charge.
102Supplying and fitting-fixing of Un-Plasticised Poly Vinyl Chloride (UPVC) (FENESTA/NCL VEKA LTD.) upvc Sliding window with 6mm thick glass duly manufactured using UPVC (Ground Floor)
103FIRST FLOOR
104SECOND FLOOR
105Supplying, fitting and fixing in position chequred tile of approved make and quality, colour and size in all floors at all height on 25mm thick bed of cement mortar of mix (1:1) laid in proper slope and gradient with screened and washed sharp sand for mortar and with Portland Slag Cement (PSC) grouted with neat white cement slurry with required quantities of pigments of approved marks watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work complete in all respect as directed by the Engineer-in-charge
106Providing and laying in position ready mixed M-20 grade concrete having compressive strength at 28 days test not less than 250 kg/ sq.cm for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , including the cost of centering, shuttering finishing and excluding reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, and hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties, of all materials with all labour,Labour cess and T&P required for the work improve workability without impairing strength and durability as per direction of the Engineer - in - charge. (Base)
107Providing & laying Plain Cement concrete (PCC ) of proportion (1:4:8) in foundation and floors using 4cm (1½) size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6) thick to the required level ramming, watering, curing etc. complete including cost, conveyance, royalties and ,es of all materials with all labour, cess and T&P required for the work etc. complete in all respect.
108Providing & laying Plain cement concrete (1:2:4) using 12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concrete in layers, watering, curing etc. complete including cost, conveyance, royalties of all materials with labour, cess and T&P etc. required for the work complete.
109E.I. WORKS:-Internal Electrical Work (Sub-Head I-modular Wiring Items):-Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal 6A modular type ( flame retradant type) switch ISI marked Make- Schneider(Zencelo)/ legrand( Myrius-Next gen)/ Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/ legrand( Myrius-Next gen)/ Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.NB: All the electrical, Fire fighting, HVAC, ELV drawings, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work. GROUP-A
110GROUP-B
111GROUP-C
112Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)(( flame retradant type) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make- Schneider(Zencelo)/ legrand( Myrius)/ Panasonic (vision). (Maximum 02 nos point in one circuit). All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
113Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)(( flame retradant type) with suitable size modular box & cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/ legrand( Myrius)/ Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
114Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make- Schneider(Zencelo)/ legrand( Myrius-Next gen)/ Panasonic (vision) (For equipement power) All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. (Make : Legrand(Myrius-Next gen)/ Schneider(Zencelo)/ PANASONIC(VISION)
115Supplying,fixing of 1x6A+1X16A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & flame retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider(Zencelo)/ legrand( Myrius-NEXT GEN)/ Panasonic (vision) (For equipement power) (Maximum 02 nos point in one circuit). All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
116Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( (flame retradant type) with suitable size modular box & metallic cover plate (both side) (anti bactorial & flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make- Schneider (Zencelo)/ legrand( ( Myrius-))/ Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit). All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
117Supplying,fixing of 2x6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type) both side) (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)((anti bactorial & flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
118Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-guard in recessed HMS FRLS PVC conduit of mentioned size Make- AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
119Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
120Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
121Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI in recessed HMS FRLS PVC conduit of mentioned size Make- AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5)
122Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB) (4X6+2X4)
123Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI / V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .( FLOOR PANEL TO TPN BDB power) (4X10+2X6)
124Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, make:- Schneider/ Siemens/ Legrand/ ABB of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 year against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
125Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
126S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
127Sub-Head II (Light fitting Fixture & Fan):- Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/ Crompton/ Usha/ Orient/ Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
128Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make- Havells/ Crompton/ Usha/ Orient/ Bajaj ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
129Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery 215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(With fan Regulator compatible)
130Supplying an fixing of recess/surface mounted 2'x2'(595mmx595mmx70mm(+/-5%) square shaped LED made up of CRCA powder coated housing with lumen efficacy not less than 140lm/W and lumen output not less than 3600 lumens , CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 -50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/ LT/ Havells / Philips/ Wipro/ Bajaj) . To be used for Library ,Laboratory ,Multipurpose room
131Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/ LT/ Havells/ Philips/ Wipro/ Bajaj).The luminaire should be Replacement Warranty will be 2 years
132SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2000 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/ LT/ Havells/ Philips/ Wipro/ Bajaj). The luminaire should be Replacement Warranty will be 2 years .
133SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/ LT/ Havells/ Philips/ Wipro/ Bajaj)The luminaire should be Replacement Warranty will be 2 years
134Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge . (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved.
135S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/ legrand( Myrius)/ Panasonic (vision)
136BDBS,DB,AC DB,FLOOR PANELS,MCBS :- Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. 4 Way(8+(4x3)+(3x4)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years (FOR LDB, UPSDB)
137Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years
1382+4 way MCB Enclosure DB (GLAZED door) (only each EM. Connection UPS LOAD)Warranty on DB is 3 years
1398 Way(8+(4x3)+(3x8)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-24 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years (FOR PDB)
140Supplying and fixing 20 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make- Legrand-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. Warranty on MCB is 1 years.
141Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 230 volts, MCB . Make- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year..
142Supplying and fixing 16Amps 4P 415 volts, MCB, C series, 10 kA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years
143Supplying and fixing 16Amps 2P 240 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.The RCCB should be Replacement Warranty will be 1 year
144Supplying and fixing 40 amps rating, 415 volts, C series,10KA breaking capacity, FOUR poles MCB of Make- LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year.
145Supplying and fixing 40 Amps rating, dp, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year.
146Supplying and fixing 32Amps 2P 240 volts AFDD(arc fault detection device) Make- ABB S ARC1 M/ Schneider Acti 9/ Siemens Sentron/ Dx3, 10KA, C,IEC-62606 for arc fault in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on MCB is 1 years.
147Supplying and fixing 40Amps rating,C series,10KA breaking capacity, DP 240 volts, MCB Make- Legrand-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement warranty will be 1 years.
148Supplying and fixing 63Amps rating,C series,10KA breaking capacity ,DP 240 volts, MCB Make- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement warranty will be 1 years.
149Supplying and fixing 63Amps 4P 415 volts MCB Make- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on MCB is 1 years.
150Supplying and fixing 63Amps 2P 240 volts RCCB 30 mA Make- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB FB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.The RCCB should be Replacement Warranty will be 1 year
151Supplying and fixing 40Amps 2P 240 volts AFDD(arc fault detection device) Make- ABB S ARC1 M/ Schneider Acti9/ Legrand DX3/ Siemens Sentron,10KA,C,IEC-62606 for arc fault in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.Warranty on MCB is 1 year
152Supplying and fixing of Type (I +II) 3P+N SPD with Lightening impulse discharge current I imp(10/350) µs 7kA/POLE and 25kA total and maximum discharge current Imax(8/20) msec-50kA,with response time<25 nanosec in the incommer of Distribution board, Make-LEGRAND/ Siemens/ Schneider/ OBO/ DEHN in the existing MCB DB with connections as per direction of Engg.-in-Charge.The SPD should have Replacement Warranty will be 1 year.
153(Earthing) INSTALLATION:- Supply & Fixing of Copper plate Earthing (600 x 600 x 3mm thick) including accessories, and providing masnory enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.( For Online UPS only 2nos each)
154Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mm x 600mm x 6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.
155Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
156Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
157CABLING AND END TERMINATION MAIN AREA :- Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/ Polycab/ HAVELLS/ KEI/ Gloster/ RR KABLE of following size cables as per direction of Engg.-in-Charge. 3.5core x 120 sq mm ( DG PANEL 1 RUNS +RAW POWER 2 RUNS)
158Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/ Polycab/ HAVELLS/ RR KABLE/ KEI/ Gloster of following size cables as per direction of Engg.-in-Charge. 4core x 16 sq mm LIFT,UPS
1594 core x 6 sq mm (for small power)
1603.5core x 50 sq mm (From main panel to POWER floor distribution panel )(To FDB LIGHT )
161LAYING OF CABLE:- Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
162Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
163Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in open duct etc as required as per direction of Engg.-in -charge.
164TERMINATION OF CABLES -Supply & Making end Termination with brass double compression gland and Cu/aluminium lugs for PVC insulated and PVC sheathed cable of 1.1 kv grade (without cost of Cable) (Make: Raychem/ M-seal/ 3M) 4 core x16sq mm
1653.5 core x35 sq mm
1663.5 core x50 sq mm
1673.5 core x120 sq mm
168Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching (75 mm depth) and refilling as per direction of Engg.-in-Charge. 50 mm dia
169Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching (75 mm depth) and refilling as per direction of Engg.-in-Charge. 200 mm dia
170MAIN CONTROL PANEL AT GF :- S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list. Type 1 SPD 65ka shall be installed in the incomer. 80X10MM Separate Aluminium Earth bus bar should be installed.In commer-1- 01 number of 250A 4P Icu=100%Ics,36Ka LSIG MCCB with micro processor based release Electrical locking for normal & DG ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula (FROM 100 KVA TRANSFORMER)In commer-2- 01 number of 200A(200-160) 4P Icu=100%Ics,36kA LSIG MCCB with micro processor based release Electrical locking for normal & DG ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula) (DG 160 KVA INCOMMER)In commer-2- 01 no of 200A 4P onload changeover switch (160 KVA DG 01 NO)(Make-C&S/ LK/ Siemens/ Schneider)Busbar-1&2 04 numbers of 300Amps copper busbar with 1.6A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) Out going- 06 numbers of 63-100A 4P MCCB,,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula)2 no. 3P+N 65kA type 1+2 SPD with 63A rating,10KA breaking capacity ,4P MCB (Make-LEGRAND/ Siemens/ Schneider/ ABB/ OBO/ DEHN) (ii) 02 set of digital type multifunction meter with CT for voltage, current, frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data.Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse.Out going- 1 number of 200A 4P Icu=100%Ics, ,25Ka MCCB withTMR based release with adjustable overload ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula)Out going- 6 numbers of 63A rating,10 KA breaking capacity,C series, 4P MCB (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB SB200) Out going- 6 numbers of 32A rating,10 KA breaking capacity,C series, 4P MCB(Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB SB200 ) Out going- 2 numbers of 160A 4P Icu=100%Ics,,25Ka MCCB withTMR based release with adjustable overload ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula)Out going- 03 numbers of 125A 4P MCCB,,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula)
171FDB LIGHT AT 2F,1F:- S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING LIGHT) as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list.Type 2 SPD 40ka shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.In commer- 01 no 100A 4P MCCB 16kA,C series with on/off trip indication Light load for each floor. ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula)Busbar- 04 numbers of 200Amps 25*5mm copper bus bar Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Out going- 06 nos 32A 4P MCB 10kA,C series Light load to LDBs . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB SB200 Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of 0-100Amps Ammeter with CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make & model)(iii) 01 set of 0-500 voltmeter .(DIGITAL)(Sicure/L&T or equievalant make & model)
172FDB RAW POWER AT 1F:- S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING POWER/AC)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list. Type 2 SPD 40kA shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.In commer - 01 no 125A 4P MCCB 25kA, with ROM & S. Link. ( Make-LEGRAND-DPX3/ Siemens-3VA Model/ Schneider- CVS/ ABB Formula) (Icu=100%Ics) with shunt trip.Busbar- 04 numbers of 250Amps, Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Out going- 06 nos 63A 4P MCB 10kA,C series for power BDB. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ ABB SB200 Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of MFM with CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make & model)
173UPS MAIN PANEL:- S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 40X6MM Separate Copper Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication. Provision of 40kA 3P+N type 2 SPD alongwith 63A, 4P, MCB, C series, 10kA is to be given in the incomer.One (12) Incomer comprising of - 100 Amp, 4P onload changeover Switch (Make- Legrand/ Siemens/ Schneider/ ABB Formula) with shunt trip.with axulary for BMS one(1)-Multifunction digital meter suitable for three phase four wire system, unbalanced loading CL 1.0, flush mounting with RS 485 communication port for reading Voltage, Current, pf. KW, KWH, KVA, KVAr, KVAh, KVArHr (BMS Compartibilty)Busbar - 200 Amp, 50KA Cu TP2N busbar suitable for operation at 415 Volt, 50 Hz, 3 Phase supply Four(4) - Outgoing Feeders for (Three nos spare ) each Comprising ofOne (1) - 32 Amp FP, 10 KA MCB (C-Curve) Make- Legrand-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ ABB SB 200)Three(3) - Outgoing Feeders for (Three spare ) each Comprising ofOne (1) - 32 Amp DP, 10 KA MCB (C-Curve) Make- Legrand-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ ABB SB 200
174SUB UPS PANEL:- S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING EMERGENCY LIGHT)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list. 20X10MM Separate Aluminium Earth bus bar should be installed.In commer- 01 numbers of 32 Amps 4P MCB. Make- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 (Icu=100% Isc) with shunt trip & axulary for BMS & mechnical inter locking for one incommer source to other.Busbar- 04 numbers of 100Amps Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Out going- 04 nos 16A rating,10KA breaking capacity,C series, 4P MCB Make- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 Out going- 04 nos 16A rating,10KA breaking capacity,C series, 4P MCB Make- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9Out going- 04 nos 16A rating,10KA breaking capacity,C series, 4P MCB Make- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9Out going- 03 nos 16A rating,10KA breaking capacity,C series, 4P MCB OT/ ICU POWER/ OT MACHINE OR Bed head panel. Make- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of 0-100Amps Ammeter Digital type & CTS.(DIGITAL)(iii) 01 set of 0-500 voltmeter Digital type.(DIGITAL)NB- This panel should have proper earth by suitable rated copper flat.
175SITC of LT indoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder coated paint is designed as G.A drawing. (for Lift) as per direction of Engg.-in-Charge. Warranty period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. Type 2 SPD(3P+N) 40ka with 63A rating, 10KA breaking capacity, 4P MCB shall be installed in the incomer. 20X10mm Separate Aluminium Earth bus bar should be installed. 63amp panel board having 63A Amp 16KA 4P MCCB TMR based release with adjustable overload, Icu=100%Ics as incommer, 100 amp electrolyte cu bus ba-1 Set, 63A Amp TPN RCCB 300mA- 1 No, 25A Amp DP RCCB 30mA- 2 No, 6-32A DP MCB 10ka, c series -2 No as Outgoing with ampere meter, voltmeter, toggler switch, three nos led indicator, Drum insulator, transparent isolation glass, danger Board and Rubber Mat as per the direction of site engineer in charge. (Make of mccb :- Legrand-DPX3/ Siemens-3VA Model/ Schneider- CVS/ ABB formula), Make of MCB-Legrand-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB SB200 (Lift Panel)
176UPS SYSTEM (For EMERGENCY):- Supply ,installation ,testing & commissioning of 20KVA Parallel UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sicuency corrector of 3ph in put to 3 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 65AH, 32 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make: Numeric/ APC/ Vertiv) LOAD OF OT, ICU) as per direction of Engg.-in-Charge. Warrentee period of all accessories & component & system must be 2 years & compelete test certificate must be submitted along with ups including component list & SLD.
177CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER:-Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/ OBO/ Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
178Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W) of MAKE- Profab/ OBO/ Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
179Supplying,fixing of FLOOR RACE WAY WITH JUNCTION box GALVANIZED (GC) type AS PER EN-ISO-1461, with internal dimensions of size 38mm(H) x 225mm(W), of Profab/ OBO/ Neidax. (With all accessories, bend, cover, supporter) WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as required as per direction of Engg.-in-Charge.(3 COMPARTMENT TOTAL 54 MM HEIGHT.
180Supplying,fixing of 8 module under- FLOOR outlet box IP20, size not less than 308mmx308mm as required as per direction of Engg.-in-Charge.MAKE- Profab/OBO/Neidax/Legrand
181Subhead- 2 (IP-CCTV System):- SITC of 5MP IP Bullet/Dome Camera with inbuilt microphone, equipped with 1/2.7\\" Progressive Scan CMOS image sensor and 3.6/2.8(for dome) mm fixed lens, supporting a resolution of 2592 × 1944 or higher. The camera shall provide IR illumination up to 30 meters and an approximate field of view of 79° (H)/97(for dome), 56°/70(for dome) (V), and 106°/128( for dome) (Diagonal). Minimum illumination shall be 0.003 lux @ F1.6 (AGC ON) with support for WDR (120 dB). The camera shall support video compression formats such as H.265+, H.265, H.264+, H.264 and MJPEG, with multiple streaming capability including main stream up to 5MP @ 30 fps, sub-stream up to 1080p @ 30 fps, and additional third stream. The camera shall support intelligent analytics such as human and vehicle detection, perimeter intrusion detection, line crossing detection, object detection, heat map, crowd density detection, queue length detection, and rare sound detection. The device shall support motion detection with multiple configurable zones and network protocols including TCP/IP, HTTP, DHCP, RTP/RTSP, SMTP, NTP, UPnP, SNMP, HTTPS and SFTP, and shall be ONVIF compliant (Profile S/G/T). The camera shall include micro SD card slot up to 256 GB/512 GB( for dome), privacy masking, ICR auto day/night switching, and support 12V DC or PoE power supply. The housing shall be metal body with IP67 weatherproof protection, suitable for outdoor installation. The product shall comply with NDAA requirements and shall be certified with STQC, BIS, CE, FCC and RoHS. Make-Honeywell Value series/Pelco/Axis/Bosch
182SITC of 64CH project series Network Video Recorder, Should support Resolution:- greater than equal to 12 MP IP Camera, Network Bandwidth incoming 640 Mbps and outgoing 640 Mbps for access, support for H.265+/H.265/H.264 encoding format streaming access and decoding output, Recording play back quality: 16 ch play back simultaneously, Recording resolution up to 12MP, Recording mode: support manual, Auto, Motion detection, Alarm, trigger record mode, Operation way: Mouse, local Login: Username and password, Recording storage: Local HDD, network, Video output: HDMI/VGA/TV, Support min. 8 SATA HDDs , Each port supports min. 18TB HDD(Enterprise class),support-RAID0, RAID1, RAID5, RAID6, RAID10,Support dual Gigabit Ethernet ports,Supports 4 HDMI outputs,Alarm Input/out:16 in /4 out ,Audio:1 in / 1 out ,Supports intelligent analytics such as Licence plate detection,Face Recognition,Human&Vehicle Detection,Perimeter Intrusion Detection,Line Crossing Detection, Cross Counting,Stationary Object Detection,Heat Map,Crowd Density Detection,Queue Length Detection, Rare Sound Detection, product must comply with NDAA complaince, Certification: BIS,CE,FCC,ROHS. Make-Honeywell value series /Pelco/Axis/Bosch
183Supply & Installation of surveliance 10 TB HDD. Make: WD/ Segate/ Toshiba
184SITC of 55\\" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony
185AUTOMATIC FIRE DETECTION AND ALARM SYSTEM:-Supply, installing, testing and commissioning of of 4 Loop Network Panel Micro processor based 2 wire fault tolerant loop,with inbuilt network port (each loop accessing 99 or more detectors and 99 or more modules ) fire alarm/detection control panel. The Panel shall have 10000 or more event log history . Panel shall be capable of having 1600 or more configurable zones .The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFFrespective control module when ever any alarm is triggered. The panel shall have 7 Inch Touch Screen unit to indicate Fire/Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects.The Panel Shallbe Sheet Steel Painted, selaed to IP30. The Panel Shall have provision for 40 or more Zones with Individual LED Indicators expdable upto 200 Zones or higher. The panel shall have a built in power supply and battery charger along with maintenance free 7 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 48 hours with battery charger complete as required.and as per specifications. conforming to BS5839 Standards and Duly Approved by EN54 The panel shall support detection logics like coincidence & verification detections for the false alarm management. The Panel shall adjust the sensitivity between day and night to maintain the better detection/reponse time. The Panel shall be capabale of programming through PC ; Touch Screen of USB .This panel having facility of MODBUS protocol over TCP/IP for BMS integration.The panel should have provision for inbuilt RJ45 connection terminal for connecting to the LAN with inbuilt BACNET Protocol. Make- Make-Honeywell(MAX) /Siemens/Bosch/Edward/NOTIFIER/GST/Schneider
186Supplying, installing, testing and commissioning of OEM make ( 4 loop )Cloud based service through universal gateway, which shall be enabled through internet. Remote health monitoring solution shall utilize cloud-based software-as-a-service web application & supplementary network gateway hardware. System shall provide secure web access to cloud-based web application using any of the web browsers like Google Chrome (preferable), Internet Explorer etc. from any computer/ tablet/ smartphone connected over internet via defined credentials username and password. It shall also have the facility to monitor the cloud service over the mobile apps. The cloud-based web application shall capture all fire alarm system data points as received from the system via supplementary gateway hardware of the same make as Fire Alarm Panel. The software shall display real time view of fire system effectiveness, multi-location unified view, custom dashboard, device level information, scheduled reporting, e-mail of critical alarms. The cloud service shall be capable of monitoring 250000 datapoints scattered across multiple install bases spread across multiple geographical locations. The Gateway Card shall be UL Listed.It should have 5 nos. or more user license. Internet/Wi-Fi Connectivity Required.The cost is inclusive of 2 years subscription charges.Software and panel shall be of same make.
187Supplying, installing, testing and commissioning of addressable Manual call point with built in Monitor Module with all accessories complete. The device shall be UL/EN/FM approved..Make-Honeywell(MAX) /Siemens/Bosch/Edward/NOTIFIER/GST/Schneider
188Supplying, installing, testing and commissioning of addressable Hooter at 85 dBA @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication with all accessories etc., complete. Make-Honeywell(MAX) /Siemens/Bosch/Edward/NOTIFIER/GST/Schneider
189Supplying, installing, testing and commissioning of adressable multi sense smoke detector with inbuilt isolator module/isolator base,base, junction box and other accessories.Make-Honeywell(MAX) /Siemens/Bosch/Edward/NOTIFIER/GST/Schneider
190Supplying, installing, testing and commissioning of rate of rise heat detector with inbuilt isolator module/isolator base ,base, junction box and other accessories.Make-Honeywell(MAX) /Siemens/Bosch/Edward/NOTIFIER/GST/Schneider Please Enable Macros to View BoQ information
191Supplying, installing, testing and commissioning of rate of rise heat detector with inbuilt isolator module/isolator base ,base, junction box and other accessories.Make-Honeywell(MAX) /Siemens/Bosch/Edward/NOTIFIER/GST/Schneider Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58579571
AUTHORITY Government Departments
TENDER VALUE 6.51 Crore
LAST DATE 02-12-2026
Authority
Authority Name Road And Building Department
Work Description Tender for Construction Of Bar Association And Facility Centre At Dhenkanal (G+2) Buildings.
Basic Detail
Tender No CCE Dkl (R and B) -18 / 2026-27
Bidding Type Tender
Location
City Dhenkanal
State Odisha
Key Dates
Publish Date 18 Nov 2026
Submission Date 02 Dec 2026
Open Date 03 Dec 2026
Finance
Tender Value 6.51 Crore
Tender Fee 10000
EMD 6.51 Lakhs
Exemption Available
Document List
248fd693-03c3-4fab-8024-7ad37973492f.html
BOQ_621950.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Dec 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

248fd693-03c3-4fab-8024-7ad37973492f.html

xls

BOQ_621950.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender